DUK COMPACT ULTRASONIC FLOWMETER

Similar documents
DUK. Compact Ultrasonic Flowmeter

DUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit

DVZ COMPACT VORTEX FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

Operating Instructions for Ultrasonic Flowmeter/ -Monitor/ - Counter/ -Dosing Unit. Model: DUK

TUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)

DVZ. Vortex Flowmeter Compact. for low viscosity liquids

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Operating Instructions for Compact Vortex Flow Meter. Model: DVZ

RCM DIRECT READING FLOWMETER

Operating Instructions for Compact Magnetic-Inductive Flow Meter. Model: MIK

INLINE flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement

Electromagnetic flowmeter in all metal design Model MIM

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

NGR. Guided Wave Radar Level Transmitter

Digital flow transmitter for continuous flow measurement

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

MIM. Electromagnetic Flowmeter. Compact, All-metal Design

Electronic Temperature Transmitters

ph or ORP Transmitter

Digital flow ELEMENT transmitter for continuous flow measurement

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Digital batch controller

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

NE CONDUCTIVE LEVEL SWITCH

S 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.

Liquid Level Switches

Valve Island with Electronic I/O

SonoMeter 31 Energy Meters

Digital flow ELEMENT transmitter for continuous flow measurement

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Level switch Nivotemp NT-EL, NT-ELD

Electromagnetic Flow Transmitter

ED701 General Industry Pressure Transmitter

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

Electromagnetic flowmeters and switches DWM 1000/2000

Conductivity Transmitter

FLOWave SAW-Flowmeter

Ultrasonic level transmitter, non-contact

B r e a k t h r o u g h F l o wmeter Technology. Ultrasonic Flowmeter Range

Electronic Pressure Switch Type MEP

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

ALGERIA, ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

TURCK Inc Campus Drive Minneapolis, MN Application Support: PROX Fax: (763)

Digital inductive conductivity transmitter

FLOMID FX Electromagnetic Flowmeter

Pressure transmitter for general industrial applications Model A-10

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

Signet 9950 Dual Channel Transmitter

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Universal process controller econtrol

Introducing GPI s Latest

Digital conductivity transmitter

NBK-04. Level Indicator for Tank-Top Mounting

Target disk flowmeter for liquids and gases

PAD - Heavy Duty Differential Pressure Trasmitter

Pressure transmitter for general industrial applications Model A-10

Model Sono-Trak Transit Time

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

NAT Applications. Features

Materials (other materials see WIKA diaphragm seal program) Model S-10

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Signet 9900 Transmitter

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

TMU. Coriolis Mass Flow Meter. for liquids and gas

Flow - Rotor. Characteristics. Applications. Mechanical-magnetical, Infrared. Quantity measurement for filling processes

Universal process controller econtrol

Magnetic Inductive Flow Sensors induq. Series VMI

The transducer component converts the measured signal and displays the actual value.

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Features. Picture. Specifications. Pressure Transmitter 4-20mA 2-wire MPG Type: MPGxxxxxxxx for level measurement Order No.: see Table 1 / Page 4

Magnetic Inductive Flow Sensors VMI Series

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

PSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs

Universal process controller econtrol

SENSORS. Seamlessly Integrated SENSORS

Pressure transmitter For general industrial applications Model A-10

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

NAT Applications. Features

Signet 9900 Transmitter

Signet 9900 Transmitter

Signet 9950 Dual Channel Transmitter

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

ULTRAFLOW. Application. Cooling flow sensor. Ultrasonic flow sensor. Compact design. Static meter with no moving parts. Large dynamic range.

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Transcription:

DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F Connections: ½ to 3 G or NPT Material: Brass or.4408 Stainless Steel Outputs: Analog, Frequency, Switching, Compact Electronics with Digital Displays, Batching and Totalizing Electronics 0-00 USA KOBOLD Instruments Inc. 80 Parkway View Drive Pittsburgh, PA 0 PH: + 4-788-830 FAX: + 4-788-4890 E-MAIL: info@koboldusa.com CANADA KOBOLD Instruments Canada Inc. 9A Aviation Pointe-Claire, QC H9R 4Z PH: + 4-48-8090 FAX: + 4-48-8899 E-MAIL: kobold@kobold.ca MEXICO Camino Dorado 3 Misión Cimatario Querétaro 76087, Qro. Mexico PH/FAX: + (44) 9 67 E-MAIL: contreras@kobold.com Visit KOBOLD Online at Model: DUK

