Univox FSM 2.0. Multitone Field Strength Measurement Microprocessor controlled. User Guide. FSM 2.0, Part No

Similar documents
Univox Loop Listener. Loop receiver and testing device. User Guide. Univox Loop Listener Part No /230453

Univox P-Loop 2.0. Portable loop case. User Guide. Univox P-Loop 2.0 Part No

Univox CLS-5. Environmental friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide

PLS-700 Univox Loop driver Installation Guide

UniVox CTC Loop amplifier for cross-the-counter systems

Univox P-Loop 2.0. Portable loop case. User Guide. Univox P-Loop 2.0 Part No

Univox CLS-1. Compact and powerful induction loop amplifier for TV/music/microphone. User Guide. Art.nr

Univox CLS-5. Environment-friendly loop amplifier for TV rooms and installations in elevators/buses. Installation Guide

CTC-systems. Cross-The-Counter Loop System. Installation Guide

Univox SLS-1/3/5 Class D Tech Series State of the art phased array loop drivers

Univox PLS-X1, X3, X5

12V MINI AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

PLA-240. Small Room Loop Amplifier System. USER Manual MAN 211A

19'' Rack Mount 300 Watt Power Amplifier/ Mixer w/70v Output & Mic Talkover USER MANUAL

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

Visit us at

Mixer Amplifier series

Contents Components... 1 Loop Installation Options... 2 Loop Pad Installation... 3 Loop Wire Installation... 4 HLD3 Driver Connection...

SP980. Cordless Stereo 863MHZ. Speaker System. User s Manual INTRODUCTION FEATURES. Please read before using the equipment

Sampling and Reconstruction

i3speakers LX503 MK2 User Manual

Comfort Digisystem User Manual. SecureStream Technology. Comfort Digisystem. Receiver DT10. English

200Amp AC Clamp Meter + NCV Model MA250

FISCHER AMPS MANUAL. In Ear Amp 2

User Guide. Digital AC/DC Clamp Meter Model 38394

Minirators MR-PRO / MR2

User s Guide. Digital AC/DC Clamp Meter Model 38394

Installation Guide & User Manual Sound Plus Infrared System, Model WIR 950

Safety. Legal. stageclix is a trade mark of QDES works BV. QDES Works BV shall in no case be liable for damages arising from use of this product.

How To... Commission an Installed Sound Environment

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

PST 100 YPSILON PRE AMPLIFIER MKII. OWNERS MANUAL V2 01/01/2010 All rights reserved

MODEL 3 MONO AMPLIFIER OWNER S MANUAL

USER MANUAL. GOLDMUND TELOS 590 NextGen Integrated Amplifier

400Amp True RMS AC Clamp Meter + NCV

PDA103 AUDIO-FREQUENCY INDUCTION LOOP AMPLIFIER

Sound Level Meter C.A 832

Manual and User Guide

ROBERTS RD-25. Sound for Generations. MW/FM RDS/DAB Digital Portable Radio. Please read this manual before use

User s Guide. 400A AC/DC Clamp Meter. Model MA220

DX-395. FM/AM/SW1/SW2 PLL Synthesized Receiver OWNER S MANUAL. Cat. No Please read before using this equipment.

AMM-1022 Digital Multimeter USER`S MANUAL

Pocket Size Digital Multimeter with USB Model: A & A

User s Manual. Ground Resistance Clamp On Tester MODEL

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

Comfort Contego User Manual

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Universal audio/midi interface USER MANUAL

BS 17 SINGLE CHANNEL BELTPACK. User Manual. January 2017 V1.0

Studio MODEL:PA600X/PA800X/PA1000X/ PA1800X PA AMPLIFIER PRO. High Performance Professional Audio.

