Specialty Switches. Inertia Engineering & Machine Works, Inc Hardaway Road, Stockton CA 95215

Similar documents
The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

SINGLE-PHASE VSV SWITCH

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

SINGLE-PHASE VSV SWITCH

Distribution/Substation Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Dynamo Brushless DC Motor and GreenDriveTM Manual

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Customer Requirements RF Antenna Installations

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

CHAPTER 15 GROUNDING REQUIREMENTS FOR ELECTRICAL EQUIPMENT

Type DMX-N Surge Arresters Maximum System Voltage 2 to 36 kv

S&C Series 2000 Circuit-Switchers Outdoor Transmission (69 kv through 230 kv)

Variable Transformers Product Design & Engineering Data

SECTION PANELBOARDS

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Wisconsin Contractors Institute Continuing Education

Liquid-Filled Transformers

SECTION TRANSFORMERS

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

American Electrical Institute

CONTINUING EDUC ATION

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

Copper Core & Coil Transformer

Section 11 Electronic Position Controls & Encoders

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

Article 250 Grounding & Bonding

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

POWER SERVICE DETAILS

ULTRA-K Series 600K - he

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Regional Technical Seminar

7.5 kva Isolation Transformer - 460V Primary - 230V Secondary - NEMA 3R - Single Phase - 50/60 Hz

230/26kV Steelbald T3 Replacement project ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO.

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

USER MANUAL. Maxwell Technologies BOOSTCAP Ultracapacitor Energy Storage Modules for Low Duty Cycle Applications

Portable Dipole Shortwave Antenna (PDSA-7)

INSTALLATION INSTRUCTIONS: SHD-SO239-LA(2.0

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

230/26kV Brandy Branch T2 Substation Addition JEA ITEM QTY. DESCRIPTION MFG. TYPE OR CAT. NO.

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

3Ø Short-Circuit Calculations

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

SPECIFICATION FOR HORIZONTAL AIRFLOW OUTDOOR RESISTIVE LOAD BANK

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

Transmission Line Support Systems

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

Dry Type Transformers Full Line Catalog. jeffersonelectric.com

CONTENTS CABLE MANAGEMENT AND

Chapter 1. Applied Grounding and Bonding. Applied Grounding and Bonding 9/18/2011. Introduction. Introduction. Paul Dobrowsky Member NEC Panel 5

INTERNATIONAL TRANSFORMERS. Acme Electric s broad selection of CSA energy efficient transformers

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Substation Design Volume VII

Tarheel Antennas, Inc.

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

Series 80 In-Line Mounted Centrifugal Pumps

SBS Connectors - up to 110 amps

ZUCCHINI MS - LOW TO MEDIUM POWER BUSBAR

kv AC substation

Pole Line Hardware. Heavy-Duty Spool Rack (200 A) No. of Wires. Anti-Vibration Kit for Spool Rack. Heavy-Duty Spool Rack (400 A) No.

MAST ARMS & POLES. Ornamental Pole Top & Bases

PF/PFQ. High Amperage plug and receptacle. Main Advantages

Warehouse Stock Transformers

B. Manufacturers: Square-D, G.E. or Westinghosue.

Model 50 Ground Loop ph Sensor Model 55 Solution Ground ph Sensor

Electrical Wiring: Commercial, Seventh Canadian Edition

80 kva Isolation Transformer - 480V AC Primary - 20V AC Secondary - NEMA 3R - Single Phase

Installation & Operation Manual

3.0 CHARACTERISTICS. Type CKO Overcurrent Relay. switch, which allows the operation indicator target to drop.

Minimizing Plant Interruption Caused by Line Disturbances Using Active Voltage Conditioners

SB 50 Connectors - up to 120 amps

Hardware Pkg

General Information...SA1-SA4

Short Circuit Current Calculations

Hendrix Tap, Tie & Ground Wire

TOLL FREE:(888) FAX:(941) ASSEMBLY of ProTEC CONCRETE STRUCTURAL INSULATED PANEL

Utility Systems Technologies, Inc. Sag Fighter. Deep Voltage Sag Protection:

