Alignment control of GEO 600

Similar documents
Thermal correction of the radii of curvature of mirrors for GEO 600

Installation and Characterization of the Advanced LIGO 200 Watt PSL

The VIRGO injection system

Timing accuracy of the GEO 600 data acquisition system

arxiv: v1 [gr-qc] 10 Sep 2007

Experimental Test of an Alignment Sensing Scheme for a Gravitational-wave Interferometer

The VIRGO suspensions

Advanced Virgo commissioning challenges. Julia Casanueva on behalf of the Virgo collaboration

7th Edoardo Amaldi Conference on Gravitational Waves (Amaldi7)

Results from the Stanford 10 m Sagnac interferometer

Interferometer signal detection system for the VIRGO experiment. VIRGO collaboration

Optical generation of frequency stable mm-wave radiation using diode laser pumped Nd:YAG lasers

Virgo status and commissioning results

A review of Pound-Drever-Hall laser frequency locking

How to Build a Gravitational Wave Detector. Sean Leavey

Wave Front Detection for Virgo

Received 14 May 2008, in final form 14 July 2008 Published 11 September 2008 Online at stacks.iop.org/cqg/25/195008

Designing Optical Layouts for AEI s 10 meter Prototype. Stephanie Wiele August 5, 2008

The AEI 10 m Prototype. June Sina Köhlenbeck for the 10m Prototype Team

Multiply Resonant EOM for the LIGO 40-meter Interferometer

The Virgo detector. L. Rolland LAPP-Annecy GraSPA summer school L. Rolland GraSPA2013 Annecy le Vieux

LIGO-P R. High-Power Fundamental Mode Single-Frequency Laser

Back-Reflected Light and the Reduction of Nonreciprocal Phase Noise in the Fiber Back-Link on LISA

The VIRGO detection system

Final Report for IREU 2013

The Florida control scheme. Guido Mueller, Tom Delker, David Reitze, D. B. Tanner

A gravitational wave is a differential strain in spacetime. Equivalently, it is a differential tidal force that can be sensed by multiple test masses.

Alignment signal extraction of the optically degenerate RSE interferometer using the wave front sensing technique

Gravitational-Wave Detection, Mike Cruise, Peter Saulson, Editors, Proceedings of SPIE Vol (2003) 2003 SPIE X/03/$15.

Koji Arai / Stan Whitcomb LIGO Laboratory / Caltech. LIGO-G v1

Polarization Sagnac interferometer with a common-path local oscillator for heterodyne detection

Optical design of shining light through wall experiments

TNI mode cleaner/ laser frequency stabilization system

Pound-Drever-Hall Locking of a Chip External Cavity Laser to a High-Finesse Cavity Using Vescent Photonics Lasers & Locking Electronics

Calibration of the LIGO displacement actuators via laser frequency modulation

This is a brief report of the measurements I have done in these 2 months.

Experience with Signal- Recycling in GEO600

DRAFT Expected performance of type-bp SAS in bkagra

VIRGO. The status of VIRGO. & INFN - Sezione di Roma 1. 1 / 6/ 2004 Fulvio Ricci

Stable Recycling Cavities for Advanced LIGO

Lateral input-optic displacement in a diffractive Fabry-Perot cavity

Modeling and Commisioning of the 10m Prototype Autoalignment System

Readout and control of a power-recycled interferometric gravitational wave antenna

Optical Recombination of the LIGO 40-m Gravitational Wave Interferometer

Mystery noise in GEO600. Stefan Hild for the GEO600 team. 14th ILIAS WG1 meeting, October 2007, Hannover

ADALAM Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing D2.2. Ger Folkersma (Demcon)

Periodic Error Correction in Heterodyne Interferometry

Testbed for prototypes of the LISA point-ahead angle mechanism

Analog phase lock between two lasers at LISA power levels

Lasers for LISA: overview and phase characteristics

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Stability of a Fiber-Fed Heterodyne Interferometer

Universal and compact laser stabilization electronics

Development of Optical lever system of the 40 meter interferometer

Deep phase modulation interferometry for test mass measurements on elisa

Commissioning of Advanced Virgo

Michelson interferometer with diffractively-coupled arm resonators in second-order Littrow configuration

Measurement of optical response of a detuned resonant sideband extraction gravitational wave detector

9) Describe the down select process that led to the laser selection in more detail

CO2 laser heating system for thermal compensation of test masses in high power optical cavities. Submitted by: SHUBHAM KUMAR to Prof.

