Virtual Laboratory of Nuclear Fission Virtual practicum in the framework of the project Virtual Laboratory of Nuclear Fission

Similar documents
Method for digital particle spectrometry Khryachkov Vitaly

Fast first practical help -- detailed instructions will follow- preliminary Experiment F80

Energy Measurements with a Si Surface Barrier Detector and a 5.5-MeV 241 Am α Source

INDEX. Firmware for DPP (Digital Pulse Processing) DPP-PSD Digital Pulse Processing for Pulse Shape Discrimination

--- preliminary Experiment F80

ORTEC. Research Applications. Pulse-Height, Charge, or Energy Spectroscopy. Detectors. Processing Electronics

The software and hardware for the ground testing of ALFA- ELECTRON space spectrometer

K 223 Angular Correlation

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

PHYSICS ADVANCED LABORATORY I COMPTON SCATTERING Spring 2002

Physics Laboratory Scattering of Photons from Electrons: Compton Scattering

Instructions for gg Coincidence with 22 Na. Overview of the Experiment

1 Purpose of This Lab Exercise:

Stage B: Allo scoperta del nucleo atomico: l esperimento di Rutherford. Stage C: Informatica e fisica sperimentale

CAEN Tools for Discovery

Traditional analog QDC chain and Digital Pulse Processing [1]

NEEP 427 PROPORTIONAL COUNTERS. Knoll, Chapters 6 & 14 Sect. I & II

Gamma Spectrometer Initial Project Proposal

Electronic Instrumentation for Radiation Detection Systems

PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5)

arxiv:hep-ex/ v1 8 Jul 1999

Radiation Detection Instrumentation

Range of Alpha Particles in Gas (note, this is abridged from full Nuclear Decay laboratory file)

GAMMA-GAMMA CORRELATION Latest Revision: August 21, 2007

Silicon Photomultiplier Evaluation Kit. Quick Start Guide. Eval Kit SiPM. KETEK GmbH. Hofer Str Munich Germany.

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

CAEN. Electronic Instrumentation. CAEN Silicon Photomultiplier Kit

Advanced Materials Research Vol

e t Development of Low Cost γ - Ray Energy Spectrometer

Partial Replication of Storms/Scanlan Glow Discharge Radiation

Spontaneous Fission Spectrum of Neutrons from 252 Cf with Kinetic Energies Less than 1 MeV. Suraj Bastola. A senior thesis submitted to the faculty of

Recommissioning the Qweak Drift Chambers Using a Cosmic-Ray Telescope

Mössbauer ~ Spectrometer. Following to our long-term experiences, we offer complete Mössbauer spectroscopy instrumental support

The Influence of Crystal Configuration and PMT on PET Time-of-Flight Resolution

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

OPERATING CHARACTERISTICS OF THE GEIGER COUNTER

CC2 Charge Sensitive Preamplifier: Experimental Results and Ongoing Development

Week 11: Chap. 16b Pulse Shaping

Calibrating Radioactive Monitors

On the initiation of lightning in thunderclouds (Instrumentation, Supplementary information)

A Modular Readout System For A Small Liquid Argon TPC Carl Bromberg, Dan Edmunds Michigan State University

ORTEC Experiment 13. Gamma-Gamma Coincidence with Angular Correlation. Equipment Required

Development of LYSO detector modules for a charge-particle EDM polarimeter

SPECTROMETRIC DETECTION PROBE Model 310. Operator's manual

LIFETIME OF THE MUON

Study of Silicon Photomultipliers for Positron Emission Tomography (PET) Application

Backgrounds in DMTPC. Thomas Caldwell. Massachusetts Institute of Technology DMTPC Collaboration

Atomic and Nuclear Physics

DEVELOPMENT OF HIGH STABLE MONITOR FOR MEASURERING ENVIRONMENTAL RADIATION

Physics 342 Laboratory. Scattering of Photons from Free Electrons: Compton Scattering

