Two-channel safety barriers Series 9002

Similar documents
Two-channel safety barriers Series 9002

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Binary Output without Power Supply Series 9176

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Isolators A3/1. Vibration Transducer Supply Unit Series

Binary Output Series 9175

Digital Input Output Module for Zone 2 Series 9470/33

Analog Universal Module HART for Zone 2 Series 9468/33

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Output Module for Zone 1 Series 9470/32

Isolating Repeater Input Series 9163

Isolators A3/1.

Temperature Input Module for Zone 1 Series 9482/32

Fieldbus Isolating Repeater Series 9185/11

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital I/O Coupler (4-wire) Series 9413/21

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Safety Barriers 2/1. Hazardous area. 250 V max I.S.

Remote I/O. 74 Remote I/O. Remote I/O System

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Signal Beacon - LED Series 6162

Control Unit Series 8208

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Temperature Measurement

Power supply. Calibration. Surface finishing. Seal. Process connection

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Actuators Series 8602/3

Rail mounted Temperature Transmitter TH102/TH102-Ex

Technical Data. General specifications. Rated operating distance s n 3 mm

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Motor Protection Circuit Breaker Series 8146/5-V27

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

SINEAX TI 807 Passive DC signal isolator

SITRANS T measuring instruments for temperature

Technical Information Barrier RB223

Pressure transmitter AKS 32 and AKS 33

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

Assembly. Front view. Parametrization interface. Power Bus

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter

OPTITEMP TT 10 C/R Technical Datasheet

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

MACX MCR-EX-SL-RPSSI-I

SINEAX B 811 Power Pack with additional Functions

TTH200 Head-mount temperature transmitter

2002 IS Catalog. Page

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

Rosemount 648 Wireless Temperature Transmitter

PRetrans Table of contents

Certificate of Compliance

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MINI MCR-SL-UI-I-LP-NC

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

IP26 Series Current to Pneumatic Converter

NEW. Datasheet. ACT20M Signal Isolation and Conversion

onlinecomponents.com

SITRANS T measuring instruments for temperature

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

RMA42. Technical Information

Temperature Transmitter itemp RTD DIN rail TMT 127

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Field indicator for current loops with HART communication Models DIH50, DIH52

Signal conditioner - MACX MCR-UI-UI-NC

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

FC Series Signal Conditioners

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

Field indicator for current loops with HART communication Models DIH50, DIH52

Temperature Measurement

Temperature Measurement Transmitters for mounting in sensor head

Coupling Relays and Converters

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Transcription:

Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation thanks to simultaneous snap-on mounting on rails and connection to PE and earth > Reduced stock-keeping thanks to a uniform back-up fuse www.stahl.de Series 00 040E00 The R. STAHL INTRINSPAK safety s of Series 00 can be used for various tasks in the field of automation. The wide product range and scope of different combinations offer you a large field of applications. The safety s allow the intrinsically safe operation of HART transmitters, proximity sensors, potential-free contacts, temperature sensors, DMS, solenoid valves, indicators and others. Due to the compact width, space-saving and flexible installation in the switch cabinet is possible. Thanks to DIN-rail mounting and simultaneous connection of the equipotential bonding, the installation can be performed very easily. ATEX / IECEX NEC 5 NEC 6 NEC 0 Class I Class I Class II Class III Zone 0 0 Zone 0 0 Division Ex i interface x x x x x x Ex i interface Ex i interface x x x x x x Installation in x x Installation in x x Installation in x x x WebCode 05-03- AK00 III en 00A Safety s /