A simple high-sensitivity interferometric position sensor for test mass control on an advanced LIGO interferometer

Timing Noise Measurement of High-Repetition-Rate Optical Pulses

LIGO II Photon Drive Conceptual Design

Length sensing and control of a Michelson interferometer with power recycling and twin signal recycling cavities

Optical Vernier Technique for Measuring the Lengths of LIGO Fabry-Perot Resonators

Control Servo Design for Inverted Pendulum

The Pre Stabilized Laser for the LIGO Caltech 40m Interferometer: Stability Controls and Characterization.

Angular control of Advanced Virgo suspended benches

An optical transduction chain for the AURIGA detector

Linewidth-broadened Fabry Perot cavities within future gravitational wave detectors

arxiv: v1 [astro-ph.im] 19 Dec 2011

LISA and SMART2 Optical Work in Europe

Using a Negative Impedance Converter to Dampen Motion in Test Masses

Kit for building your own THz Time-Domain Spectrometer

Physics of interferometric gravitational wave detectors

10W Injection-Locked CW Nd:YAG laser

Diffractive gratings. in high-precision interferometry. for gravitational wave detection

Alignment sensing for optical cavities using radio-frequency jitter modulation

Angular Drift of CrystalTech (1064nm, 80MHz) AOMs due to Thermal Transients. Alex Piggott

Wavelength Control and Locking with Sub-MHz Precision

1.6 Beam Wander vs. Image Jitter

ISC RF Photodetector Design: LSC & WFS

Improving seismic isolation in Advanced LIGO using a ground rotation sensor

Experiment begins this autumn. This Talk: Motivation for TAMA300 recycling Length sensing/control system Lock acquisition

Use of single-mode optical fiber in the stabilization of laser frequency

Method of Power Recycling in Co-Axial Mach Zender Interferometers for Low Noise Measurements

DIODE lasers have some very unique qualities which have

Spatial Uniformity of Silicon Photodiodes at Radio Frequencies

la. Smith and C.P. Burger Department of Mechanical Engineering Texas A&M University College Station Tx

RF System Models and Longitudinal Beam Dynamics

visibility values: 1) V1=0.5 2) V2=0.9 3) V3=0.99 b) In the three cases considered, what are the values of FSR (Free Spectral Range) and

Readout and control of a power-recycled interferometric gravitational-wave antenna

Gravitational Wave Detection and Squeezed Light

Active cancellation of residual amplitude modulation in a frequency-modulation based Fabry-Perot interferometer

LIGO-P R Detector Description and Performance for the First Coincidence Observations between LIGO and GEO

Arm Cavity Finesse for Advanced LIGO

MAGNETIC LEVITATION SUSPENSION CONTROL SYSTEM FOR REACTION WHEEL

PRM SRM. Grav. Wave ReadOut

Advanced Virgo Technical Design Report

A Fast Phase meter for Interferometric Applications with an Accuracy in the Picometer Regime

Transcription:

