Electronic timer CT-TGD.22

Similar documents
Electronic timer CT-SDD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Electronic timer CT-MFS.21

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Power supply CP-D 24/1.3

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-E 24/0.75

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relay

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Power supply CP-E 24/2.5

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Power supply CP-E 24/2.5

Three-phase monitoring relays CM-PFE and CM-PFE.2

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 24/20.0

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Three-phase monitoring relay

Three-phase monitoring relay CM-PBE

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Three-phase monitoring relay CM-PFS

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Power supply CP-D 12/2.1

Three-phase monitoring relay CM-PVE

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Liquid level monitoring relay CM-ENS.2x

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-SDE

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Power supply CP-D 24/4.2 Primary switch mode power supply

Control module CP-A CM

Power supply CP-T 24/40.0 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Primary switch mode power supplies Product group picture

CP-T range Product group picture

CP-E range Benefits and advantages

Power supply CP-T 48/20.0 Primary switch mode power supply

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Power supply CP-T 24/20.0 Primary switch mode power supply

CP-T range Benefits and advantages

Analog signal converters CC-E I/I

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Control module CP-A CM

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Three-phase monitoring relays Product group picture

Analog signal converters CC range

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

05/09/2012

Thermistor motor protection relays

Switching power supplies CP range, Linear power supplies CP-L range. Content

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Subject to changes 11/2003 Page 1/7

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Zelio Control Measurement Relays

Thermistor motor protection relays

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Transcription:

2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection of the time range of the OFF time d Potentiometer with direct reading scale for the fine adjustment of the OFF time e U: green LED V control supply voltage applied W timing f R: yellow LED V output relays energized g Function diagram Features Rated control supply voltage 24 48 V DC, 24 240 V AC Single function timer pulse generator 2 x 7 time ranges (0.05 s 100 h) in one device 2 c/o contacts (250 V / 5 A) Control input: voltage related triggering, polarized, capable of switching a parallel load 2 LEDs for status indication Width of only 17.5 mm Light grey enclosure in RAL 7035 Approvals A UL 508, CAN/CSA C22.2 No.14 D GOST K CB scheme pending E CCC pending Marks a CE b C Tick pending Order data Type CT-TGD.22 Rated control supply voltage 24 48 V DC, 24 240 V AC Time range Output Control input 2 x 0.05 s 100 h 2 c/o contacts voltagerelated triggering Order code Application With their structural form and their width of 17.5 mm only, the CT D range timers are ideally suited for installation in distribution cabinets. Operating mode The CT TGD.22 has 2 c/o contacts and provides 2 independent timing circuits, one for adjustment of the ON time and one for adjustment of the OFF time. Two rotary switches, on the front of the unit, allow selection of one of 7 time ranges from 0.05 s to 100 h for each time delay. The fine adjustment of the time delay is made via an internal potentiometer, with a direct reading scale, on the front of the unit.

Function diagram(s) DE Pulse generator, starting with ON or OFF This function requires continuous control supply voltage for timing. Applying control supply voltage, with open control input A1 Y1/B1, starts timing with an ON time first. Applying control supply voltage, with closed control input A1 Y1/B1, starts timing with an OFF time first. The ON & OFF times are displayed by the flashing green LED, which flashes twice as fast during the OFF time. The ON & OFF times are independently adjustable. If control supply voltage is interrupted, the output relay de energizes and the time delay is reset. A1-A2 A1-Y1/B1 15-18, 25-28 15-16, 25-26 green LED t1 t2 t2 t1 2CDC 252 111 F0206 t1 = adjusted OFF time t 2 = adjusted ON time Connection diagram(s) A1 Y1/ B1 A1 15 15 25 25 A2 16 18 26 28 18 16 Y1/B1 28 26 A2 2CDC 252 118 F0b06 15 16/18 1. c/o contact 25 26/28 2. c/o contact A1 A2 Rated control supply voltage U S 24 48 V DC or 24 240 V AC A1 Y1/B1 Control input Wiring instructions Parallel load to control input possible / allowed L(+) A1 Y1/B1 2CDC 252 102 F0b06 A2 N(-) 2

Technical data Data at T a = 25 C and rated values, if nothing else indicated Input circuits - Supply circuit Rated control supply voltage U S A1 A2 24 240 V AC A1 A2 24 48 V DC Rated control supply voltage tolerance 24 240 V AC 15...+10 % 24 48 V DC 15...+10 % Typical current / power consumption 24 V DC 230 V AC 115 V AC 24 48 V DC 26.20 ma / / / 24 240 V AC / 33.20 ma / 19.90 ma / Rated frequency Frequency range AC Power failure buffering time DC; 50/60 Hz 47 63 Hz min. 30 ms Input circuits - Control circuit Control input, control function A1 Y1/B1 start timing external Kind of triggering voltage related triggering Resistance to reverse polarity Polarized Capable of switching a parallel load Maximum cable length to the control inputs Minimum control pulse length Control voltage potential yes yes yes 50 m 100 pf/m 30 ms see rated control supply voltage U S Current consumption of the control input 24 V DC 0.912 ma 230 V AC 6.417 ma 115 V AC 3.254 ma Timing circuit Kind of timer Single function timer Pulse generator, starting with ON or OFF Time ranges 0.05 s 100 h Recovery time Accuracy within the rated control supply voltage tolerance Accuracy within the temperature range Indication of operational states 0.05 1 s, 0.5 10 s, 5 100 s, 0.5 10 min, 5 100 min, 0.5 10 h, 5 100 h < 50 ms Δt < 0.005 %/V Δt < 0.06 %/ C Control supply voltage / timing U: green LED V: control supply voltage applied Control supply voltage / timing U: green LED W: timing Relay status R: yellow LED V: output relay energized Output circuits Kind of output 15 16/18 Relay, 1. c/o contact 25 26/28 Relay, 2. c/o contact Contact material Rated operational voltage U e Derating Cd free 250 V 3

