Product information. Marine, Oil & Gas.

Similar documents
OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Kerman & Kavian Cable Industries ( KCI )

Copyright June Nexans

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Marine Cables General Catalogue

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

T E C H N I C A L D A T A for

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Armoured Power and Control Cables to BS7917

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Armoured Power and Control Cables Fire Resistant

Armoured Instrumentation Cables to BS6883

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

CIR (Crush & Impact Resistant) VFD Power Cable

Installation Recommendations

GEXOL WORLD CLASS OIL & GAS CABLES

DNVGL-CP-0400 Edition December 2015

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

MarineLine YOZp 0,6/1 kv

Armoured Power and Control Cables to BS6883

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Medium Voltage Power Cables

List Price w.e.f. 02nd January, 2018

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

Power Cables and their Application

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

Information technology. Generic cabling systems, General requirements

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Complete, innovative cables range for shipbuilding industry

15 years of experience

NETWORK CONNECTIVITY SYSTEMS

COPPER + LWL RAW CABLES

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

P Low Voltage Catalogue Cables Australia Powering your Project

FLEXIBLE MULTI CORE CABLES

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

Cables for data transmission in industrial automation

INTERNATIONAL STANDARD

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

CABLES AND WIRES

SUBMERSIBLE PUMP CABLES

SUPERIOR MARINE CABLE SOLUTIONS

INTERNATIONAL STANDARD

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Railway products. Edition 2014

FLAME RETARDANT INSTRUMENTATION CABLE. Application Standard

UNIRAIL D RS485 and BUS cables

Coaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

SHIPLINK TM to support your performance: cable solutions and services for safety and reliability

REPORT OF PERFORMANCE TIC

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

IEC Standard Caledonian Offshore & Marine Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

Notes 3 Explanatory Information 4-10

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

MULTIMEDIA CABLE H6091ZHB

CUSTOM DESIGN COAXIAL CABLES BY SICAB

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

ABOUT US ABOUT US 1 CRANE CABLES

The Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock

Instrumentation Cables

MULTIMEDIA & DATA TRANSMISSION

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

CAT 5e UTP Cable: NETSET BOX [305m], indoor

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

kv: medium voltage reeling cable with fibreoptics

The Quality Connection. ICON Product Guide

DLO Flexible Power Cable

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Selection table for flat & ribbon cables

Cables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables

BENDING RADIUS. DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance CORE IDENTIFICATION TECHNICAL INFORMATION 8/2010

Caledonian. VG Series. Caledonian Navy Cables.

Servo Cable Selection

SPEC 44. Wire and cable

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

H155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.

Detailed Specifications & Technical Data

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

Category 6 A F/FTP Euroclass C ca Cables

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

Instrumentation Cable PLTC/ITC and TC Types

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

Transcription:

Product information Marine, Oil & Gas www.drakamog.com

DRAKA Product information MOG 2010

Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded challenging marine and offshore demands for electrical and data solutions. As a leading provider of cabling solutions, we are backed by quality manufacturing and local inventory in every key marine and offshore market. By focusing on customer needs, Draka employees deliver trusted, timely and dependable service for ships, oil rigs, subsea and offshore wind farms. We take pleasure in presenting this catalog with our Shipboard cables. The ShipLine Plus range is our standard range suitable for all ships including dredging vessels, marine vessels and FPSO s. The cables have an innersheet and circular non-compacted s for increased flexibility and ease of installation. For applications in less harsh environment like yachts and cruise vessels, we have the ShipLine range. This range is lighter and more compact. In addition to these ranges we supply an extensive range of data cables, medium voltage cables, offshore cables and special cables. You will find members of the Draka team working all around the globe, with strong presence in your home market. They represent literally hundreds of years of experience with product development, quality management and on-time project delivery. This unique expertise and understanding of the market enables Draka to provide you with the services you need to meet your toughest marine and offshore challenge. Please visit www.drakamog.com to learn more about what Draka can do to help you and for more the most recent information about our products. Yours sincerely, Draka For use in emergency systems where Fire Resistant cables (IEC 60331) is needed, we have our ShipLine FR cables available from stock. ShipLine Plus halogen-free international standards circular s easy to install ShipLine halogen-free international standards light-weight cost-saving ShipLine Fire Resistant halogen-free international standards fire resistant DRAKA Product information MOG 2010 3

