P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control

Similar documents
Variable Frequency Drive / Inverter (0.4 ~ 280kW)

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

E3 Adjustable Speed Drive Engineering Specification

Fan and Pump AC Inverter

S11 Adjustable Speed Drive Engineering Specification

ADJUSTABLE SPEED DRIVES. AS1 Drive

VF-nC1 Adjustable Speed Drive Engineering Specification

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

TOSVERT TM VF-nC3 Parameter List

ACH550 HVAC Drive Submittal

SX (400 V) System configuration

Inverter Drive /Vector Drive Motors & Controls

ADJUSTABLE SPEED DRIVES. HX7 Series. 18 Pulse. Phone: Fax: Web: -

SX (690 V) System configuration

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

ADJUSTABLE SPEED DRIVES VF-S11 Sords Electric

Manual Overview...1 2

BACnet- MS/TP COMMUNICATION V

ADJUSTABLE SPEED DRIVES FS1

ADJUSTABLE SPEED DRIVES. W7 Series. 18 Pulse

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

SX (400V) System configuration

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

SJ700 series High performance with Many useful Functions and, yet User Friendly. WJ200 series Pursuing the Ideal Compact Inverter NEW

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Medium Voltage VFD. Perfect Energy Saving Drive 3kV 200kVA ~ 3,700kVA / 4kV 250kVA ~ 4,700kVA 6kV 400kVA ~ 7,500kVA / 10kV 600kVA ~ 11,000kVA

RSi SG Series Sensorless Vector Variable Frequency Drive

PowerFlex 400 Submittal

AF91 Adjustable Frequency Drives Series B

FUJI Inverter. Standard Specifications

Design Specifications Operator Keypad Environmental and Operating Conditions

ADJUSTABLE SPEED DRIVES. HX7 Series. 18-Pulse

PowerFlex 400 AC Drive Guide Specification

High on efficiency big on reliability AC Drive for Fans & Pumps

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

WJ200 series Pursuing the Ideal Compact Inverter

Phoenix DX Clean Power (18 Pulse) AC Drive

Thank you for purchasing FCS (Franklin Control Systems former Cerus) VFD SAFETY INSTRUCTIONS

P Series. Installation, Programming Operation, & Maintenance Manual. Fan & Pump Optimized Variable Frequency Drive.

SJ series P1 High performance inverter with innovative ease-of-use and excellent driving performance

6.9 Jump frequency - Avoiding frequency resonance

Version number A=standard P=Cold Plate (Frame A only) T=Brake chopper (Frame A only) Input voltage 11=115VAC 21=230VAC 1φ 23=230VAC 3φ 43=400VAC

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

vacon nxs robust drive for heavy use

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

AV-300i Specifications. GE Industrial Systems. Product Specifications. A New Concept in Automation. AV-300i

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

ROLL TO ROLL FUNCTION MANUAL FR-A (0.4K)-04750(90K)-R2R FR-A (0.4K)-06830(280K)-R2R FR-A (315K)-12120(500K)-R2R

BOSTON GEAR CONTROLLERS. ACE 20 Series 1/8 through 10 HP Adjustable Frequency AC Motor Controllers. MTY (81)

Product description. At a glance. Customer benefits

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

GS1 Parameter Summary Detailed Parameter Listings...4 9

Micro and Mini Inverters

9. RS485 Communication

NX Series Inverters. HVAC Pocket Programming Guide

SAFETY INSTRUCTIONS. After reading this manual, keep it in the place that the user always can contact easily.

General Specifications FECA-TE /2010. Phone: Fax: Web:

The new Yaskawa Varispeed G7 Inverter

A700 Series. Variable Frequency Drives UNSURPASSED POWER AND CONTROL 1 /2-700 HP

Power Regenerative Converter, THYFREC CV240S

CTi Automation - Phone: Fax: Web: -

VFS11 Parameter List for up to CPU version 105

INTER PLANT STANDARD STEEL INDUSTRY VARIABLE VOLTAGE VARIABLE FREQUENCY SYSTEM (V.V.V.F.) V/F, VECTOR CONTROL / TORQUE CONTROL

Installation, Programming Operation, & Maintenance Manual V

General Purpose AC Drives

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

INTERNATIONAL SERVICE BULLETIN - I #2-319 Liberty - Delta M+ VFD parameter list. A VFD parameter list is required when replacing a DELTA M+ VFD.

