Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com

Similar documents
Technical Information Output Configurations for PLUS+1 Controllers powersolutions.danfoss.com

H1B Motor Electric Proportional Control L1, L2

MAKING MODERN LIVING POSSIBLE. Electrical Installation. Pulse Pickup KPP PPU. powersolutions.danfoss.com

Sensor EMD Speed Sensor

S42 Pump Electrical Displacement Control (EDC)

S45 Pump Electric Proportional Control

Electrohydraulic Actuators PVEA/H/S

MP1 Pumps Non-Feedback Proportional Electric (NFPE) Control

Sensors Q625A Remote Setpoint Module

Electrohydraulic Actuator Type PVEP / PVEP-F

Sensors ACE100B DC Millivolt Input Amplifier

MAKING MODERN LIVING POSSIBLE. Electrical Installation. M46 Pumps HC EDC. powersolutions.danfoss.com

MCX103A Non-Contact Rotary Position Sensor. Technical Information

ACX104B Potentiometer Rotary Position Sensor. Technical Information

Ultrasonic Controller/Sensor. Technical Information

POWER SYSTEM MODE STATUS

S5X Mobile Microcomputer. Technical Information 223,5 82,25 77,75 8,5 8,5 164,5 10,3. AMP Stecker AMP Connector 52,5 POWER SYSTEM MODE STATUS

MCHXXX Control Handle

PLUS+1 High Current Controller Family

Global Application Development Centers. Creating and proving solutions to customer challenges. A truly global team working for. you.

moog MSD Servo Drive Specification Option 2 - Technology TTL encoder with commutation signals

Figure 1: Motor model

TECHNICAL DATASHEET #TDAX022420

DeviceCraft Revision #1 11/29/2010

2.017 DESIGN OF ELECTROMECHANICAL ROBOTIC SYSTEMS Fall 2009 Lab 4: Motor Control. October 5, 2009 Dr. Harrison H. Chin

7I33 / 7I33TA MANUAL Quad analog servo amp interface

QC100 Quadrature Converter User Guide Rev 1.1g

PLUS+1 Inverters. Data sheet V1.2

PLUS+1 Inverters. Data sheet V1.4

Analog Servo Drive 25A20DD

Jaguar Motor Controller (Stellaris Brushed DC Motor Control Module with CAN)

Brushed DC Motor Control. Module with CAN (MDL-BDC24)

Optidrive Applications Support Library

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

7I33/7I33T MANUAL Quad analog servo amp interface

Section 11 Electronic Position Controls & Encoders

PFM 5000 Measuring Instrument

Hydraulic Valve Interface Products

PRELIMINARY AVB250A060 PRELIMINARY. Servo Drive. Peak Current (10 seconds)

1-2 VOLTS PER HERTZ CHARACTERISTICS EXERCISE OBJECTIVE

Technical Information. FDCA Fan Drive Control Assembly

TECHNICAL DATASHEET #TDAX021901

Autonomous Robot Control Circuit

introduction to Digital Electronics Install the Arduino IDE on your laptop if you haven t already!

MCHXXX. Simple to install MECHANICAL. HANDLE STROKE ± 30 (60 total travel)

Interfacing dspace to the Quanser Rotary Series of Experiments (SRV02ET)

SNAP Quadrature Input Module

Analog Servo Drive 30A8

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

MASTER/SLAVE TENSION CONTROL

PRELIMINARY. Preliminary TECHNICAL DATASHEET #TDAX DC MOTOR CONTROLLER P/N: AX100650

Lab 5: Inverted Pendulum PID Control

Embedded Control. Week 1 (6/29/11)

Programmable with Electronic Assistant Simulink

Analog Servo Drive 30A8

Analog Servo Drive 20A20

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

Lab Exercise 6: Digital/Analog conversion

X3M. Multi-Axis Absolute MEMS Inclinometer Page 1 of 13. Description. Software. Mechanical Drawing. Features

VISUAL PHYSICS ONLINE. Experiment PA41A ELECTRIC CIRCUITS

Analog amplifier RA. RE Edition: Replaces:

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

STEPPING MOTOR EMULATION

Position and Velocity Sensors

AN3134 Application note

TECHNICAL DATASHEET #TDAX ISOLATED DUAL CHANNEL UNIVERSAL SIGNAL CONVERTER

M Series RF Power Supply (Generator) Analog Interface Connections

USER MANUAL FOR THE LM2901 QUAD VOLTAGE COMPARATOR FUNCTIONAL MODULE

DIGITAL CONTROL OF ELECTRO-HYDRAULIC STEERING TEST BENCH

SPEED SENSORS SIGNAL CONDITIONERS. Standard & Custom Sensors, Signal Conditioners and Interface Electronics

