NBASE-T Copper Transceiver Small Form Factor Pluggable (SFP+), 3.3V 100M/1G/2.5G/5G/10Gbps Ethernet. Features

Similar documents
1000BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 1.25Gbps Gigabit Ethernet. Features

SNR-SFP100-T. SNR-SFP100-T 10/100M Copper SFP Series

407-BBOS-A 407-BBOS-A. Features. Up to 1.25Gb/s bi-directional data links. Hot-pluggable SFP footprint

FCOPPER-SFP BASE-TX Copper SFP Transceiver

1000BASE-T SFP Copper Transceiver Hot Pluggable, Cat-5 UTP Cable, 100m

SFP- GE- RJ45- AO. 1.25Gbps SFP Copper Transceiver

SFP-LX 1.25Gb/s Single-Mode SFP Transceiver 1000BASE-LX Gb/s Fiber Channel

1000BASE-T Copper SFP Transceiver

SFP+ Dual LC 10G SMF 10Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

TS-SF-T BASE-T Copper SFP Transceiver

SFP+ Dual LC 10G MMF 300m 850nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

1000BASE-T Copper SFP Transceiver

Optical Transceiver Module - SFP

10G CWDM SFP+ 40km ER Transceiver Hot Pluggable, Duplex LC, +3.3V, 1470~1610nm CWDM EML, DDMI PSFP10-1C41SF-XX

SFP+ Copper 10GBase-T SL-SFP-10G-T

10GBase LR-Lite SFP+ Optical Transceivers (I-Temp)

10GBase SFP+ LR/LW Optical Transceivers Series WST-SFP+LR-C

10GBASE-T Copper SFP+ Transceiver SFP+-10GBASE-T

LX21 100Mb/s to 1.25Gb/s BX-U

Product Features. Applications. Descriptions. Ordering Information. Pin Description

10G SFP+ CWDM 20km Transceiver Hot Pluggable, Duplex LC, +3.3V, 1270~1350nm CWDM DFB, DDMI PSFP-2C41SF-XX

SFP-SW10100-R-TP 10/100/1000 BASE-T Copper SFP Transceiver

LTF8506 SFP+ AOC 10G Ethernet SFP+ Active Optical Cable

OP6C-TX1-00-C2 Datasheet

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Single Mode, 10km, DFB Optical Transceiver PSFP SF

Part Number Transmitter Output Power Receiver Sensitivity Reach Temp DDM RoHS

Product Features Applications Descriptions Ordering Information

SFP+ 10G Transceiver M10GB-SFP-BIDI10

10GBase SR/SW SFP+ Optical Transceivers WST-SFP+SR-C

SFP 4.25G 850nm Multi mode Optical Transceiver

Specification. Small Form Factor Pluggable Duplex LC Receptacle SFP+

AXGE Gbps Single-mode 1310nm, SFP Transceiver

Features: Compliance: Applications. Warranty: AH-ACC-SFP-1G-T-GT Gigabit Ethernet SFP Module TX 10/100/1000Mbps Aerohive Compatible

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

Specification. T B S - S x C K 1 - F 1 1

1000BASE-T Copper SFP Transceiver

OCTECH 1.25Gbps SFP Transceiver

SPG-FE-FX-IDFC SPG-FE-FX-CDFC

4.25Gbps SFP Transceiver

SO-SFP-100Base-T. SFP, 125Mbps FE to 10/100Base-T convert SO-SFP-100BASE-T OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

PRE-SFP-OC Gb/s Transceiver, 1310 nm, 15 km (IR1), DDM

AA E6-A AA E6-A. Features. Up to 1.25Gb/s Data Links. Hot-Pluggable. Duplex LC connector. Up to 10km on 9/125μm SMF

1.25Gbps Single Fiber Bi-directional SFP, ONU Transceiver

SFP Cooper 1000Base-T 100M SL-SFP-3T-XX

SPL EBX-IDFM SPL EBX-IDFM

2.5Gbps SFP Transceiver

SFP-1.25G-LX 1.25Gbps SFP Optical Transceiver, 10KM Reach

Product Specification

SFP CWDM 1.25G nm Single mode Optical Transceiver

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

10Gb/s SFP+, Hot Pluggable, Duplex LC, +3.3V, 1310nm, Multi Mode, 220m FP-LD Optical Transceiver PSFP MF

SFP+ ER TDM 1550nm 10G SMF 40km Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

1310nm SFP28 Single-Mode Transceiver, With DDM and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type Gbps 1310nm and DFB 28.