10 kva Transformer - 480V Primary Voltage - 208V Secondary Voltage - Single Phase - NEMA 3R

User's Manual: Series 250T AC Current Input (External Sensor) Two-Wire Transmitters

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Transcription:

Specialty Switches Inertia Engineering & Machine Works, Inc. 6665 Hardaway Road, Stockton CA 95215 Tel: 800-791-9997 Fax: 209-931-8186 E-mail: sales@inertiaworks.com

Section 4 - Specialty Switches Specialty Switches... 4.0 CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved LineBOSS 5 kv - 38 kv Non-Interrupting Regulator/By-Pass, Specialty Switch...4.10 LineBOSS NBS Selection Guide...4.10.1 NBS Non-Interrupting Bypass Switch Request For Quotation.... 4.11 LineBOSS NBS Switch Application Guidelines... 4.12 NBS Non-Interrupting Regulator/By-Pass Switch Operating Sequences...4.13 NBS 5 kv - 38 kv Configuration Drawings 9216-47R-2M NBS, 15-38 kv, One Pole, Hookstick Dimensions... 4.20 9216-48-1M NBS, 15-38 kv, Two Pole (10 Arm), Hookstick Dimensions. 4.21 9216-51M NBS, 15-38 kv, Three Pole, Hookstick Dimensions... 4.22 9216-17-2M NBS, 15-38 kv, Three Pole H-Frame, Recip. Dimensions... 4.23 9610-25M NBS, 15-38 kv, Three Pole H-Frame, Hookstick Dimensions.. 4.24 LineBOSS GBS 15 kv - 69 kv Sidebreak Type, Loadbreak/Grounding Switch Specialty Switch...4.50 LineBOSS Loadbreak/Grounding Switch Selection Guide...4.50.1 GBS 15 kv - 38 kv Configuration Drawings 9330-13M 38 kv Horizontal Underarm Grounding Switch Dimensions.... 4.51 6400GM Fused Grounding Switch (38 kv), ArcWhip, Recip. Ctrl., Dimensions 4.52...4.52 Specialty Switches 4.0

LineBOSS NBS 5 kv - 38 kv Non-Interrupting Regulator/By-Pass, Specialty Switch CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved The LineBOSS NBS, Nielsen Bypass Switch, was originally designed in 1972 by Carl Nielsen, P.E. to allow non-interrupting bypassing and energizing (cut-in or cut-out) fixed booster transformers. The NBS switch now provides continuous power to load-side customers when energizing or de-energizing one, two, or three phase fixed booster, auto-booster and regulator transformers as required by voltage conditions or for routine maintenance or replacement. The conventional combination bypass-disconnect switch used for de-energizing multi-step regulators; first requires the regulator be placed in the neutral position. As the switch opens, a shorting bar is inserted across the main line leads and the regulator series winding. If the regulator tap changing mechanism or the position indicator has malfunctioned and the regulator is not in the neutral position, attempting a by-pass operation can result in excessively high circulating current in the series winding which can damage or destroy the series tap changer mechanism, the switchgear, bus work and endanger personnel. The NBS bypass switch eliminates this safety hazard by controlling the series winding circulating current by use of a current limiting resistor, while providing uninterrupted service to load side customers. The transfer series resistor assembly permits bypassing multi-step regulators in the buck or boost position (refer to application calculations). TYPICAL APPLICATION: Cut in a 762 kva (7620 V, 100 A), single-phase regulator to boost the voltage. The regulator indicates that it is in neutral, but it is actually at step one. The circulating current could be as high as 31 ka during the switching operation using a standard combination bypass disconnect switch. The NBS switch, with its current limiting series resistor assembly, limits the circulating current to less than 24 A without interruption of service. THE TWIN FEED NBS: The NBS-2D is designed for use on fixed boosters and auto-boosters that are on circuits that have preferred and alternate source directions. The NBS-2D allows the booster or auto-booster to boost in the direction of the load when the alternate source is being utilized. The NBS-2D provides a switching method for re-routing the source feed to the booster transformer without re-wiring the buswork. The NBS-2D is not required on multi-step regulators. STANDARD FEATURES Unitized or modular construction on aluminum or steel crossarms for fast and easy installations. Factory adjusted, ready to mount with minimal, if any, field assembly required. Available with silicone (std.) or porcelain insulators. Reverse loop, silver plated copper jaw contacts. Maintenance-free, sealed, stainless steel ball bearings. Meets all applicable NEMA and ANSI standards. All ferrous components are hot dip galvanized. Tinned copper two-hole and four-hole terminal pads SWITCH RATINGS: Voltage Class: 5 kv, 15.5 kv, 25.8 kv & 38 kv Continuous Current Class: 600 A Transfer & Continuous STANDARD CONFIGURATIONS Single-pole units, unitized, reciprocating handle Double-pole unit, unitized, reciprocating handle Double-pole unit, two-way feed, unitized Three-pole unit, unitized, reciprocating handle Single-pole, pole mounted (direct to pole), hookstick Single-pole, substation (double crossarm) mounted Twist-Assist hookstick operated, direct to pole 4.10