Data Compression and Analysis Methods for High- Throughput Radiation Detector Systems

ORTEC Experiment 1. Introduction to Electronic Signal Analysis in Nuclear Radiation Measurements. Equipment Required: Purpose. Electronic Circuits

7. Experiment K: Wave Propagation

Time of Flight Measurement System using Time to Digital Converter (TDC7200)

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

CONTROL AND READOUT ELECTRONICS OF THE TIME- OF-FLIGHT SYSTEM OF THE MPD

Large Area Continuous Position Sensitive Diamond Detector: First tests

Measurements of MeV Photon Flashes in Petawatt Laser Experiments

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory

Product Range Electronic Units

Purpose This experiment will use the coincidence method for time correlation to measure the lifetime in the decay scheme of 57

An ASIC dedicated to the RPCs front-end. of the dimuon arm trigger in the ALICE experiment.

Radiation Test Report Paul Scherer Institute Proton Irradiation Facility

COMPTON SCATTERING. Purpose. Introduction. Fundamentals of Experiment

SPECTRA 5011, SPECTRA 5041 PORTABLE ALPHA-BETA-GAMMA SURFACE INVESTIGATOR SURFACE INVESTIGATOR PRO SPECTROMETER

Physics Experiment N -17. Lifetime of Cosmic Ray Muons with On-Line Data Acquisition on a Computer

Digital Signal Processing for HPGe Detectors

Experiment 10. The Speed of Light c Introduction Apparatus

ORTEC ORTEC. Modular Pulse- Processing Electronics. What s in this Catalog? Who Needs this Catalog?

Positron Emission Tomography

Amptek sets the New State-of-the-Art... Again! with Cooled FET

Ensuring Shielding adequacy in Lead shielded spent fuel transportation casks using gamma scanning

ORTEC. AN34 Experiment 14 Nuclear Lifetimes and the Coincidence Method. Equipment Needed from ORTEC. Equipment Required from Other Manufacturers

Readout electronics of silicon detectors used in space cosmic ray charges. measurement

Main Detectors for PREX and CREX

Cosmic Rays in MoNA. Eric Johnson 8/08/03

SECOND HARMONIC GENERATION AND Q-SWITCHING

INSTRUMENTATION BREADBOARDING (VERSION 1.3)

and N(t) ~ exp(-t/ ),

National 4. Waves and Radiation. Summary Notes. Name:

ORTEC Experiment 3. Gamma-Ray Spectroscopy Using NaI(Tl) Equipment Required. Purpose. Gamma Emission

MICOD CHARGE SENSITIVE AMPLIFIER CSA-250

Mass Spectrometry and the Modern Digitizer

XRF Instrumentation. Introduction to spectrometer

Today s Outline - January 25, C. Segre (IIT) PHYS Spring 2018 January 25, / 26

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

AMS-02 Anticounter. Philip von Doetinchem I. Physics Institute B, RWTH Aachen Bad Honnef, August 2007

Chemistry 985. Some constants: q e 1.602x10 19 Coul, ɛ x10 12 F/m h 6.626x10 34 J-s, c m/s, 1 atm = 760 Torr = 101,325 Pa

Photoelectric effect

PHY 123/253 Shot Noise

Diamond sensors as beam conditions monitors in CMS and LHC

AMPTEK INC. 14 DeAngelo Drive, Bedford MA U.S.A FAX:

Real Time Pulse Pile-up Recovery in a High Throughput Digital Pulse Processor

Nuclear Associates

Applying Virtual Oscilloscope to Signal Measurements in Scintillation Detectors

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

Design of the High Voltage Supply Module of a Prototype Energy Spectrometer for Solar Wind Plasma Measurement

- Nuclear Radiation Sensor - Detects Beta and Gamma Radiation and X-Rays

Nuclear Experiment Phys 318/317 Room 208 Instructor Richard Lindgren Room 302 Ext

Transcription:

