EBDSM-PRM Product Guide

Similar documents
EBDSPIR-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

EBDHS-MB-AT-DD. RF ceiling PIR presence detector DALI / DSI dimming. Product Guide. Overview. Features

RF ceiling microwave presence detector DALI / DSI

AT-SL-DDR & AT-SL-DDR-SA

AT-SL-DDR & AT-SL-DDR-SA

AT-SL-ADR & AT-SL-ADR/SA

AR-DN-RS232. An-10 / Rapid RS232 Interface. Product Guide. Overview. Features

High/Low Bay Passive Infrared Occupancy Sensor

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Human Centric Lighting System

Installing the FSP-211 Sensor in Light Fixture

1: White buttons Used by the user on a daily basis. 2: Grey buttons Used only upon first startup.

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

v3 360 Passive Infrared Line Voltage Occupancy Sensor

LCC1653, LCC1656, LRI1653 Datasheet ActiLume DALI System

ETC Installation Guide

ActiLume G2 Indus Sensor H513

with Light Level, Isolated Relay and Manual On features

3000W multi Pir light controller

Operating instructions II / 2004

PARTS INCLUDED TOOLS & PARTS NEEDED Do not mount on vibrating surfaces. appro to 2.5 meters 12M

Installation Instructions

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

3000W MULTI PIR LIGHT CONTROLLER

Eco-$mart, Inc. TOLL FREE:(888) FAX:(941)

Fixture Built-in Sensor Daylight Harvest Version

TekLink TL100 with Passive Infrared Sensing System Overview

DESCRIPTION & OPERATION: PIR OCCUPANCY SENSOR MSWSFSP221B-D FEATURES:

Data sheet. Function description. Benefits

LOAD AWG Solid CU Wire Only LINE NEUT FSP-211. High/Low PIR Occupancy Sensor 230 VAC, 50 Hz 1200W max ballast 5E4

ActiLume 1-10V. OEM application guide

Dual Technology Wall Mount Occupancy Sensor

2 Pendant Adjustment. Pendant Slider Plate. 3/4 (19mm) IP, (29mm) O.D. Knockouts. 1/2 (13mm) IP, (22mm) O.D. Knockout

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

EasyAir Office sensor advanced grouping SNS200

SELECTABLE MODE HIGH/LOW/OFF PIR FIXTURE INTEGRATED INDOOR/OUTDOOR MOTION/PHOTO SENSOR

USERS GUIDE EAGLE SMR MOTION SENSOR

Installation Instructions

Sensors. Datasheet. EasyAir SNS200

Wireless Occupancy Sensor User Guide

Sensors. Datasheet. EasyAir SNS200

Dialight Daylight Harvesting Sensor User Guide

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

Installation and Operating Instructions. Power IT Power Factor Controller RVC

OPERATING INSTRUCTIONS ARE ON PAGE 5. SECTION 2 Technical Data Transmitter Unit. RVHT 2 MULTI-FIT Programmable R/F Thermostat-Pair SECTION 1

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE FOR FLEXIBLE MOUNTING

EasyAir Office sensor advanced grouping SNS200

Light Control guide for Soundlight Comfort Ceiling OccuSwitch DALI Control Guide

CX-100. Installation Instructions. PIR Occupancy Sensor SPECIFICATIONS

Infrared Wall Mount Occupancy Sensor

User manual. KNX MultiController DALI. Article number: 5410x / 5411x. function Technology AS

Dual Technology Wall Mount Occupancy Sensor

RF Wireless Version On/off Control

RPT LEDCF 4000K LEDCF LOW-PROFILE LED CANOPY LUMINAIRE PART NUMBER BUILDER

HIGH/LOW/OFF PIR OUTDOOR PHOTO/MOTION SENSOR IN IP66 ENCLOSURE WITH BLUETOOTH

LP20RF & DIGISTAT+RF. Installation & User Guide PRINT. Radio frequency controlled room thermostat with dual channel programmer. Part number RF562DR

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

Installation Instructions SKU# , Rated Voltage V~ 50Hz

NRT 105: Electronic fan-coil controller, equiflex

Outside Temperature Sensors

Indoor Contact Input Photosensor

ODSOD-ID. D u a l - R e l ay Decora Wall Sw i t c h Occupancy Sensor

User Manual. KNX MultiLight Dali. Article number: function Technology AS. Picture: KNX MultiLight products