QUICKSTART OWNER S MANUAL (ENGLISH) 1 8 MANUAL DE INICIO RÁPIDO DEL USUARIO (ESPAÑOL) 9 16 GUIDE D UTILISATION SIMPLIFIÉ (FRANÇAIS) 17 24

Trantec S5 Wireless Microphone Series

NEXUS. VIP series II OWNERS MANUAL. For EUROPEAN 220V -230V OPERATION HEXFET & SMPS TECHNOLOGY AUDIO POWER AMPLIFIER

a Loop System LA240 User manual ACCESS TO SOUND

PPA 377. Personal PA FM Listening System FM SPECIFICATION DATA. System Includes:

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

MA6004 MA6002 MARINE AUDIO POWER AMPLIFIER OWNER S MANUAL. The Official Brand of Live Music.

E-400 power amplifier. user manual

User Guide. Version 1.0 POWER

User Manual VOLUME PTT 1 MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10 LEVEL LEVEL TREBLE 6 MIC

Power Amplifier D2 D3 D4 D5 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Dual Channel Power Amplifier D2 D3 D4 D5. User Manual & Installation Guide

ReSound Micro and Multi Mic

RU210. Dual Multi-UHF Wireless System. Item ref: UK, UK User Manual. Version 1.0

Instructions for use. English. Comfort Digisystem. Programmer DT20

Manuel Campus S FM Transmitter (TX2S)

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

ProfiScale MULTI Multimeter

SDM3045X Digital Multimeter. DataSheet

xepton 2.4 GHz Tour Guide System User manual xepton RP-1 stationary repeater

ListenRF Stationary RF Brochure

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

ZM 84 Audio Mixer. User Manual. Order code: CRAM41. Audio Mixer ZM 84 AUX 3 AUX 1 AUX 2 AUX 4 MASTER 1 MASTER 2 OFF BASS BASS TREBLE TREBLE BASS BASS

Not for Reproduction

RD-21 ROBERTS. FM RDS/DAB digital radio. Sound for Generations. Please read this manual before use

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Dawson DDM190. Digital Multimeter User s Manual

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Boulder W Class A Stereo Power Amplifier

T L Audio CRIMSON SERIES. User Manual EQ-3012 PARAMETRIC EQUALISER. Tony Larking Professional Sales Limited, Letchworth, England.

WS-29 DUAL CHANNEL WIRELESS BELTPACK

First read the summary. Otherwise, you might find it confusing. There are 2 types of voice to skull:

Pair of PMR446 Two-Way Personal Radios Model: TP391

Digital automotive analyser 13 function with ic

VLR-502 Wireless System. Owner s Guide

CE reference guide english.indd :24:19

E-800 power amplifier. user manual

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

You have acquired the best multi-usage Preamplifier ever made for professional and domestic uses. Please take some

SmartRig+ UC. Two-channel Mic & Guitar Interface. For USB Type-C Devices

What you Need: Exel Acoustic Set with XL2 Analyzer M4260 Measurement Microphone Minirator MR-PRO

CONTENTS ADJUSTMENTS 5 THE ST-100 UNIVERSAL SUPERTWEETER 2 ENVIRONMENTAL CONSIDERATIONS 3 CARE OF THE SUPERTWEETER 6 INITIAL POSITIONING 4

PHYSICS 107 LAB #9: AMPLIFIERS

mix 502, mix 802, mix 1202FX mixer user manual

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

MA6480A. Energy-Efficient, Multi-Function 240-Watt Mixing Amplifier with Dual 70/100 V and 4 Ohms Outputs. Features

E-800 power amplifier. user manual

DBB. On Off. Vol. Lock TUNING DBB FM STEREO/AM PLL SYNTHESIZED RECEIVER DT 110 BAND MO./ST.

