EISCAT_3D: Preparation for Production EISCAT3D_PfP

Similar documents
EISCAT Scientific Association Technical Specification and Requirements for Antenna Unit V 2.0

(53) EISCAT Scientific Association System and Subsystem Design Description EISCAT3D_PfP

MAKING TRANSIENT ANTENNA MEASUREMENTS

Model 855 RF / Microwave Signal Generator

Scalable Ionospheric Analyser SIA 24/6

Antenna and Analog Beamformer

An Accurate phase calibration Technique for digital beamforming in the multi-transceiver TIGER-3 HF radar system

Design Implementation Description for the Digital Frequency Oscillator

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT, 250KSPS ADC

FMSN3902 DATA SHEET. USB Frequency Synthesizer PLL (Phase Locked Loop), Operating From 5 GHz to 10 GHz With SMA Output. Features: Applications:

Scalable Front-End Digital Signal Processing for a Phased Array Radar Demonstrator. International Radar Symposium 2012 Warsaw, 24 May 2012

STUDIO TO TRANSMITTER LINKING SYSTEM

DR-TRC105-EV Evaluation Kit. User s Guide

PN9000 PULSED CARRIER MEASUREMENTS

Using an Arbitrary Waveform Generator for Threat Generation

RS3400W/04 77 GHz Radar Sensor

Pulsed VNA Measurements:

Integrated receivers for mid-band SKA. Suzy Jackson Engineer, Australia Telescope National Facility

ThinkRF R5500. Real-Time Spectrum Analyzer. 9 khz to 8 GHz / 18 GHz / 27 GHz. Product Brochure and Technical Datasheet. Featuring

SPECIAL SPECIFICATION 6574 Low Power Wireless Modem

MWA Antenna Description as Supplied by Reeve

A DSP IMPLEMENTED DIGITAL FM MULTIPLEXING SYSTEM

4GHz / 6GHz Radiation Measurement System

2-PAD: An Introduction. The 2-PAD Team

SAMPULSE50GHz and SAMPULSE70GHzANT PULSER/SAMPLER DEMO BOARD

TRC EV DR TRC EV DR TRC EV

GFT Channel Digital Delay Generator

GFT1504 4/8/10 channel Delay Generator

Faculty of Information Engineering & Technology. The Communications Department. Course: Advanced Communication Lab [COMM 1005] Lab 6.

The EISCAT Heating Facility

EMC TEST REPORT For MPP SOLAR INC Inverter/ Charger Model Number : PIP 4048HS

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

EISCAT_3D Digital Beam-Forming and Multi-Beaming

Specification for Radiated susceptibility Test

Calibrating the NI 5653 requires you to install one of the following packages on the calibration system. NI-RFSA 2.4 or later NI-RFSG 1.

Integrated receivers for mid-band SKA. Suzy Jackson Engineer, Australia Telescope National Facility

SIGNAL GENERATORS. MG3633A 10 khz to 2700 MHz SYNTHESIZED SIGNAL GENERATOR GPIB

Appendix B. Design Implementation Description For The Digital Frequency Demodulator

ThinkRF R5500. Real-Time Spectrum Analyzer. 9 khz to 8 GHz / 18 GHz / 27 GHz. Product Brochure and Technical Datasheet. Featuring

RADAR Simplified. Wideband & Ultra-wideband radar solutions for HF, VHF, UHF & SHF bands

FM DISTRIBUTION FOR MOTORWAYS AND TUNNELS

UHF Phased Array Ground Stations for Cubesat Applications

Model 745 Series. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since Model 845-HP Datasheet BNC

ETSI Standards and the Measurement of RF Conducted Output Power of Wi-Fi ac Signals

Signal Forge 2500M Frequency Expansion Module. 1.5 GHz to 2.6 GHz. User Manual

PHY PMA electrical specs baseline proposal for 803.an

AWG801 8 GSPS 11-bit Arbitrary Waveform Generator

Model 1152-ALN Phase Locked Oscillator

DFS Test Report : IWAVEPORT WLM200NX : 08B005S

AV3672 Series Vector Network Analyzer

Comprehensive Ultrasound Research Platform

RF Generators. Requirements:

RF and Microwave Test and Design Roadshow 5 Locations across Australia and New Zealand

Signal Forge 1800M Frequency Expansion Module. 1.0 GHz to 1.8 GHz. User Manual

AUTOMOTIVE ETHERNET CONSORTIUM

Keysight Technologies 81180B Arbitrary Waveform Generator

Tunable Wideband & Ultra-Wideband Multi- Antenna Transceivers with Integrated Recording, Playback & Processing

What s Behind 5G Wireless Communications?