13. Before making a service call Trip information and remedies

General Purpose Drives

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Before you operate the inverter, the parameters that you must first program are the basic parameters.

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

9. RS485 Communication (Option)

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

SECTIONS , (15040, 15767, 15950, 16269) Guide Specification for VARIABLE SPEED DRIVES with Optional Bypass

TECHNICAL SPECIFICATION INVERTER VEGA DRIVE

Frequency Inverters. SJ700B Series. Powerful Inverter for General Purpose Use. SJ700B Series

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

Global standard ic5, serves a wide variety of applications to meet the majority of user needs.

GB QUICK GUIDE FOR THE CONFIGURATION OF VARIABLE SPEED DRIVES

CHAPTER 8 PARAMETER SUMMARY

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

This Chapter contains:

Based on experience Backed by commitment

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

NEWPCC VARIABLE FREQUENCY DRIVES Section LAB RENOVATION BID OPPORTUNITY NO PAGE 1 OF SCOPE

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

PRODUCT OFFERING ADJUSTABLE SPEED DRIVES

Warning!! 2. The drive contains high voltage that can cause electric shock resulting in personal injury or loss of life.

A700 Series. Variable Frequency Drives

LG Variable Frequency Drive

HPVFP High Performance Full Function Vector Frequency Inverter

Industrial Inverter for Fan and Pump. STARVERT ip5a. 5.5~30kW(7.5~40HP) 3Phase 200~230Volts 5.5~450kW(7.5~600HP) 3Phase 380~480Volts.

3. Be aware of the ambient temperature. Use the unit within the specified ambient temperature only.

This operation manual is intended for users with basic knowledge of electricity and electric devices.

Rexroth Frequency Converter Fe 0.75 kw to 7.5 kw / 400 VAC

Transcription:

P-SERIES VFD 1-40HP (200~230VAC), 1-400HP (380~480VAC),3Ø Dual Rated for Constant & Variable Torque Integrated PID Control NEW FIRMWARE MAKES SETUP A SNAP Application based commissioning allows parameters to be automatically set based on industry standards Applications: Basic, circulating pump, supply fan, exhaust fan or cooling tower Selectable units include PSI, F, C, inwc, inm, Bar, mbar, Pa, kpa Belt loss protection SPACE VECTOR CONTROL FOR EFFICIENCY AND LONG MOTOR LIFE Cleaner sine wave as compared to typical V/Hz control. Motors run cooler and last longer ADVANCED PID CONTROL (PRE-PID AND DUAL PID) Maintain a constant control of pressure, flow or water level. This function includes Pre-PID, Sleep and Wake up and output inverse sub-functions Dual PID for external PID control or cascade PID control Multi-Motor MULTI-MOTOR CONTROL FUNCTION Control up to 4 motors AUTOMATIC ENERGY SAVINGS MODE Adaptive flux control for varying loads (e.g. damper loading) SLEEP AND WAKE UP FUNCTION Increased energy savings by deactivating drive during low demand The 32-character backlit LCD screen displays the drive s operational status and parameter settings. A very easy drive to set up. FLYING START PROTECTION Prevents trips, rough starts, and drive damage from regenerative power from heavy fan inertia rotation BUILT-IN MODBUS RTU COMMUNICATION Optional: Profibus-DP, LonWorks, BACnet BACnet is a registered trademark of ASHRAE.

