Utility Communications Teleprotection Equipment TPT-200

Similar documents
SWT 3000 Teleprotection technical data siemens.com

Power Network Telecommunication. SWT 3000 protection signaling equipment. Answers for energy.

satech SynchroStar GPS 200 Series

PLC-K506 Series FEATURES DESCRIPTION FEATURES

KNC-PLC-K506 Series FEATURES DESCRIPTION FEATURES

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

Overcurrent Protection / 7SJ45

ALP-UDR Universal Detection Relay user-defined protection, automation, and monitoring

SPECIFICATION FOR OVERCURRENT RELAYS

SIPROTEC easy 7SJ46 Numerical Overcurrent Protection Relay

Power Meter Series PM3200 Functions and characteristics

IRIG-B Interface (De-modulated) External clock synchronization signal IRIG format B00X

SUPPLY OF CARRIER PROTECTION COUPLER TYPE NSD-50

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Saitel DP. Technical Specifications Tables. The high-performance platform for applications of control and automation. July 2014

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

SOLUTIONS FOR AN EVOLVING WORLD RFL Programmable FSK Powerline carrier system

INDUSTRIAL+COMMERCIAL ZMD310AT/CT TECHNICAL DATA. Measurement Accuracy. Measurement Behaviour. MID-specific data. Current (for Class B) General

Environmental Influences. Display. Inputs and Outputs. Electromagnetic Compatibility. Communication Interfaces. Insulation Strenght.

Multi-function (MI, ME, M2, M1) 2 NO (2 SPST-NO) 12 / / 400 3,000 1, / 0.3 / (5 / 5) AgNi

Specifications subject to change without notice Heartbeat of the Smart Grid

SOLUTIONS FOR AN EVOLVING WORLD RFL DSP Powerline Carrier System

REK 510 Current injection device for earth-fault protection of a synchronous machine rotor. User s Manual

[ tima-datasheet-en v11.1 ]

R&D TECHNICAL SPECIFI

INDUSTRIAL+COMMERCIAL ZMG400AR/CR, ZFG400AR/CR TECHNICAL DATA. IEC-specific data. Current. Measurement Accuracy. Measurement Behaviour.

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Solid-state Timer H3DS

Hands On Relay School 2017

High precision measurement system for current and voltage IHC-A/B-RM01/03

APB and SR Product Family General Specifications

M9606. FSK Modem. 5C Communications Inc.

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG400AR/CR. Technical Data

Digital Microwave Radios

Protection components

C series Product brief

Reason RT431. GE Grid Solutions. GPS Precision-Time Clock. Precise Time Synchronization. Compact Design. Hardened for Industry. Time Synchronization

E550 Series 2. Electricity Meters IEC/MID Industrial and Commercial ZMG310AR/CR. Technical Data

CXE880 FIBRE OPTIC NODE

Introduction DIN rail mounted electricity meters

CXE880 FIBRE OPTIC NODE

FTU233. Ripple Control Receiver. Technical Data. Load Management Ripple Control

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Relion 605 series Self-Powered Feeder Protection REJ603 Product Guide

Side view View from below Rear view

Reason RT430/RT434. GE Grid Solutions. GNSS Precision-Time Clocks. Precise Time Synchronization. Flexible Design. Hardened for Industry.

1 INTRODUCTION ORDER CODE / INFORMATION

02/11/2015

CXE880 FIBRE OPTIC NODE

Fixed Series Compensation

T108, GPS/GLONASS/BEIDOU Time Server

POWER LINE CARRIER UCC 2021

INDUSTRIAL+COMMERCIAL ZMD400AR/CR, ZFD400AR/CR TECHNICAL DATA. Frequency. IEC-specific data. Current. Measurement Accuracy.