LineBOSS NBS Selection Guide Non-Interrupting Bypass Switch = N ARMORGALV = NT Voltage Class: Current Rating: 600 A = 6 900 A 1 = 6 900 A 2 = 9 1200 A = 1 *Switching Current Limited to 600A. Insulator Type: Polymeric Silicone (3.0 BC) Porcelain (3.0 BC) 15.5 kv (110 kv BIL) = 1 25.8 kv (150 kv BIL) = 2 38.0 kv (200 kv BIL) = 3 = S = P Interrupter Type: Amprupter, Loadbreak 3 = L ArcWhip, Quick-break 3 = Q Dual Amprupter, Loadbreak = 1 Dual ArcWhip, Quick-break = 2 No Interrupter = X Crossarm Type: Aluminum = A Fiberglass = F Galv. Steel = S ( SX for Heavy Duty Arm) No Xarm = X Customer specified loading (call factory). 1 900 A (Temp Rise: 30 C Momentary: 40 ka) 2 900 A (Temp Rise: 30 C Momentary: 51 ka ANSI) 3 Source side only. 4 Right side mounting is standard unless otherwise specified in options. 5 Specify structure dimensions. N16SQS11222S Mounting Configuration: Single Phase (10 ft. Crossarm) 4 = 1 Two Phase (10 ft. Crossarm) = 2 Three Phase (10 ft. Crossarm) = 3 Single Phase (76 in. Crossarm) 4 = 4 Two Phase (H-Frame) 5 = 5 Three Phase (H-Frame) 5 = 6 LineBOSS Standard Configurations Options: Terminals (Specify) = S Double Crossarm Base = T For others call factory or see Options Chart for a complete listing. Control Rod Length: 20 ft. (Standard) = 2 Specify (10 Sections) = See Options Chart for insulated section. Control Location: Specify the quadrant by number, where the control is to be located. See Control Options Chart. Control Rod Type: Reciprocating ( ) 1 Round Fiberglass = 2 3/4 Galvanized Pipe = 3 Torsional ( ) 1 1/2 Galvanized pipe = 6 Control Mechanism: Reciprocating Handle ( ) = 1 Torsional Handle ( ) = 2 Hookstick (Twist Assist) = 3 Add C for counter-clockwise to open. CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved 4.10.1