PRE-HEATER FUNCTION Used to protect motor and inverter from damage when installed in damp location (e.g. green house). AUTOMATIC CARRIER FREQUENCY CHANGE Adjusts based on temperature for optimal operation SELECTABLE V/F, SENSORLESS VECTOR CONTROL Ideal for any control requirement The P-Series clearly marked terminal inputs and outputs allow for easy wiring and setup. LONG-LIFE CONDENSER & SIMPLE FRAMEWORK Increased reliability Perfect for fans, pumps and airhandlers. Specifications Output ratings Input ratings Operation Input signal Output signal Protective functions Operating environment Voltage (V) Three phase, 200~230V, Three phase, 380~480V Frequency (Hz) 0~120Hz Voltage (V) Three phase, 200~230V (-15%, +10%), Three phase, 380~480V (-15%, +10%) Frequency (Hz) 50~60Hz (±5%) Input Power Factor <.95 from no load to full load Drive Efficiency >96% Control method V/F control, Sensorless vector control Frequency setting resolution Digital reference: 0.01Hz (below 99Hz) & 0.1Hz (100Hz and over); Analog reference: 0.06Hz at 60Hz Frequency setting accuracy Digital: 0.01% of maximum output frequency; Analog: 0.1% of maximum output frequency V/F ratio Linear, Square, User V/F Overload capacity 1 minute at 120%, 10 seconds at 150% (with inverse characteristic proportional to time) Torque boost Auto, Manual (0~15%) Multi-function input terminals Total 8 inputs (programmable) Analog output 0~10V linear Operator control 32-character LCD keypad, Terminals, ModBus-RTU communication Optional, ProfiBus-DP, DeviceNet, F-Net, BACnet, LonWorks Frequency setting Analog: 0~10V, 4~20mA, additional port for Sub-Board (0~10V); Digital: Keypad, Communication Start signal Forward, Reverse Multi-step operation Setting up to 17 speeds (using multi-function terminal) Multi-step accel/decel time Operational functions 0.1~6000 seconds. Maximum 8 pre-defined steps using multi-function terminals DC braking, Frequency limit, Frequency jump, Second motor function, Slip compensation, Reverse rotation prevention, Auto restart, Inverter bypass, Auto-tuning, Dual PID control Emergency stop Stops output from inverter Auto operation Operates from internal sequence by setting multi-function terminal (5 way x 8 step) Jog Jog operation Fault reset Resets fault signal when protective function is active Operational status Frequency detection, Overload alarm, Stall, Overvoltage, Undervoltage, Inverter overheat, Run, Stop, Constant speed, Speed search, Fault output, Inverter bypass, Auto-operation sequence Indicator Output frequency, Output current, Output voltage, DC voltage, Output torque (output voltage: 0~10V) Trip Overvoltage, Undervoltage, Overcurrent, Inverter overheat, Motor overheat, I/O phase loss, Fuse open, Ground fault, External fault 1, 2, Option fault, Overload, Speed command loss, Hardware fault, Communication error, etc. Alarm Stall, Overload Temperature sensor fault Ambient temperature -10 ~40 C (50 C when derated 20%) or 14 ~104 F (122 F when derated 20%) Storage temperature -20 ~65 C or -4 ~149.5 F Humidity Less than 95% Relative Humidity maximum (non-condensing) Vibration Below 5.9m²/sec (=0.6g) Altitude Below 1,000m (3,300ft): Derate VFD by 10% for every additional 1,000m Application site Pollution degree 2. No corrosive gas, combustible gas, oil mist or dust

P-SERIES WIRING *For general reference only, not field wiring. Consult installation instructions.

