DUK. Compact Ultrasonic Flowmeter

Similar documents
DUK COMPACT ULTRASONIC FLOWMETER

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

DVZ COMPACT VORTEX FLOWMETER

Electromagnetic flowmeter in all metal design Model MIM

NGR. Guided Wave Radar Level Transmitter

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

Full Metal Variable Area Flowmeter and Counter Model BGF

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

Liquid Level Switches

Frame through-beam sensors

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

LTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p

KDS. All Metal Variable Area Flowmeter. for Liquids and Gases

BGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Through-beam ring sensors

Magnetic Inductive Flowmeter

Coriolis Mass Flow Meter Model TM

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

Level Sensors Reed Contact Chain

Coriolis Massflowmeter

Electronic Flow Monitor

NBK-04. Level Indicator for Tank-Top Mounting

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

INLINE flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Temperature Transmitters

DUC. Ultrasonic Flowmeter for Liquids. Portable or Stationary

INLINE flowmeter for continuous flow measurement

RCM DIRECT READING FLOWMETER

The compact test- disconnect terminal interface system for protection and secondary technology

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA,

Digital flow transmitter for continuous flow measurement

Valve Island with Electronic I/O

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

COMPACT-LINE. Transmitter for ph-value

Digital flowmeter for continuous flow measurement

Magnetic Inductive Flow Sensors VMI Series

Magnetic Inductive Flow Sensors induq. Series VMI

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Digital batch controller

Digital flowmeter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement

ph or ORP Transmitter

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Electronic Temperature Transmitters

Ultrasonic level transmitter, non-contact

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Electromagnetic Flow Transmitter

Process Control HPP-25

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Catalogue NE 0506 FIXTURING SYSTEM. Modular Zero-Point Fixturing for Pallets, Workpieces and Fixtures

OVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C

Insertion Thermocouples with Bayonet Lock

Digital flow ELEMENT transmitter for continuous flow measurement

Inclinometer Selection Guide

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

FLOMID FX Electromagnetic Flowmeter

Digital inductive conductivity transmitter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids

2-channel speed sensor GEL 247 Compact sensor for harsh applications

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Digital conductivity transmitter

Electromagnetic flowmeters and switches DWM 1000/2000

Process-Controller HPP-25

SUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20

EXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X

Conductivity Transmitter

ED701 General Industry Pressure Transmitter

ABB Oy, KPM. Sakeusmittaukset paperikoneen massanvalmistuksessa

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

PAD - Heavy Duty Differential Pressure Trasmitter

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

Pressure transmitter for general industrial applications Model A-10

COMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

The transducer component converts the measured signal and displays the actual value.

MICROFUSION SINGLE PHASE SCR POWER CONTROLLERS

Table of Contents Executive Summary 29

LENORD. +BAUER... automates motion. Magnetic absolute rotary encoder GEL 2037 with heavy duty flange or tooth wheel adapter

NAT Applications. Features

Target disk flowmeter for liquids and gases

FLOWave SAW-Flowmeter

Transcription:

Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F Connections: ½"...3" NPT or G Thread Material: Brass or 36 Stainless Steel Outputs: Analog, Frequency, Switching, Compact Electronics with Digital Displays, Batching and Totalizing Electronics 0/07-04 KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECH REPUBLIC, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM KOBOLD Instruments, Inc. 80 Parkway View Drive Pittsburgh, PA 0 Main Office:.800.998.00.4.788.4890 info@koboldusa.com

