Input Specifications Input Channels Input Range VDC Signal Resolution -bit Resolution Value of SB (least significant bit) Data Range Input Type Maximum Continuous Overload ±VDC Input Impedance kω Hardware Filter Characteristics Sample Duration Time All Channel Update Rate Open Circuit Detection Time Conversion Method Accuracy vs. Temperature Maximum Inaccuracy inearity Error Input Stability and Repeatability Full Scale Calibration Error (including offset) Offset Calibration Error Max Crosstalk at DC, Hz and Hz External Power Supply Required VDC =. mv per count (SB = count) 89 counts Single-ended ( common) ow Pass, -db @ Hz. ms per channel (does not include ladder scan time) ms Zero reading within ms Successive approximation ±PPM / ºC maximum.% of range (including temperature drift) ±.% of range Monotonic with no missing codes ±.% of range ±.9% of range ±.9% of range ±.9% of range VDC (-% / %), ma P-AD- V V V V V V -VDC INPUT ANAOG P-AD- Analog Input The P-AD- ow Resolution Voltage Analog Input Module provides four channels for converting VDC analog signals to digital values of 89 (-bit) for use with the Productivity system. Input Specifications......................... General Specifications...................... Removable Terminal Block Specifications........ Wiring Diagram and Schematic................ Module Installation Procedure................. QR Code................................. Wiring Options............................. Module Configuration....................... inear Scaling............................. Non-inear Scaling......................... Warning.................................. 8 Terminal Block sold separately, (see wiring options on page ). Warranty: Thirty-day money-back guarantee. Two-year limited replacement (See www.productivity.com for details). Sales 8-- www.productivity.com
Operating Temperature Storage Temperature Humidity Environmental Air Vibration Shock Field to ogic Side Isolation Insulation Resistance Heat Dissipation Enclosure Type Module ocation Field Wiring EU Directive Connector Type (sold separately) Weight Agency Approvals General Specifications º to ºC (º to ºF) -º to ºC (-º to 8ºF) to 9% (non-condensing) No corrosive gases permitted IEC8-- (Test Fc) IEC8-- (Test Ea) 8VAC applied for second > MΩ @ VDC mw Open Equipment Any I/O position in a Productivity System Use ZIPink Wiring System or removable terminal block (sold separately). See Wiring Options on page. See the EU Directive topic in the Productivity Suite Help File. Information can also be obtained at: www.productivity.com -position Removable Terminal Block g (. oz) *See CE Declaration of Conformance for details. U -- file E99, Canada & USA CE (EN- EMC and EN-- Safety)* Terminal Block Specifications Part Number P-RTB P-RTB- Positions Screw Terminals Spring Clamp Terminals Wire Range AWG (.. mm²) Solid / Stranded Conductor / in (. mm) Insulation Max. / in ( mm) Strip ength 8 AWG (.8. mm²) Solid / Stranded Conductor / in (. mm) Insulation Max. 9/ in ( 8 mm) Strip ength Conductors USE COPPER CONDUCTORS, ºC or equivalent. Screw Driver. in (. mm) Maximum* Screw Size M N/A Screw Torque. lb in (.8 N m) N/A *Recommended Screw Driver TW-SD-MS- www.productivity.com Tech Support -8-
P-AD- Schematic P-AD- Wiring Diagram VDC User Supplied Power - V V V V V V INTERNA MODUE CIRCUITRY ISOATED ANAOG CIRCUIT POWER CH ADC CH ADC CH ADC CH ADC -Wire Voltage Transmitter AC or DC -Wire Transmitter -Wire Voltage Transmitter Voltage Input Circuits Transmitter Power Supply -Wire Transmitter - V V VDC User Supplied Power ISOATED ANAOG CIRCUIT MON Notes for maximum accuracy:. Jumper unused inputs to common. V V Sales 8-- www.productivity.com
Module Installation QR Code WARNING: Do not add or remove modules with field power applied. Step One: With latch gram ring Dia TD Wi P-8 e Single r Sourc Powe P-8TD P-8TD in locked position, align connectors on the side of each module and stack by pressing together. Click indicates lock is engaged. - - 8 - VDC e r Sourc Powe Dual V Use any QR Code reader application to display the module s product insert. WIRE STRIP ENGTH MAX MIN OCK Step Three: To unstack modules, pull locking latch up into the unlocked position and then pull modules apart. www.productivity.com - Tech Support -8- V 8 9 8 VDC Check all latches are secure after modules are connected.. - - VDC P-8TD UNOCK V 8 9 Step Two: Attach field wiring using the removable terminal block or ZIPink wiring system. V
Wiring Options ZIPink Connection System Cable ZIPink Module = Complete System ZIPink pre-wired terminal block s. m (. ft). m (. ft). m (. ft) Z-P-CB Z-P-CB- Z-P-CB- Module Configuration Using the Hardware Configuration tool in the Productivity Suite programming software, drag and drop the P-AD- module into the configuration. If desired, assign a User Tagname to each input point (channel) selected and to each Status Bit Item. Z-RTB- Z-RTB ZIPink Modules Feed through Z-RTB Z-RTB- Terminal Block with pigtail. m (. ft). m (. ft) Z-P-CB-P Z-P-CB-P Screw Terminal Block only P-RTB (Quantity ) Spring Clamp Terminal Block only P-RTB- (Quantity ) Sales 8-- www.productivity.com
inear Scaling Non-inear Scaling The Scale (inear) function can be used to: Convert an application specific range to range which is native to the analog output module. Make other linear conversions in ranges appropriate to the application. The Scale (Non-inear) function can be used for Non-inear applications. evel Transmitter Tank evel Display Gauge Motor Speed Motor Driver Select the Input and Output tags appropriate for the application. Convert raw input signals to engineering units for use in the program, or convert engineering units to output signals for control purposes max..... Enter actual output values for each input value break point. min min max www.productivity.com Tech Support -8-
Sales 8-- www.productivity.com
WARNING: To minimize the risk of potential safety problems, you should follow all appli local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and it is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation are in compliance with the latest revision of these codes. Equipment damage or serious injury to personnel can result from the failure to follow all appli codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call Technical Support at -8-. This publication is based on information that was available at the time it was printed. At AutomationDirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Document Name Edition/Revision Date P-AD--DS st Edition 9// Copyright, AutomationDirect.com Incorporated/All Rights Reserved Worldwide 8 www.productivity.com Tech Support -8-