Feed-back loop. open-loop. closed-loop

Digital amplifier for proportional valves PEM XD

Penny & Giles No-Contact, Rotary Position Sensor NRH271 & NRH272

Command Set For EZController Model EZCTRL. Document Revision: A08 12/05/10

Connection to the sensor is with simple flying leads for customer termination. 1 Page NRH300DP Rev B 09/15

Analog Amplifier RA. RE / /12 replaces: RE RE RE RE Technical Data Sheet

MTY (81)

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

BATCHMATE 1500 Batch Control Computer Technical Bulletin

Mach3 USB Motion Card (STB5100) Installation Manual

CAP6637A AC-DC Open Loop Converter

ACTUATORS AND SENSORS. Joint actuating system. Servomotors. Sensors

Analog Servo Drive 30A20AC

TECHNICAL DATASHEET #TDAX032100

Highly Integrated Inverter with Multiturn Encoder and Software-based PFC for Low Cost Applications

Series + accesories DLA

Water Cooled Active Resistance DC Electronic Load

Mechatronics Engineering and Automation Faculty of Engineering, Ain Shams University MCT-151, Spring 2015 Lab-4: Electric Actuators

Microprocessors B Lab 4 Spring Motor Control Using Pulse Width Modulation (PWM)

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

Dynamo Brushless DC Motor and GreenDriveTM Manual

Application Note # 5438

LV-Link 3.0 Software Interface for LabVIEW

ENGR4300 Test 3A Fall 2002

Coils & Electronic Controls

CHAPTER 7 HARDWARE IMPLEMENTATION

BODAS Controller RC Series 22

Speed and Key Monitor Specifications

P/N: AX TECHNICAL DATASHEET #TDAX Single Input, Dual Output Valve Controller 1 Universal Input, +5V reference CAN (SAE J1939)

P/N: AX Ordering Part Numbers: SAE J1939 Controller: For baud rate, refer to the table below for the appropriate P/N. Mating Plug Kit: AX070123

Transcription:

MAKING MODERN LIVING POSSIBLE Tech Note Input Configurations for PLUS+1 Controllers powersolutions.danfoss.com

About this manual This publication is intended to share circuits, products and other useful application information not otherwise found in other Danfoss publications. It is written to inform and aid the reader in the successful application of Danfoss products. Revision history Revision date Page Change Remarks 07/18/2005 Initial release 10/11/2005 8, 9 Content revision Rev-A 12/08/2005 Various Drawing and content changes Rev-B 17 Sep 2013 All New layout Rev-C 2 520L0931 Rev CA Sep 2013

Contents PLUS+1 Controllers Configurable Inputs Overview... 4 Switch connected to ground... 4 Switch connected to +battery... 5 Two position switch connected to +battery or ground... 6 Three position switch connected to +battery or ground... 7 Quadrature encoder... 8 Phase shift measurement... 9 Temperature sensor or rheostat... 10 4-20 milliampere sensor... 11 Pulse pickups (PPU)... 12 Battery operated PPU... 12 +5 Vdc operated PPU... 12 Inductive 2-wire PPU... 13 Open collector PPU... 13 Potentiometers (control handles, setpoint knobs, etc.)... 14 520L0931 Rev CA Sep 2013 3

PLUS+1 controllers configurable inputs Overview PLUS+1 controllers have a number of different input types. Here are some examples and how to use them to interface with different types of external devices. Please refer to the Application Programming Interface (API) for the particular hardware you are using for more details and the latest information on voltage ranges, etc. The API specifications for each hardware module are available in the hardware tab in PLUS+1 GUIDE. Switch connected to ground +BATT To Digin PLUS+1 Input 2308 This type of input could be read by a number of different PLUS+1 input types. PLUS+1 input types Digital input (DIN) Configuration should be set to provide an internal pull-up resistor to +5 Vdc. This will be activated with a ground signal. (PinConfig = 1) Digital/analog input (DIN/AIN) Configuration should be set to provide an internal pull-up resistor to +5 Vdc. (PinConfig0 = 1) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) Multifunction: digital/analog/frequency input (DIN/AIN/FreqIN) Configuration should be set to provide an internal pull-up resistor to +5 Vdc. (PinConfig0 = 1) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) Frequency configuration, if available, should be set to provide no additional measurement modes. Analog input (AIN) Although this is not a recommended method, it could be used if all other input types have been used. In this case an analog measurement is used and a GUIDE application must be developed to determine if the signal is true or false. Configuration should be set to the normal analog input. 4 520L0931 Rev CA Sep 2013