Shenzhen Hilink Technology Co.,Ltd

Specification. T S P - S x C H 1 - C 1 1

OCTECH 1.25Gbps SFP Transceiver

PRE-SFP-OC Mb/s Transceiver, 1310 nm, 15 km (IR1), DDM

T S P S x A A 1 M 1 T

T S D S x C B 1 K 1 1

T A S A 5 N B 1 F A H

SFP Dual LC 1.25G SMF 20Km 1310nm Transceiver. Features. Applications. Ordering Information APPLIED OPTOELECTRONICS, INC.

TPP3XGDS0x000E2G 850nm SFP+ Transceiver

DWDM SFP Optical Transceiver

Features. MIL-STD-883E Method FDA 21CFR and Compliant with Class I laser product. RoHS 2011/65/EU Compliant with RoHS

MULTIMODE SFP TRANSCEIVER

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

Features. Feature Standard Performance. MIL-STD-883E Method

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

125Mbps~155Mbps Multimode 850nm, SFP Transceiver

A block diagram of the HSFP10-2C21XX SFP+ optical transceiver is shown below

DWDM SFP 2.5G 120KM LC Duplex SLSD-25XX-120-D

T B B S x C D 2 G A M

Specification. Small Form Factor Pluggable Duplex LC Receptacle SFP. Optical Transceivers 1000BASE-SX 1250Mbit/s. Ordering Information

6Gbps SFP+ Optical Transceiver,10 Km (OP3B10D ) Hot Pluggable, Duplex LC, +3.3V 1310nm DFB-LD. Features

Features. Feature Standard Performance. MIL-STD-883E Method FDA 21CFR and EN (IEC) ,2 2002/95/EC 4.1&4.

SFP+ 16G 1310nm Single mode Optical Transceiver

LEG. 10Gbs SFP+ Transceiver

DWDM SFP Series. Laser

EPON-OLT-SFP-20. Features. Applications. Standard. 1.25G OLT 20km transmission

SFP28 Series Preliminary EOLP-1325G-10-RX. Features. Applications. Ordering information

SFP Series. EOLS X Series. Features. Applications. Ordering Information

PT (2)-1W. OC-3 SR/IR-1 / STM S-1.1 SFP Transceiver

155Mbps Single-mode 1310nm, SFP Transceiver

Features. RX Sensitivity (dbm) TX Power (dbm) Voltage (V) SFP-Dual-LC 1.25G MMF 2Km ~ -9 < AC/AC TTL N -5 ~ +70 A56L-BN13-A6MA

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

SFP+ Cable Assemblies, 0.5m/1m/2m/3m/4m/5m/6m/7m/8m/9m/10m/11m/12m/15m Reach RoHS6 Compliant. Lengt

GLC-SX-MM-LEG. 1.25Gbps SFP Transceiver

GLC-BX-D-80-A GLC-BX-D-80-A. Features. Up to 1.25Gb/s Data Links. Hot-Pluggable. Single LC connector. Up to 80 km on 9/125μm SMF

JD061A-C. 1.25Gbps SFP Transceiver

SFP 155Mb/s Transceiver 2km Hot Pluggable, Duplex LC, +3.3V, 1310nm FP-LD MM PSFP M-12F

FEU3411P-2DC-1 Optical Transceiver for E-PON ONU, 10~20km Reach

ROHS Compliant MM SFP Transceiver 1.25Gb Gigabit Ethernet

E-PON OLT PX-30 Transceiver

1.25Gb/s 160km DWDM SFP Transceiver (OP340GD-D ) Hot Pluggable, Duplex LC, 100GHz, DWDM DFB & APD, Single-mode, DDM

SFP Series EOLS X. Features. Applications. Ordering Information

GPH-3102-L1C(D) 100BASE-LX Spring-Latch SFP Transceiver, 10km Reach

PRE-SFP-B Gb/s Bi-Di Transceiver, 1550/1310nm Tx/Rx, 40km, DDM

1.25Gbps SFP Transceiver

Transcription:

Features 10Gbps Links up to 35 m using Cat 6a/7 Cable 100M/1G/2.5G/5Gbps Links up to 100 m using Cat5e Cable Low Power Consumption 2.2W Max, 35m @ 10Gbps, 75 C 1.88W Max, 100m @ 2.5G and 5Gbps, 75 C 1.88W Max, 100m @ 100M and 1Gbps, 75 C IEEE 802.3az/bz Compliant SFF-8431 and SFF-8432 MSA Compliant Access EEPROM/PHY IC via 2-wire Serial Bus I2C to MDIO Bridge (Support IEEE 802.3 Clause 45) Fast Retrain and EMI Cancellation Algorithm Compliant with RoHS. +3.3V Single Power Supply Temperature Range 0 C to +75 C Application NBASE-T WiFi AP to existing 10Gbps Switch Bridge 10Gbps Ethernet over Category 6a/7 Cable Distributed multi-processing High speed I/O for file server or high-end workstation Switch/Router to Switch/Router Link Description ASFPT-TNBT Copper SFP transceiver acts as physical layer function of using Cat5e, Cat6a or Cat7 twisted-pair cable. It bridges new NBASE-T device (such as Wi-Fi AP) to legacy 10G switch for seamless connection between new and old Ethernet standard. It also supports auto-negotiation with any 100M/1G/2.5G/5G/10Gbps link partner. The Copper SFP transceiver is designed fully compliant with IEEE 802.3 standard and connects to network through isolated transformer. It can be programmed to fix operating speed or auto-negotiation with advertised capabilities. ASFPT-TNBT Copper SFP transceiver features simple application in data center network at 10Gbps and allows link up 35 meters. It really enables a new dimension of flexibility for Network Equipment designer or data center facility planner to optimize capital expense. ASFPT-TNBT Copper SFP transceiver provides standard serial ID information compliant with SFP MSA, which can be accessed with address of 0xA0 via the 2-wire serial CMOS EEPROM protocol. The physical IC can be also accessed via 2-wire serial bus at address 0xAC for a write and 0xAD for a read. Detail protocol refers to I2C to MDIO Bridge section. Page 1 of 10

Ordering Information PART NUMBER Product Name ASFPT-TNBT NBASE-T Copper SFP Absolute Maximum Ratings PARAMETER SYMBOL MIN MAX UNITS NOTE Storage Temperature Ts -45 90 C Storage Humidity Hs 5 90 % Recommended Operating Conditions PARAMETER SYMBOL MIN MAX UNITS NOTE Operating Temperature T 0 75 C Case Temperature Operating Humidity Ho 10 85 % Supply Voltage Vcc 3.135 3.465 V Typ. 3.3V Surge Current Isurge 30 ma Hot Plug Cable Length Operating Conditions PARAMETER SYMBOL MAX UNITS NOTE 10Gbps @35M Cat7 I 670 ma (1), (2), (4) 5Gbps @100M Cat5e I 570 ma (1), (3), (4) 2.5Gbps @100M Cat5e I 570 ma (1), (3) 1Gbps @100M Cat5e I 570 ma (1), (3) 100Mbps @100M Cat5e I 570 ma (1), (3) Note: (1) Chamber = 60 C, measurement after traffic 30 minutes without packet loss. (2) Single Cat7 35M cable without series. (3) Single Cat5e 100M cable without series. (4) Case temperature measurement is around chamber temperature + 22~23 C. Thus, ambient temperature should be controlled under 50 C for proper operation. Network switch with good air flow/temperature control at 25 C, case temperature should be less than 50 C. Page 2 of 10

Electrical Characteristics PARAMETER SYMBOL MIN TYP. MAX UNITS NOTE Transmitter Data Input differential Voltage V D, TX 110 1000 mv (1) Differential Input Impedance Z TX 100 Ohm Transmitter Disable Input-High V Dish N/A V Not implement Transmitter Disable Input-Low V DISL N/A V Not implement Receiver Data Output Differential Voltage V D, RX 370 800 mv (3) Differential Output Impedance Z RX 100 Ohm LOS Output Voltage High VSDHL 2.4 V cc V (2) LOS Output Voltage Low VSDL 0 0.5 V (2) Note: (1) Internally AC coupled to PHY chip. (2) Pull up to VCC with a 4.7K 10K Ohm resistor on host Board (3) Internally AC coupled, but requires a 100 Ohm differential termination at MAC side. Page 3 of 10