Two-channel safety s Series 00 Explosion Protection Global (IECEx) Gas and dust IECEx PTB 08.0057X Ex na [ia Ga] T4 Gc [Ex ia Da] I Europe (ATEX) Gas and dust PTB 0 ATEX 053 X E II 3 () G Ex na [ia Ga] / T4 Gc E II () D [Ex ia Da] I Certificates Certificates Further parameters Installation Further information Technical Data Electrical data Transmission characteristic Leakage current at Temperature influence Transmission frequency In case of resistive current limiting I m ( ma I m ) ma In case of electronic current limiting IECEx, ATEX, Brasil (INMETRO), Canada (CSA), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (TR) in Zone, Division and in safe area see respective certificate and operating instructions ( ma (unless specified otherwise) ( 0.5 % / 0 K ( khz ( 00 khz ( 0 khz Ambient conditions Ambient temperature -0... +60 C Storage temperature -0... +75 C Maximum relative 5 % on average, no condensation humidity Mechanical data Degree of protection according to IEC 605 Terminal support IP0 Enclosure IP40 Enclosure material polyamide 6GF Connection type 4 connection terminals (cage terminals), each maximum.5 mm finely stranded / solid wire PA-terminals, each maximum 4 mm finely stranded / solid Weight approx 0.5 kg / Safety s 05-03- AK00 III en

Two-channel safety s Series 00 Version Description Type series Page Dual-channel s Connection to regulated power supply 00/ /4 Application for 3-wire NPN, sensors with voltage output 00/ /6 Low nominal current Application for 4/0 ma transmitters with -5 V input in the wiper Incl. precision resistance of Ω 00/ /7 Connection to regulated power supply 00/00 /8 Application for load cells 00/0 / Channel for positive and negative potential in one module Connection of a resistance teletransmitter is possible High precision resistance of each channel, 0 Ω ±0. Low temperature influence of < ppm/k Connection to regulated power supply 00/ / Connection to regulated power supply 00/ /3 Function: 00/3 /4 Channel current supply Channel evaluation No safety-relevant output current I o for channel Connection to unregulated power supply on to channel Nominal current limited to 35 ma Function: 00/3 /6 Channel current supply Channel evaluation Connection to regulated power supply Function: 00/3 /8 Channel current supply Channel evaluation No safety-relevant output current I o for channel Nominal current limited to 40 ma at Ω load Connection to unregulated power supply on to channel Evaluation for direct current signals with max. output current I o 00/33 / Suitable for potential-free contacts and floating 4/0 ma signals Positive potential of both channels Evaluation for direct current signals with max. output current I o 00/34 /0 Application for passive signals of 4/0 ma (transmitter with 4 conductors or more) with insulated analog input on the control system Channel for positive and negative potential in one module Connection to regulated power supply Suitable for voltage signals 00/77 / 05-03- AK00 III en Safety s /3

Two-channel safety s, potential: + / + Series 00/ Series 00/ Two-channel safety s, potential: + / + Connection to regulated power supply Installation permitted in Division and Zone + U e + Ue + Ue + Ue 0580E0 Channel R min R max I max Safety data Order number U o I o P o V Ω Ω ma V ma mw mh mf mh mf + 043 043 56 56 7.7 7.7 4 40 40 70 40 40 63.4.4. 8 8 30 7. 00/-0-04-00 + + + + + + 0 0 0 6 6.5 7.5 5 5 5 6 45 45 53 53 43 43 3 46 3 3 3 5 5 5 78 78 576 576 358 463 358 358 358 68 *) max. leakage current I leak ( 0 ma 00 0 0 0 0 6 37 6 6 6 88 3.6 3 3.7 3.7 3.7... 6 0 6 8 8 8 8.6 8 3 3 360 4.5 4.5 5 5 30 87 5 38 3 3 86 8 80 6 040 6 70 00 75 75 570 60 8 6 6 300 630 430 0 0. 4 0.7 60 60 43 60 60 40.7 4 0.8. 0.6 00 0.7 0.7 0.7 0.67 0.3 0.3 0.3 0.0 0. 0.087 3.6.6.3 560 560 60 560 560 5.4 54 5. 3 3.8 4 5 0.56 6 00 5 5 5 4.8.4.4.4 0.77.4 0.67 0.55 6 0.6 00/-30-360-00 *) 00/-37-0-00 00/--030-00 00/-60-38-00 00/-80-86-00 00/-80-3-00 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity /4 Safety s 05-03- AK00 III en