INSTITUTE OF PHYSICS PUBLISHING Class. Quantum Grav. 1 (4) S441 S449 CLASSICAL AND QUANTUM GRAVITY PII: S64-9381(4)683-1 Alignment of GEO 6 HGrote 1, G Heinzel 1,AFreise 1,SGoßler 1, B Willke 1,HLück 1, H Ward, M M Casey, K A Strain, D I Robertson, J Hough and K Danzmann 1 1 Max-Planck-Institute for Gravitational Physics (Albert-Einstein-Institute) and University of Hannover, Callinstr. 38, D-3167 Hannover, Germany Department of Physics and Astronomy, University of Glasgow, Glasgow G1 8QQ, UK E-mail: hrg@mpq.mpg.de Received 8 August 3 Published 3 February 4 Online at stacks.iop.org/cqg/1/s441 (DOI: 1.188/64-9381/1/5/9) Abstract We give an overview of the automatic mirror alignment system of the gravitational wave detector GEO 6. In order to achieve the required sensitivity of the Michelson interferometer, the axes of interfering beams have to be superimposed with a residual angle of the order 1 8 rad. The beam spots have to be centred on the mirrors to minimize coupling of alignment noise into longitudinal signals. We present the actual topology and results from the system in operation, which s all alignment degrees of the power-recycled Michelson. With this system continuous lock stretches of more than 11 h duration were achieved. PACS numbers: 4.8.Nn, 7.6.Ly, 95.55.Ym (Some figures in this article are in colour only in the electronic version) 1. Introduction Any interferometer can work correctly only if the interfering beams are properly aligned. Even in small-scale (e.g., table-top) experiments, acquisition of initial alignment and compensation of various drifts are challenging tasks for the experimentator. For large-scale interferometers such as GEO 6 [1] with its mirrors suspended as multiple pendulums which need to maintain their alignment for weeks, an automatic alignment system is indispensable. The cavity- and beam-steering mirrors within the vacuum system are suspended as pendulums for the purpose of seismic isolation. While this gives good attenuation of longitudinal and angular motions of the suspended components in the measurement band for gravitational waves (5 Hz 5 khz), the motions are enhanced at the pendulum resonance frequencies (typically around 1 Hz) and the components are subject to drifts. The most important task of an automatic angular alignment system is to superimpose the propagation axes of interfering beams. The axes of optical cavities have to match the axes of their input beams and the beam axes of the two long Michelson arms have to match each other at the Michelson output port. In particular, the 64-9381/4/5441+9$3. 4 IOP Publishing Ltd Printed in the UK S441

S44 HGroteet al superposition of beam axes minimizes coupling of beam alignment and geometry fluctuations into light power. The second goal of an automatic alignment system is to centre all beam spots on mirrors in order to minimize coupling of mirror alignment noise into longitudinal signals. Control signals for these alignment tasks are obtained by two methods within GEO 6: for superimposing two beam axes we use the differential wavefront sensing (, see, e.g., [ 4]) technique, which senses the angles between interfering wavefronts. Beam axes have to be superimposed in the cases of the two GEO 6 modecleaners, the power-recycling cavity, the Michelson interferometer and the signal-recycling cavity. To beam spot positions on mirrors, the small fraction of light that is transmitted through the mirror is detected by a spot position sensing device, for example a quadrant photodiode. In this paper we briefly describe the standard sensing setup used in GEO 6 with the example of a GEO modecleaner. The design and operation of a feedback loop is shown in some detail for the case of the Michelson interferometer, and a brief overview of the computer system is given. Throughout this paper the terms yaw and pitch are used to describe angular degrees of freedom of a mirror. A mirror yaw motion results in a horizontal misalignment of a reflected beam, while a pitch motion changes the vertical direction of a reflected beam.. Automatic alignment of a GEO 6 modecleaner GEO 6 uses two sequential triangular modecleaners [5] with each cavity mirror being suspended individually by a double pendulum structure. Figure 1 shows the experimental setup for the automatic alignment system of the first modecleaner of GEO 6. The laser beam incident on MMC1a is phase modulated with a radio frequency of 5. MHz by the electro-optic modulator EOM1, to allow the use of the Pound Drever Hall [6] locking and differential wavefront sensing. The free spectral range of MC1 is 37.48 MHz (37.16 MHz for MC) such that the sidebands at 5.5 MHz from the carrier are off resonance. Beam E i + E c leaving mirror MMC1a (downwards in figure 1) consists of the interfering fields of the directly reflected part of the input beam (E i ) and the field leaking out of the cavity (E c ). For the Pound Drever Hall sensing, the phase difference between the wavefronts of E i and E c is read out over the whole cross section of the interference pattern. The resulting signal is a measure for the match between the incident laser frequency and one of the cavity resonant frequencies. Usually an appropriate feedback loop is used to keep the difference of these frequencies close to zero, what is referred to as locking of the cavity. If the cavity is locked (which is assumed for all following discussions), the method can measure the angle between the wavefronts of E i and E c by using a split photodiode and calculating the difference between the two demodulated photocurrents of the different photodiode sections. With a quadrant photodiode this can be done for the horizontal and vertical directions simultaneously. Due to the properties of Gaussian beams, the angle between the wavefronts is generally not identical with the angle between the axes of beams E i and E c. But if the wavefront angles are measured at two different distances from the beam waist (which is located between mirrors MMC1a and MMC1c, see figure 1), four different quantities can be obtained, giving full information about angular and parallel displacements of the cavity axis against the axis of the incoming beam. Following this scheme, beam E i + E c in figure 1 is split into two paths by the power beamsplitter BS1 which has a transmission of about 5%. The components G1 and G are galvanometer scanners with the purpose of centring the beams on the quadrant photodetectors D1 and D, respectively. The corresponding loops have a bandwidth of about 1 khz