Switch connected to +Battery +BATT To Digin PLUS 1 Input 2309 This type of input could be read by a number of different PLUS+1 input types. PLUS+1 input types Digital input (DIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig = 2) Digital/analog input (DIN/AIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 2) Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Multifunction: digital/analog/frequency input (DIN/AIN/FreqIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 2) Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Frequency configuration, if available, should be set to provide no additional measurement modes. Analog input (AIN) Although this is not a recommended method, it could be used if all other input types have been used. In this case an analog measurement is used and a GUIDE application must be developed to determine if the signal is true or false. Configuration should be set to the normal analog input. Normal range of the input is 0 to +5.25 Vdc. Obviously, battery voltage is higher than that, but the input will just saturate to the highest reading. 520L0931 Rev CA Sep 2013 5

Two position Switch connected to +battery or ground +BATT To Digin PLUS 1 Input 2310 This type of input could be read by a number of different PLUS+1 input types. PLUS+1 input types Digital input (DIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig = 2) Digital/analog input (DIN/AIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 2) Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Multifunction: digital/analog/frequency input (DIN/AIN/FreqIN) Configuration should be set to provide an internal pull-down resistor to ground. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 2) Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Frequency configuration, if available, should be set to provide no additional measurement modes. Analog input (AIN) Although this is not a recommended method, it could be used if all other input types have been used. In this case an analog measurement is used and a GUIDE application must be developed to determine if the signal is true or false. Configuration should be set to the normal analog input. Normal range of the input is 0 to +5.25 Vdc. Obviously, battery voltage is higher than that, but the input will just saturate to the highest reading. 6 520L0931 Rev CA Sep 2013

Three position Switch connected to +battery or ground With this type of input an application could be setup to get three switch states from a single PLUS+1 input. This could be done with a multifunction input or possibly a digital/analog input. Switch states: y When the switch is in the up position, +Batt voltage will be applied to the input. The analog reading will be at +Batt voltage. y When the switch is in the middle position, no voltage will be applied to the input. The analog reading will be about 2.5 Vdc due to the internal voltage divider. y When the switch is in the down position, ground will be applied to the input. The analog reading will be 0 Vdc. PLUS+1 input types Digital input (DIN) This cannot be done by a straight digital input. It needs to be able to read the voltage. Digital/analog input (DIN/AIN) Configuration should be set to provide an internal pull-up/pull-down configuration. This configuration may not be available on some templates. (PinConfig0 = 3) Configuration should be set to 36 Volt range. (PinConfig1 = 1) The application program can either use the Multi_Dig_In function block set for three outputs or the programmer can write his own application to decode the signal voltage levels. Multifunction: digital/analog/frequency input (DIN/AIN/FreqIN) Configuration should be set to provide an internal pull-up/pull-down configuration. (PinConfig0 = 3) Configuration should be set to 36 Volt range. (PinConfig1 = 2) Frequency configuration, if available, should be set to provide no additional measurement modes. The application program can either use the Multi_Dig_In function block set for three outputs or the programmer can write his own application to decode the signal voltage levels. Analog input (AIN) This type input cannot be used because the configuration cannot be set to provide an internal pull-up/pull-down configuration. 520L0931 Rev CA Sep 2013 7

Quadrature encoder +BATT Encoder A B PLUS 1 Master Input PLUS 1 Slave Input 2311 This type of input can only be read by multifunction PLUS+1 inputs. Encoders must be connected to multifunction inputs that are setup for quadrature encoders. They can measure the number of counts that have occurred during the last loop time and the direction of rotation. They can also measure the amount of phase shift time (see Phase shift measurement, page 9). The maximum input frequency for these measurements is 4 khz. Above that frequency there is a chance that some pulses could be missed. PLUS+1 input type Multifunction: Digital/analog/frequency input (DIN/AIN/FreqIN) Only certain multifunction inputs are capable of handling quadrature encoders. Please refer to the API for the particular hardware you are using for more details. Quadrature encoders must be connected to multifunction inputs in pairs. The A channel should be connected to the master input and the B channel should be connected to the slave input. Configuration should be set to provide an internal pull-up/pull-down configuration depending on the output structure of the encoder. Check the vendor specifications. Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Frequency configuration should be set to quad encoder enabled. (FreqConfig = 1) When quad encoder measurement is enabled, then the QuadCount value will be valid. When read, this value will give the number of measured counts during the last loop time. The sign of the value will indicate the direction of rotation. 8 520L0931 Rev CA Sep 2013