Two-channel safety s, potential: + / + Series 00/ Application case Load cell (DMS) 3 Ω or 700 Ω 6 conductors + 6 V, field circuit unearthed 00/3--5-00 00/--030-00 00/--030-00 +6 V Operating data Operating voltage ( + 6 V Voltage for load cell and U L (at = + 6 V) electric line Current for load cell I L (at = + 6 V) Number of the load cells connected in parallel Safety data Maximum voltage U o =. V I o = 85 ma external inductance L o 0. mh external capacity C o 0.3 μf Maximum power P o =.4 W Application note 3 Ω 700 Ω U L (V) I ma (V) U L (V) I ma (V) 0.4 30. 7 8.3 47 0.4 30 3 6. 60.5 4 4 5. 67 8.3 47.8 mh.4 μf For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 55 ma, the maximum power to P o =.3 W. 3-wire NPN inputs (negative switching) of proximity switches, photocells and encoders 063E0 Supply 00/-80-86-00 V +4VDC +0 V NPN Discrete -wire output for solenoid valves, LEDs and signalling devices +4VDC 00/-80-86-00 +4VDC 0660E0 05-03- AK00 III en 06606E0 Safety s /5

Two-channel safety s, potential: + / + Series 00/ Two-channel safety s, potential: + / + + U e + Ue R L + Ue + Ue Application for 3-wire NPN, sensors with voltage output Low nominal current Installation permitted in Division and Zone 0583E0 Channel R min R max I max Safety data Order number U o I o P o + L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf 4 4 64 7 6 8 8 8 0 3 760 0 780.3 0.76 0.065 84 0.55 00/-80--00 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity Application case 3-wire NPN inputs (negative switching) of proximity switches, photocells and encoders Supply 00/-80--00 V +4 V DC 0 V NPN 0657E0 Application note With this all loop voltages must be checked to ensure correct function. /6 Safety s 05-03- AK00 III en

Two-channel safety s, potential: + / + Series 00/ Two-channel safety s, potential: + / + + U e + Ue Application for 4/0 ma transmitter with -5 V input in the wiper Incl. precision resistance of Ω Installation permitted in Division and Zone + Ue + Ue Channel R min R max I max Safety data Order number U o I o P o L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf + 5 6 3 5 358 68 6 88 8.6 8 8 80 6 630 430 0. 0.6 3.6 4 5 0.56 6 0.6 00/-80-3-0 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety 0584E0 U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity Application case -wire, 4/0 ma transmitters - standard and HART 4... 0 ma +4VDC 00/-80-3-0 V +... 5 V Input Application note This safety is used if the automation system only accepts signals from to 5 V. This contains a Ω resistor to convert the signal... 5 V. 33E0 05-03- AK00 III en Safety s /7

Two-channel safety s, potential: - / - Series 00/00 Series 00/00 Two-channel safety s, potential: - / - Connection to regulated power supply Installation permitted in Division and Zone -Ue -Ue -Ue -Ue 058E0 Channel R min R max I max Safety data Order number U o I o P o + + + L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf.5 7.5 5 5 043 043 3 46 3 3 56 56 358 463 358 358 7.7 7.7 6 37 6 6 6 0 6 8 8 8 4 87 5 38 3 3 86 40 40 70 540 45 785 6 6 300 40 40 63.7 4 0.8.4.4. 0.0 0. 0.087 8 8 30 5.4 54 5. 3 3.8 7. 0.77.4 0.67 0.55 00/00-0-04-00 00/00-60-38-00 00/00-80-86-00 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity Application case Vibration sensor Sensor Transducer 00/00-60-38-00 -4 V DC max. Input Operating data Operating voltage = - 4V Series resistance of the R = 358 Ω safety Safety data Maximum voltage U o = 6 V I o = 38 ma external inductance L o 0.8 mh external capacity C o 0.087 μf Maximum power P o = 8 mw Application note 5. mh 0.67 μf Application of the for Bentley Nevada and Metrix position transducer. This has negative potential; for a positive potential, use the 00/-60-38-00. 0665E0 /8 Safety s 05-03- AK00 III en