Description The KOBOLD model DUK fl ow meters are used for measuring, monitoring, metering, and batching of low viscosity liquids. They are highly repeatable, feature a small pressure loss, and offer measurement independent of density and temperature changes. The devices work on the principle of run time difference. Ultrasonic waves in the media are infl uenced by the rate of fl ow. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of the ultrasonic signals. If there is no fl ow, the run times of both signals are identical. If the media is fl owing, then the run time of the signal against the fl ow is longer than the signal with fl ow. The run time difference, which is determined by a microprocessor, is proportional to the rate of fl ow. The devices can be equipped with a switching, a frequency, or an analog. In addition, a compact electronic can be selected that features a digital display, a switching, and an analog. The device series is rounded off by an optionally available batching or totalizing electronic. The meter electronic indicates the momentary fl ow rate in the fi rst line of the display and the partial or total fl ow in the second line. A batching electronic controls simple fi lling tasks and similarly measures fl ow rates, total amounts, and fi lling amounts. The analog and two relay s can be used for further processing of the signals. Common applications include: machine building, automotive, robotics, cooling, and hot water. T V m C L Electronic T Technical Details Measuring Principle: Range: Media: Viscosity: Accuracy: Repeatability: Mounting Position: Straight Piping: Ultrasonic See Table Liquids with Max. % Solid Max. 3 cst ±0.7% of Reading + ±0.7% of F.S. ±0.% of F.S. Universal: Flow in Direction of the Arrow (Horizontal: Electronic on Top or Below) 0 x Pipe Diameter In/Out Media Temperature: 4...94 F - 4...48 F (High Temp Version) Ambient Temperature: 4...8 F Response Time: Approx. 0... s (Depending on Electronic Version) Max Pressure: 30 PSI Pressure Loss: Max.. PSI at F.S. Protection: IP 6 Wetted Parts Sensor Housing: Brass or 36 Stainless Steel Sensors: PEEK Seal: NBR for Standard Version FKM for High Temp Version (Others upon Request) Measuring Ranges and Weights Model Measuring Range "G" (GPM) Measuring Range "H" (LPM) Size (NPT/G) DUK-...S30x DUK- F3x0 DUK-...Lx43 DUK-...C3xx DUK-...Ex4R DUK-...Gx4R DUK with ADI 4 V DC DUK with ADI 30 / V AC DUK-xxx4 0.0... 0.08...0 ½.87 LB.3 LB.0 LB 4.74 LB.9 LB DUK-xxx 0.04...0 0.6...40 ¾.3 LB.76 LB.6 LB.8 LB 6.39 LB DUK-xxx6 0.06...6 0...63 3.0 LB 3.64 LB 3.3 LB 6.06 LB 7.8 LB DUK-xxx8 0.6...40 0.6...0 ½.8 LB.6 LB. LB 8.0 LB 9.6 LB DUK-xxx9 0...6...0 8.38 LB 8.8 LB 8.7 LB.4 LB.46 LB DUK-xxxB 0.6...60...630 3.6 LB 6.09 LB.98 LB 8. LB 9.73 LB

Electrical Specifications DUK-..S300, DUK-..S30D (Switching Output) Bi-color LED for Switch Status Switching Output (..S300): SPDT Relay, max. A / 30 V DC Switching Output (..S30D): Active 4 V DC, N/C and N/O Switch Point: 0...90 % of f.s. in 0 % Steps, Confi gurable by the Customer Using a Rotary Switch ± 0 % Power Consumption: 30 ma Electrical Connection: Plug M x Max Range Overflow: Flashing Bi-color LED from 0% of full scale DUK-..F300, DUK-..F390 (Frequency Output) Pulse Output: PNP, Open Collector, max. 00 ma Frequency at F.S.: 00 Hz (..F300) 0 to 000 Hz (..F390) User Specifi ed ± 0 % Power Consumption: ma Electrical Connection: Plug M x Max Range Overflow: Frequency approx k from 0% of full scale DUK-..L343 (Analog Output) Analog Output: 4-0 ma, 3-wire Max. 00 Ω ± 0 % Power Consumption: Max. 4 ma Electrical Connection: Plug M x DUK-..Ex4R (Totalizing Electronic) LCD, x 8 Digits, Illuminated Rate, Total and Grand Total, Units Selectable Analog Output: 4-0 ma Adjustable Max. 00 Ω Switching Output: Relay (x), Max. 30 V/ A, 60 VA Via 4 Buttons Functions: Reset, MIN/MAX Memory, Flow Rate, Total and Grand Total, Language ± 0 %, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable Connection or Mx Plug DUK-..Gx4R (Batching Electronic) LCD, x 8 Digits, Illuminated Batching, Total and Grand Total, Units Selectable Analog Output: 4-0 ma, Adjustable Max. 00 Ω Switching Output: Relay (x), Max. 30 V / A, 60 VA Via 4 Buttons Functions: Batching (Relay S), Start, Stop, Reset, Fine Batching, Correction Amount, Flow Switch, Total Quantity, Language ± 0 %, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable Connection or M Plug DUK-..L443 (Analog Output) Output: 4-0 ma, 3-wire Max. 00 Ω ± 0 % Power Consumption: Max. 4 ma Electrical Connection: Plug DIN 4360 DUK-..C3xx (Compact Electronic) 3-digit LED Analog Output: 4-0 ma Adjustable (only DUK-..C34x) Max. 00 Ω Switching Output: (x) Semiconductor PNP or NPN Contact Function: N/C-N/O-Frequency Programmable (Approx. 400 Hz at F.S., Uncalibrated) Via Buttons ± 0 % Power Consumption: Approx. 00 ma Electrical Connection: Plug M x DUK-..Kxx (ADI- Electronic) Bar Graph and -Digit Digital Combination Display; Batch System Analog Output: 4-0 ma, 0-0 V Switching Output: x Relays / SPDT Max. 0 V AC, A Resistive Load Max. 30 V DC / A Via 4 Buttons Power Supply: 00-40 V AC, ±0% or 8-30 V AC /0-40 V DC Electrical Connection: Terminal Block via Cable Gland 3