Options CI-RKPK-EXT2M-P/S CI-RKPK-EXT3M-P/S CI-RKPK-EXT5M-P/S CI-R4-COM CI-BN-COM CI-LWP-COM CI-N2-COM Description Remote Keypad Mounting Kit (2 Meter Cable) Remote Keypad Mounting Kit (3 Meter Cable) Remote Keypad Mounting Kit (5 Meter Cable) RS485 communication card BACnet communication card Lonworks communication card N2 communication card 3-Phase, 200~230V P-Series VFD Standard Duty (VT) Heavy Duty (CT) HP kw FLA HP kw FLA 3% Line Reactor* 1 1.9 5 0.4 0.95 2.5 CI-001-P2 KDRULA25LE01 2 3 8 0.75 1.9 5 CI-002-P2 KDRULA27LE01 3 4.6 12 1.5 3 8 CI-003-P2 KDRULA28LE01 5 6.1 16 2.2 4.6 12 CI-005-P2 KDRULB22LE01 7.5 5.5 24 5 3.7 17 CI-007-P2 KDRULB23LE01 10 7.5 32 7.5 5.5 23 CI-010-P2 KDRULD25LE01 15 11 46 10 7.5 33 CI-015-P2 KDRULD24LE01 20 15 60 15 11 44 CI-020-P2 KDRULD26LE01 25 18.5 74 20 15 54 CI-025-P2 KDRULC22LE01 30 22 88 25 18.5 68 CI-030-P2 KDRULF24LE01 40 30 115 30 22 84 CI-040-P2 KDRULF25LE01 3-Phase, 380~480V P-Series VFD Standard Duty (VT) Heavy Duty (CT) HP kw FLA HP kw FLA 3% Line Reactor* 1 2 2.5 0.4 1 1.25 CI-001-P4 KDRULA8LE01 2 3.2 4 0.75 2 2.5 CI-002-P4 KDRULA1LE01 3 4.8 6 1.5 3.2 4 CI-003-P4 KDRULA2LE01 5 6.4 8 2.2 4.8 6 CI-005-P4 KDRULA3LE01 7.5 5.5 12 5 3.7 8 CI-007-P4 KDRULA4LE01 10 7.5 16 7.5 5.5 11 CI-010-P4 KDRULA5LE01 15 11 24 10 7.5 17 CI-015-P4 KDRULB2LE01 20 15 30 15 11 22 CI-020-P4 KDRULB1LE01 25 18.5 39 20 15 28 CI-025-P4 KDRULD1LE01 30 22 45 25 18.5 34 CI-030-P4 KDRULD2LE01 40 30 61 30 22 44 CI-040-P4 KDRULC1LE01 50 37 75 40 30 55 CI-050-P4 KDRULF2LE01 60 45 91 50 37 66 CI-060-P4 KDRULF4LE01 75 55 110 60 45 80 CI-075-P4 KDRULF3LE01 100 75 152 75 55 111 CI-100-P4 KDRULH3LE01 125 90 183 100 75 134 CI-125-P4 KDRULH2LE01 150 110 223 125 90 183 CI-150-P4 KDRULH1LE01 200 132 264 150 110 223 CI-200-P4 KDRULG3LE01 250 160 325 200 132 264 CI-250-P4 KDRULG1LE01 350 220 432 250 160 325 CI-350-P4 KDRULJ2LE01 400 280 547 300 220 432 CI-400-P4 KDRULJ1LE01

P-SERIES DIMENSIONS *ALL MEASUREMENTS IN INCHES C A B P-Series Drive H x W x D, (A x B x C) CI-007-P2 11.19 x 5.91 x 6.17 CI-007-P4 CI-010-P2 CI-010-P4 11.18 x 7.87 x 7.16 CI-015-P2 CI-015-P4 CI-020-P2 CI-020-P4 15.16 x 9.84 x 7.94 CI-025-P2 CI-025-P4 CI-030-P2 CI-030-P4 18.11 x 11.97 x 9.22 CI-040-P2 CI-040-P4 CI-050-P4 20.28 x 11.81 x 10.46 CI-060-P4 CI-075-P4 20.28 x 11.81 x 11.52 CI-100-P4 23.09 x 14.57 x 13.29 CI-125-P4 CI-150-P4 30.26 x 20.80 x 16.64 CI-200-P4 CI-250-P4 33.23 x 20.80 x 16.64 CI-350-P4 41.85 x 21.17 x 17.70 CI-400-P4 CI-500-P4 43.7 x 30.8 x 17.4 CI-600-P4 51.3 x 36.3 x 19.5 CI-700-P4