Alignment of GEO 6 S443 MMC1b MMC1c PDAMC1 MMC1a E + E i c BDIMC1 Centring G1 BS1 D1 G A A1 M1 L L1 M D EOM1 Centring 5.MHz from laser Figure 1. Schematic overview of the alignment for one modecleaner. Details of the purpose of lenses L1 and L, galvanometer scanners G1 and G, photodiodes D1 and D, mixers M1 and M and adders A1 and A are given in the text. The numbers next to the boxes denote the number of degrees of freedom led by each path. and are denoted the centring. The centring loops ensure correct signals over a large dynamic range of the initial and residual alignment deviation. Lenses L1 and L in the light path to D are used to project beam E i + E c into the far field (i.e., adjust an additional Guoy phase shift between the TEM and TEM 1/1 modes close to 9 ). Each of the detectors D1 and D consists of a quadrant photodiode with associated electronics to yield information about the beam spot position, while the angle between the interfering wavefronts (the signal) is available after coherent demodulation of the RF component from each quadrant s photocurrent performed by mixers M1 and M. Appropriate linear combinations of the signals are then processed by analogue electronic circuits A1 and A, to generate feedback signals to individual mirrors. Amplified with an appropriate gain and frequency response, these signals are fed back to mirrors MMC1a, MMC1b and MMC1c. Currently we use feedback by analogue electronics with a bandwidth around. Hz. The dashed lines show slow digital feedback loops being used for the spot position. The spot position on mirror MMC1b is led by feeding back the PDAMC1 signals to steering mirror BDIMC1, keeping the beam centred on mirror MMC1b (this is possible, as the has a higher bandwidth than the spot position, such that the cavity axis follows the axis of the incident beam). The direction of the beam E i + E c yields a