The difference between hearing and hearing

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Transcription:

Univox FSM 2.0 Multitone Field Strength Measurement Microprocessor controlled User Guide FSM 2.0, Part No 401040 1

Content Introduction...3 System overview...4 Audio files (test signals)... 4 Basic program description...6 Measurements/programs... 6 To start/activate Univox FSM 2.0...6 Using the instrument... 6 Certificate of Conformity - Step by step...7 1. Background noise measurement (Noise)... 7 2. Field strength deviation/overspill (Coverage)... 8 3. Basic frequency test (FQ)... 9 5. Adjustment of field strength level (Field)... 11 6. Final confirmation and commissioning... 12 7. Voltage clipping in program peaks... 12 Connection to external measurement equipment... 13 General information... 13 Security/Warranty... 13 Maintenance and care... 13 Trouble shooting guide... 13 Service... 14 Technical data... 14 Recycling directives/environment/correct disposal... 14 Notes... 15 2

1. 3. 2. 4. 5. 6. Introduction We thank you for having chosen a Univox product and hope that you will be satisfied. Please read this User Guide carefully before use of this product. In the package you will find the following product parts: Univox FSM 2.0 Field Strength Meter XLR/RCA adapter RCA/3.5mm cable for connection of the signal source to the loop amplifier Earphone adapter, 3.5mm stereo jack/3.5mm mono plug USB memory card containing full user guide, product information and audio files (test signals) Certificate of Calibration Bag 1. LCD display 2. Blue LED, Ready A. Flashes after each completed measurement B. Continuous light in Hold mode 9. 8. 7. Buttons 3. Start Starts/activates the FSM or proceeds to the next measurement step 4. Light Illuminates LCD when pressed. Increases battery drain, use with caution. 5. Stop Turns the instrument off (saves battery) 6. Hold Toggle switch (On/Off) freezes display 7. Output for headphones or external measurement equipment 8. Output level adjustment 9. 9V-battery compartment (rear side) 3

System overview Univox FSM 2.0 is an advanced Field Strength Meter with several features not seen elsewhere. It is based on the experience from Univox FSM which was the first true rms Field Strength Meter in the world. As the very first of its kind, Univox FSM 2.0 makes fast and accurate frequency measurements possible by using multitone measurements (several sine waves presented simultaneously). Multitone measurements have up to now only been possible in laboratories or similar environments. Overspill measurement below the background noise level is for the first time possible with the built-in sharp programmable notch filter in Univox FSM 2.0. The LCD display and microprocessor (µp) make Univox FSM 2.0 easy and straight forward to use. The measurement process is controlled by the µp and displays a step-by-step procedure, according to the international standard IEC 60118-4. Univox FSM 2.0 has many built-in features that are controlled by the µp: Calibrated A-weighted filter, tracking switching capacitor filters, automatic gain range setting, auto off/battery save function etc. With all these features it is possible to perform many different kinds of measurements. The µp can easily be updated in case of future IEC standard enhancements. Note: standard specification could change without notice. Univox FSM 2.0 can also be connected to any external measurement equipment. Read more in the section Connection to external measurement equipment. Audio files (test signals) Multitone and sine wave audio files Some of the measurements are based on precise frequencies and other are based on multitone signals. Five audio files are stored on the USB card: 1kHz.wav, 1kHz_pulse.wav, 1k6Hz_pulse.wav, 3_freq.wav and 16_freq.wav. Use a verified quality computer, MP3 or CD player as signal source. It is recommended to keep the wav format to maintain quality. Do not change the format to a compressed one. Do not use any other standard signals as frequency calibration is very precise and vital for correct results. The measurements are based on exact sine wave frequencies and complex multitone audio files (5 min duration). The signals are mathematically generated and are down sampled to 44kHz/16bit. 4

