Balanced Armature Check (BAC)

Similar documents
Measurement at defined terminal voltage AN 41

Meta-Hearing Defect Detection

Measurement of Weighted Harmonic Distortion HI-2

Production Noise Immunity

3D Distortion Measurement (DIS)

Measurement of weighted harmonic distortion HI-2

Measurement of Amplitude Modulation AN 6

Causes for Amplitude Compression AN 12

Dynamic Generation of DC Displacement AN 13

Linear parameters. Mechanical Parameters (using laser)

QC Software Feature Overview

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

Rub & Buzz Detection with Golden Unit AN 23

Maximizing LPM Accuracy AN 25

3D Intermodulation Distortion Measurement AN 8

TBM - Tone Burst Measurement (CEA 2010)

Tolerances of the Resonance Frequency f s AN 42

Transfer Function (TRF)

LST - Linear Suspension Test

klippel qc system 100% end-of-line testing

A R T A - A P P L I C A T I O N N O T E

Linear Lumped Parameter Measurement

Material Parameter Measurement (MPM)

Optimal Voice Coil Rest Position AN 1

Audio System Evaluation with Music Signals

Fast Quality Control of Suspension Parts AN 53

B-Field Scanner. BENEFITS Easy to use Fits to a wide range of voice coil gaps Fully supported by Klippel RnD System Dedicated measurement software

A Guide to Reading Transducer Specification Sheets

The study on the woofer speaker characteristics due to design parameters

Microphones & Accessories

Reduce distortion by shifting Voice Coil AN 21

Fast and Accurate Measurement of Linear Transducer Parameters

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Dayton Audio is proud to introduce DATS V2, the best tool ever for accurately measuring loudspeaker driver parameters in seconds.

Assessing Large Signal Performance of Transducers

Non-linear Digital Audio Processor for dedicated loudspeaker systems

C7: Speaker Components

Practical Impedance Measurement Using SoundCheck

SPEAKER SC-COBRA-WP

DONAU SLIM ENHANCED 11x15x3.0 mm SPEAKER

Introduction of Receivers

Texas Components - Data Sheet. The TX53G1 is an extremely rugged, low distortion, wide dynamic range sensor. suspending Fluid.

Acoustic Measuring System

SPEAKER SC-COBRA-PEEK-WP

High Current, High Power OPERATIONAL AMPLIFIER

Loudspeaker Distortion Measurement and Perception Part 2: Irregular distortion caused by defects

The Woofer Tester Pro. Integrated Speaker Measurement & Design. Web: Phone:

Loudspeaker Data Reliable, Comprehensive, Interpretable

ART500A SPEAKER ART500A A P P L I C A T I O N S 1 O F 6 P A G E S. Two-Way Active Speaker System. ART Series

FREQUENCY RESPONSE AND LATENCY OF MEMS MICROPHONES: THEORY AND PRACTICE

SPECIFICATIONS QW -1. Listen To This. Mid Frequency Section: 101 db SPL, (2 Volt input) High Frequency Section: 111 db SPL, (2.

BETA-8A American Standard Series

MP-1 Microphone Preamplifier User Guide and Technical Information

The Ins and Outs of Audio Transformers. How to Choose them and How to Use them

LAB12 Professional Series

Big Sound from Small Speakers Part 1. Wolfgang Klippel

The CVEN speakers were designed by the Vibe Research and Development team of UK and European engineers headed by company founder Carl Venables.

Measurement of Turbulent Air Noise Distortion in Loudspeaker Systems

THE UNDER HUNG VOICE COIL MOTOR ASSEMBLY REVISITED IN THE LARGE SIGNAL DOMAIN BY STEVE MOWRY

FINEBox T U T O R I A L

Polar Measurements of Harmonic and Multitone Distortion of Direct Radiating and Horn Loaded Transducers

CONTENTS. How to get started FINEQC calibration procedure 3

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Audio Testing. application note. Arrakis Systems inc.

SPA2629LR5H-B. Low Noise Zero-Height SiSonic TM Microphone. The SPA2629LR5H-B is a miniature, highperformance,

MGA Magnetic field system. DC khz

High Stability Voltage Source

Active Compensation of Transducer Nonlinearities. W. Klippel KLIPPEL GmbH, Dresden, Germany

Application Note L26ROY

Loudspeakers. Juan P Bello

FM TRANSMITTERS TESTS

BETA-10A American Standard Series

ViRAY. with DDP Dual Diaphragm Planar-wave-driver Technology. Compact 3-way symmetrical line array system. DDP Technology

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

SW Series Impedance Tube Solutions

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

Overview. Features. Technical Data Sheet 1 / 7. Powered Loudspeaker DSR115

BETA-8A American Standard Series

Vibration Transducer Calibration System

KILOMAX PRO 15A Professional Series

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

INTRODUCTION. the DALI EPICON 6

Overview. Features. Technical Data Sheet 1 / 7. Powered Loudspeaker DSR112

Warning: Power amplifier contain high voltages of several hundred volts. Setup errors can easily damage your health or your equipment.