Description measuring, monitoring, metering, and batching of low The devices work on the principle of run time difference. Two sensors mounted opposite one another in the pipeline function simultaneously as transmitter and receiver of the ultrasonic signals. - The run time difference, which is determined by a micro- Advantages High turndown ratio: 0: Small pressure loss Highly Repeatable Measurement independent of density and temperature changes Areas of Application Machine building Automotive Robotic Cooling Hot water T V m C L Electronic The devices can be equipped with a switching, a frequency or an analog. In addition, a compact electronic can be selected that features a digital display, a switching, and an analog. The device series is rounded off by an optionally available batching or totalizing electronic. The meter electronic indi- - log and two relay s can be used for further processing of the signals. Measuring Ranges and Weights T Technical Details Measuring principle: Ultrasonic Range: See Table Media: Liquids with max. % solid Viscosity: Max. 3 cst Accuracy: ±.% of F.S. Repeatability: ±0.% of F.S. Mounting Position: arrow (horizontal: electronic on top or below) Straight Piping: 0 x pipe diameter in/out Media Temperature: - 4 to 94 F -4 to 48 F (High temperature version) Ambient Temperature: - 4 to 8 F Response Time: Approx. 0... s (depending on electronic version) Max Pressure: 30 PSI Pressure Loss: Max.. PSI at F.S. Protection: IP 6 / NEMA 4 Wetted Parts Sensor Housing: Brass or.4408 Stainless Steel Sensors: PEEK Seal: NBR (other on request) Model Measuring range G [GPM] Measuring range H [LPM] Size [G/NPT] DUK-...S30x DUK- F3x0 DUK-...Lx43 DUK-...C3xx DUK-...Ex4R DUK-...Gx4R DUK with ADI 4 V DC DUK with ADI 30/ V AC DUK-xxx4 0.0-0.08-0 ½.87 LB.3 LB.0 LB 4.74 LB.9 LB DUK-xxx 0.04-0 0.6-40 ¾.3 LB.76 LB.6 LB.8 LB 6.39 LB DUK-xxx6 0.06-6 0. - 63 3.0 LB 3.64 LB 3.3 LB 6.06 LB 7.8 LB DUK-xxx8 0.6-40 0.6-0 ½.8 LB.6 LB. LB 8.0 LB 9.6 LB DUK-xxx9 0. - 6-0 8.38 LB 8.8 LB 8.7 LB.4 LB.46 LB DUK-xxxB 0.6-60. - 630 3.6 LB 6.09 LB.98 LB 8. LB 9.73 LB 0-00

DUK-...S300, DUK-...S30D Bicolor LED for switch status Switching Output (..S300):SPDT relay, max. A/30 V DC Switching Output (..S30D):Active 4 V DC, N/C and N/O Switch Point: 0 to90% of f.s. in 0%-steps using a rotary switch Power Supply: 4 V DC ±0% Power Consumption: 30 ma Electrical Oonnection: Plug M, -pin DUK-...F300, DUK- F390 Pulse Output: PNP, Open Collector, max. 00 ma Frequency at F.S.: 00 Hz ( F300) 0 to 000 Hz ( F390) Power Supply: 4 V DC ±0% Power Consumption: ma Electrical Connection: Plug M, -pin DUK-...L343 Analog Output: 4-0 ma, 3-wire Max. 00 Power supply: 4 V DC ±0% Power Consumption: Max. 4 ma Electrical Connection: Plug M x DUK-...L443 (Required with optional AUF-3000) Output: 4-0 ma, 3-wire Max. 00 Power Supply: 4 V DC ±0% Power Consumption: Max. 4 ma Electrical Connection: Plug DIN 4360 DUK-...C3xx (Compact Electronic) 3-digit LED Analog Output : 4-0 ma adjustable (only DUK-...C34x) Max. 00 Switching Output: () semiconductor PNP or NPN Contact Function: N/C-N/O-frequency programmable (approx. 400 Hz at F.S., uncalibrated) Via buttons Power Supply: 4 V DC ±0% Power Consumption: Approx. 00 ma Electrical Connection: Plug M x DUK-...Ex4R (Totalizing Electronic) LCD, x 8 digit, illuminated rate, total and grand total, units selectable Analog Output: 4-0 ma adjustable Max. 00 Switching Output: relays, max. 0 V/ A/000 VA Via 4 buttons Functions: Reset, MIN/MAX memory, total and grand total, language Power Supply: 4 V DC ±0%, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable connection or M plug More technical details see datasheet ZED in the brochure Z DUK-...Gx4R (Batching Electronic) LCD, x 8 digit, illuminated batching, total and grand total, units selectable Analog Output: 4-0 ma adjustable Max. 00 Switching Output: relays, max. 0 V/ A/000 VA Via 4 buttons Functions: Batching (relay S), start, stop, amount, quantity, language Power Supply: 4 V DC ±0%, 3-wire Power Consumption: Approx. 70 ma Electrical Connection: Cable connection or M plug More technical details see datasheet ZED in the brochure Z DUK with ADI Electronic Bar graph and 3.-digit digital combination display; batch system Analog Output: 4-0 ma, 0 to 0 V Switching Output: x relays/ SPDT max. /30 V AC, A resistive load max. 30 V DC / A or Open-Collector -0 V DC, I total. = 0 ma Via 3 buttons Power Supply: 30/ V AC, 4 V DC Electrical Connection: Terminal block via cable gland More technical details see datasheet ADI electronic in the brochure Z 0-00 3