NBS Non-Interrupting Bypass Switch Request For Quotation E-MAIL: sales@inertiaworks.com FAX: (209) 931-8186 Company Name Address 1 Address 2 City State Zip code Contact Name Telephone Number Facsimile Number E-mail address Make copies of this form to transmit your switch requirements. If you have a standard s drawing, please send it along with this fax form. Step 1. Voltage Class: 15kV 25kV 38kV Step 2. Continuous current rating: 600A 900A 1200A Step 3. Insulator type: Silicone Porcelain CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved Step 4. Interrupter type: ArcWhip (Default) AmpRupter Dual AmpRupter Dual ArcWhip None Step 5. Crossarm type: None Galvanized Steel Fiberglass Aluminum Step 6. Select the configuration (circle one): Table 1: Minimum Phase Spacing [in.] Voltage Class [kv]: Dim. B Dim. C Dim. D Dim. E 15 31 41 38 27.5 25 33 44 44 30.5 35 36 49.5 50 36.5 Step 7. Select Spacing: Standard Custom (Fill in Spacing Dimensions below using Table 1 and configurations in Step 6.) B C D E Step 8. Select control mechanism: Hookstick Reciprocating ( ) Torsional ( ) Step 9. Select control rod: Galvanized pipe: ¾ IPS galv. Pipe Fiberglass: 1 round Step 10. Select control rod location (See Fig.1): Step 11. Select control rod length: 10 ft. 20 ft. Other Figure 1: Control Quadrants 4.11

Step 12. Select additional accessories and modifications: (check off and write in) Source & Load Solid Blade Disconnects: Yes (Default) No Load/Source Disconnect Position (See Fig. 2): CW (Default) CCW Figure 3: Mounting Side Options Figure 2: NBS Connection Diagram Left side phase mounting (Available on Configuration 1 & 4 only, see Fig. 3) Double crossarm base (See Fig. 4). Pole mounting bands; Specify pole diameter range: Substation mounting: Specify base mounting dimensions or furnish drawing. Figure 4: Double Crossarm Base Terminals: Terminal paddle for fired wedge connectors (specify size) Terminals, 2-hole copper NEMA pad #2-500 kcmil ( 600 & 900 A switch) Specify: Terminals, 4-hole copper NEMA pad 500-750 kcmil (1200 A switch) Specify: Terminals, other; (specify size) Crossarm Braces: Galvanized Steel Fiberglass Grounding connector on crossarm, AWG range # 6-4/0 diameter Bonded handle ArmorGalv AG3000 (Thermal Diffusion Galvanizing) ferrous component coating 1. 1 Ferrous components come Hot Dipped Galvanized (HDG) standard. Armorgalv AG3000 Thermal Diffusion Galvanizing (TDG) offers increased corrosion resistance. CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved 4.11.1

LineBOSS NBS Non-Interrupting Regulator/By-Pass Switch Application Guidelines Using a standard combination bypass disconnect switch, the voltage differential across the series winding in the regulator is shorted out during the switching sequence. This produces an extremely high circulating current when in the lower tap positions (not in neutral). The INERTIA NBS eliminates this high current by placing resistance in series with the regulator series winding. The maximum boost or buck voltage differential is limited to 1200 volts (600 A rating x 2 ohms). The maximum switching position for a given regulator can be determined by the calculations shown: 1. Determine the voltage change per step of the regulator or booster transformer: CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved 2. Determine maximum boost or buck tap position: 3. Determine maximum current at tap position 1: Example: Line voltage is 13,800 volts, 10% max. boost or buck with 16 positions boost or 16 positions buck. Conclusion: The NBS will safely switch this 13,800 V regulator at tap position 13. At step one, where the circulating could be as high as 43,125 Amps based on 0.002 Ohms series winding impedance, the current is mitigated to 43.1 amps while switching. ***NOTE: Always attempt to return the regulator to neutral before switching. This device is not intended to change the safety or standard operating practice of switching regulators. The NBS switch allows an added margin of safety when switching regulators. When neutral position can not be definitely confirmed, the NBS will allow safe switching in the off-neutral position as long as the differential voltage across the transformer series winding does not exceed 1,200 V. INERTIA s NBS, Non-Interrupting Bypass Switch, protects personnel and equipment, and eliminates the downtime and other costs associated with taking an outage to switch regulators, fixed or autobooster transformers. It provides additional personnel and equipment safety in line distribution and substation applications. 4.12