S444 HGroteet al MFn MCn PDAPR BDIPR MFe PDPR E i +E c MU3 MPR BS PDO MCe BDOMC Figure. Schematic overview of the alignment for the power-recycling cavity and Michelson interferometer. PDPR detects the light reflected from MPR and represents a complete alignment sensing setup for four degrees of freedom, while detector PDO at the Michelson output port represents a sensing system for two degrees of freedom. The spot position topology shown is a simplified version. signal for the two remaining degrees of freedom of the three cavity mirrors. As this beam is centred on D1 by G1 with high bandwidth (1 khz), the information about the direction of beam E i + E c is contained in the feedback to G1. This information is fed back to MMC1a and MMC1c by another spot position loop. The alignment setup for the second GEO 6 modecleaner is identical (except for a phase modulation frequency of 13 MHz instead of 5.5 MHz, which is applied by another EOM in the beam path between MC1 and MC). The complete modecleaner alignment system is supervised by computer programs based on LabView (see section 3.1 for the similar Michelson ), which enables long-term stable operation of the modecleaners without human intervention being required. More details about the modecleaner alignment system (e.g., about the quadrant sensor design and the servo design and performance) can be found in [7]. 3. Automatic alignment of the power-recycled Michelson Figure gives a brief overview of the alignment system for the power-recycled Michelson interferometer (without signal recycling). The Michelson interferometer consisting of beamsplitter BS, folding mirrors MFe, MFn, and end mirrors MCe and MCn forms the power-recycling cavity together with the power-recycling mirror (MPR). In a simple scenario the power-recycling cavity can be seen as a two-mirror cavity, consisting of MPR and the Michelson operating at the dark fringe. This

Alignment of GEO 6 S445 cavity has four alignment degrees of freedom determining the beam axis of the power-recycling cavity against the input beam. Although we have an east and north arm of the Michelson, the axis of the power-recycling cavity between MPR and BS is given by the average position of the two beam axes in the long arms. The most important alignment task for the power-recycling cavity is to superimpose the power-recycling cavity axis (simply called the cavity axis here) on the axis of the beam incident on MPR from the west (called the input axis). The input axis is defined by the alignment of mirrors BDOMC and BDIPR. Superimposing these axes is done with the differential wavefront sensing method, sensing the beam reflected from MPR. The light incident on the power-recycling cavity via BDOMC and BDIPR is partly reflected by MPR and interferes with the beam leaking out of the power-recycling cavity. The combined beam E i + E c is extracted by a Faraday isolator on the suspended mounting unit MU3 [8] and detected by PDPR. Detector PDPR represents a complete alignment setup for four degrees of freedom similar to the setup for one modecleaner. The feedback for the power-recycling cavity is applied by a set of coil/magnet actuators mounted at the mirror level of the steering mirror BDIPR and the power-recycling mirror. The performance of this feedback system with a bandwidth of 1 Hz has been shown in [9]. If the feedback system for the power-recycling cavity is working, there are two degrees of freedom left to be led by differential wavefront sensing. The beam axes of the east and north arm have to be superimposed at the main output of the Michelson, south of the beamsplitter, which is referred to as Michelson alignment. Michelson alignment deviations and fluctuations result in a contrast degradation of the dark fringe, which leads to power loss, a smaller Michelson signal (containing the differential length information), and larger couplings of various noise sources to the Michelson signal. The actuators used for ling the Michelson alignment are MCe and MCn in a differential alignment mode, which does not affect the alignment of the power-recycling cavity. All mirrors that are a part of the Michelson are suspended as triple pendulums with the possibility of applying slow alignment at the highest mass in the suspension chain. In addition to this, MCe and MCn are equipped with another triple pendulum suspension chain, mounted in parallel with the mirror chain, providing a seismically isolated reaction mass system with coil/magnet actuators at the mass above the mirror ( intermediate mass ), and electrostatic drives at the mirror level. Because of the limited alignment range of the electrostatic drives (to date about 1 9 rad at 1 Hz), we currently use only the intermediate mass (IM) feedback for the Michelson alignment. Alignment feedback by the electrostatic drives will be added to this, when the Michelson signal has reached its final low noise level. The loop filters for the IM feedback have to provide about of phase lead around the unity gain frequency of 1 Hz, to yield a stable feedback system. As the gain of these filters above 1 Hz can be very high, care has to be taken concerning saturation of these filters. Figure 3 shows the simulated open loop gain and phase of the initial implementation of the Michelson fast autoalignment for pitch (the filter- and actuator-transfer function combined). A unity gain frequency of about 1 Hz can be achieved with this design. The loop is only stable and robust for unity-gain frequencies between 5 and 1 Hz. As the resonance frequencies do not differ much between MCe and MCn, only one filter was used, to pitch (and another filter to yaw) of both mirrors. After the Michelson is locked longitudinally, the Michelson fast feedback can be switched on. However, without additional care, the acquisition of the fast feedback is critical. If the deviation from perfect Michelson alignment at the moment of closing the alignment loop is too large, locking of the alignment loop is not achieved as the