Virtual Laboratory of Nuclear Fission Virtual practicum in the framework of the project Virtual Laboratory of Nuclear Fission Khanyisa Sowazi, University of the Western Cape JINR SAR, September 2015

INDEX Study of signals from a pulse generator Signal measurements from a semiconductor detector by the use of the oscilloscope Work with the signals from the PIN diode Calibration from the precision pulse generator Work with the CAMAC slave controller. Study of a register module

Study of signals from a pulse generator We use generator to create pulses on the oscilloscope. From there we can measure the amplitude and duration of each signal on the oscilloscope. We measure the length of any wire by putting a wire of known length on one channel and the unknown on another channel and then measure the time delay. The signal propagation velocity in the cable is 5 nanoseconds per meter

Signal measurements from a semiconductor detector by the use of the oscilloscope

We use Cf-252 as our radioactive source and the signal is read by a semiconductor detector. Since the signal generated is on the Nano-ampere scale, we use a high voltage source to amplify the signal. After amplification our oscilloscope can now read the signal and hence we can now do our physics. If the voltage is high enough you should be able to observe two signals, one from alpha decay and the other from fission.

Work with the signals from the PIN diode Now here we use CAMAC which has in it a HV generator, modulator, amplifier, QDC and Intelligent Crate Controller. Signals are generated as spectra with all the different amplitudes(volts) and number of signals(counts). We can modulate the gap between each signal by adjusting the amplifier until we get a satisfying spectra. Each channel corresponds to energy, so by analyzing at which channel the peak is, you will get the energy and hence what type of particle is emmitted.

Calibration from the precision pulse generator For calibration we use a signal generating amplifier, QDC(Charge-to-Digital- Converter) and intelligent crate controller connected a the computer. We run a few signals from 10 millivolts, moving in steps of ten and see what channels they correspond to. We then make a plot of amplitude(mv) against the number of channels and should have the relationship y = ax + b. Calibration coefficient is 0.0468 and the intercept is 0.3509

Work with the CAMAC slave controller. Study of a register module CAMAC(Computer Automated Measurement And Control) is a control and data acquisition system based on Crates and Modules. It is a crate with 25 slots in which modules are inserted including a control crate. We can choose which slot(station) we read from by adjusting the crate controller which is usually at the top right of the CAMAC crate.

Register module.

Virtual Laboratory of Nuclear Fission Studying of radioactivity and cosmic rays using scintillation detectors Ndivhuwo Ndou, University of Venda JINR SAR, September 2015

Purpose Preparation of the experimental material for the development of new virtual practical works for the project Virtual Laboratory of Nuclear Fission

Measurements of signals from a scintillation detector

Scintillation detector scheme

ADC calibration from the precision amplitude generator

Obtaining of the amplitude spectrum from the NaI detector 40 K E = 1416 kev

Obtaining of the amplitude spectrum from the NaI detector with radioactive source Source: 85Strontium + 88Yttrium 514 kev 898 kev 40 K 1836 kev Radioactive source

Data analysis of spectra in ROOT

Data analysis of spectra in ROOT 1416 kev ( 40 K) 514 kev Expected gamma Potassium lines from 898 kev gamma-line from radioactive source 1836 kev NaI impurity

Work with the scintillation telescope

Conclusion The experimental material for 2 new virtual practicum works for the project Virtual Laboratory of Nuclear Fission was prepared: 1. Work with scintillation detectors 2. Scintillation telescope: study of cosmic rays

Virtual Laboratory of Nuclear Fission LISSA training: measurements of thin foil thicknesses by the use of the radium-226 alpha source Ndinannyi Justice Mukwevho, University of the Western Cape JINR SAR, September 2015

THE MAIN AIM OF THE EXPERIMENT The main aim of the experiment was to measure the thicknesses of the foils by the use of radium 226 alpha source.

DETECTOR HOLDER WITHOUT A FOIL The radium source emits alpha particle which is detected in the PIN diode. The primary function of a preamplifier is to extract the signal from the detector.