Microphone Test System

High Power Monolithic OPERATIONAL AMPLIFIER

TS212ac. Self Powered Dual 12 inch Direct-Radiating Subwoofer. product specification. Performance Specifications 1

Measurement of Equivalent Input Distortion. Wolfgang Klippel. Klippel GmbH,Dresden, 01277, Germany, Fellow

BETA-12LTA American Standard Series

evolution wireless G4 ew 112 P G4 Camera Lavalier ME 2 Set ew 122 P G4 Camera Lavalier ME 4 Set

Large Signal Performance of Tweeters, Micro Speakers and Horn Drivers

SPU0409LE5H-QB. Zero-Height SiSonic TM Microphone With Enhanced RF Protection. The SPU0409LE5H-QB is a miniature, highperformance,

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output

easypll UHV Preamplifier Reference Manual

evolution wireless G4 ew 100 G4-ME2 ew 100 G4-ME4 Lavalier Set

SPEAKER SC-DUMBO

High Power Monolithic OPERATIONAL AMPLIFIER

evolution wireless G4 ew 500-G4-MKE 2 Lavalier Set

6 db Differential Line Receiver

DEFINIMAX 4015LF Professional Series

Transcription:

Balanced Armature Check (BAC) S39 Module of the KLIPPEL ANALYZER SYSTEM (QC Ver. 6.1, db-lab Ver. 210) Document Revision 1.1 FEATURES Measure the Armature offset in μm No additional sensor required Ultra-fast testing at physical limit Automatic limit calculation BENEFITS Exploit maximum working range with centered armature Keep distortion low Control production process with offset monitoring Ensure consistency of production Fully ambient noise immune Ready for 100% testing The Balanced Armature Check (BAC) is an add-on for the QC framework of the KLIPPEL Analyzer system. The module measures the offset of the armature and selected linear parameters within an extremely short time (0.5-2 s). A centered armature is required to exploit the full symmetrical working range providing maximal output. Additionally, audible distortion is reduced significantly. Coil Drive rod Diaphragm Magnet 1 Air gap Armature Magnet 2 Pole Piece Output The parameters are easy to interpret and provide feedback for process control to avoid manufacturing bad units. Application: End-of-line testing Incoming goods inspection Diagnostics Prototyping Article Number: 4000-260

Balanced Armature Check (BAC) 1 Overview S39 CONTENTS 1 Overview... 2 2 Definitions... 3 3 Requirements... 4 3.1 Hardware... 4 3.2 Software... 5 3.3 Further Requirements... 5 4 Limits... 6 4.1 Transducer... 6 4.2 Requirements for Power Amplifier... 6 4.3 Input Parameters (Setup)... 6 5 Measurement Results... 7 6 Patents... 7 1 Overview Summary Targets Principle The level of distortion generated by balanced armature transducers depends highly on the rest position of the armature. By shifting the armature to its optimal position, nonlinear distortion can be significantly reduced. A new measurement technique is used which is capable of measuring this offset in a very short time. The knowledge of the offset is useful for controlling manufacturing processes and endof-line-testing, but also for the development of new products. The QC- Balanced Armature Check (BAC) was developed to satisfy the following requirements occurring under production conditions: Measurement of the armature offset within the shortest possible measurement time (0.5 2 s). The parameter supports limit setting and statistics (e.g. cpk, ppk) for assessing the process stability. QC requires a robust and cost-effective hardware solution. The BAC can be operated with the Production Analyzer or KLIPPEL Analyzer 3, which provide current and voltage sensors. No additional sensor is required for BAC. The purely electrical measurement principle provides high robustness against ambient noise. Extremely short training period for the BAC. The armature offset measured with the BAC can be compared with harmonic and intermodulation distortion measurements using the DIS or TRF modules which are modules of the R&D framework of KLIPPEL Analyzer system. In the development process of new products, the effect of the offset on nonlinear distortion can be measured and reasonable limits can be defined for production. The BAC is based on a patent protected identification technique. The loudspeaker is excited by a multi-tone signal of sufficient bandwidth and amplitude. Only electrical signals (voltage and current) are measured at the terminals of the transducer. The armature offset is calculated by exploiting the nonlinear information found in the current signal. For displaying the absolute value of the offset in μm, a mechanical calibration is necessary which is made by means importing the transduction coefficient Tem. KLIPPEL Analyzer System Page 2 of 7