Phase Shift measurement Input Freq A Input Freq B PLUS 1 Master Input PLUS 1 Slave Input 2312 Phase shift between two input frequencies can be read by multifunction PLUS+1 inputs. The signals must be connected to multifunction inputs that are setup for quadrature encoders. The maximum input frequency for these measurements is 4 khz. Above that frequency there is a chance that some pulses could be missed. PLUS+1 input type Multifunction: Digital/analog/frequency input (DIN/AIN/FreqIN) Only certain multifunction inputs are capable of handling phase shift measurements. Please refer to the API for the particular hardware you are using for more details. Phase shift measurements must be connected to multifunction inputs in pairs. One channel should be connected to the master input and the other channel should be connected to the slave input. Configuration should be set to provide an internal pull-up/pull-down configuration depending on the output structure of the sensors providing the frequency inputs. Check the vendor specifications. Configuration should be set to 5.25 Volt range. This is necessary for proper operation as a digital input. (PinConfig1 = 0) Frequency configuration should be set to phase shift enabled. (FreqConfig = 2) When phase shift measurement is enabled, then the phase value will be valid. When read, this value will give the time of the phase shift between the A and B signals in tenths of microseconds. The sign of the value will indicate the direction of rotation. 520L0931 Rev CA Sep 2013 9

Temperature sensor or rheostat +5 V DC Rheostat or Temperature Sensor 1330 ohms PLUS 1 Input To A/D 2313 This type of input can only be read by a temperature/rheostat PLUS+1 input type. y This input is capable of measuring an external variable resistance of 0 to 10kΩ. y Although it can go as high as 10kΩ, the measurement will have better resolution at the lower resistance values due to the non-linearity of the resultant voltage to the A/D. y For best results use sensors or rheostats that have a maximum resistance of less than 1kΩ. PLUS+1 input type Analog/temperature/rheostat input (AIN/TEMP/RHEO) Configuration should be set to temperature/rheostat mode. (PinConfig = 1) Value is read in ohms. 10 520L0931 Rev CA Sep 2013

4-20 milliampere SENSOR Sensor +Batt 4-20 ma PLUS 1 Input External 18 ohm Resistor To A/D Sensor Ground 2314 There is not a PLUS+1 input specifically designed for a 4-20 ma sensor. However, this type of input could be read by a multifunction input, if it is wired as shown above with an external resistor. An 18Ω resistor provides an input signal voltage range of 0.072 to 0.36 Vdc. A 200Ω resistor provides an input signal voltage range of 0.8 to 4.0 Vdc. PLUS+1 input type Digital/analog input (DIN/AIN) Recommended external resistor is 200Ω. Other resistor values can be utilized, but the voltage range will be different than 0.8 to 4.0 Vdc. Configuration should be set to provide no pull-up or pull-down resistor. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 0) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) Multifunction: digital/analog/frequency input (DIN/AIN/FreqIN) Recommended external resistor is 18Ω. Other resistor values can be utilized, but the voltage range will be different than 0.072 to 0.36 Vdc. This input could also use the 200Ω value, if desired, by setting the voltage range to 5.25 Vdc. Set the configuration to provide no pull-up or pull-down resistor. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 0) Set the voltage range to 0.3675 Vdc. (PinConfig1 = 1) Frequency configuration, if available, should be set to provide no additional measurement modes. Analog/temperature/rheostat input (AIN/TEMP/RHEO) Not recommended since the minimum voltage range is 0 to 5.25 Vdc Analog/CAN shield input (AIN/CAN/Shield) Not recommended since the minimum voltage range is 0 to 5.25 Vdc 520L0931 Rev CA Sep 2013 11

Pulse Pickups (PPU) PLUS+1 hardware will work with virtually any Pulse Pickup (PPU). This is because a number of voltage ranges and pull-up/pull-down configurations are available. The user should refer to the API document for details of the voltage ranges and the threshold values for a particular PLUS+1 hardware. Users should also refer to the pulse pickup manufacturer s data sheet for details on the PPU output configuration. The PPU can only be read by a PLUS+1 multifunction (DIN/AIN/FreqIN) input. Frequency configuration can be set to any mode, but normally no additional measurement mode is needed. Available measurements are frequency, period, pulse counting, or duty cycle. Battery operated PPU +5 V DC +BATT Pulse Pickup Multi-Function Input 2315 PLUS+1 multifunction input type Battery operated PPU Configuration should be set to provide an internal pull-up/pull-down configuration. (PinConfig0 = 3) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) +5 Vdc operated PPU +5 V DC Potentiometer PLUS 1 Input To A/D Sensor Ground 2316 PLUS+1 multifunction input type +5 Vdc operated PPU Configuration should be set to provide an internal pull-up/pull-down configuration. (PinConfig0 = 3) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) 12 520L0931 Rev CA Sep 2013