Two-channel safety s, potential: + / - Series 00/0 Series 00/0 Two-channel safety s, potential: + / - Application for load cells Channel for positive and negative potential in one module Installation permitted in Division and Zone -Ue -Ue Channel R min R max I max Safety data Order number U o I o P o 058E0 L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf + + 6 6 6 6 40 40 4 4 543 543 4 4.33.33 8.7.33.33 8.7 0 0 0 70 70 70 0 630 630 60 0 0 0 0.3 0.3 0.3 3. 3. 0.7 3. 3. 0.7 330 330 330....64.64 00/0-87-00-00 00/0-87-70-00 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity 05-03- AK00 III en Safety s /

Two-channel safety s, potential: + / - Series 00/0 Application case Load cell (DMS) 3 Ω or 700 Ω 6 conductors +/- 7.5 V (5 V), field circuit unearthed +7,5 V 00/0-87-70-00 -7,5 V 00/0-87-00-00 00/77-03-040-00 Operating data Operating voltage ( +/- 7.5 V (5 V) Voltage for load cell and U L (at ( +/- 7.5 V) electric line Current for load cell I L (at ( +/- 7.5 V) Number of the load cells 3 Ω 700 Ω connected in parallel U L (V) I ma (V) U L (V) I ma (V).6 35 3..6 55.6 35 3 8 70 0.6 45 4 7 80.6 55 Safety data Maximum voltage U o = 8.7 V I o = 330 ma external inductance L o 0.8 mh.45 mh external capacity C o 0.7 μf.64 μf Maximum power P o =.45 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 30 ma, the maximum power to P o =.36 W. 06E0 /0 Safety s 05-03- AK00 III en

Two-channel safety s, potential: ~ / ~ Series 00/ Series 00/ Two-channel safety s, potential: ~ / ~ +/-Ue +/-Ue +/-Ue +/-Ue Connection of a resistance teletransmitter is possible High precision resistance of each channel, 0 Ω ±0. Low temperature influence of < ppm/k Connection to regulated power supply Installation permitted in Division and Zone Channel R min R max I max Safety data Order number U o I o P o 05835E0 + L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf 0.7 0.7.4.. 0. 0. *) max. leakage current I leak ( 0 ma 33 33.6.6 3. 300 60 60 0.3.3 0. 00 00 00 7 7.8 000 000 000 00/-03-300- *) Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity 05-03- AK00 III en Safety s /

Two-channel safety s, potential: ~ / ~ Series 00/ Application case Pt00, -wire circuit, field circuit unearthed RTD Input T 00/-03-300- 05E0 Operating data Operating voltage Series resistance of the safety Measuring range Safety data Maximum voltage (.4 V R = x (0 Ω +/- 0. Ω) ( 400 C (I N ( 5 ma) ( 8 C (I N ( 3 ma) U o = 3. V I o = 300 ma external inductance L o 0. mh external capacity C o 00 μf Pt00, 3-wire circuit, field circuit unearthed.8 mh 000 μf RTD Input T 00/-03-300- 00/0-06-- Supply Voltage 060E0 Operating data Operating voltage Series resistance of the safety Measuring range Safety data Maximum voltage (.4 V R = x (0 Ω +/- 0. Ω) ( 400 C (I N ( 5 ma) ( 8 C (I N ( 3 ma) U o = 3. V I o = 4 ma external inductance L o 0. mh 0.5 mh external capacity C o 00 μf 000 μf / Safety s 05-03- AK00 III en

Two-channel safety s, potential: ~ / ~ Series 00/ Two-channel safety s, potential: ~ / ~ +/-Ue +/-Ue Connection to regulated power supply Installation permitted in Division and Zone +/-Ue +/-Ue Channel R min R max I max Safety data Order number + + + 05845E0 U o I o P o L o C o L o C o V Ω Ω ma V ma mw mh mf mh mf 5.5 5.5 8 8 84 84 043 043 58 58 5 5 56 56 77 77 57 57 7.7 7.7 7. 7. 5.8 4 4 00 00 00 4 80 80 60 8 8 35 40 40 80 40 40 480 4 4 0.5 40 40 4 6 6 0.7 8.8 8.8 0.478.4.4 0.5.4.4 0.5 Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety 5 5 4 8 8 45 4 5 5.88 0.3 0.3 00/-58-00-00 00/-40-04-00 00/-40-60-00 U o Maximum voltage L o max. permissible external inductance I o C o max. permissible external capacity Application case with RS 3 RS-3 Tx/Rx Tx/Rx Intrinsically Safe Field Device GND 00/-40-60-00 GND Interface Module 0664E0 05-03- AK00 III en Safety s /3

Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: + Function: Channel current supply Channel evaluation No safety-relevant output current I o for channel Nominal current limited to 40 ma at Ω load Connection to unregulated power supply on to channel Installation permitted in Division and Zone 0543E0 Channel R min R max I max ãu Safety data Order number U o I o P o + L o C o L o C o V Ω Ω ma V V ma mw mh mf mh mf 0-35 6 43 86 3.5 5. 5. 5. 8 0 740 0 760 *) only for channel : leakage current at 4 V / 35 V I leak ( ma / 0 ma.3.5 0.07 0.07 0.04 7.4 7.35 0.8 0.8 0.8 00/3-5--04 *) Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible external inductance U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power /4 Safety s 05-03- AK00 III en

Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Application case Analog output (current source) for I/P converter etc., field circuit unearthed 4... 0 ma 00/3-5--04 +0... 35 V DC Operating data Operating voltage Operating current Maximum voltage drop at the safety Safety data Maximum voltage = + 0... 35 V I N = 0... ma ΔU max ( 8. V U o = 5. V I o = ma external inductance L o.5 mh external capacity C o 0.04 μf Maximum power P o = 763 mw 7.35 mh 0.8 μf Analog output (current source) for I/P converter etc., field circuit unearthed 053E0 00/3-5--04 +0... 35 V DC 06604E0 Operating data Operating voltage Open-circuit output voltage (terminal 3 4, I n = 0) U L) Operating current Safety data Maximum voltage = + 0... 35 V I N = U L / 43 Ω + R L U o = 5. V I o = ma ( 4 V - 3.5 V external inductance L o.5 mh > 4 V V 7.35 mh external capacity C o 0.04 μf 0.8 μf Maximum power Application note P o = 760 mw This safety is used if the automation system activates the analog output signal in the return (negative) line. The field device and automation system are not earthed and unregulated power supply can be used. 05-03- AK00 III en Safety s /5

Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: + Function: Channel current supply Channel evaluation Connection to regulated power supply Installation permitted in Division and Zone 0586E0 Channel R min R max I max ãu Safety data Order number U o I o P o + + + L o C o L o C o V Ω Ω ma V V ma mw mh mf mh mf 6 6 4 4 4 4 5 3 6 08 358 0 48 67 8... 8 8 8 8 8 8 *) only for channel : max. leakage current I leak ( 0 ma 3 5 0 3 3 07 3 0 00 5 0 630 65 74 770 0.3 000 0.37..35.5 0.3 0.3 0.3 0.08 0.08 3.8 000 3.5 4 3.6.4.4.38 0.636 0.635 00/3--5-00 *) 00/3-80-03-00 00/3-80-0-00 Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible external inductance U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power /6 Safety s 05-03- AK00 III en

Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Application case Load cell (DMS) 3 Ω or 700 Ω 6 conductors + 6 V, field circuit unearthed 00/3--5-00 00/--030-00 00/--030-00 +6 V Operating data Operating voltage ( + 6 V Voltage for load cell and electric U L (at = + 6 V) line Current for load cell I L (at = + 6 V) Number of the load cells connected in parallel 3 Ω 700 Ω U L (V) I ma (V) U L (V) I ma (V) 0.4 30. 7 8.3 47 0.4 30 3 6. 60.5 4 4 5. 67 8.3 47 Safety data Maximum voltage U o =. V I o = 85 ma external inductance L o 0. mh.8 mh external capacity C o 0.3 μf.4 μf Maximum power P o =.4 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 55 ma, the maximum power to P o =.3 W. Discrete -wire output for solenoid valves, LEDs and signalling devices 063E0 00/3-80-0-00 +4VDC 06605E0 Application note This is suitable for use with regulated power supplies and earthed return circuits. The nominal voltage is 4 V. -wire 4/0 ma I/P converters and control valves - standard and HART, 4/0 ma indicators 4... 0 ma 00/3-80-0-00 +4VDC Application note 334E0 This safety is used if the automation system activates the analog output signal in the return (negative) line. The field device and automation system are not earthed and a regulated power supply must be used. At an operating current of 0... ma, the maximum voltage drop across the will be 8.4 V. 05-03- AK00 III en Safety s /7

Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: + Function: Channel current supply Channel evaluation No safety-relevant output current I o for channel Connection to unregulated power supply on to channel Nominal current limited to 35 ma Installation permitted in Division and Zone 0587E0 Channel R min R max I max ãu Safety data Order number U o I o P o + L o C o L o C o V Ω Ω ma V V ma mw mh mf mh mf 0-35 6 37 5 3.5 8 8 8 7 0 00 67 700 *) only for channel : leakage current < 6 V / > 6 V I leak ( ma / 35 ma.8.55 0.08 0.635 00/3-80-00-04 *) Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible externa l inductance U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power Application case 3-wire PNP inputs (positive switching) of proximity switches, photocells and encoders PNP Supply 00/3-80-00-04 V +0... 35 V DC +0 V 0655E0 /8 Safety s 05-03- AK00 III en

Two-channel safety s, evaluation potential: + / evaluation potential: + Series 00/33 Series 00/33 Two-channel safety s, evaluation potential: + / evaluation potential: + 058E0 Evaluation for direct current signals with max. output current I o Suitable for potential-free contacts and floating 4/0 ma signals Positive potential of both channels Installation permitted in Division and Zone Channel I max ãu Safety data Order number + U o I o L o C o L o C o V ma V V ma mh mf mh mf 5.5 5.5 *).5 V to 0 ma 60 60 3.5 *) 3.5 *) 8 8 8 0 0 0 000 000 000 000 000 000 00/33-80-000-00 Nominal voltage U o Maximum voltage C o max. permissible external capacity I max Maximum output current I o ãu Additional voltage drop across the safety L o max. permissible external inductance 05-03- AK00 III en Safety s /

Two-channel safety s, evaluation potential: + / evaluation potential: - Series 00/34 Series 00/34 Two-channel safety s, evaluation potential: + / evaluation potential: - -Ue R L -Ue Evaluation for direct current signals with max. output current I o Application for passive signals of 4/0 ma (transmitter with 4 conductors or more) with insulated analog input on the control system Channel for positive and negative potential in one module Installation permitted in Division and Zone 0588E0 Channel I max ãu Safety data Order number U o I o + L o C o L o C o V ma V V ma mh mf mh mf + 6-5 *).5 V to 0 ma 00 00 3.5 *) 3.5 *) 8 8 8 0 0 0 000 000 000 0. 8.4 000 000 000.4 00 00/34-80-000-00 Nominal voltage U o Maximum voltage C o max. permissible external capacity I max Maximum output current I o ãu Additional voltage drop across the safety L o max. permissible external inductance Application case Vibration sensor 4... 0 ma 00/34-80-000-00 05E0 Operating data Operating current Load Maximum voltage drop at the safety Safety data Maximum voltage external inductance I N = 0... ma R L (7 Ω Δ U max ( 3.5 V U o = 8 V I o = 0 ma external capacity C o μf Maximum power Application note The inductance is determined depending on the maximum current of the transmitter P o = 0 mw μf A potential-free input is required for the circuit. If the input is earthed, (R L to /PA), the safety 00/03-80-000-00 can be used. /0 Safety s 05-03- AK00 III en