LineBOSS NBS Non-Interrupting Regulator/By-Pass Switch Operating Sequences BYPASS POSITION The NBS bypass switch is shown here in the Cut-out or bypass position. The current path is indicated by the dotted line. The regulator is out of the circuit. The actual switch position is shown to the immediate left, while the schematic shows the NBS in the top left of the schematic. BRIDGING POSITION CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved The NBS bypass switch is shown here in the bridging position. Notice that the blade is in contact with the bridging contact before breaking contact with the female clip. The impedance of the series winding and the NBS current limiting resistors eliminate the high circulating current in the series winding. The bridged connection between bridging contact and the female clip insures uninterrupted service. INTERMEDIATE POSITION The NBS bypass switch is shown here in the intermediate position. Notice that the blade is in contact with the bridging contact, only. The impedance of the NBS current limiting resistors solely eliminates the high circulating current in the series winding. These resistors are lab and field proven to withstand 600 Amps during the transfer operation. CUT-IN POSITION The NBS bypass switch is shown here with the regulator now in service. The blade contacts the female clip while still on the bridging contact. This provides uninterrupted service to the customer. Interruption of voltage can cause magnetic contactors in large motors to drop out, thus requiring restarts. 4.13

15-38 kv NBS One Pole 10 Arm Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: NBS, 15-38 kv, One Pole (10 Arm), Hookstick Dimensions Drawing No.: Revision: 9216-47R-2M 00 4.20

15-38 kv NBS Two Pole Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: NBS, 15-38 kv, Two Pole (10 Arm), Hookstick Dimensions Drawing No.: Revision: 9216-48-1M 00 4.21

15-38 kv NBS Three Pole Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: NBS, 15-38 kv, Three Pole, Hook-stick Dimensions Drawing No.: Revision: 9216-51M 00 4.22

15-38 kv NBS Three Pole H-Frame Recip. Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: NBS, 15-38 kv, Three Pole H-Frame, Reciprocating Dimensions Drawing No.: Revision: 9216-17-2M 00 4.23

15-38 kv NBS Three Pole H-Frame Hookstick Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: NBS, 15-38 kv, Three Pole H-Frame, Reciprocating Dimensions Drawing No.: Revision: 9610-25M 00 4.24

LineBOSS GBS 15 kv - 69 kv Sidebreak Type, Fused/Grounding Switch Specialty Switch The LineBOSS loadbreak grounding switch, GBS, is uniquely designed to provide loadbreak, open gap clearances and line grounding for applications in substations or pole line switches. The GBS is available for two arm substation construction with switch bases manufactured to adapt to existing structures, or factory unitized on a single steel crossarm. The GBS is available with fused disconnects for additional system safety requirements. Control mechanisms are built with safety key interlocks to prevent the isolator (loadbreak) switch and the grounding switch from errant closure of both switches. CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved STANDARD FEATURES Continuing the INERTIA LineBOSS product line, the GBS is made to ANSI and Inertia standards to provide the most rugged switch available with the following features: Solid platform with a 1/4 thick steel base All ferrous components are hot dip galvanized Insulators are station post insulators either silicone or porcelain with 3 bolt circle All components in the current path through the switch are substation grade copper, silver-plated throughout Terminal pads are tin-plated for compatibility with all types of commonly used connectors copper, tinned copper, aluminum, bronze etc.) Contact clips are reverse loop design for greater contact force during high momentary currents Loadbreak options from arc whips, AmpRupter expulsion tube interrupter and the AmpVac vacuum bottle interrupters. The GBS shares all of the features of the LineBOSS conventional sidebreak switch. See LineBOSS LBS Features & Benefits for additional information. SWITCH RATINGS: Voltage Class: 15 kv, 25 kv, 35 kv, 46 kv & 69 kv Continuous Current Class: 600 A, 900 A & 1200 A STANDARD CONFIGURATIONS Pole mounted for distribution applications Frame mounted for substation applications 4.50