DETECTOR HOLDER WITH A FOIL The radium source emits alpha particle which passes through the foil and detected in the PIN diode.

EXPERIMENTAL SETUP This is the picture showing the experimental setup and the equipment used is vacuum chamber, preamplifier, vacuum station, 226Ra source, Foil (the material of the foil is polycarbonate), CAEN flash-digitizer and PC with data collecting software.

Counts 4.784MeV SPECTRA WITHOUT THE FOIL 5.489MeV 7.687MeV 6.002MeV We calibrate by finding a relationship between energy and channels. We start by putting a source of radiation with no foil in-between it and the detector. We get 4 peaks as in the diagram. We find the center of mass for each peak by finding their mean. We found the energies of the four peaks on literature and plot a function of energies against the mean channel values. The slope of the graph is the calibration coefficient we use for converting from channel to energy. We also add the intercept when converting. Channel N

CALIBRATION OF SPECTROMETER The calibration graph is represented by a straight line. The data was analyzed by using the relation y = ax + b The coefficient of straight line slope (Calibration coefficient) is 0.0263

Counts SPECTRA WITH THE FOIL We again measure the channel for the four peaks by finding the mean value for each peak. We use our calibration equation (y = ax + b) to get the precise energy for all the peaks. The particle loses some of its energy when passing through the foil. The spectra shifted to the left because of energy loss Channel N

CALCULATION OF THICKNESS OF THE FOIL USING SRIM (Stopping and Range of Ions in Matter) SRIM software was used to calculate the thickness of the foil. SRIM is the software that can be used to simulate the interaction of particles with matter

Calculation of thickness of the foil using the Stopping and Range of Ions in Matter (SRIM) software

Table 1 : shows the thickness of different foils Energy without foil = 7.687 MeV No. of foil Energy after passing foil (MeV) 1 7.630 7200 Thickness(Å) 2 7.630 7200 3 7.745 4820 4 7.601 11300

GRAPH OF ENERGY (MeV) vs. THICKNESS(Å) The obtained graph has a linear form The coefficient of straight line slope is -7.70226E-6 This graph shows that the thicker the foil, the lesser the energy of the alpha particle after passing the foil SO OUR EXPERIMENT WAS STABLE

Virtual Laboratory of Nuclear Fission Data analysis of LIS spectrometer signals from 5 GS/s Switched Capacitor Digitizer. Kehinde Gbenga Tomiwa, University of the Witwatersrand JINR SAR, September 2015

Experimental setup Determination of particle time of flight of particle Source Apparatus: Pin Diode detector (measures energy and time of flight) Time Stamp detector based on Microchannel plate (measures time of flight) Source Califonium-252 with Plutonium-238 Emits Alphas and fission fragments Start signal Detector signal

Analysis of signal Root/C++: Analysis flow Draw shape of the signals Event-by-Event Revert Spectra Fit Pedestal (find baseline) and Smooth Signal Data input: Binary data from Start-TD and PIN diode detector Number of Events: 14533 Filter event based on amplitude distribution Determine the Timestamp (TS) for each channel TOF = TSPin Dec -TSStart Dec

Detectors signal Spectra TS1 TS2 TOF threshold

Event Amplitude Distribution Alpha peak 238 Pu Alpha peak 252 Cf Pin Diode Amp. detector Dist. Fission fragments

Detector Spectra y p 0 ts? Fit on Signal pedestal p0 Fit on Signal rise Slope (p1) of fit Xbin number(ns) TS1 TS2 TOF Method Draw amplitude distribution of all event. Define Start signal threshold to filter events Fit signal pedestal and rise time to obtain baseline and slope. Estimate ts for start and pin diode detector event by event

Time of Flight Distribution Alpha peak 252 Cf Alpha peak 238 Pu Fission fragments

Summary Data from LIS experimental setup was analysed Start detector signal threshold was defined Filter event based on the signal amplitude distribution Time-stamp of signals was estimated Time of flight of particles was esytimated event by event

Thank you!