MOTION DETECTOR WITH CONSTANT LIGHT CONTROL DM KNT 003

ZoneLite setup remote handset. Daylight Linking & Daylight Dependency control

High Bay Occupancy Sensor for Use with Electronic Ballast HID Luminaires

Viconics VT76x7 Series Rooftop Unit Controllers Engineering Guide Specification

ETC Installation Guide

ORDERING CODE Z-WAVE FREQUENCY COUNTRY/REGION

luxcontrol lighting control system DALI sensors basicdim RCL DBC Control module for combination with ambient light sensor, switch and presence sensor

O ccupancy and Light Level Sensor L ow Vo l tage Ceiling Fixture Mount

Sendai Office , Ichiban-cho, Aoba-ku, Sendai, Miyagi pref TEL FAX

LLC1681, LRI1655 Datasheet ActiLume Wireless 1-10V system

LEDCF LOW-PROFILE LED CANOPY LUMINAIRE

Technical Application Guide

FIXTURE INTEGRATED DAYLIGHT DIMMING PHOTOSENSOR

BAPI-Stat 4 X-Combo, Room %RH and Temp. Sensor BA/BS4XC Installation & Operating Instructions

INSTRUCTION MANUAL. Power Factor Controller - 12 steps Model A12 NOKIAN CAPACITORS. Power Factor Controller A12

CM80 Series Vari-Angle IR Illuminator

STORING MESSAGES Note: If [MEMORY] (F5) is unavailable in the function key guide, press [MORE] (F2). An alternate key guide will appear.

High Intensity LED Stroboscope Digital Tachometer DT-361/365. Instruction manual. Be sure to read before use.

MANUFACTURER MODEL NUMBER LUMENS COLOR TEMPERATURE OPTIONS 3100LM 4500LM 5800LM

RSMFX-2R MULTIFUNCTIONAL

Litex Elite. Industrial. Up to 170Llm/cW. 6 Litex Elite IK10

EasyAir office sensor standalone SNS100

Applications. HBT02 Transceiver Node. Features. Note: This datasheet is intended for information related to the hardware only.

EIB/KNX Switch Actuators. User manual

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

Installation Instructions

MCU Software Configuration and System Calibration

Light Management Systems for Indoor Use MULTISENSORS

Data Flow 4.{1,2}, 3.2

Communicative heating controller

SeriesTWO RGB Fluorescent Fixtures. Installation and Instruction Manual

Sense Command Control. Third Eye. Energy Saving Sensors Save Energy Today for a Better Tomorrow

LK Wireless Room Control Cq

This document is intended for Lighting Control Systems professionals

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

18W Nightsensor Bulkhead

Transcription:

EBDSM-PRM Product Guide Ceiling PIR presence/absence detector Overview The EBDSM-PRM PIR (passive infrared) presence detector provides automatic control of lighting loads with optional manual control. The output channel comprises a mains voltage relay capable of simple on/off switching. Functioning as a presence detector, the unit can turn lights on when a room is occupied and off when the room is empty. Optional settings allow lights to be turned off in response to ambient daylight. All functionality is fully programmable using an IR handset. Features PIR Sensor Detects movement within the unit s detection range, allowing load control in response to changes in occupancy. Front features IR Receiver Receives control and programming commands from an IR (infrared) handset. Light Level Sensor Measures the overall light level in the detection area Sensor Lens! " " # $ % & ' ( ( ( PIR Sensor IR Receiver Light Level Sensor Status LEDs Power Input & Switched Output Connector Used to connect mains power to the unit and to connect a switched load. Back features Power Input & Switched Output connections Switch Input Connector Power Input & Switched Output Connector Status LEDs The LED flashes Red to indicate the following: Switch Input Connector Two input terminals can be used to manually override the lights on or off.