1kHz.wav 1kHz sine wave, peak level = -3dB (rms -3dB) re FS (Full Signal) 1kHz_pulse.wav 1kHz sine wave pulses (1.5 sec on/3 sec off), peak level = -3dB (rms -3dB) re FS 1k6Hz_pulse.wav 1k6Hz sine wave pulses (3 sec on/3 sec off), peak level = -3dB (rms -3dB) re FS 3_freq.wav Simultaneous sine waves: 100Hz, 1kHz, 5kHz, max peak level = -3.3dB (rms -11.1dB) re FS 16_freq.wav 16 simultaneous sine waves: 100Hz-10kHz, max peak level = -2dB (rms -10.5dB) re FS. Each sine wave level is -20dB re FS. The audio file 3_freq.wav consists of three simultaneous sine waves and is suitable for quick basic check of the upper 5kHz and lower 100Hz frequencies in relation to the 1kHz value. The audio file 16_freq.wav is a more complex and wide multitone signal for comprehensive frequency measurements. The simultaneously presented 16 sine waves with the µp tracking filter gives a more correct and steady measurement compared to pink noise. The wide band signal is compatible with frequency dependent AGC circuitries and alike. Speech audio files Real speech or a synthesized speech signal is recommended for commissioning of the loop system for 400mA/m with ±3dB according to IEC. The following speech audio files are stored on the enclosed USB card as wav files. Use a verified quality computer or MP3 player as signal source. Do not convert the files to any compressed format. 1. ITU-speech, itu.wav is an artificial speech audio file, based on many different languages. It is a mathematically well-defined signal with separate male and female voices. As level is the primary test, the male and female signals are mixed together 2. HA-speech, haspeech.wav is a wav file used by the Hearing Instrument manufacturers for testing equipment with real world signals. The signal consists of short pieces of real speech in six major languages, mixed together. 5

Basic program description There are 5 different programs, numbered 1-5. Each press on the Start button will either start the Univox FSM 2.0 or proceed to the next program. Each measurement repeats continuously. The blue LED will flash once for each completed measurement. The completion time depends on the complexity of the program. Measurements/programs 1. Noise measurement, db and db(a), approximately 1 measurement/sec 2. Field distribution and overspill measurements, db, approximately 3 measurements/sec 3. Frequency, db at 100 1000 5000Hz re 1kHz (IEC) 1.1 sec/measurement 4. Frequency spectrum (16 frequencies) re 1kHz, each measurement 5-8 sec 5. Field Strength level, 3 measurements/sec Measurement 4, frequency spectrum, is not compulsory according to the IEC standard. To save battery life, the Auto on/off function will shut down the Univox FSM 2.0 after approximately 5 min without use. To start/activate Univox FSM 2.0 Press Start. Univox FSM 2.0 activates and program 1 starts. Using the instrument 1. Hold the instrument in vertical position for measuring the vertical field strength. 2. Measure at appropriate listening positions and chosen measurement height (normally 1.2m for sitting and 1.7m for standing listeners). 3. Hold Univox FSM 2.0 in a fixed position during measurements (between each flash of the blue LED). 4. The displayed resolution is 1dB. It must be taken into consideration when interpreting the values. 6

Certificate of Conformity - Step by step Activate FSM 2.0, see Using the instrument above and the Measurement protocol Certificate of Conformity. 1. Background noise measurement (Noise) Description The auto-range feature sets the instrument's gain automatically, depending on the noise level, individually for the A-weighted and flat response for the best dynamic range for noise measurements. FSM-2.0 can measure background noise levels down to -52dBA. Procedure 1. Disconnect the Loop Amplifier from mains power. 2. Press start to activate FSM 2.0 and program 1. Noise 3. Document the background noise levels, with A-weighted filter (dba) and flat (db) in different positions throughout the listening area. Note: If the level for dba and db is equal, the background noise is more likely to be audible in the hearing aid. IEC 60118-4 1. For long time listening it is recommended that the background noise level is below -47dB(A). 2. If the background noise level is higher than -32dB(A), the owner of the premises should be informed and given some suggestions how to accomplish a lower background noise level. 3. For short time announcements, background noise levels of up to -22dBA, can be accepted, as the loop system still will be of use for to hearing aid user. 7