Pulse Pickups (PPU) (continued) Inductive 2-wire PPU +5 V DC Inductive Pulse Pickup Multi-Function Input 2317 PLUS+1 multifunction input type Inductive 2-wire PPU Configuration should be set to provide an internal pull-up/pull-down configuration. (PinConfig0 = 3) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) Open collector PPU For an open collector PPU, you must have a pull up resistor that is external to the PPU. This can be provided by the PLUS+1 controller by setting the input pin configurations as follows. +5 V DC or +BATT +5 V DC Open Collector Pulse Pickup Multi-Function Input 2318 PLUS+1 multifunction input type Open collector PPU Configuration should be set to provide an internal pull-up resistor to +5 Vdc. (PinConfig0 = 1) Configuration should be set to 5.25 Volt range. (PinConfig1 = 0) 520L0931 Rev CA Sep 2013 13

Potentiometers (Control Handles, Setpoint Knobs, etc.) As shown below there are two ways to wire a potentiometer to a PLUS+1 controller. The first method is recommended. The second method is acceptable, if you can deal with the limitations. Recommended wiring this will give you the most accurate readings. The +5 Vdc supply from the PLUS+1 controller is regulated and the ground return goes back to the controller. Alternate wiring this will give you roughly the same results. However, the battery voltage can fluctuate and there may be some voltage differential between the ground of the potentiometer and the ground in the PLUS+1 controller. Either of these two conditions can cause the analog voltage reading to fluctuate. Of course you will also need to use the high voltage range on the analog input. Recommended wiring Alternate wiring +5 V DC +BATT Potentiometer PLUS 1 Input To A/D Potentiometer PLUS 1 Input To A/D Sensor Ground 2319 2320 PLUS+1 input types Analog input (AIN) No configuration is necessary. Range is normally 0 to 5.25 Vdc so the alternate wiring shown above is not applicable. Digital/analog input (DIN/AIN) Configuration should be set to provide no pull-up or pull-down resistor. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 0) For 5 Vdc input set the configuration to 5.25 Volt range. (PinConfig1 = 0) For up to 36 Vdc input set the configuration to 36 Volt range. (PinConfig1 = 1) Multifunction (digital/analog/frequency) input (DIN/AIN/FreqIN) Configuration should be set to provide no pull-up or pull-down resistor. This will be activated with a voltage from +5 Vdc to battery voltage. (PinConfig0 = 0) For 5 Vdc input set the configuration to 5.25 Volt range. (PinConfig1 = 0) For up to 36 Vdc input set the configuration to 36 Volt range. (PinConfig1 = 2) Frequency configuration, if available, should be set to provide no additional measurement modes Analog/temperature/rheostat input (AIN/TEMP/RHEO) Configuration should be set to normal analog input No range configuration this is usable for the 5 Vdc input only Analog/CAN shield input (AIN/CAN Shield) No range configuration this is usable for the 5 Vdc input only This input can be used if a CAN shield is not used in the system 14 520L0931 Rev CA Sep 2013

Notes 520L0931 Rev CA Sep 2013 15

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Danfoss Your Strongest Partner in Mobile Hydraulics. Go to www.powersolutions.danfoss.com for further product information. Wherever off-highway vehicles are at work, so is Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Please contact the Danfoss Power Solution representative nearest you. Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmuellerinverter.com Turolla www.turollaocg.com Valmova www.valmova.com Hydro-Gear www.hydro-gear.com Daikin-Sauer-Danfoss www.daikin-sauer-danfoss.com Local address: Danfoss Power Solutions US Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Danfoss Power Solutions GmbH & Co. OHG Krokamp 35 D-24539 Neumünster, Germany Phone: +49 4321 871 0 Danfoss Power Solutions ApS Nordborgvej 81 DK-6430 Nordborg, Denmark Phone: +45 7488 2222 Danfoss Power Solutions 22F, Block C, Yishan Rd Shanghai 200233, China Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 520L0931 Rev CA Sep 2013 www.danfoss.com Danfoss A/S, 2013-09