Detection diagram Area of high sensitivity Area of lower sensitivity Sensor functionality Detection Mode The Detection Mode can be set to behave in Presence or Absence mode: Presence When movement is detected the load will automatically turn on. When the area is no longer occupied the load will automatically switch off after an adjustable time period. Absence The load is manually switched on. When the area is no longer occupied the load will automatically switch off after the adjustable time period has elapsed. In either case, sensitivity to movement of the PIR sensor can be adjusted using the Sensitivity parameter. ) * +, -,. / 0 0 1 0 2 1 3 0 4 2 21 3 5 26 4 7 4 3 0 1 21 8 1 29 : 2 ; < 3. 3 26 4 = / >?, 4 0 2 @ A B C 6 1 D 6 C 1 > > E> / 0 6 < 4 F C 6 4 3 G. 8 4 G 4 3 2 1 0 F 4 2 4 D 2 4 F H Switch Level On/Off Occupancy detection can be made dependant on the ambient light level using the Lux On Level and Lux Off Level parameters. 2

Installation Choosing a Suitable Location The EBDSM-PRM is designed to be ceiling mounted and must satisfy the following criteria: Avoid positioning the unit where direct sunlight may enter the sensor element. Do not site the sensor within 1m of any lighting, forced air heating or ventilation. Do not fix the sensor to an unstable or vibrating surface. I J K L M N L O L P L N P Q R M To use absence detection a retractive (momentary) switch must be connected between the 2 terminals on the diagram. Note that this will be switching mains voltage. The unit ships with presence detection as default. To change to absence detection, press and release the external switch 5 times within the first minute of power up. The LED will turn on solid for 30 seconds to indicate absence mode has been selected. To change back to presence detection, repeat the above procedure the LED will flash for 30 seconds to indicate presence mode has been selected. Note: the above adjustments can also be made using the UHS5 or UNLCDHS handsets. See Programming sections. Power-up test procedure When power is applied to the unit, the load will turn on immediately. Set the timeout to 10 seconds, vacate the room or remain very still and wait for the load to switch off. Check that the load switches on when movement is detected. The unit is now ready for programming. 3

Installation Choosing a suitable location The EBDSM-PRM is designed to be ceiling mounted and must satisfy the following criteria: The sensor should be sited so that the occupants of the room fall inside the detection pattern overleaf, at a recommended height of 2.8m on the ceiling. Note that the lower the sensor is installed the smaller the detection range will be, subject to the parameters shown on the diagram. Avoid positioning the sensor where direct sunlight may enter the sensor element. Do not site the sensor within 1m of any lighting, forced air heating or ventilation. Do not fix the sensor to an unstable or vibrating surface. Components Rear entry 2a 3 Gasket Œ Ž Œ Wire cables into the terminals Mounting plate Pass cable through Gasket and Mounting plate 4 Sensor Head 2b Side entry Pass cable through either of the 2 side entry points in the Mounting Plate Conduit Push the Sensor Head onto the Mounting Plate and align clips with slots on Sensor Head 1 5 Screw the Mounting plate and optional Gasket to the ceiling via the 4 mounting holes. Œ Ž Œ š Ž œ Œ š ž Ÿ œ Œ š Ž œ Œš Œ š Ÿ œ ª«œ Œ Knock-outs on Sensor Head for clearing side entry of conduit and / or cables Use a flat bladed screwdriver to unclip the Mounting Plate from the Sensor Head The UNLCDHS has the ability to read back the settings stored in a device. To read back individual parameters 4 Navigate to the parameter and press the R (Read) button whilst pointing at the device. The handset will click when the parameter has been read back, the device will flash its LED, and the value will be shown against the parameter in the menu. To read back all of the parameters in a menu Readback function x y z { } ~ ƒ ˆ Š S T U V W Press and hold the R (Read) button for more than 1 second. The handset will click every time a parameter is received The device will show multiple flashes of its LED All of the values will be shown against the parameters in the menu. The individual parameters may be edited and then saved as a Macro. X Y Z [ Z \ Z ] ^ _ ^ \ ` a b c Z a d ^ ^ e ] f a a ^ g d ^ h Z i a ^ j Y Z h j ] ] i e f h Z _f j e ^ \ \ j \ k _c ^ ] f a a f e l m Z n i ^ ` a b f a \ ^ [ n Z h ^ g d o g Z a c ^ a p q c ^ e \ ^ Z g f e l d Z h r k _c ^ s c Z e e ^ n t \ ^ n Z o ` u c ^ \ ^ Yf ^ g b u f n n _ ^ ] [ j \ Z \ f n o d ^ a u f _ h c ^ g j Y Yk Z e g u f n n \ ^ _ i \ e _ j f _ v a e j \ ] Z n a _ Z _ ^ w a ^ h j e g a Z Y _ ^ \ _c ^ \ ^ Z g d Z h r c Z a d ^ ^ e h j ] [ n ^ _ ^ g p