Output circuits Minimum switching voltage / Minimum switching current 12 V / 100 ma Maximum switching voltage / Minimum switching current see load limit curve / see load limit curve Rated operational current I e (IEC 60947 5 1) AC12 (resistive) at 230 V 5 A AC15 (inductive) at 230 V 3 A Mechanical lifetime Electrical lifetime Short circuit resistance, maximum fuse rating (IEC/EN 60947 5 1) DC12 (resistive) at 24 V DC13 (inductive) at 24 V n/c contact n/o contact 5 A 2 A 30 x 10 6 switching cycles 0.1 x 10 6 switching cycles (AC12, 230 V, 4 A) 6 A fast acting 10 A fast acting General data Duty time 100 % Repeat accuracy (constant parameters) Δt <± 0.5 % Dimensions (W x H x D) Weight Mounting position Minimum distance to other units 17.5 x 80 x 58 mm (0.69 x 3.15 x 2.28 inches) approx. 65 g (approx. 0.14 lb) normal operation mode horizontal none vertical Mounting DIN rail (EN 60715), snap on mounting without any tool Degree of protection enclosure / terminals IP50 / IP20 any none Electrical connection all circuits Wire size Stripping length Tightening torque fine strand with wire end ferrule fine strand without wire end ferrule Screw connection 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) 2 x 0.5 1.5 mm 2 / 1 x 0.5 2.5 mm 2 (2 x 20 16 AWG) / (1 x 20 14 AWG) rigid 2 x 0.5 1.5 mm 2 / 1 x 0.5 4 mm 2 (2 x 20 16 AWG) / (1 x 20 12 AWG) 7 mm (0.28 inches) 0.5 0.8 Nm Environmental data Ambient temperature range operation 20...+60 C storage 40...+85 C Damp heat, cyclic (IEC/EN 60068 2 30) Vibration, sinusoidal (IEC/EN 60068 2 6) Shock, half sine (IEC/EN 60068 2 27) 6 x 24 h cycles, 55 C, 95 % RH 4 m/s 2, 20 cycles, 10...150...10 Hz 100 m/s 2, 11 ms Isolation data Rated isolation voltage U i Output circuit 1 / Output circuit 2 300 V Input circuit / Output circuit 300 V 4

Isolation data Rated impulse withstand voltage U imp (type test) (IEC/EN 60664 1, VDE 0110) Power frequency withstand voltage test (Test voltage, routine test) between all isolated circuits 4 kv; 1.2/50 µs between all isolated circuits 2.5 kv, 50 Hz, 1 s Basic insulation (IEC/EN 61140) Input circuit / Output circuit 300 V Protective separation (IEC/EN 61140, VDE 0106 part 101 and part 101/A1) Pollution degree (IEC/EN 60664 1, VDE 0110, UL 508) Overvoltage category (IEC/EN 60664 1, VDE 0110, UL 508) Input circuit / Output circuit 250 V 3 III Standards / Directives Product standard EMC Directive Low Voltage Directive RoHS Directive IEC 61812 1, EN 61812 1 + A11, DIN VDE 0435 part 2021 2004/108/EC 2006/95/EC 2002/95/EC Electromagnetic compatibility Interference immunity IEC/EN 61000 6 1 IEC/EN 61000 6 2 electrostatic discharge (ESD) IEC/EN 61000 4 2 Level 3 (6 kv / 8 kv) electromagnetic field (HF radiation resistance) IEC/EN 61000 4 3 Level 3 (10 V/m) fast transients (Burst) IEC/EN 61000 4 4 Level 3 (2 kv / 5 khz) powerful impulses (Surge) IEC/EN 61000 4 5 Level 4 (2 kv L L) HF line emission IEC/EN 61000 4 6 Level 3 (10 V) Interference emission IEC/EN 61000 6 3 IEC/EN 61000 6 4 electromagnetic field (HF radiation resistance) IEC/CISPR 22, EN 55022 Class B HF line emission IEC/CISPR 22, EN 55022 Class B 5

Technical diagrams Load limit curve AC voltage [V] resistive load 2CDC 252 122 F0206 DC voltage [V] resistive load 2CDC 252 121 F0206 AC current [A] DC current [A] AC load (resistive) DC load (resistive) Derating factor F Derating factor F 1.0 0.9 0.8 0.7 2CDC 252 124 F0206 0.6 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ for inductive AC load Contact lifetime Switching cycles 250 V resistive load 2CDC 252 123 F0206 Switching current [A] 6

Dimensions in mm 0.69 17,5 0.2 5 58 2.28 43,4 1.71 80 3.15 45 1.77 2CDC 252 130 F0b06 CT-TGD.22 Synonyms Used expression Alternative expression(s) Used expression Alternative expression(s) 2 c/o contacts 1 DPDT / 2 SPDT voltage related wet / non floating Further Documentation Document title Document type Document number Electronic Products and Relays Technical catalogue 2CDC 110 004 C020x You can find the documentation in the internet under www.abb.com/lowvoltage R Control Products R... 7

STOTZ KONTAKT GmbH As part of the on going product improvement, reserves the right to modify the characteristics of the products described in this document. The information given is non contractual. For further details please contact (www.abb.com/contacts) the company marketing these products in your country. Document number: 2CDC 111 063 D0201 (12/2007) Eppelheimer Strasse 82, 69123 Heidelberg, Germany Postfach 10 16 80, 69006 Heidelberg, Germany Internet http://www.abb.com/lowvoltage R Control Products