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

Type CP-S, CP-C & CP-A Switch mode

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Electrical network management. Schneider Electric. PM3200 Technical Datasheet

38 Series - Relay interface modules A

38 Series - Relay interface modules A

Contents. ZT530PCI & PXI Specifications. Arbitrary Waveform Generator. 16-bit, 400 MS/s, 2 Ch

ASHIDA Numerical 3OC + 1EF Protection Relay

SEL Serial Radio Transceiver. The industry-recognized standard for reliable, low-latency wireless communications

E650 Series 3. Electricity Meters IEC/MID Industrial and Commercial ZMD402AT/CT, ZFD402AT/CT. Technical Data

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

83 Series - Modular timers 16 A. Features

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

02/11/2015

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

PD300. Transformer, generator and motor protection Data sheet

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Multi-voltage Multi-function. Wiring diagram (without control signal)

Analog signal converters CC-E I/I

GFT1012 2/4 Channel Precise Slave Generator

CONDUCTED IMMUNITY EMC TEST SYSTEM

SEL-3060 Ethernet Radio Data Sheet

ASHIDA Numerical OC/EF Protection Relay

PTR-1500 AUDIO TONE TELEPROTECTION TERMINAL FEATURES DESCRIPTION

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

Moxa ICF-1280I Series Industrial PROFIBUS-to-Fiber Converter

GPS10RBN-26: 10 MHz, GPS Disciplined, Ultra Low Noise Rubidium Frequency Standard

SOUTHERN AVIONICS COMPANY. SE125 Transmitter. SE125 Transmitter 1-1

Multifunctional counter tico 772/773/774

INTELLIGENT DIGITAL MULTI POWER METER [DIC-MPM]

Application Alpha 20 Measures important electrical parameters in 3 phase 4 Wire and 3 phase 3 Wire Network & replaces the multiple analog panel meters

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Digital Multifunction Instrument - Rish Master 3440

Digital Motor Bus Transfer System M 4272

Improve asset protection and utilization

MSE M A G N E T I C S O U N D E N H A C E R. Passion

exciters (OIRT and JPN Band upon request) Features

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Guidance and Declaration - Electromagnetic Compatibility (EMC) for the Delfi PTS ii Portable Tourniquet System

TCG 02-G FULL FEATURED SATELLITE CLOCK KEY FEATURES SUPPORTS

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Transcription:

Utility Communications Teleprotection Equipment TPT-200 5C Communications Inc. All rights reserved

Teleprotection is designed to transfer protection commands coming, in most cases, from distance protection relay contacts to one remote location through a communication media. TPT-200 gives fast, reliable and secure transmission of protection signals The advance feature Multiple transmission routes that provide fully redundant signaling capabilities If uninterrupted reliability is your primary goal, transmission route redundancy is absolutely essential. Impulse Noise Compression technology. The impulse noise is on high voltage power line. The most serious disturbance can make false command accidentally on receiver and actuate protection relays. The DSP software is developed to check such impulse noise, increase the system security Device addressing prevent unwanted interconnections between two equipments due to routing errors in digital networks and ensure that protection signals are received at the correct destination Redundant power supply with hot standby Various direct fiber optic connections between two TPT-200 devices, fiber optic to a multiplexer or to a PLC terminal Coded tripping mode for 4 independent commands via analog transmission lines. Coded tripping utilizes two tones for the transmission of a protection command. This increases the transmission security anti tone interference. High speed transmission time digital channel <3ms and analog channel <10ms User friendly management system supports the remote access through Ethernet network. Up to 24K sequence-of-events recording Support to record events of the teleprotection commands, system alarm and performance record per hour. Valid transmission media TPT-200 enables transmission of protection signals over all kind of communication media. A mix of analog, digital/optical and Ethernet transmission in any combination at the same time is supported, and multi-channels on various medias are hot backup each other. Fiber (1 or 2) TPT200 G703 SDH/PDH TPT200 2/4w 2 or 4 copper wires UPLC100 UPLC100 TPT-200 offers a complete set of line interfaces to the various communication medias for teleprotection. TPT-200 for digital network TPT-200 could utilize various serial communications port for transmission. G.703.6 - E1(2.048M) / T1 for direct connection to SDH / SONET multiplexer. G.703.1, 64Kbps X.21 /V.35/ RS-232/RS-485 / RS-530 Multiprotocol. The transmission speed can be configured as 16, 32, 64, 128 or 256 kbps. Addressing for high security Devices are identified via addresses when digital communication interfaces are used. This can prevent the unintended connection of two devices following digital network reconfiguration. Use for digital transmission Up to eight commands can be digitally transmitted transparently to the far end, where they can be cross-connected to signal outputs in any required combination. Commands can be transmitted for the protection of two three-phase systems or for one three-phase system with individual phase protection.