2. Field strength deviation/overspill (Coverage) Description The precise 1kHz frequency signal together with the tracking filter in Univox FSM 2.0 make measurements below the background noise level possible. Procedure 1. Press Start to activate program 2 Coverage 2. Connect the signal source and activate the audio file 1kHz.wav. 3. Adjust the input level according to the amplifier's manual. 4. Adjust the field strength to approximately -12dB at a reference measuring point. 5. Measure the variation (field strength deviation) inside the listening area at 1.2m for sitting and/or 1.7m for standing height. If both sitting and standing positions are used, measure at 1.45m. 6. If necessary, measure the overspill distribution outside of the loop (as overspill is not regulated in the IEC 60118-4 standard, the overspill can be defined as magnetic field above -32dB). IEC 60118-4 Stated field strength variation is ±3dB within the listening volume. 8

3. Basic frequency test (FQ) Description Univox FSM 2.0 automatically calculates the levels for 100Hz and 5kHz relative to 1kHz. The level for measurement is set automatically. As all three frequencies are presented simultaneously (multi-frequency test) the old measurement problem with AGC-systems is solved. Another advantage is the speed. Full measurement with all frequencies is made approximately once every second. Note 1 High frequency drop is caused by construction metal in the room. The highest drop will normally occur in the middle of the loop. Note 2 A loop amplifier cannot fully compensate for high frequency drops as the variation is due to the physical variation of the room, not the amplifier. The only real solution is to decrease the distance between the loop wires to reduce the metallic influence. Tone controls (often called metal loss correction or alike) cannot control local frequency variation caused by the room. After any frequency adjustment(s), double-check that the.amplifier does not saturate/clip AND that it can deliver the full 400 ma/m (0dB) in program peaks. Procedure 1. Press start to activate program 3 FQ. 2. Activate the audio file 3_freq.wav. 3. Adjust the input level according to the amplifier's manual. 4. Make sure that the output does NOT saturate or clip. -12dB field strength level is a secure level (the -12dB level is normally already set in step 2). 5. Perform the frequency test at 1.2m for sitting and 1.7m for standing listening height. If both sitting and standing positions are used, measure at 1.45m. 6. Document the results in the certificate. The 1kHz db value will always be set to 0dB. The 100Hz and 5kHz db values will be measured in relation to the 0dB at 1kHz. IEC 60118-4 Specified frequency variation is ±3dB for 100Hz and 5kHz relative to 1kHz (0dB). 9

4. Comprehensive frequency measurement (not required for IEC certificate) (Freq) Description Univox FSM 2.0 makes a full automatic frequency/spectrum measurement without the need for manual calibration or setting of the level of the measurement. This also avoids common mistakes when trying to set correct levels for frequency measurements. The program makes relative frequency measurements possible with accurate results. 1. Each frequency is measured. 2. The gain is calculated and corrected for each frequency for highest dynamic range. 3. The highest measured level is calculated. 4. All other frequency levels are in relation (-db) to the frequency with the highest measured level. 5. Frequency levels are presented as bar graphs on the lower display with 1dB resolution (total 8dB). 6. The field strength level is presented on the upper right of the display (normally approx. -12dB). Procedure 1. Activate the audio file 16_freq.wav. 2. Make sure that the output does NOT saturate or clip. -12dB field strength level is a secure level (the -12dB level is normally already set in step 2). 3. Check the frequency variation at 1.2m for sitting and 1.7m for standing height. At installations for sitting audience only, measurement at 1.7m is not necessary. Adjustments High frequency drop is caused by the construction metal in the room. The highest drop will normally be in the middle of the loop. Important! Any high frequency corrections strongly increase the saturation/clipping risk in 10

the amplifier. A 12dB increase in correction increases the power demand from the amplifier by 16 times! Any high frequency correction made at a low level (-12dB/100 ma/m) will LIKELY saturate the amplifier for normal program signal peaks of 400 ma/m. Frequency measurements are not correlated to the field strength. The output performance must be checked after any frequency corrections. 5. Adjustment of field strength level (Field) Description The FSM 2.0 measures the magnetic field strength level approximately 3 times/sec. Procedure 1. Activate the audio file 1kHz_pulse.wav. 2. Adjust the input level according to the amplifier's manual. 3. Read the highest value within 2-5 seconds and adjust the output current until peak values of 0dB (400mA/m) ±3dB are reached. A good reference measurement position is midway between the center of the loop and the loop perimeter. Note: A continuous sine wave is not recommended since the loop driver s AGC might decrease the level. 4. Check the variation at 1.2m for sitting and 1.7m for standing height. Document the result in the certificate. It is only necessary to document the used height, i.e. if only sitting position is used only that position needs to be documented. 5. As an alternative, activate the audio file itu.wav and read the highest value during min. 30 sec. Adjust the amplifier's output current until peak values of 0dB (400mA/m) ±3dB are reached. IEC 60118-4 Accepted variation is ±3dB re 400mA/m (0dB) through the whole listening volume. 11