Order Details (Example: DUK- N4 G S300 L) Note: Flow range determined by fi tting size and can be referenced on the measuring range and weight table located on page Model / Housing Material Connection* Output / Electronic Flow Direction Switching Output..S300.. = Relay, M-Plug..S30D.. = Active 4 V, M-Plug DC Frequency Output..F300.. = M-Plug, 00 Hz..F390.. = M-Plug, 0 to 000 Hz (User Specifi ed)..n4g.. = ½" NPT Analog Output..NG.. = ¾" NPT..L343.. = M-Plug, 4-0 ma..n6g.. = " NPT..L443.. = DIN-Plug, 4-0 ma..l = from Left to DUK-.. = Brass..N8G.. = ½" NPT Right Compact Electronic DUK-.. = SS..N9G.. = " NPT..C30R.. = Open Collector, PNP (x)..r = from Right to..nbg.. = 3" NPT..C30M.. = Open Collector, NPN (x) DUK-.. = High Left..C34P.. = 0 ma, Open Collector, PNP Temp...G4G.. = G ½ Brass..C34N.. = 4-0 ma, Open Collector, NPN..GG.. = G ¾..T = from Top to ADI Electronic Bottom DUK-.. = High..G6G.. = G Temp. Display Power Supply Output Contacts SS..G8G.. = G ½..B = from Bottom to K = Bar Graph/ 0 = 00-30 V 0 = without AC/DC..G9G.. = G = (x) Relay Top digital 3 = 8-30 V 4 = 4-0 ma, AC..GBG.. = G 3 SPDT display 0-40 V 0-0 VDC Totalizing Electronic..E4R.. = LCD, 4-0 ma, Relay (x), m Cable..E34R.. = LCD, 4-0 ma, Relay (x), M-Plug (x) Batching Electronic..G4R.. = LCD, 4-0 ma, Relay (x), m Cable..G34R.. = LCD, 4-0 ma, Relay (x), M-Plug (x) DC Accessories: P/N 807.037 = 4-Pin Micro-DC Connector with 6-foot Cable for Output Types F300, F390, L 343, & S30D P/N 807.007 = -Pin Micro-DC Connector with 6-foot Cable for Output Types C3xx, S300, E34R, & G34R P/N 807.087 = 8-Pin Micro-DC Connector with 6-foot Cable for Output Types E34R & G34R *Standard display in G/min, optional display L/min (code H instead of G) Dimensions DUK-Sensor Model G/NPT SW H L B DUK-xxx4 ½.8.4 4.49 ca..83 DUK-xxx ¾.4..98 ca..99 DUK-xxx6.8.48.7 ca. 3. DUK-xxx8 ½.36.7 7.48 ca. 3.4 DUK-xxx9.99.9 9.37 ca. 3.8 DUK-xxxB.3 3.3.0 ca. 4.80 4

Dimensions (mm) DUK-..S30x, DUK-..F3x0, DUK-..L343 DUK-..L443 8 Mx 60 34. 34 7. 8 60 7. DUK-..C3xx DUK-..Ex4R, DUK-..Gx4R Ø44. 48 90 34 7 8. Mx ca. 6. 60 DUK with ADI Electronic

Electrical Connection DUK-..S300 DUK-..S30D N/O common N/C N/C N/O DUK-..F3x0, DUK-..L343 DUK-..L443 n.c. signal out 3 signal out +V S DUK-..C30* DUK-..C34* switch out 0(4)-0 ma switch out switch out DUK-...E4R, DUK-...G4R Cable Connection DUK-..E34R, DUK-..G34R Plug Connection Wire Number DUK-..E4R Totalizing Electronic DUK-..G4R Batching Electronic 4 V DC 4 V DC -0 ma 4-0 ma 4 Reset Total Part Control * 6 n. c. Control * 7 Relay S Relay S 8 Relay S Relay S 9 Relay S Relay S 0 Relay S Relay S * Control <-> : Start-Batching Control <-> : Stop-Batching Control <-> Control <-> : Reset-Batching +4 V DC reset/ctr * U 4 3 d.c./ctr * 30 V AC/DC / A U S 7 8 3 6 4 0 (4) - 0 ma out max. 00 Ω S 6