The high-voltage power circuit breaker can be operated either in conjunction with selective relays or directly. TPT-200 for fiber optics network A variety of fiber optic applications (single mode, multi mode, short range, long range, bidirectional on one or two fiber) is supported by TPT-200. Direct fiber optic connection between two TPT-200 Support long transmission distance up to 200Km TPT-200 for analog network Noncoded signals / F6 modulation The TPT-200 uses F6 modulation. In this mode only one out of the possible frequencies is transmitted at a time. This allows to use all the available transmission power for one single frequency providing the largest transmission ranges for the protection signal. Coded signals / Extended F6 modulation Two frequencies are sent at the same time to transmit one coded signal. Acceptance of the signal by the The complete set of line interfaces on TPT-200 back planel Fiber optic connection between the TPT-200 and a multiplexer or PLC in the substation A short-distance connection of up to 3 km is supported between: a TPT-200 and PDH/SDH multiplexer a TPT-200 and 5C UPLC-100 The multiplexer could be connected to the TPT-200 via a 5C fiber modem box or integrated fiber board, which converts the optical signal back to an electrical signal for PDH/SDH networks. TPT200 or TPT200 G703 Fiber The optics to G703 converter box SDH/PDH SDH/PDH Communications Room The connectiosn between the TPT-200 and PDH/SDH networks receiver depends on the proper detection of both frequencies at the same time. This protects the system against unwanted interference from single frequencies and increases security. Teleprotection operating mode The TPT-200 is used for fast and reliable transmission of 4 tele-protection commands, which support protection of one or two three-phase system. 2+2 mode (F6): offers the transmission of two three-phase systems. 2 commands are transmitted in the fast permissive trip, and other 2 commands in the direct trip using the coded tripping feature. 3+1 mode (F6): offers 3 fast trips and 1 direct trip using the coded tripping feature. 4 independent commands (Extended F6): offer four binary inputs and every possible combination of inputs is assigned to a pair of protection frequencies. This function is only available with the coded tripping feature.

BroadBand or NarrowBand Mode The TPT-200 supports transmission on both of 4KHz band(0.3~3.4khz) and 2KHz band(0.3~2.0khz). Easy to access and to manage The IP network based Human Machine Interface (HMI) allows easy configuration, operation and monitoring of the system. In addition, integrated LCD and LEDs on front panel display the system status. Our Windows-based HMI software, MTPT-200, is easily installed on your PC. Self-explaining menus of MTPT-200 are used friendly for configuration, operation and maintenance. All parameters relating to system operation are stored in nonvolatile memory. All of local or remote TPT-200s can be connected Internet Remote access to your system through the Internet by a single Management interface. In such a network, all TPT-200s are accessible with a unique device address. A connection to the equipment, either local or remote, is always secured by means of a user log-in with a two-level password, identification (admin or view access rights). Technical data General features Operating modes Number of commands Blocking, Unblocking, Permissive Transfer Tripping(PTT), Direct Transfer Tripping(DTT) Up to 4 independent commands for analog communication channels Up to 8 independent commands for digital communication channels Power Supply 24 VDC (Tolerance ±20%) range 18 to 35 VDC 48VDC (Tolerance ±20%) range 36 to 70 VDC 125/250 VDC Wide Range 100 370 VDC 110/220 VAC Wide Range 85 265 VAC 47Hz~63Hz Alarm outputs Mechanical relay contacts, max. 280 VDC/5A Event logging 24K time-stamped command/alarm events, command counters; stored in non-volatile memory Clock synchronizing IRIG-B port Management facility By means of standard PC via the interface 115.2 kbps RS 232, or SNMP on Ethernet interface 10/100 BaseT Front panel Integrated LCD display panel Command input Nominal input voltage 24, 48, 125, 250V DC ( 20 % to +15 %) Threshold value 50~70 % of the nominal input voltage

