Installation Guide. Overview

Similar documents
Installation Guide. Overview

Installation Guide Hoops (IHS) Cable

Shipping/Receiving The internal framework and fabric components may arrive in different shipments.

Shipping/Receiving The internal framework and fabric components may arrive in different shipments.

C-Series. Fabric Diffuser. Installation Guide. 30 Angle Diffusion. Flat Diffusion COMPONENT DETAILS...3 INSTALLATION

Q-Sox Installation Instructions

MOTORIZED STANDARD SHADE WITH CABLES Installation Instructions

RAMPAGE P R O D U C T S. INSTALLATION INSTRUCTIONS BRONCO ZIPPER FASTRACK TOP PART #984xx BRONCO TOOLS REQUIRED

Hatchback Wing Riser Kit

ClearSpan Hydroponic Table Kit

2-Door EXO-Top Roof Rack System

GrowSpan Series 500 Roll-Up Ends

Mount to the Wall INSTALLATION MANUAL

ClearSpan End Frame Kit 30' Wide x 11' High

ClearSpan PolyMax Windbreak Wall

southpaw enterprises, inc.

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

STOP! READ THIS FIRST

Installing A Carver Bimini Top

WeatherShield Covered Walkway and Connect-A-Building

RAMPAGE P R O D U C T S. BRONCO ZIPPER FASTRACK TOP PART #984xx BRONCO TOOLS REQUIRED

ClearSpan Round Style Mini Garage

Moo-Tel Calf Hutch CLEARSPAN ANIMAL HOUSING W x 12 L W x 18 L W x 24 L

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

ClearSpan End Frame Kit 26' Wide x 12' High

ClearSpan PolyMax Windbreak Wall

Be sure any accessory used will fit with the soft upper doors before installing. Not all accessories will be compatible.

Baby Grande or Grande Crank Shade with Cables and Housing Installation Instructions

INSTALLATION TORSION SPRING FRONT OR REAR MOUNT LOW HEADROOM. 1 Cutting Vertical Track. 2 Fully Adjustable Jamb Brackets

ASSEMBLY INSTRUCTIONS

Technicians of Terror. This is the air valve we make to use with our air

WeatherShield Daddy Long Legs Canopy

Castle Frame Assembly Table AT-8. Diagnostics Manual. Castle, Inc. Petaluma, CA

TEXTILE DIFFUSER MOUNTING INSTRUCTION

1. Layout. Step 1. Step 2. Step 3. Fig. 1

Tools Needed Hardware Provided (per shade) Hardware Needed

Assembly Guide for Series 500 Ridge Vent Kits

TYGER GUARD. Parts List BEFORE INSTALLATION WARNING TG-GD6D /7. Tyger Guard. Tube Brackets (Bull Bar) passenger or driver side

C L A S S I C. Deluxe. Snow Thrower Cab. Assembly and Care Instructions

GroundControl. Follow instructions contained in this manual. Incorrect installation could result in serious injury or damage to property.

6' Wide Premium Greenhouse Benches

STANDARD GRAVITY BOX TARP INSTALLATION

INSTALLATION INSTRUCTIONS DODGE RAM 2 & 4WD 1500 PART # P5058

STOP! READ THIS FIRST

INSTALLATION INSTRUCTIONS GRILLE GUARD RAM 1500 PART # 5058/5058-2

Installing A Carver Bimini Top

TorqueMaster Replacement Spring

LEANER SETUP MANUAL PATENTED SINGLE AUGER

Work Space Set-up. Slats will level the pipe during bending and help minimize twisting of the bow.