Balanced Armature Check (BAC) 2 Definitions S39 Parameters at x=0 Although the device is operated at higher amplitudes and the inherent nonlinearities produce significant distortion, the parameters at the rest position x=0 can be calculated. Those parameters are comparable with the linear parameters usually measured in the small signal domain. The electrical impedance curve Zel(f) is also measured at the rest position of the armature where the artifacts generated by transducer nonlinearities are suppressed. The BAC uses the Wright inductance model to model inductance behavior reliably. If desired, the simple coil inductance Le which is approximated from the Wright model inductance is provided as well. 2 Definitions Armature Offset X offset DEFINITION: The armature offset is the shift recommendation to compensate the offset relative to the magnetic field. The positive direction of excursion corresponds to the response of the BA excited with positive DC current. The definition is illustrated in Fig. 1. Note that the transduction parameter Tem defines the absolute scaling of the armature offset. See the comments on the Transduction parameter below. The absolute armature offset may depend also on the actual excursion used in the measurement. Thus, it is recommended practice reporting the voice coil offset Xoffset together with the transduction parameter Tem and amplitude Xpeak. Example: Xoffset= 40 μm (@Xpeak= 200 μm) Diaphragm Coil Drive rod Magnet 1 Output Armature Air gap Pole Piece Magnet 2 Diaphragm Drive rod Offset Pole Piece Fig. 1: Schematic view of the armature offset. Application to end-of-line testing An armature offset generates 2nd-order harmonic and intermodulation distortion and should be close to zero. Thus, the armature shall be well centered in the magnetic field. A permissible range defined by minimal or maximal QC limits may be applied to KLIPPEL Analyzer System Page 3 of 7

K LIP PE L Balanced Armature Check (BAC) 3 Requirements S39 Transduction Parameter T em Xoffset to check for a PASS/FAIL decision. The absolute armature offset in [µm] is based on the impedance measurement and one absolute mechanical parameter. This parameter is needed to calibrate the mechanical system. This parameter is specific to the BA type under test. The transduction parameter Tem, which is similar to the Bl-factor of electrodynamic speakers, is used in the BAC module for this purpose. This parameter can be measured or simulated. If no Tem is specified, the offset is presented as a relative value in [%]. It is related to the peak displacement during the test. Importing Tem from LPM: Using the R&D module Linear Parameter Measurement LPM this parameter can be measured using a displacement laser sensor. For an accurate absolute armature offset the laser should access the excursion of the armature within the magnetic gap. In most cases this is not possible. It is common practice to use a certain point on the membrane, which is excited by a drive rod. This is not the offset of the armature inside the magnetic gap due to the leveler effect. If the mechanical details are known, the leveler effect can be compensated by a simple factor. Tem strongly depends on the position of the laser target point on the membrane even for very low frequencies. The Scanner module SCN (Klippel R&D System) can be used, to assess the vibration behavior at around the resonance frequency. 3 Requirements 3.1 Hardware Minimal Setup Device Under Test Production Analyzer FIREWIRE POWER USB DIGITAL I/0 AMP SPEAKER 1 SPEAKER2 OUT1 OUT2 MIC1 LINE1 LINE2 MIC2 PASS Frequence Response Polarity THD 2nd Harmonic 3rd Harmonic Impedance Re fs USB AMP Power Amplifier Input default routing alternative routing The figure above shows the minimal equipment required to run the BAC: KLIPPEL Production Analyzer Power amplifier and cables Or: KLIPPEL Analyzer 3 AS (incl Amplifier and Speaker Card) PC USB license dongle The BAC can be combined with traditional tests such as SPL, THD, Rub&Buzz, polarity KLIPPEL Analyzer System Page 4 of 7