Method of tripping Contact and battery, Polarity independence Yes Pulse suppression 0.125 ms to 50 ms, (programmable in 0.125-ms steps) Command output Type of outputs Solid state relays and mechanical relay contacts Switching voltage max. 280 VDC Switched current max. 1 A (3A/10ms) for solid state max. 5 A (20A peak) for mechanical relay Insulation dielectric strength 2.5 kvrms Line Interface (Digital) Digital 2M G.703.6 - E1(2.048M) / T1 for direct connection to SDH / SONET multiplexer, sym. 120 Ω or asym. 75 Ω Transmission time: < 3 ms Digital low speed G.703.1 64Kbps or X.21 / X.24; RS-422 / RS-530 / RS-449 Multiprotocol (16, 32, 64, 128, 256 kbps) Transmission time:<5ms Fiber Optic Utilizing standard SFPs. different SFP modules can be selected. Bidirectional one fiber is option. 850 nmled Multimode 1300 nm LED Multimode 1300 nm LED Singlemode 1300 nm LASER Singlemode 1550 nm LASER Singlemode Standard: IEEE C37.94 Transmission time: < 3 ms Security < 10-8 Dependability < 10-4 at BER of 10-6 Line Interface (Analog) Modulation type Extended F6 modulation (frequency shift keying or coded tripping). Trip frequencies 0.5 to 1.95 khz Guard frequencies 2.1 to 3.9 khz Transmitter Impedance 600 Ω, Level max. +11 dbm Receiver Impedance 600 Ω, Level range 50 db to +3 db Normal transmission time Blocking <10ms Permissive tripping <11ms Direct tripping <12ms Security Blocking < 1E-04 Permissive tripping < 1E-06 Direct tripping < 1E-09 Dependability, condition: Blocking 6 db/11 ms, <1E-3

SNR/Tac Permissive tripping 3 db/20 ms, <1E-4 Direct tripping 0 db/40 ms, <1E-4 Electromagnetic compatibility (EMC) Insulation withstand voltage VF input/output 500 Vrms Power supply 2.5 kvrms Command input/output 2.5 kvrms Alarm outputs 2.5 kvrms Digital input/output(g703, V11/X.21) 500 Vrms Impulse withstand level VF input/output 1 kv (1.2/50 μs) Digital input/output 1 kv Power supply 5 kv Command input/output 5 kv Alarm outputs 5 kv Damped oscillatory waves Common mode (line-to-line) 2.5 kv Differential mode(line-to-ground) 2.5 kv Surge Common mode (line-to-line) 4 kv Differential mode(line-to-ground) 2 kv Fast transient bursts Power supply 4KV Data line 2KV Electrostatic discharge 8 kv (contact discharge) 15KV(air discharge) Electromagnetic fields(rf 10 V/m (80 MHz 2 GHz) fields) Conducted disturbances 10 Vrms (150 khz 80 MHz) Ambient conditions Operation -5 C to + 55 C Storage and transport 40 C to + 70 C Relative humidity 5 to 95 % Mechanical conditions Degree of protection IP 20 Vibration 5 9 Hz: 1.5 mm amplitude 9 200 Hz: 0.5 g acceleration International standards teleprotection equipment IEC 60834-1 second edition 1999-10 Power supply and electromagnetic compatibility IEC 60870-2-1 Environmental conditions IEC 60870-2-2 Mechanical design Height/Width/Depth 132mm/485mm/280mm (3U/19"inch) Weight approx. 5 kg