Block Diagram of Transceiver LOS Function The SFP MSA specification defines a pin called LOS to indicate loss of signal to the motherboard. This should be pulled up with a 4.7K to 10K resistor. Pull up voltage between 2.0V and Vcc-T/R+0.3V. When high, this output indicates link fail. Low indicates normal operation. In the low state, the output will be pulled to <0.5V. Termination Circuits Inputs to the transceiver are AC coupled and internally terminated through 50 ohms. The input signal must have at least an 110mV differential peak-to-peak signal swing. Output from the receiver section of the module is also AC coupled and is expected to drive a 50 ohm load. Different termination strategies may be required depending on the particular Serializer/Deserializer chip set used. The transceiver is designed with AC coupled data inputs and outputs to provide the following advantages: Close positioning of SERDES with respect to transceiver; allows for shorter line lengths and at high speeds reduces EMI. Minimize number of external components. Internal termination reduces the potential for un-terminated stubs which would otherwise increase jitter and reduce transmission margin. Page 4 of 10

Subsequently, this affords the customer capability to optimally locate the SERDES as close to the transceiver as possible and save valuable real estate. At 10Gbps rates this can provide a significant advantage resulting in better transmission performance and accordingly better signal integrity. Power Coupling A suggested layout for power and ground connections is given in Figure 1 below. Connections are made via separate voltage and ground planes. The mounting posts are at case ground and should not be connected to circuit ground. The ferrite bead should provide a real impedance of 50 to 100 ohms at 100 to 1000 MHz. Bypass capacitors should be placed as close to the 20 pin connector as possible. Figure 1: Suggested Power Coupling Serial Communication Protocol APAC ASFPT-TNBT supports the 2-wire serial communication protocol defined in the SFP MSA. This SFP uses a 256 bytes EEPROM with an address of 0xA0. The physical layer IC can also be accessed via the 2-wire serial bus at address 0xAC/0xAD. See I2C to MDIO Bridge section. Page 5 of 10

EEPROM Serial ID Memory Contents Accessing Serial ID Memory uses the 2 wire address 10100000 (A0H). Memory Contents of Serial ID are shown in Table 1. Table 1 Serial ID Memory Contents Size Addr. Name of Field Hex Description (Bytes) 0 1 identifier 03 SFP or SFP+ 1 1 Ext.Identifier 04 GBIC/SFP function is defined by two-wire interface ID only 2 1 Connector 22 RJ45 3-10 8 Transceiver XX XX XX XX XX XX Transceiver Code 11 1 Encoding 00 12 1 BR(Nominal) 64 10Gbps 13 1 Rate Identifier 00 Unspecified 14 1 Length(SMFm)-km 00 N/A 15 1 Length(SMF) 00 N/A 16 1 Length(50µm) 00 N/A 17 1 Length(62.5µm) 00 N/A 18 1 Length(cable) 23 35(units of meters) 19 1 Length(OM3) 00 N/A 20-35 16 Vendor name XX XX XX XX XX XX XX 20 20 20 20 20 20 20 20 20 Vendor name (ASCII) 36 1 Transceiver 00 Unallocated 37-39 3 Vendor OUI XX XX XX Vendor OUI 40-55 16 Vendor PN XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX Transceiver part number 56-59 4 Vendor rev XX XX XX XX Vendor rev 60-61 2 Wavelength 00 0nm 62 1 Unallocated 00 Unallocated 63 1 CC_BASE Check Sum (Variable) Check code for Base ID Fields 64-65 2 Options 00 02 RATE_SELECT functionality is implemented 66 1 BR 00 max 67 1 BR 00 min 68-83 16 Vendor SN 41 34 32 30 33 30 30 34 20 20 20 Serial Number of transceiver (ASCII). 20 20 20 20 20 For example A4203004. 84-91 8 Date code XX XX XX XX XX XX XX XX Manufacture date code 92 1 Diagnostic Monitoring Type 00 N/A 93 1 Enhanced Options 00 N/A 94 1 SFF-8472 Digital diagnostic function not 00 Compliance included or undefined 95 1 CC_EXT Check Sum (Variable) Check sum for Extended ID Field. 96-127 32 Vendor Specific Read only Depends on customer information Note: The XX byte should be filled in according to practical case. For more information, please refer to the related document of SFP Multi-Source Agreement (MSA). Page 6 of 10