S446 HGroteet al 5 4 3 Amplitude Phase 135 9 Amplitude [db] 1-1 - -3 45-45 -9-135 Phase [Degree] -4.1 1 1 Frequency [Hz] -18 Figure 3. Simulated open loop gain and phase of the Michelson fast autoalignment for pitch..5.4 G1:LSC_MID_VIS Ampl [V].3..1 4 6 8 1 1 14 t [s] 1.5 Ampl [V] 1.5 G1:LSC_BS_PWR EAST 4 6 8 1 1 14 t [s] Figure 4. Time series of Michelson interferometer power levels with the Michelson switched on around t = 1 s. The upper trace shows the light power at the Michelson output port, the lower trace displays the power in the east arm of the Michelson. Without autoalignment, the interferometer is almost unstable in this configuration. Michelson alignment gets disturbed too much during initial alignment oscillations, such that the longitudinal lock is lost. For acquiring lock safely, it is advantageous to switch the Michelson feedback on at the same time as the longitudinal feedback at the intermediate mass stage is switched on. Additionally, the gain of the Michelson loop is ramped by hardware from zero to its

Alignment of GEO 6 S447 LabView VI ADC digital loop filter ( slow dig. loop / automatic prealign) LabView VI set gain digital loop filter (offset shifting loop) Handy program (manual prealign) switch ADC coarse DAC + + analog loop filter fine DAC coil/magnet actuator at intermediate mass coil/magnet actuator at upper mass ESD actuator at mirror level sensor optical system Figure 5. Integration of the LabView-based computer with the system for the Michelson alignment. Depending on the detector state, the feedback is switched on and off automatically. nominal value over approximately 1 s, to enable a soft acquisition of the system (for this short period the loop remains stable even with low gain). For a stable operation of the Michelson feedback, with a bandwidth around 1 Hz, it was necessary to implement notch filters for the vertical suspension modes around and 3 Hz, which otherwise lead to instability. Further critical parameters for the stability of the Michelson feedback are the beam spot positions on the four end mirrors. In particular, the spot positions on mirrors MCe and MCn are important, as these mirrors are used for the feedback. If a spot is not centred on a mirror here, the coupling of angular mirror motions (e.g., caused by the feedback) to longitudinal displacement is altered. If the bandwidth of the Michelson longitudinal feedback loop is low, there can be a coupled oscillation of the and longitudinal feedback loop. Only after these spot positions were fixed by spot position loops could continuous locking times exceed many hours. Figure 4 shows a time series of the light power at the dark port (upper trace) and the power in the east arm of the Michelson (lower trace). At t = 1 s the alignment feedback of the Michelson is switched on. The remaining Michelson alignment noise with feedback active corresponds to roughly 5 1 8 rad. This needs to be improved by a factor of 5, in order to meet the required alignment noise limit of 1 1 8 rad. However, it is not expected to be difficult to reach this goal once the electrostatic drives are used for feedback in conjunction with the coil/magnet feedback at the intermediate masses.