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

Palladian/ Keystone Models 202/204 Maintenance Kit

MSP-WRTIDSKY1 Light Weight Suspended Ceiling Kit for use with Island Display Skybox

INSTALLATION INSTRUCTIONS

Rollerscreen ENG. Installation Instructions

ClearSpan SolarGuard Round Style Storage Building

Motorized or Crank Operated Fortress Zipper Track Shade with Housing and Side Track Installation Instructions

6' Wide Premium Greenhouse Benches

INSTALLATION INSTRUCTIONS HEAVY DUTY TILT WALL MOUNT Model: PPH-2000

Diva Acoustical Ceiling

ClearSpan Mini Grab Bag Shelters

STRAIGHT HANDLEBAR KIT

Installation Instructions Standalone or continuous run configurations - 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS

Installing A Carver Bimini Top

Before beginning refer to page 4 to assure that all parts are included in your kit. Refer to diagrams for help when installing top and hardware.

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.

4-Door EXO-Top Roof Rack System

WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. WARNING. Ranger XP Door Kit

TRAILMATE METEOR ASSEMBLY MANUAL

50 W ide. Future Trac G able E nd. Installation Instructions AIGE

ASSEMBLY INSTRUCTIONS

southpaw enterprises, inc.

Video Wall Installation Instructions 2W X 3H, 3W X 3H

CABANA / PAVILION ASSEMBLY ALUMINUM FRAME MODELS

INSTALLATION INSTRUCTIONS Scout II - Fast Trac PART #

INSTALLATION INSTRUCTIONS CJ-5 M38A PART # With Doors

STENCIL MACHINE OPERATION uline.com H-259, H-347 H-408 CUTTING THE OIL BOARD INSERTING THE OIL BOARD

Gared Pro-S Portable Backstop

EP-60 END OF CAR JUNCTION BOX KIT and ASSEMBLY AND INSTALLATION INSTRUCTIONS

Formulate Designer Series 20 Backwall - Kit 07

Heavy Duty Ceiling Tilt Mount Installation Manual

ClearSpan Majestic Greenhouse Film Roof with Roll-up Sides

Nancy s Knit Knacks LLC 4 Yard Option Upgrade Kit Assembly Instructions and User Manual

Q-Zone Hoop-Frame. Assembly Instructions. Copyright July 11, 2018 Grace Company (Reproduction Prohibited) Version 1.8

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

Breathable Wall Light Traps & Blackout Fan & Shutter Kits

INSTALLATION INSTRUCTIONS

HOUSE PARTS PACKED IN HOUSE BOX PARTS IN PLASTIC BAG (HARDWARE) PARTS IN SMALL PLASTIC BAG (FLOOR CLIPS) PARTS PACKED IN BUNDLE

Operating, Servicing, and Safety Manual Model # 100 Standard Hydraulic Tubing Notcher Model #100-U Heavy Duty Hydraulic Tubing Notcher

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

Rayport G Eco Dealer Kit

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Flex Fence Instruction Manual

13401 Brooks Drive Baldwin Park, CA p f shademakerusa.com

mila-wall (Series100) General Operating Instructions page 1 of 15

General Prisoner Transport Install Instructions PT-2-INST

EZ-Grow Professional Greenhouse Bench

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

- 2 JOINER ALIGNERS - 2 JOINING BRACKETS - 4 HEX BOLTS. Factory pre-installed mud flange TOOLS REQUIRED: Phillips screwdriver, 5/16 nut driver.

48 in. X 96 in. 500 Pound Capacity Motorized Overhead Storage Unit Installation Guide [OPTION B] MODEL # PRM4X8 Patent Pending

EZ-HAUL GARDEN CRATE WAGON

Transcription:

Installation Guide Thank you for selecting a DuctSox SkeleCore Pull-Tight with Cable System. This guide will be helpful for installing the system. The key to a successful SkeleCore Pull-Tight installation is using Tensioning Baskets to apply tension to the fabric and to smooth the appearance. Sections of fabric will be labeled, assembled, bagged, and boxed for shipping. Systems will include a drawing detail of the system identifying what is in each package and detailed dimensions of support locations. Overview Inventory Read through this guide thoroughly. Review the components that need to be assembled and installed. Review the Engineering and Architectural drawings of the project while reading this guide, including the project-specific drawing details provided by DuctSox. Shipping/Receiving In some cases the DuctSox support system is delivered to the job site ahead of the DuctSox fabric sections. Depending on the size of a project or order, a DuctSox System will be shipped by common courier in a single brown box or several boxes. Larger orders will be shipped in crates by a common freight courier. Each DuctSox length should be packaged into individual plastic bags and labeled according to size and number of pieces. Other markings or labeling may also be incorporated for larger or more complicated systems. Be sure you have determined all boxes are accounted for. Unpacking Inspect shipment carefully and make sure all components are accounted for by emptying packaging and examining all contents. Note any missing or damaged pieces listed on the Bill of Lading and contact your courier and DuctSox Representative. Labeling Each fabric section will have a tag near any zipper. The tag will include job number, ship date, diameter, section number (if the total length is comprised of more than one fabric section), and total length. Equipment Required: Drill Level Tape measure Marker or pencil Wrenches for cable clamps and eye bolts (5/16 and 9/16 ) Flat (standard) screwdriver Cable cutter Rivet gun Installation Guide: SkeleCore Pull-Tight with Cable 1

Component Details Tension Cable Lock Universal Ring (UR): Used at both ends of each basket. Available in diameters from 8 to 60 (2 increments) or 203mm to 1524mm (51mm increments). UR Connector Tensioning Basket Tensioning Basket Tube with Push Button: 28.5 (724mm) in length to provide 30 (762mm) of spacing between rings. End of tube with push button is shown. 2 Installation Guide: SkeleCore Pull-Tight with Cable

Hoops: Used at 5 (1524mm) intervals in the interior of each tensioned section. Available in diameters from 8 to 60 (2 increments) or 203mm to 1524mm (51mm increments). Hoops are factory installed. Top Zipper Tension Clips Top Zipper Cable Intermediate Support 1/8 (3mm) Cable Only Glider Attachment Type 1 Kit Installation Guide: SkeleCore Pull-Tight with Cable 3

Installation Steps 1. Review materials in box, including the CAD drawing and installed location of the DuctSox 2. Prepare metal inlet collar for fabric connection 3. Mark placement and install cable 4. Install Pull-Tight components and fabric 5. Start up AHU 6. Balance airflow Step 1 Review materials in box, including the project-specific drawing and installed location of the DuctSox. The Project-Specific Drawings detail the specific locations of Tensioning Baskets and Cable Stops using the Inlet Belt as the main reference point. READ INSTRUCTIONS THOROUGHLY BEFORE BEGINNING. Example Project-Specific Drawing Detail Step 2 Prepare metal inlet collar for fabric connection. Confirm inlet air supply location. Confirm inlet air supply size. DuctSox inlets are manufactured 1/2 (12mm) larger than specified to fit over metal inlet collar. Metal collar length should be 6 10 (150 to 250cm) for secure fabric attachment. Metal Inlet Collar 6 10 (150 250cm) Edge Guard (Supplied) Edge Guard (provided) should be installed on the edge of the metal collar to reduce fabric wear from the metal edge. 4 Installation Guide: SkeleCore Pull-Tight with Cable

Step 3 Mark Placement and Install Cable. Step 3 1 Row Style The following details are used for ALL styles. Type 1 and Type 2 Kits Type 1 and Type 2 kits are for straight runs of cable: Type 1: 50 feet (15250mm) or less Type 2: 50 to 100 feet (15250mm to 30500mm) For systems over 100 feet (30500mm), a combination of the kits should be used. These kits include one 6 (153mm) turnbuckle (two for Type 2), two eyebolts, two cable thimbles, and four cable clamps. Eye bolts must be fastened into the structure of the building by others (this could include knee braces). Cable is fastened directly to an eyebolt with a thimble and two cable clamps. Take the cable end and thread two cable clamps onto it. Now hook the thimble onto the eyebolt. Next, thread the cable onto the thimble and through the eyebolts (cable clamps are still on the cable). Now thread the cable back into the cable clamps and tighten them. Cable is then fastened directly to the turnbuckle with a thimble and two cable clamps. Slack in the cable is taken up by the turnbuckle. If cable is still too loose after tightening the turnbuckle, loosen the cable, re-fasten cable to turnbuckle at a tighter position, and re-tighten the turnbuckle. Do not over-tighten the turnbuckle, we recommend no more than 100 lbs (445 Newtons) of tensile force. Intermediate Support Cable Installed every 12.5 feet (3810mm) or less to keep the DuctSox installed at a consistent elevation (reduces sag of the cable). Standard Installation Guide: SkeleCore Pull-Tight with Cable 5