Sheath colours Power Instrument/signal Fire resistant black grey green Core identification 1 core black 2 cores blue brown 3 cores brown black grey 4 cores blue - brown black grey 5 cores blue - brown black grey black 6 cores and above white with black numbers Earth core yellow/ green (optional) Standards applied IEC 60092-3 IEC 60092-350 IEC 60092-351 IEC 60092-353 IEC 60092-359 IEC 60092-375 IEC 60092-376 IEC 60331 IEC 60332-1 IEC 60332-3A IEC 60754-1,2 IEC 61034-1,2 Electrical installations in ships Construction, testing and installation Low voltage shipboard power cables Insulating materials for shipboard power cables Single and multicore cables with extruded solid insulation for rated voltages 0.6/ 1 kv Sheating materials for shipboard power and telecommunication cables Shipboard telecommunication cables and radio frequency cables General instrumentation, control and communication cables Shipboard multicore cables for control circuits Tests for electric cables under fire conditions Circuit integrity Tests on electric cables under fire conditions Single vertical insulated wire or cable Tests on electric cables under fire conditions Vertical flame spread of vertically mounted bunched wires and cables, category A Tests on gases evolved during combustion of materials from cables Determination of the amount of halogen acid gas Determination of degree of acidity by measuring Ph and conductivity Measurement of smoke density of cables burning under defined conditions Test apparatus, test procedures and requirements Approvals American Bureau of Shipping Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Certification by other classification bureaus at request. 4 DRAKA Product information MOG 2010

Index ShipLine Plus Page TFXI 0.6/1 kv (HUSK) Power cable, unarmoured 6 TIOI 0.6/1 kv (HUSO) Power cable, armoured 8 TIOI (c) 250 V (HUCOM) Instrumentation cable, screened 11 ShipLine TI 0.6/1 kv Power cable, unarmoured 12 TXOI 0.6/1 kv Power cable, armoured 14 TXOI 250 V Instrumentation cable, screened 16 ShipLine Fire Resistant BI FR 0.6/1 kv Power cable, Fire Resistant, unarmoured 17 BXOI FR 0.6/1 kv Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables Overview Data, FR, Video/Audio, CATV 20 Electrical characteristics of cables 21 Also available on request Offshore cables RFOU (NEK606) LV, MV, instrumentation (Mud resistant) BFOU (NEK606) LV, MV, instrumentation (Fire/Mud resistant) RFCU (UKOOA) LV, MV, instrumentation (Mud resistant) BFCU (UKOOA) LV, MV, instrumentation (Fire/Mud resistant) Type P (IEEE45) LV, MV, instrumentation (Mud resistant) HXXM (IEEE45/IEC) LV, MV, instrumentation (Fire resistant) Special cables Flexible EMC Dredging cable 0,6/1 kv and 1,8/3,6 kv NEK606 HCF 1100C NEK606 Artic Grade (Cold bend/cold impact) TFOI 6/10 kv (also other Voltage rates on request) Down hole Pump cable VFD cables Hulto EMC ShipLine Plus Fire Resistant BFXI 0.6/1 kv (HUSK FR) Power cable, Fire Resistant, not braided BIOI 0.6/1 kv (HUSO FR) Power cable, Fire Resistant, braided BIOI 250 V (HUCOM FR) Instrumentation cable, Fire resistant, braided For more information about these cables please visit www.drakamog.com DRAKA Product information MOG 2010 5