Amplifier Characterization in the millimeter wave range. Tera Hertz : New opportunities for industry 3-5 February 2015

Platform Migration 8510 to PNA. Graham Payne Application Engineer Agilent Technologies

SECTION WIRELESS CLOCK/TONE GENERATOR SYSTEM

Ultra Wideband Indoor Radio Channel Measurements

Advanced Waveform Generator For Integrated Phased Array Testing

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

Advances in Antenna Measurement Instrumentation and Systems

FREQUENCY SYNTHESIZERS, SIGNAL GENERATORS

Addressing the Challenges of Wideband Radar Signal Generation and Analysis. Marco Vivarelli Digital Sales Specialist

Focal Plane Array Beamformer for the Expanded GMRT: Initial

Bandwidth Radar Receivers

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

Technician Licensing Class. Antennas

Agilent E8267C PSG Vector Signal Generator

ST600 TRANSMITTER OPERATING INSTRUCTIONS

I Only to be used by a licensed radio amateur I

From Antenna to Bits:

Understanding RF and Microwave Analysis Basics

1 UAT Test Procedure and Report

QuickSyn Frequency Synthesizers

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT /14 BIT 40 TO 105 MSPS ADC

Agilent 8360B/8360L Series Synthesized Swept Signal/CW Generators 10 MHz to 110 GHz

PXIe Contents. Required Software CALIBRATION PROCEDURE

FAQs on AESAs and Highly-Integrated Silicon ICs page 1

DELTA MODULATION. PREPARATION principle of operation slope overload and granularity...124

Exercise 1: RF Stage, Mixer, and IF Filter

White Paper. Gallium Nitride (GaN) Enabled C-Band T/R Modules

Terahertz Wave Spectroscopy and Analysis Platform. Full Coverage of Applications From R&D to Industrial Testing

Final Report (Group 15-22)

Design of Controlled RF Switch for Beam Steering Antenna Array

Advanced Waveform Generator For Integrated Phased Array Testing

Agilent. E8267C PSG Vector Signal Generator E8257C PSG Analog Signal Generator E8247C PSG CW Signal Generator

PERFORMANCE CONSIDERATIONS FOR PULSED ANTENNA MEASUREMENTS

MOBILE RAPID-SCANNING X-BAND POLARIMETRIC (RaXPol) DOPPLER RADAR SYSTEM Andrew L. Pazmany 1 * and Howard B. Bluestein 2

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

Developing a Generic Software-Defined Radar Transmitter using GNU Radio

RF Measurements You Didn't Know Your Oscilloscope Could Make

Noise by the Numbers

The Sampling Theorem:

SYSTEM ARCHITECTURE OF RADAR NETWORK FOR MONITORING OF HAZARDOUD WEATHER

TS9050/60. microgen. electronics TM FM Modulation and Spectrum Analyser

Overview of the MSA 12/30/10

Transcription:

EISCAT_3D: Preparation for Production EISCAT3D_PfP Deliverable D2.2 Test plan for the Test Sub-array Work Package 2 Coordination and Outreach Leading Beneficiary: EISCAT Scientific Association Authors Mr. Harri Hellgren, Mr. Robert Juhlin, Mr. Lennart Lövqvist, Mr. Peter Bergqvist and Dr. Sathyaveer Prasad Reviewed by: Dr. Craig Heinselman and Dr. Assar Westman Deliverable type: Dissemination level: REPORT PUBLIC Deliverable due date: 28.02.2017 Actual Date of Submission: --.03.2017