Step 3 Determine placement of cable (both cable path and elevation). The cable must be mounted 1.5 (38mm) above the 12:00 location of the DuctSox. Intermediate Cable supports are spaced no more than 12.5ft (3810mm). 1.5 (38mm) T s There should be roughly 12 (305mm) from sidewall of DuctSox to the closest edge of any knee-bracing. Structure too close to the main run may cause premature failure due to abrasion from the structure. NOTE: Offset distance of branch knee-brace from main trunk is approximately half of the main trunk diameter plus 12 (305mm). 12 (305mm) 12 (305mm) Elbows Extended straps on heels of elbows are provided for support to cable suspension (Figure A). Vertical elbows are also supported by extended straps (Figure B). Figure A Figure B 6 Installation Guide: SkeleCore Pull-Tight with Cable

STEP 4 Install Tensioning Baskets and Fabric. Tensioned Sections must be completed in succession moving away from the Inlet Belt. Overview of Step 4: A. Install fabric Inlet Belt onto metal collar B. Install Tensioning Basket C. Using Project-Specific Drawing, install the balance of Tensioning Baskets and fabric. D. Tension fabric E. Fitting considerations A. Install fabric Inlet Belt onto metal collar. DuctSox Inlet must be attached to the metal collar using screws (not included) through plastic patches on the Inlet Belt. Be sure to locate the zipper start and seam at the 12:00 orientation for proper alignment. B. Install first section of DuctSox fabric and Tensioning Basket at Inlet Belt. Rivet the UR Connector to the Universal Ring. This assembly may already be completed for you by DuctSox factory. Rivet the Tension Cable Lock to 12:00 of the Universal Ring (2x). Each one in opposite directions. Inlet Patch Tension Cable Lock Levers NOTE: When the Tensioning Basket is assembled, the UR Connectors point towards each other. The Tension Cable Lock Levers point in the same direction towards the fabric section being tensioned (see drawing on page 8 for clarification). WARNING: If this is done incorrectly, the system WILL NOT TENSION. Install the Universal Ring assembly on the cable (2x). (Through the fabric and zipper where required.) The lever of the Cable Lock will point towards the section being tensioned. UR Connectors Finish the basket by connecting the two Universal Ring assemblies with the basket tube. Install Universal Ring Assembly on Cable Top zipper, open Installation Guide: SkeleCore Pull-Tight with Cable Finish Basket with UR Connector 7

C. Using Project-Specific Drawings, identify placement of the balance of SkeleCore Pull-Tight Tensioning Baskets. Tensioned Sections are defined as the areas between the Tensioned Baskets. IMPORTANT: Tension Cable Lock Levers point TOWARDS the Tensioned Section. Tension Cable Lock Levers point TOWARDS the Tensioned Section. Tension Cable Lock Levers point TOWARDS the Tensioned Section. 47 (14.3m) Total Example Length 0 40 (12.2m) 47 (14.3m) Tensioned Section Tensioned Section Twist and snap the Glider attachments of the DuctSox onto the cable (pliers may be helpful for installation and removal of Gliders). Unzip fittings and slide them in place independently of the straight sections. Tensioning Baskets are installed at the Inlet, Endcap, Elbows, Reducers, and intermediate points of longer sections. BE SURE TO REVIEW THE PROJECT-SPECIFIC DRAWINGS FOR ALL EXACT LOCATIONS. The Cable Stop is used to keep shorter sections of DuctSox under slight tension. Nuts are tightened to lock the stop at locations where Gliders are to be locked in place (see Step 5). Locations of Cable Stops (if any) can found on the project-specific drawings. 8 Installation Guide: SkeleCore Pull-Tight with Cable