Electrical Connection DUK-...S300 DUK-...S30D N/O common N/C N/C N/O DUK- F3x0, DUK-...L343 DUK-...L443 n.c. signal out 3 signal out +V S DUK-...C30* DUK-...C34* switch out 0(4)-0 ma switch out switch out DUK-...E4R, DUK-...G4R Cable Connection DUK-...E34R, DUK-...G34R Plug Connection Wire number DUK-...E4R totalizing electronic 4 V DC 4 V DC DUK-...G4R batching electronic -0 ma 4-0 ma 4 reset total part Control * 6 n. c. Control * 7 relay S relay S 8 relay S relay S 9 relay S relay S 0 relay S relay S * Control <-> : Start-Batching Control <-> : Stop-Batching Control <-> Control <-> : Reset-Batching +4 V DC reset/ctr * U 4 3 d.c./ctr * 30 V AC/DC / A U S 7 8 3 6 4 0 (4) - 0 ma out max. 00 Ω S 4 0-00

Order Details (Example: DUK- N4 G S300 L) Model / Housing Material Connection Range Output / Electronic Flow Direction Switching Output S300 = relay, M-plug S30D = active 4 V DC, M-plug Frequency Output F300 = M-plug, 00 Hz F390 DUK- = Brass DUK- = St. St. DUK- = High Temp Brass DUK- = High Temp St. St. G4 = G ½ G = G ¾ G6 = G G8 = G ½ G9 = G GB = G 3 N4 = ½" NPT N = ¾" NPT N6 = " NPT N8 = ½" NPT N9 = " NPT NB = 3" NPT G = GPM H = LPM Analog Output L343 = M-plug, 4-0 ma L443 = DIN-plug, 4-0 ma Compact Electronic C30R = xopen Collector, PNP C30M = xopen Collector, NPN C34P = 4-0 ma, xopen Collector, PNP C34N = 4-0 ma, xopen Collector, NPN ADI Electronic Display Power Supply Output Contacts K = bar graph/ digital display A = batching unit 0 =30 V AC 4 = V AC 3 = 4 V DC 0 = without 0 = without = 0-0 V = relay SPDT 4 = 4-0 ma 6 = Open Collector L = from left to right R = from right to left T = from top to bottom B = from bottom to top Totalizing Electronic E4R = LCD, 4-0 ma, xrelays, m cable E34R = LCD, 4-0 ma, xrelays, M-plug Batching Electronic G4R = LCD, 4-0 ma, xrelays, m cable G34R = LCD, 4-0 ma, xrelays, M-plug Accessories: P/N 807.037 = 4-Pin Micro-DC connector with 6-foot cable for types F300, F390, L 343, S30D P/N 807.007 = -Pin Micro-DC connector with 6-foot cable for types C3xx, S300, E34R, G34R Dimensions DUK-Sensor Model G/NPT SW H L B DUK-xxx4 ½.8.4 4.49 ca..83 DUK-xxx ¾.4..98 ca..99 DUK-xxx6.8.48.7 ca. 3. DUK-xxx8 ½.36.7 7.48 ca. 3.4 DUK-xxx9.99.9 9.37 ca. 3.8 DUK-xxxB.3 3.3.0 ca. 4.80 0-00

Dimensions DUK- S30x, DUK- F3x0, DUK- L343 DUK- L443 8 Mx 60 34 7. 8 34. 60 7. DUK- C3xx DUK- Ex4R, DUK- Gx4R Ø44. 48 90 34 7 8. Mx ca. 6. 60 DUK with ADI Electronic OBOLD Dimensions in mm 6 0-00