Table of Contents Abstract...5 Introduction...5 1 Instruments...7 2 Test programs...7 2.1 Signal measurements...7 2.1.1 Signal level...7 2.1.2 Noise level...7 2.1.3 Amplitude and phase difference...7 2.2 Waveform generation...7 2.2.1 Sine wave...7 2.2.2 Frequency Sweep...8 2.2.3 Sinc and Chirp...8 2.2.4 Wideband noise...8 2.3 Complete test sets...8 3 First Stage Receiver Unit...8 3.1 Mechanics and connectors...8 3.1.1 Mechanical connections...8 3.1.2 Electrical connections...8 3.2 Front-End...8 3.2.1 Input...9 3.2.2 Noise I...9 3.2.3 Signal level...9 3.2.4 Linearity...9 3.2.5 Crosstalk...10 3.3 Control commands...10 3.4 Beamforming...10

D2.2 Test plan for the Test Sub-array 3 (14) 4 Pulse and Steering Control Unit...10 4.1 Mechanics and connectors...10 4.1.1 Mechanical connections...10 4.1.2 Electrical connections...10 4.2 Analog signal...11 4.2.1 Signal level...11 4.2.2 Crosstalk...11 4.2.3 Frequency response...11 4.2.4 Linearity...11 4.2.5 Noise...12 5 Antenna Unit...12 5.1 Mechanical...12 5.1.1 Connections...12 5.1.2 Structure...12 5.1.3 Antenna elements...12 5.2 Electrical...12 5.2.1 Return loss...12 6 Transmit Unit...12 7 Time and Frequency Unit...12 7.1 10 MHz reference out put...13 7.1.1 Output amplitude...13 7.1.2 Frequency Accuracy...13 7.1.3 Harmonics...13 7.1.4 Phase Noise...13 7.2 1PPS out...13 7.2.1 Output amplitude...13 7.2.2 Frequency Accuracy...13 7.3 Synchronisation test...13

D2.2 Test plan for the Test Sub-array 4 (14) 8 System performance tests...13 8.1 Receiver tests...13 8.2 Transmitter tests...13 8.3 Radar test...14

D2.2 Test plan for the Test Sub-array 5 (14) Abstract This report discusses the test plan for each of the subsystems and for the overall sub-array, which is planned to be constructed at Ramfjordmoen site in Norway. Further, this report will serve as guideline for the testing of test sub-array and also, to assess the interoperability of the various subsystems. Introduction The EISCAT_3D system is in implementation phase and it is initiated through EISCAT_3D preparation for production (EISCAT3D_PfP) project. EISCAT3D_PfP project will enable smooth transition from preparatory phase to implementation by moving from individual prototype subsystems to manufacture ready designs for immediate implementation in an industrial production environment. Further, this project also focusses on the operation of these subsystems as a single system by assessing the interoperability of the various subsystems. The above challenges will be addressed (via industrial outreach) by implementing and testing a demonstrator sub -array, at EISCAT's Ramfjordmoen site, near Tromsø in Norway, by using subsystems that are as close as possible to a final configuration. This report discusses the test plan for each of the sub-systems and also, for the overall sub-array. Thus, enabling the testing of various subsystems and overall sub-array by the end of this project. Further, this report also discusses the test plan for sub-system manager interface to assess the interoperability of various subsystems. During EISCAT3D_PfP project, an EISCAT_3D test sub-array system will be produced and tested at EISCAT's Ramfjordmoen facility in Norway. This hardware will be similar to the final sub-array configuration that will be deployed at the EISCAT_3D core site in the future. The total size of this test sub-array will be approximately 7m in diameter with an additional buffer for safety reasons. This test sub-array will transmit a maximum peak output power of 91 kw (500W per polarisation per antenna) in the frequency band around 233 MHz and with a maximum bandwidth of 5 MHz. Currently, Ramfjordmoen facility has transmit license in the band of 230.016-236.544 MHz with a peak transmit power of 2 MW. The receiver frequency band is 218-248 MHz. A top-level block diagram of the different procurement objects/subsystems in the test sub-array is shown in Figure 1. The test sub-array system consists of following sub-systems: Antenna Unit (AU), made up of 91 inverted v-shaped crossed dipole antenna elements together with its meshed ground plane, mounted approximately 3.0m above the ground level. This unit also includes array structure and other supporting structure such as the mounting poles.