6. Final confirmation and commissioning Connect the actual signal source/s, preferably speech, and adjust the input level according to the instructions of the amplifier s manual. If a microphone is used, speak normally into the microphone. If the ITU or HA synthesized speech signals are preferred, use the audio sources available on site (e.g. CD player or audio system). Verify that the highest peak is 400mA/m (0dB). As real signals like speech fluctuate, several measurements have to be performed, usually for 20-30 seconds. The time it will take before an accurate peak value is reached, is depending on the evenness of the program signal (crest factor). Document the highest peak value in the certificate. Another easy way of confirming that the magnetic field strength level is OK, is to use Univox Listener. If the LED lights up green occasionally the level is according to the IEC standard. 7. Voltage clipping in program peaks To ensure that dynamic signals like music is presented more fairly, it has to be verified that 400mA/m (0dB) can be reached in the program peaks also at 1.6kHz. This can be achieved in one of two ways: 1. When using the primary sound source, ensure that the driver is not peak-clipping by observing that the clip/peak indicator doesn t light red. 2. If a primary sound source is not yet present, activate the audio file 1k6Hz_pulse.wav instead and verify that 400mA/m (0dB) can be reached in the program peaks. 12

Connection to external measurement equipment The FSM 2.0 can be connected to external measurement equipment using the headphone output. Output level is 100mV RMS at max volume setting. Max load 1kΩ. Therefore any system computer, level meter, smartphone or alike with appropriate software can use the FSM 2.0 as a field strength measurement "head". General information Security/Warranty Basic knowledge in audio installation techniques is required to achieve existing regulations. The installer is responsible for the installation hereby avoiding any risk or cause of fire. Please also note that warranty is not valid for any damage or defects on the product due to incorrect or incautious handling. Maintenance and care Under normal circumstances Univox products do not need any special maintenance. Should the unit become dirty, wipe the unit with a slightly damp cloth. Do not use solvent or heavy cleaning agents. FSM 2.0 is calibrated upon delivery and there is normally no need for re-calibration. Trouble shooting guide When Univox FSM 2.0 automatically shuts down quickly, please replace the batteries. If the buttons are pressed down too hard, the Univox FSM 2.0 might shut itself off. If so, just activate the FSM 2.0 again by pressing the Start button. To listen to the sound of a loop with earphones, please use the included 3.5mm earphone adapter to receive sound in both ears. 13

Service Should the system still not work after trouble shooting, please contact the local distributor of the product for further instructions. Always enclose a filled out Service Form, see www.univox.eu, Support. Technical data For additional information, please refer to product data sheet/brochure and CE certificate which can be downloaded from www.univox.eu. If required, spare part lists or other technical documents can be ordered through support@edin.se. Recycling directives/environment/correct disposal When this product is finished with, please follow existing disposal regulations. Thus if you respect these instructions you ensure human health and environmental protection. 14

Notes 15

Distributor Univox by edin, the world s leading expert and producer of high quality hearing loop systems, created the very first true loop amplifier 1969. Ever since our mission is to serve the hearing community with the highest degree of service and performance with strong focus on Research and Development for new technical solutions. Bo Edin AB, Stockby Hantverksby 3, SE-181 75 Lidingö, Sweden www.univox.eu fsm-2-0-du-gb-150424 Copyright Bo Edin AB Hearing excellence since 1965 16