S448 HGroteet al BS Alignment Feedback [µ rad.] 5 4 3 1 1 BS:ROT:FINEOFFSET 5 1 15 t [d] Temperature at TCE [Deg.C] 6 5.5 5 EMON:TEMP:CB/C_TCE 5 1 15 t [d] Figure 6. Beamsplitter yaw alignment feedback (top) and central cluster temperature (bottom) over 16 days of the S1 run. 3.1. Computer A computer system based on LabView is used to monitor signals of the analogue electronics by means of programs called virtual instruments (VI) [1]. The gains of the servo loops can be set with this system and the feedback loops can be switched on and off automatically, depending on the state of the detector. The spot position s (as shown by the dashed lines in figure ) are implemented as digital feedback loops with a bandwidth around.1 Hz by virtual instruments as well. Figure 5 gives an overview of the VIs ling the Michelson feedback. Manual coarse alignment of each mirror is done with a dedicated VI, applying offsets to the upper mass of the suspension chain. These offsets are not altered during normal operation. For test purposes, the Michelson feedback can be used in a digital only mode with low bandwidth. In the standard mode, however, the analogue feedback applied to the intermediate mass is monitored and held close to zero, by adding digitally led offsets with high resolution to the upper mass stage ( offset shifting loop ). This split feedback system enhances the dynamic range and ensures a close to perfect aligned interferometer even after a loss of lock, when the analogue feedback is switched off. 3.. Long-term operation During the data taking run in August/September ( S1 run), the interferometer was continuously operated for 16 days with a duty cycle of more than 98%. With the exception of a severe misalignment caused by an earthquake in Italy, the Michelson could relock automatically after losses of lock. As an example of the free mirrors alignment motion, figure 6 shows the beamsplitter yaw alignment feedback (top) and the central cluster temperature (bottom) during this period. The alignment fluctuations of the virtually

Alignment of GEO 6 S449 unled mirror (measured by the applied feedback) are about 5 µrad pp. Without alignment this would lead to a spot position deviation of 6 mm pp on the far end mirrors MCe and MCn. It can be seen that the alignment signal is strongly dominated by the temperature in the central cluster, which is dominated by a period of 4 h. 4. Conclusion The complete automatic alignment system for the two suspended ring-type modecleaners and the power-recycled Michelson interferometer of GEO 6 is installed and successfully operating. The modecleaners have been in nearly continuous operation since spring 1 and have required almost no manual mirror alignment. GEO s power-recycled Michelson interferometer is equipped with a complete automatic alignment system ling the two alignment degrees of freedom for each suspended mirror. This alignment system has been found to be indispensable for stable detector operation. During the S1 data taking run in August, a duty cyle of more than 98% was obtained with the longest continuous stretch of lock of more than 11 h duration. Further, the alignment system reduces the coupling of various noise sources (such as, e.g., laser power noise) into the gravitational wave signal. Acknowledgments The authors would like to thank PPARC in the UK, the BMBF and the state of Lower Saxony in Germany. We also thank the whole GEO 6 team for support of this work. References [1] Willke B et al The GEO 6 gravitational wave detector Class. Quantum Grav. B 19 1377 87 [] Morrison E, Meers B J, Robertson D I and Ward H 1994 Automatic alignment of optical interferometers Appl. Opt. 33 541 9 [3] Heinzel G, Rüdiger A, Schilling R, Strain K A, Winkler W, Mizuno J and Danzmann K 1999 Automatic beam alignment in the Garching 3-m prototype of a laser-interferometric gravitational wave detector Opt. Commun. 16 31 34 [4] Heinzel G 1999 Advanced optical techniques for laser-interferometric gravitational-wave detectors PhD Thesis University of Hannover (also available as MPQ report 43) pp 141 6 [5] Goßler S et al 3 The GEO 6 mode-cleaning and injection optics Rev. Sci. Instrum. 74 3787 [6] Drever R W P, Hall J L, Kowalski F V, Hough J, Ford G M, Munley A J and Ward H 1983 Laser phase and frequency stabilisation using an optical resonator Appl. Phys. B 31 97 15 [7] Grote H et al 3 Automatic beam alignment for the modecleaner cavities of GEO 6 Appl. Opt. at press [8] Freise A et al Performance of a 1 m long suspended optical cavity Class. Quantum Grav. B 19 1389 97 [9] Grote H et al The automatic alignment system of GEO 6 Class. Quantum Grav. B 19 1849 55 [1] Casey M M, Ward H and Robertson D I Computer monitoring and of the GEO 6 gravitational wave detector Rev. Sci. Instrum. 71 391 7