D2.2 Test plan for the Test Sub-array 6 (14) Figure 1: A top level block diagram of the different subsystems in the EISCAT_3D test sub-array. Transmit Unit (TU) consists of a power amplifier, transmit/receive switch and a power supply unit. This unit will be supplied as in-kind contribution from National Institute of Polar Research (NIPR), Japan. First Stage Receiver Unit (FSRU) is made up of low noise amplifier (LNA), anti-aliasing filter, analog to digital converters (ADC) and a digital beamfo rmer along with a control circuitry and application programming interface (API). Pulse and Steering Control Unit (PSCU) consists of a radar controller unit, an exciter, and an interface to the other sub-systems. Status and Control Unit is a standard Linux server with number of 10 GbE and 1 GbE Ethernet connections. Time and Frequency Unit consists of a Time and Frequency standard and White Rabbit (WR) master and network node units.

D2.2 Test plan for the Test Sub-array 7 (14) 1 Instruments Following instruments are needed for the tests: Antenna analyser Vector Network Analyzer (VNA) Signal generator (SG) Frequency counter Spectrum analyser 2 Test programs The test programs are made to record as well as analyse FSRU output data and further, control signal generator. Programs can be written during the development phase of FSRU and PSCU by using languages such as LabVIEW, MATLAB or Python. Test programs include at least: 2.1 Signal measurements During FSRU and PSCU development phase the test programs which analyse the following test parameters are developed: 2.1.1 Signal level Calculates signal level in given frequency. 2.1.2 Noise level Calculates noise level and system temperature using given noise bandwidth and frequency range. 2.1.3 Amplitude and phase difference Measures amplitude and phase difference between two channels. Beamforming test program is used to test full band delay. Wide band signal (Sinc or noise) is used to generate 30 MHz signal in the input of FSRU. Having one channel as a reference and the other as a measurement we can check the variation in signal delay. 2.2 Waveform generation Generate digital signals in to a file. Files are used as waveforms for PSCU unit and can be downloaded to the signal generator. All needed waveforms are included to LabVIEW and can be used directly from there. 2.2.1 Sine wave Single sine wave with adjustable frequency and amplitude is used for testing.

D2.2 Test plan for the Test Sub-array 8 (14) 2.2.2 Frequency Sweep A program to produce frequency sweep with adjustable amplitude, sweep time and start/stop frequency. 2.2.3 Sinc and Chirp One waveform which includes many frequencies. Adjustable frequency range, amplitude and duration. 2.2.4 Wideband noise Generate noise signal with adjustable bandwidth and amplitude. 2.3 Complete test sets Following test programs for more complicated test tasks are made. Frequency Response Crosstalk Linearity 3 First Stage Receiver Unit 3.1 Mechanics and connectors Mechanical connections are verified first in the supplier documentation and then visually during the Factory Acceptance Tests. 3.1.1 Mechanical connections Verify that unit can be rack mounted. 3.1.2 Electrical connections Verify that: 3.2 Front-End 230V 1 phase connections with standard plug in RF in connectors MMCX or similar coaxial connector Ethernet connectors RJ-45 Analogue properties of the Front-End is measured using VNA and signal generator. FSRU will be in test mode so that raw signal from ADC is feed directly to data out and measured using PC.

D2.2 Test plan for the Test Sub-array 9 (14) 3.2.1 Input Measure return loss of the input using VNA. Verify that requirement is met for full band and each 182 input channels. FSRU VNA 3.2.2 Noise I Connect 50-Ohm termination to input and record raw data from all channels to hard disc. Verify using program that requirement of maximum noise level is met for all channels. 3.2.3 Signal level Connect signal generator having CW 233 MHz and -30 dbm to input and record raw data from all channels to hard disc. Using test program verify that all channels receive signal. 3.2.4 Linearity Connect signal analyzer to laptop and run non-linearity test program for linearity checks.