Attach the Tension Clips of the fabric to the Tensioning Basket. Complete the connection by zippering the duct to the Inlet Belt. To complete the first Tensioned Section, repeat the process going in the other direction, after you zipper the two sections of fabric together. Tension Clips in System Top Zipper, Open Top Zipper, Closed D. Tension Fabric. The amount of take-up will vary based on the length of the Tensioned Section. As tension is applied, wiggle your DuctSox to evenly distribute fabric tensioning over entire length. Tension the fabric until the desired roundness and tautness of the fabric is achieved. NOTE: Make sure the lock lever is engaged prior to pulling back on basket. Pull back on Tensioning Basket Lever Engaged INCORRECT Before Tensioning After Tensioning Installation Guide: SkeleCore Pull-Tight with Cable 9

If your section ends with an Endcap, follow these additional instructions. IMPORTANT: Before installing the Endcap, insert a Hoop into the mesh flap of the Endcap. Tuck the Hoop under the mesh. Cinch the rope tight and lock. Hoop Endcap Take the Endcap and install it on the corresponding Tensioning Basket. 10 Installation Guide: SkeleCore Pull-Tight with Cable

E-1. Fitting Considerations: Reducer or Elbow. Fitting is placed between two Tensioned Sections. 1. Reference the drawing to determine important dimensions for installation of Fitting Tensioning Baskets. 2. Install and tension the DuctSox section prior to (up stream) of the Fitting. 3. Measure and place the downstream Tensioning Basket. 4. Zip fabric fitting in place after adjacent Tensioning Baskets are secured. Reducer Illustrated View Tensioning Basket E-2. Fitting Considerations: Take-Offs. 1. The main section of a Take-Off is tensioned in-line with the sections before and after this fitting. The section before a Take-Off, the Take-Off, and the section after a Take-Off are one continuous tensioned section. 2. Install the Tensioning Basket at the branch of the Take-Off fitting just as the Tensioning Basket at the Inlet was installed. 3. Please refer to the project-specific drawings for basket locations. E-3. Fitting Considerations: Fitting-to-Fitting Connection Fitting-to-fitting connections will be detailed on the Project-Specific Drawings. Use these details for this installation. Step 5 Start Up AHU. Turn on the AHU and inflate the DuctSox System. Check Top Zippers and sections to ensure system is inflating properly. If lengths do not fit properly, double check all field measurements and compare to drawings. If all measurements are correct, contact your DuctSox Representative to discuss options. Failure to install DuctSox Systems correctly may void warranty. Installation Guide: SkeleCore Pull-Tight with Cable 11

Step 6 Air Balancing. System must be balanced to design CFM and static pressure immediately after installation. A zipper at the inlet location provides easy access to monitor airflow. If the fabric is fluttering after balancing, please contact your DuctSox Representative immediately. Solutions to the fluttering include adjusting the Adjustable Flow Device (AFD), adding AFDs, or other solutions that would result in a less turbulent airflow. Laundering Instructions Sedona-Xm, TufTex, Verona, DuraTex, Microbe-X, Rx, and Stat-X fabrics: Remove the DuctSox fabric from your system, being sure to unzip all sections. Take care in recording where each section was installed. Remove the hoops from the DuctSox system by simply twisting the attachment sideways. Note: the hoop attachment only slides one way. Turn soiled side out and soak in cold water for 30 minutes. Wash cold in gentle cycle. Rinse thoroughly (repeat cycle if rinse water is dirty or DuctSox are still soiled). Drip dry or no-heat tumble dry.?if any questions arise regarding the installation of your SkeleCore Pull-Tight with Cable, contact us. 866-382-8769 or 563-588-5300 9866 Kapp Court Peosta, IA 52068 Ph: 866-382-8769 or 563-588-5300 Fax: 563-588-5330 www.ductsox.com 2014 DuctSox Corp. DSSKELPTCBLIG0714C