Basic programming The functionality of the EBDSM-PRM is controlled by a number of parameters which can be changed or programmed by any of the following devices: UHS5 Infrared Handset. See below for programmable functions. UNLCDHS Infrared Handset (with LCD). See user guide for full programming details. For most basic programming operations the UHS5 handset can be used and the following procedures are based on using this device. Point the handset at the Sensor and send the required programming commands to the unit as shown below. Valid commands will be indicated by a red LED flash. See page 1 for details of other LED responses. ß à á â ã à á ä â å æ ç è é á ê à è ë à è á ä â ì í î ï ð ä ê é ä ñ å â è à á ë ä à ð è ò â ó à ð ñ å â è à á ñ ô ô ó ê é ñ ò ó â á à á ä ê ë ô å à õ ç é á ö Ù µ Ú ± Û À Á º ½ Á Ü ± Ý Þ Û ± ± Parameter Name Default Value 0 1 2 3 UHS5 Handset Graphics Description SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 SHIFT 1 SHIFT 2 Button Activation On On Turn lights on. Off Off Turn lights off. Walk test Off On Off When set to On this causes a red LED to flash on the sensor when it detects movement. Use this feature to check for adequate sensitivity levels. Time ± Out ² ³ µ ± ¹ Lux on level º» ¼ ½ ¾ ± ± ¾ À ¹ Lux off level º» ¼ ½ ¾ ± ± ¾ À Á Á ¹ 20 mins 1, 10 & 20 minutes 5, 15 & 30 minutes 10 seconds Once the detector is turned on, this value sets how long the lights will stay on once movement has ceased. 9 2, 5 & 7 4, 6 & 9 Lux level setting to prevent the luminaires being switched on if the ambient light level is sufficient (adjustable between 1 and 9). The luminaires will always be switched on at level 9. 9 2, 5 & 7 4, 6 & 9 Lux level setting to switch the luminaires off during occupancy if the ambient light level goes above the setting (adjustable between 1 and 9). Level 9 will always keep the lights on. This setting can be used for window row switching. ÎÉ ÎÉ Sensitivity 9 1, 5 & 9 3, 6 & 8 Sensitivity level for detecting movement. 1 = low sensitivity 9 = high sensitivity Defaults D Returns the unit to the default settings. Presence / Absence Shift Presence Presence Absence Presence mode allows the output to turn on when movement is detected and off when movement ceases. Absence mode allows the output to turn off when movement ceases, but must be manually turned on first. Use this button to select the settings in red and blue signified by the Shift 1 and Shift 2 LEDs Fault finding What if the load does not turn ON? Check that the live supply to the circuit is good. Check that the load is functioning by bypassing the sensor (e.g. link terminals L and L/ Out on Channel1). If the detection range is smaller than expected, check the diagram on page 2. Rotating the sensor slightly may improve the detection range. ø ù ú û ü ý ù þ ÿ û ù þ ù ÿ ø ù ý û ÿ ù ÿ þ ù ÿ ù ù ù ÿ ù ù ù û ù û HINT: ÿ ÿø ÿø ÿ ÿø What if the load does not turn OFF? Ensure that the area is left unoccupied for longer than the Time Out Period. Ensure that the sensor is not adjacent to circulating air, heaters or lamps. 5