Two-channel safety s, star / star Series 00/77 Series 00/77 Two-channel safety s, star / star /-Ue /-Ue Connection to regulated power supply Suitable for voltage signals Installation permitted in Division and Zone AC version /-Ue /-Ue Channel R min R max Safety data Order number U o I o P o 05836E0 + 6 + 6 + 6 + + 8 + 8 + 4 L o C o L o C o V Ω Ω V ma mw mh mf mh mf 4 4 7 7 60 60 3 3 5 5 657 657 545 545 8. 8. 6. 6. 6 6 358 358 80 80 730 730.3.3.3.3.3.3 0 0 0 5 5 5 8 8 8 *) Ambient temperature - 0... + C 0 0 40 300 00 00 400 300 73 73 46 48 48 6 47 47 4 0 3 3 700 0 0 000 560 560 30 400 400 800 80 80 630 330 330 660 0 0 3.3.3 0. 0.5 0.5 0.5.3.3 0. 7 7.4.35.35 0.4 0. 0..6 4. 4. 4. 4. 4. 4. 3 3 3 0.58 0.58 0.58 330 330 87 7 7.8 4 4 0.8 7 7.8 6 6 7.4 7. 7..84 30 30.5 3 3 3 3 3 3 0. 0. 0. 3.55 3.55 3.55.4.4.4.4.4.4 00/77-03-040-00 00/77-03-300-00 00/77-00-400-00 00/77--300-00 00/77-0-46-00 *) 00/77-0-6-00 *) 00/77-80-04-00 Nominal voltage U o Maximum voltage L o max. permissible external inductance R min R max Minimum resistance of the safety Maximum resistance of the safety I o C o max. permissible external capacity P o Maximum power 05-03- AK00 III en Safety s /

Two-channel safety s, star / star Series 00/77 Application case Load cell (DMS) 3 Ω or 700 Ω 6 conductors +/- 7.5 V (5 V), field circuit unearthed +7,5 V 00/0-87-70-00 -7,5 V 00/0-87-00-00 00/77-03-040-00 Operating data Operating voltage ( +/- 7.5 V (5 V) Voltage for load cell and U L (at ( +/- 7.5 V) electric line Current for load cell I L (at ( +/- 7.5 V) Number of the load cells 3 Ω 700 Ω connected in parallel U L (V) I ma (V) U L (V) I ma (V).6 35 3..6 55.6 35 3 8 70 0.6 45 4 7 80.6 55 Safety data Maximum voltage U o = 8.7 V I o = 330 ma external inductance L o 0.8 mh.45 mh external capacity C o 0.7 μf.64 μf Maximum power P o =.4 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 30 ma, the maximum power to P o =.36 W. Thermocouples Voltage Input 06E0 00/77-03-300-00 Operating data Maximum series resistance R max = x 8. Ω of the safety Sensor voltage U ( +/- 4 V eff / 6 V pp Safety data Maximum voltage U o =.3 V I o = 300 ma external inductance L o 0. mh external capacity C o 4. μf.8 mh 3 μf 058E0 / Safety s 05-03- AK00 III en

Two-channel safety s Series 00 Series 00 Accessories and Spare Parts Designation Figure Description Art. no. Weight Back-up fuse Label carrier 0E00 for all safety s of Series 00, 00 and 004 Packaging unit: 5 pieces kg 5864 0.008 5877 0.00 Labelling sheet 00E00 perforated, for automatic inscription Format: DIN A4 5873 0.005 0E00 Adapter 5886 0.006 0E00 Clamping base, moulded material DIN rail 04E00 6583 0.004 NS 35 / 5 (available by the metre) 0374.40 Protective conductor terminal 03856E00 USLKG 5 (clamping range ( 4 mm ) 760 0.0 06E00 Earthing terminal USLKG 6 N (clamping range ( 6 mm ) 5 0.030 06E00 Fuse holder 58834 0.00 Insulation and fastening material 07E00 for mounting rail NS 35/5 5888 0.03 08E00 05-03- AK00 III en Safety s /3

Two-channel safety s Series 00 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 7 mm /. 83 " 03 mm / 4.06 " mm / 0.4 " 7 0E00 Safety s 00, 00, 004 80 mm / 3.5 " 5 mm / 3.74 " 76 mm / 3.00 " Safety 00, 00, 004 mounted on the mounting rail LV 35/5 030E00 66 mm.60 " 38 mm. " 03E00 Safety 00, 00, 004 mounted on the mounting rail LV 3 with adaptor and clamping base made of moulded material 66 mm.60 " 38 mm. " Safety 00, 00, 004 mounted on mounting plate with adaptor 033E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /4 Safety s 05-03- AK00 III en