Balanced Armature Check (BAC) 3 Requirements S39 Production Analyzer KLIPPEL Analyzer 3 Power Amplifier using optional equipment microphones, barcode reader, switches, assembly line control via digital I/O connector The Production Analyzer hardware provides current and voltage sensors for two speaker channels. This allows performing an alternative testing of drive units. While a first drive unit is measured on connector SPEAKER 1 a second drive unit will be connected to connector SPEAKER 2. To guarantee an optimal signal-to-noise ratio for balanced armature measurements, the standard current sensors may be non-ideal. The High Sensitivity version of the Production Analyzer is recommended. Please find more information in H4 Production Analyzer Hardware for detailed specification. In order to use the MSC with the KLIPPEL R&D System (from version 210), the KA3 hardware is required. The analyzer is also supported from QC Version 6. No external amplifier is required. The required minimal card configuration for use with external amplifier is: XLR Card Speaker Card In case no external amplifier is required, the following cards are required: Speaker Amplifier Card Please refer to the specifications of the KA3 and the extension cards for more information. Any standard audio amplifier meeting the power and bandwidth requirements of the tests may be used. A power amplifier may be omitted in case a KA3 equipped with an Amplifier Card is used and it fulfils the peak voltage and power requirements. Find more details in KLIPPEL_Amplifier_Requirements 3.2 Software QC Framework R&D Framework The BAC requires QC Standard software. BAC is installed with the QC software; no additional setup is required. A dedicated license is required to operate the module. From release version 210, the BAC may be operated within the KLIPPEL RnD software release. No additional setup, only an MSC license is required for operation. Note: KLIPPEL Analyzer 3 (KA3) hardware is required to operate the MSC in the RnD software framework. 3.3 Further Requirements Test Fixture Acoustical Environment The transducer may be measured in free air or with a closed port to achieve a better linear fitting due to the absence of acoustic resonances. There are no specific requirements, the BAC is very insensitive to ambient noise. KLIPPEL Analyzer System Page 5 of 7

Balanced Armature Check (BAC) 4 Limits S39 4 Limits 4.1 Transducer Parameter Symbol Min Typ. Max Unit Coil resistance 1 Re 0.1 20-250 Resonance frequency fs 15 6000 Hz Total loss factor Qts 0.3 6 Principle Balanced Armature transducer 1 Maximal resistance depends on the current sensor used in the Production Analyzer 4.2 Requirements for Power Amplifier Maximal input level 15 dbu Frequency response ref. 1 KHz @ 5Hz... 20 khz 1 db Input sensitivity at rated output power 0 (775) dbu (mv) 4.3 Input Parameters (Setup) Parameter Symbol Min Typ. Max Unit rms voltage Urms 0.1 4 200 V Driver Type Type small BA (fs>1khz) large BA (fs<1khz) general (advanced mode) Calibration of mechanical units 2 Calibration Relative (no import required) Tem(x=0) import Transduction coefficient (if Tem(x=0) import selected) Tem(x=0) 0.01 N/A Optional Input Parameters (if advanced mode selected) lowest frequency of multi-tone complex f start 2 2 20 Hz highest frequency of multi-tone complex f stop 375 12000 Hz Excitation Density (number of tones in multi-tone complex) Resolution 1 20 200 tones/ octave Duration of stimulus T 0.17 0.68 5.46 s Number of loops repeated the stimulus before measurement to get steady-state Pre-loop 0 0.5 20 KLIPPEL Analyzer System Page 6 of 7

Balanced Armature Check (BAC) 5 Measurement Results S39 5 Measurement Results Measured Quantity Symbol Unit QC limits applicable LARGE SIGNAL PARAMETERS (ABSOLUTE) 1 Armature offset Xoffset μm x RELATIVE LARGE SIGNAL PARAMETERS (RELATIVE) Relative armature offset Xoffset/max(Xpeak, Xbottom) % x PARAMETERS AT THE REST POSITION (X=0) Voice coil resistance Re Ohm x Resonance frequency fs Hz x Total loss factor Qts x Impedance curve Zel(f) Ohm x Inductance of the LR2 Model 3 Le mh x STATE INFORMATION Peak Current Ipeak A Peak Voltage upeak V Positive Peak Displacement 1 Xpeak μm Negative Peak Displacement 1 Xbottom μm Headroom Current Hi db Distortion Current Di db 1 Additional information about the mechanical system is required (import Tem at x=0) 2 Absolute identification of the mechanical parameters without laser sensor requires import of Tem(x=0) 3 The coil inductance is only approximated from the Wright model to deliver an easy interpretable parameter. Balanced Armature inductances cannot be described by the simple Le inductance model in general. 6 Patents Germany 102013012811 USA 14/499,379 China 2014103769646 Korea 1020140095591 Find explanations for symbols at: http://www.klippel.de/know-how/literature.html Last updated: July 09, 2018 KLIPPEL Analyzer System Page 7 of 7