; ; Advanced programming Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Walk Test LED Off On or Off When set to On this causes a red LED to flash on the sensor when it detects movement. Use this feature to check for adequate sensitivity levels. Time Out! " # $ % & % ' 20 minutes 0-99 minutes Once the detector is turned on, this value sets how long the lights will stay on once movement has ceased. Select 0 for 10 second delay use for commissioning only. Manual Time Out 10 minutes 0-99 minutes When a manual operation occurs, either via the switch input or the infrared, it invokes the timeout period. Example 1: a detector in presence mode has a detector timeout of 15 minutes and a manual timeout of 3 minutes. When the user leaves the room they press the off button. The sensor will revert to automatic after 3 minutes, and then walking back in the room will turn the lights on. Example 2: using the settings above, the user turns the lights off (say for a presentation) but stays in the room. Every time a movement is detected, the manual timeout period is re-triggered, but when it doesn t pick up for the short timeout period, the sensor will timeout and revert to automatic. This means the lights may turn on inadvertently during the presentation, if the occupants are still for the manual timeout period, so adjust the timing carefully. Sensitivity On 9 1 (min) to 9 (max) Sensitivity level for detecting movement when the detector is already on. *UHS5 sets Sensitivity On and Off to the same value. Sensitivity Off 9 1 (min) to 9 (max) Sensitivity level for detecting movement when the detector is off. *UHS5 sets Sensitivity On and Off to the same value. Lux time 0 0 (disabled) 1-99 minutes If the detector measures the lux level and decides that the output needs switching on or off as a consequence, the lux time must elapse first. If at any time during the timed delay the lux change reverses then the process is cancelled. Lux Time enables absence detection to be implemented with a lux off level set. When the button is pressed, the lights will go on, regardless of ambient light level. However, if there is sufficient ambient light, they will turn off again after the Lux Time. ( ) * + *, - *., + / + 0 + 1 *, + - / + 2 * + 1 / - 3 4. 5 * 6, 5 4 7 1 + 4 4 + 8 9., + *, + 1 5 / - : 4 + / 6 + ) 1 7 1 + 4 + / 6 + ) 8 + 9 5 < *, + 3 5 =, * 4. + 1 + ) > * : + 6 - > 4 + ) < *, + 3 > 2 3 + 0 + 3 9 *, +?. 5 3 3 : + 5 ; ; + 8 5 - * + 3? * > 1 / + 8 ) / - = - 5 / < ) 1 - * 3 + - 4 * *, + @ > 2 A 5 + B Power Up State On On or Off Select No for a 30 second delay on start up. If Yes is selected, there will be no delay on start up and the detector will always power up detecting. Inhibit 4 seconds 1 to 999 seconds When the detector turns off, a delay is instigated to prevent retriggering. In certain circumstances this delay may not be enough. This parameter allows the delay to be changed. * * Factory default - - Restores factory default settings F G H I H J K L M J H J Detection Mode Presence Presence or Absence Lux on level N O % P Q R S R T & ' Lux off level N O % P Q R S R T W W ' 9 1 to 9 For a higher resolution a scale of 101-199 is available 9 1 to 9 For a higher resolution a scale of 101-199 is available Presence mode allows the output to turn on when movement is detected and off when movement ceases. Absence mode allows the output to turn off when movement ceases, but must be manually turned on first. Sets a minimum light level below which the PIR sensor is enabled, allowing lights to be turned on by movement. ( ) * + U *, + @ > 2 @ + 0 + 3 V < < 0-3 > + ; > 4 * - 3. -? 4 : + = 1 + - * + 1 *, - / *, + @ > 2 @ + 0 + 3 V / 0-3 > + B Sets a maximum light level above which the PIR sensor is disabled, preventing lights from being turned on by movement. C D E Override On - - If the lights are off, sending the IR command will turn them on immediately and revert to automatic operation using the manual timeout period. Override Off - - If the lights are on, sending the IR command will turn them off immediately. After the manual timeout period (described above), the sensor will revert to automatic. Cancel - - Cancels the on or off override, returning the detector to normal operation. F G H I X J Y M D E 1 position switch together 2 position switch together 6 Default - Short press on, long press off. - - Short press on, short press off.

This page intentionally left blank 7

Technical data Dimensions See diagrams opposite Weight 0.15kg Supply Voltage 230VAC +/- 10% Frequency 50Hz Maximum Load 10A of lighting and/or ventilation including incandescent, fluorescent, compact fluorescent, low voltage (by switching the primary of transformer). Power consumption On 875mW, Off 895mW EBDSM-PRM Terminal Capacity 2.5mm 2 Temperature -10ºC to 35ºC Humidity 5 to 95% non-condensing Material (casing) Flame retardant ABS and PC/ABS Type Class 2 IP rating 40 without gasket. 54 with gasket. Compliance EMC-2004/108/EC LVD-2006/95/EC Part numbers Part number Description Detector EBDSM-PRM Ceiling PIR presence detector Accessories UHS5 Programming IR handset UNLCDHS Universal LCD IR handset IMPORTANT NOTICE! This device should be installed by a qualified electrician inaccordance with the latest edition of the AS/NZS Wiring Rules and any applicable Building Regulations. Unit 16 1 Talavera Road Macquarie Park, NSW 2112 Australia T: 1300 697 627 F: (02) 9887 1333 www.mysmart.com.au Due to our policy of continual product improvement mysmart reserves the right to alter the specification of this product without prior notice. 8 Ref: #WD603 Issue 1