D2.2 Test plan for the Test Sub-array 10 (14) 3.2.5 Crosstalk Send signal to one channel and measure from next and using signal level program check that level doesn t exceed -20 db. 3.3 Control commands Connect FSRU to LAN network and start commands test program. Check that following tasks can be made: Start acquiring data Stop acquiring data Set delays Set filter taps Set decimation 3.4 Beamforming Connect signal analyzer as shown in figure below. One channel is used as a reference and other for measurement. Run test program and verify that delay variation in all channels is correct. 4 Pulse and Steering Control Unit 4.1 Mechanics and connectors Mechanical connections are verified first in the supplier documentation and then visually during the Factory Acceptance Tests. 4.1.1 Mechanical connections Verify that unit can be rack mounted. 4.1.2 Electrical connections Verify that:

D2.2 Test plan for the Test Sub-array 11 (14) 230V 1 phase connections with standard plug in RF out connectors are MMCX or similar coaxial connector GPIO out connectors are MMCX or similar coaxial connector Ethernet connectors are RJ-45 4.2 Analog signal Analogue properties of the PSCU output are measured using test programs and signal analyser. Test Program is used to generate waveforms from PSCU and these waveforms are sent to signal analyzer. Measurement setup is shown in figure below: 4.2.1 Signal level Set signal to 233 MHz full scale and verify that RF signal out is 233 MHz and 0 dbm. 4.2.2 Crosstalk Send signal to one channel and measure from next and using signal analyzer that level doesn t exceed -20 db. 4.2.3 Frequency response Run frequency response test program and verify that response is correct. Repeat for all channels. 4.2.4 Linearity Using linearity test program generate amplitude sweeps with different frequencies in the transmitting band. Measure and record signal using signal analyser verify that nonlinearity does not exceed requirement. Repeat for all channels.

D2.2 Test plan for the Test Sub-array 12 (14) 4.2.5 Noise Set PSCU to send empty waveform and verify that output signal is less than -50 dbm. Repeat for all channels. 5 Antenna Unit 5.1 Mechanical 5.1.1 Connections Each antenna has two polarizations, check that each polarization is properly connected to a RF-cable. Check also that an N-connector is mounted on the opposite end of each cable. 5.1.2 Structure 1. Measure the height of the structure and check that the minimum height is 3.0m. 2. Check that the antennas are properly attached to the ground structure. 3. Measure that parts are electrically connected 4. Check distance between antennas 5. Check all directions for proper antenna alignment 5.1.3 Antenna elements Check visually that each antenna element is without any mechanical defects and have a 90-degree angle between each other. 5.2 Electrical 5.2.1 Return loss Measure full band return loss for each antenna and polarization using the VNA. Check that return loss is below the requirements for the transmit- and receive-bands. 6 Transmit Unit Transmit Units are tested by NIPR before delivery and a basic functionality test will be performed at the site before integrating it with other sub-systems. 7 Time and Frequency Unit These measurements are repeated to all equipment in the network: White Rabbit (WR) Master WR Slave

D2.2 Test plan for the Test Sub-array 13 (14) 7.1 10 MHz reference out put 7.1.1 Output amplitude Check that output is at least 0 dbm. 7.1.2 Frequency Accuracy Measure using frequency counter that frequency accuracy is better than 10-10. 7.1.3 Harmonics Check that all harmonics are below -40 db. 7.1.4 Phase Noise Measure that phase noise is better than -100 dbc/hz @1 khz out of centre frequency. 7.2 1PPS out 7.2.1 Output amplitude Check that output is at least 0 dbm. 7.2.2 Frequency Accuracy Measure using frequency counter that frequency error to site reference is better than 10-10. 7.3 Synchronisation test Using oscilloscope and histogram display check that 1 sigma time variation is less than 100 ps between the reference clock and any WR slave device in the network. 8 System performance tests System test are performed using known source in the sky and reflector located either in a mast, drone or balloon. 8.1 Receiver tests Using known radio wave source, like sun, receiver beamforming performance can be evaluated. Beam is scanned over the sun and from measured amplitude data the size of the beam can be calculated. 8.2 Transmitter tests Reference receiver located in mast, drone or balloon is used to measure transmitter signals from array. Transmit beam is scanned over the test receiver antenna and signal

D2.2 Test plan for the Test Sub-array 14 (14) strength is measured. Transmit beam size can be calculated from pointing directions and signal amplitude. 8.3 Radar test Know radio wave reflector is located to the drone, balloon or mast. Radar transmitter beam and receiver beams are directed to the reflector.