I2C to MDIO Bridge ASFPT-TNBT has MCU inside to bridge host I2C to communicate with PHY MDIO interface. The I2C at slave address 0xAC for a write and 0xAD for a read. MDIO write sequence : 6 bytes I2C frame are required. 1 st byte : 0xAC (8bits) 2 nd byte : 0b 000 + DEVAD (5 bits) 3~4 bytes : Register Address (16 bits) 5~6 bytes : Write Data (16 bits) MDIO read sequence : 7 bytes I2C frame are required. 1 st byte : 0xAC (8bits) 2 nd byte : 0b 001 + DEVAD (5 bits) 3~4 bytes : Register Address (16 bits) Delay >1 ms (Important: for MCU access PHY through MDIO) 5 th byte : 0xAD (8bits) 6~7 bytes : Read Data (16 bits) Example: Page 7 of 10

Connection Diagram Pin-Out PIN 11 PIN 20 PIN 10 PIN 1 Pin Signal Name Function NOTES 1 VeeT Transmitter Ground VeeT and VeeR are connected in SFP. 2 TX_FAULT Transmitter Fault Indication Not Implemented. Tied to VeeT in SFP. 3 TX_DISABLE Transmitter Disable Not Implemented. Floating in host. 4 MOD DEF (2) Module Definition 2 Data Line for Serial ID. 5 MOD DEF (1) Module Definition 1 Clock Line for Serial ID. 6 MOD DEF (0) Module Definition 0 Tied to Vee in SFP. 7 RATE SELECT Not Implemented Not implemented. 8 LOS Loss of Signal See LOS option. 9 VeeR Receiver Ground VeeT and VeeR are connected in SFP. 10 VeeR Receiver Ground VeeT and VeeR are connected in SFP. 11 VeeR Receiver Ground VeeT and VeeR are connected in SFP. 12 RD- Inverted Received Data out AC coupled 100 ohm differential high speed data lines. 13 RD+ Non-Inverted Received Data out AC coupled 100 ohm differential high speed data lines. 14 VeeR Receiver Ground VeeT and VeeR are connected in SFP. 15 VccR Receiver Power VccR and VccT are connected in SFP. 16 VccT Transmitter Power VccR and VccT are connected in SFP. 17 VeeT Transmitter Ground VeeT and VeeR are connected in SFP. 18 TD+ Non-inverted Data In AC coupled 100 ohm differential high speed data lines. 19 TD- Inverted Data In AC coupled 100ohm differential high speed data lines 20 VeeT Transmitter Ground Veet and VeeR are connected in SFP Page 8 of 10

Notes: 1. TX Fault is not used and is always tied to ground. 2. TX Disable as described in the MSA is not applicable to the copper SFP module. 3. Mod-Def 0,1, 2. These are the module definition pins. They should be pulled up with a 4.7-10 K resistor on the host board to a supply less than VCCT + 0.3 V or VCCR + 0.3 V. 4. RD-/+: These are the differential receiver outputs. They are AC coupled 100 Ohm differential lines which should be terminated with 100 ohm differential at the user SerDes. The AC coupling is done inside the module and is thus not required on the host board. 5. VCCR and VCCT are the receiver and transmitter power supplies. They are defined as 3.3 V ± 5% at the SFP connector pin. 6. TD-/+: These are the differential transmitter inputs. They are AC coupled differential lines with 100 Ohm differential termination inside the module. The AC coupling is done inside the module and is thus not required on the host board. Page 9 of 10

Drawing Dimensions Mating of SFP Transceiver to SFP Host Board Connector The pads on the PCB of the SFP transceiver shall be designed for a sequenced mating as follows: First mate: Ground contacts. Second mate: Power contacts. Third mate: Signal contacts The SFP MSA specification for a typical contact pad plating for the PCB is 0.38 micrometers minimum hard gold over 1.27 micrometers minimum thick nickel. To ensure the long term reliability performance after a minimum of 50 insertion removal cycles, the contact plating of the transceiver is 0.762 micron (30 micro-inches) over 3.81 micron (150 micro-inches) of Ni on Cu contact pads. RJ45 Connector RJ45 connector shall support shielded and unshielded cables. Also, the connector is mechanically robust enough and designed to prevent loss of link, when the cable is positioned or moves in different angles. The connector shall pass the wiggle RJ45 connector operational stress test. During the test, after the cable is plugged in, the cable is moved in circle to cover all 360 deg in the vertical plane, while the data traffic is on. There shall be no link or data loss. Page 10 of 10