LineBOSS Fused/Grounding Switch Selection Guide LineBOSS TM Unitized Gang Switch Fused Grounding Switch Fused Switch Grounding Switch For Increased Corrosion Resistance: Add T for ARMORGALV Voltage Class: 15.5 kv (110 kv BIL) = 1 25.8 kv (150 kv BIL) = 2 38.0 kv (200 kv BIL) = 3 48.0 kv (250 kv BIL) = 4 72.5 kv (350 kv BIL) = 5 Current Rating: 600 A = 6 900 A 1 = 6 900 A 2 = 9 1200 A = 1 Insulator Type: Polymeric Silicone 3 = S Porcelain 3 = P For Increased Insulator Creepage: Add 1 for +1 voltage class Add 2 for +2 voltage class Interrupter Type: Amprupter, Loadbreak 3 = L ArcWhip, Quick-break 3 = Q Vacuum: 38 kv = V3 48 kv = V4 72.5 kv = V7 No Interrupter = X 1 900 A (Temp Rise: 30 C Momentary: 40 ka) 2 900 A (Temp Rise: 30 C Momentary: 51 ka ANSI) 3 Voltage Class: 15.5 to 48.0 kv = 3.0 BC, 72.5 kv = 5.0 BC FG16SLSH1123+SXXX = FG = F = G Crossarm Type: Aluminum = A Fiberglass = F Galv. Steel = S No Xarm = X Customer specified loading (call factory). Mounting Configuration: Horizontal Center Mount = C Horizontal Upright = H Riser = R Underarm Horizontal = U Add G for 36 Climbing Space Add S for Substation (H-Frame) See Substation/H-Frame Chart. Version Current Rating Fuse Type: SM = S Specify Mfg. and Model #. Control Rod Length: 30 ft. (Standard) = 3 Specify (10 Sections) = See Options Chart for insulated section. Control Location: Specify the quadrant by number, where the control is to be located. See Control Options Chart. Control Rod Type: Reciprocating ( ) 1-3/4 Square Fiberglass = 1 1 Round Fiberglass = 2 3/4 Galvanized Pipe = 3 1 Galvanized Pipe = 4 Torsional ( ) 1 1/2 Galvanized pipe = 6 Control Mechanism: Reciprocating Handle ( ) = 1 Torsional handle ( ) = 2 Note: Consult the factory for any options not listed, including; arrestors, sensors, support brackets etc.. LineBOSS Standard Configurations Single Phase Grounding Switch 2 Hole NEMA Pad Isolator Switch Grounding Lug Interrupter Loadbreak Grounding Switch Power Fuse Single Phase Fused Grounding Switch Optional Grounding Switch Earth Grounding Lugs ArcWhip Load Break Device Isolator Switch 2 Hole NEMA Pad CAT040930H 2016 Inertia Engineering & Machine Works, Inc. Printed XX/XX All rights reserved 4.50.1

38 kv Horizontal Underarm Grounding Switch Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: NTS Description: 38 kv Horizontal Underarm Grounding Switch Dimensions Drawing No.: Revision: 9330-13M 00 4.51

38 kv Fused Grounding Switch Dimensions CAT170119I 2017 Inertia Engineering & Machine Works, Inc. Printed 01/17 All rights reserved This drawing is for illustrative purposes only and therefore; may, or may not reflect the current revision of this drawing. Please request the current revision from the factory upon quote. Materials: Finish: Scale: Drawn By: Date: MINIMUM PHASE SPACING Voltage Rating Dim A Dim B Dim C Dim D Dim E 15 kv 20 66.5 36 62.5 12 25 kv 24 72.5 36 68.5 16 38 kv 28 86 48 82 20 NTS Description: Fused Grounding Switch (38 kv), ArcWhip, Recip. Ctrl., Dimensions Drawing No.: Revision: 6400GM 02 4.52