ShipLine Plus TFXI 0.6/1 kv (HUSK) Halogen free shipboard and offshore cable Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Design stadard: IEC 60092-353 Max. temp.: 90 C * Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green: Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey > 4 cores + earth Yellow/green - White with black numbers * Temporary overload permissible up to 130 C Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Bedding F Halogen free material Armour/screen X No armouring Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and crosssection (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) 128624 1x10 3.9 5.3 7.3 125 88 1.83 2.33 - - 128625 1x16 5.0 6.4 8.4 185 119 1.15 1.47 - - 128626 1x25 6.3 8.1 10.3 290 158 0.727 0.927 - - 128627 1x35 7.5 9.3 11.5 375 197 0.524 0.669 - - 128628 1x50 8.7 10.7 13.1 500 239 0.387 0.494 - - 128629 1x70 10.5 12.7 15.3 705 307 0.268 0.343 - - 128630 1x95 12.4 14.6 17.2 950 374 0.193 0.248 - - 128631 1x120 14.0 16.4 19.2 1210 435 0.153 0.198 - - 128634 1x150 15.5 18.3 21.3 1490 502 0.124 0.161 - - 128632 1x185 17.4 20.6 23.6 1850 575 0.0991 0.130 - - 128633 1x240 19.9 23.3 26.5 2405 679 0.0754 0.101 - - 125130 2x1.5 1.6 3.0 8.6 110 23 12.1 15.4 0.33 59 125131 2x2.5 2.0 3.5 9.6 150 31 7.41 9.45 0.31 66 125132 2x4 2.5 4.0 10.7 195 43 4.61 5.88 0.29 73 125134 2x6 3.1 4.5 12.0 260 55 3.08 3.93 0.28 79 125144 2x10 3.9 5.4 13.7 375 75 1.83 2.33 0.26 86 125119 2x16 5.0 6.4 16.0 545 100 1.15 1.47 0.25 93 126442 3G1.5 1.6 3.0 9.2 130 23 12.1 15.4 0.33 59 126444 3G2.5 2.0 3.5 10.2 175 31 7.41 9.45 0.31 66 125104 3x1.5 1.6 3.0 9.2 130 20 12.1 15.4 0.33 118 125015 3x2.5 2.0 3.5 10.2 175 28 7.41 9.45 0.31 132 125105 3x4 2.5 4.0 11.3 235 37 4.61 5.88 0.29 146 working capacitance (nf/km) 3 6 DRAKA Product information MOG 2010

ShipLine Plus TFXI 0.6/1 kv (HUSK) Halogen free shipboard and offshore cable product number no. of cores and crosssection (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) 125106 3x6 3.1 4.5 12.7 315 47 3.08 3.93 0.28 158 125107 3x10 3.9 5.4 14.7 470 65 1.83 2.33 0.26 172 125109 3x16 5.0 6.4 17.0 680 87 1.15 1.47 0.25 186 125088 3x25 6.3 8.1 21.1 1060 110 0.727 0.927 0.25 199 125110 3x35 7.5 9.4 23.9 1390 137 0.524 0.669 0.24 208 125089 3x50 8.7 10.8 28.3 1925 167 0.387 0.494 0.24 218 124994 3x70 10.5 12.8 33.1 2710 214 0.268 0.343 0.23 228 125090 3x95 12.4 14.7 37.8 3670 259 0.193 0.248 0.22 237 125112 3x120 14.0 16.5 42.0 4600 301 0.153 0.198 0.22 244 125111 3x150 15.5 18.4 46.3 5625 347 0.124 0.161 0.22 250 126443 4G1.5 1.6 3.0 10.0 155 20 12.1 15.4 0.35 135 126445 4G2.5 2.0 3.5 11.1 205 28 7.41 9.45 0.33 150 126446 4G6 3.1 4.5 13.9 385 47 3.08 3.93 0.30 176 125135 4x1.5 1.6 3.0 10.0 155 20 12.1 15.4 0.35 135 125140 4x2.5 2.0 3.5 11.1 205 28 7.41 9.45 0.33 150 125141 4x4 2.5 4.0 12.6 290 37 4.61 5.88 0.31 164 125143 4x6 3.1 4.5 13.9 385 47 3.08 3.93 0.30 176 125145 4x10 3.9 5.4 16.1 580 65 1.83 2.33 0.29 192 125146 4x16 5.0 6.4 18.9 860 87 1.15 1.47 0.28 206 127385 5G1.5 1.6 3.0 10.9 185 20 12.1 15.4-140 127386 5G2.5 2.0 3.5 12.3 250 28 7.41 9.45-155 125441 5x1.5 1.6 3.0 10.9 185 20 12.1 15.4-140 125440 5x2.5 2.0 3.5 12.3 250 28 7.41 9.45-155 128639 6x1.5 1.6 3.0 11.4 175 15 12.1 15.4-155 128640 7x1.5 1.6 3.0 11.5 185 14 12.1 15.4-155 128647 8G1.5 1.6 3.0 12.7 220 14 12.1 15.4-155 128641 8x1.5 1.6 3.0 12.7 220 13 12.1 15.4-155 128642 10x1.5 1.6 3.0 14.6 265 12 12.1 15.4-155 128643 12x1.5 1.6 3.0 15.3 315 11 12.1 15.4-155 128644 16x1.5 1.6 3.0 17.0 400 10 12.1 15.4-155 128645 19x1.5 1.6 3.0 18.1 470 9 12.1 15.4-155 128646 24x1.5 1.6 3.0 21.3 620 8 12.1 15.4-155 working capacitance (nf/km) 3 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. 1 G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 21. 3 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. DRAKA Product information MOG 2010 7

ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Design standard: IEC 60092-353 Max. temp.: 90 C * Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey * Temporary overload permissible up to 130 C Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1 Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 3 125043 1x10 2.5 3.9 5.4 10.0 210 88 1.83 2.33 - - 125044 1x16 2.5 5.0 6.4 11.0 280 119 1.15 1.47 - - 125047 1x25 4 6.3 8.1 13.1 410 158 0.727 0.927 - - 125048 1x35 6 7.5 9.4 14.8 545 197 0.524 0.669 - - 125050 1x50 6 8.7 10.8 16.4 690 239 0.387 0.494 - - 125058 1x70 6 10.5 12.8 18.8 935 307 0.268 0.343 - - 125059 1x95 10 12.4 14.7 20.7 1205 374 0.193 0.248 - - 125051 1x120 10 14.0 16.5 22.9 1500 435 0.153 0.198 - - 125053 1x150 16 15.5 18.4 25.0 1810 502 0.124 0.162 - - 125055 1x185 16 17.4 20.7 27.6 2225 575 0.0991 0.131 - - 125056 1x240 16 19.9 23.4 30.5 2825 679 0.0754 0.102 - - 127296 1x300 25 22.3 26.0 34.0 3540 785 0.0601 0.0831 - - 125061 2x1.5 4 1.6 3.0 11.3 205 23 12.1 15.4 0.36 99 125078 2x2.5 4 2.0 3.5 12.4 255 31 7.41 9.45 0.34 118 125080 2x4 6 2.5 4.0 13.9 345 43 4.61 5.88 0.32 135 127302 2x6 6 3.1 4.5 15.2 430 55 3.08 3.93 0.30 150 125034 2x10 10 3.9 5.4 17.0 570 75 1.83 2.33 0.29 169 125035 2x16 16 5.0 6.4 19.8 815 100 1.15 1.47 0.27 186 127321 2x25 16 6.3 8.1 23.2 1135 130 0.727 0.927 0.27 203 127328 2x35 16 7.5 9.4 26.0 1415 161 0.524 0.669 0.25 215 127379 3G1.5 4 1.6 3.0 12.0 235 23 12.1 15.4 0.36 60 8 DRAKA Product information MOG 2010

ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self induc tance (mh/km) working capacitance (nf/km) 3 127380 3G2.5 4 2.0 3.5 13.0 290 31 7.4 19.45 0.34 70 125020 3x1.5 4 1.6 3.0 12.0 235 20 2.1 15.4 0.36 121 125016 3x2.5 4 2.0 3.5 13.0 290 28 7.41 9.45 0.34 140 125021 3x4 4 2.5 4.0 14.5 400 37 4.61 5.88 0.32 157 125022 3x6 6 3.1 4.5 15.9 485 47 3.08 3.93 0.30 172 125019 3x10 10 3.9 5.4 18.0 685 65 1.83 2.33 0.29 191 125024 3x16 16 5.0 6.4 20.8 960 87 1.15 1.47 0.27 209 125023 3x25 16 6.3 8.1 24.6 1365 110 0.727 0.927 0.27 225 125069 3x35 16 7.5 9.4 27.7 1755 137 0.524 0.669 0.25 238 125067 3x50 25 8.7 10.8 32.7 2440 167 0.387 0.494 0.25 251 124995 3x70 35 10.5 12.8 37.7 3370 214 0.268 0.343 0.24 264 125032 3x95 50 12.4 14.7 43.3 4585 259 0.193 0.248 0.23 275 125026 3x120 60 14.0 16.5 47.7 5705 301 0.153 0.198 0.23 284 125030 3x150 70 15.5 18.4 52.2 6805 347 0.124 0.162 0.23 292 127381 4G1.5 4 1.6 3.0 12.8 265 20 12.1 15.4 0.39 129 127382 4G2.5 6 2.0 3.5 14.3 360 28 7.41 9.45 0.36 149 125082 4x1.5 4 1.6 3.0 12.8 265 20 12.1 15.4 0.39 129 125092 4x2.5 6 2.0 3.5 14.3 360 28 7.41 9.45 0.36 149 125094 4x4 6 2.5 4.0 15.8 465 37 4.61 5.88 0.34 166 125095 4x6 6 3.1 4.5 17.2 585 47 3.08 3.93 0.33 181 125036 4x10 10 3.9 5.4 19.4 805 65 1.83 2.33 0.31 200 125040 4x16 16 5.0 6.4 22.9 1165 87 1.15 1.47 0.30 218 125041 4x25 16 6.3 8.1 26.9 1680 110 0.727 0.927 0.30 235 128022 4x35 16 7.5 9.3 29.7 2090 137 0.524 0.669 0.28 247 128024 4x50 25 8.7 10.7 35.5 2975 167 0.387 0.494 0.27 261 128023 4x70 35 10.5 12.7 40.8 4050 214 0.268 0.343 0.26 273 128025 4x95 50 12.4 14.6 47.0 5540 259 0.193 0.248 0.25 285 127383 5G1.5 4 1.6 3.0 13.8 305 20 12.1 15.4-134 127384 5G2.5 2.5 2.0 3.5 15.5 420 28 7.41 9.45-154 125407 5x1.5 4 1.6 3.0 13.8 305 20 12.1 15.4-134 125408 5x2.5 2.5 2.0 3.5 15.5 420 28 7.41 9.45-154 125096 6x1.5 6 1.6 3.0 14.6 340 15 12.1 15.4-145 125100 6x2.5 6 2.0 3.5 16.1 425 20 7.41 9.45-165 125099 7x1.5 6 1.6 3.0 14.7 355 14 12.1 15.4-145 125117 7x2.5 6 2.0 3.5 16.1 445 19 7.41 9.45-165 125118 8x1.5 6 1.6 3.0 15.9 400 13 12.1 15.4-145 125122 10x1.5 10 1.6 3.0 17.9 470 12 12.1 15.4-145 125123 12x1.5 10 1.6 3.0 18.6 525 11 12.1 15.4-145 125126 16x1.5 10 1.6 3.0 20.3 645 10 12.1 15.4-145 125127 19x1.5 10 1.6 3.0 21.6 730 9 12.1 15.4-145 125128 24x1.5 16 1.6 3.0 24.8 925 8 12.1 15.4-145 DRAKA Product information MOG 2010 9

ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. 1 G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 21. 3 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. 10 DRAKA Product information MOG 2010

ShipLine Plus TIOI (c) 250 V (HUCOM) Armoured halogen free shipboard and offshore cable Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22(cat.A) Design standard: IEC 60092-376 Core identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc. 1x3 cores (triple) is identified with no. 1, 2 and 3 1x4 cores (quad): Pair no.1 core no. 1 and 2 Pair no.2 core no. 3 and 4 Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Lay up Numbered cores twisted to pair/triple/quad and wrapped with polyester tape. Pairs/triple/quad are laid up and collectively screened by aluminium polyester tape with tinned copper drain wire 0,5 mm 2. Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1 Armour/screen O Tinned copper wire braid. PETP-tape. Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Grey product number no. of cores and cross-section (n x mm 2 ) core outer 125154 1x2x0.75 1.10 2.1 8.5 120 125156 1x4x0.75 1.10 2.1 9.5 155 125157 4x2x0.75 1.10 2.1 14.5 300 125159 7x2x0.75 1.10 2.1 17 405 125160 10x2x0.75 1.10 2.1 20.5 560 125161 14x2x0.75 1.10 2.1 22.5 700 125162 19x2x0.75 1.10 2.1 24.5 835 125163 24x2x0.75 1.10 2.1 28 1030 approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single pair/triple 0.75 70 0.8 26.0 Single quad 0.75 60 0.8 26.0 Multi pair 0.75 60 0.8 26.0 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature DRAKA Product information MOG 2010 11

ShipLine TI 0.6/1 kv Halogen free shipboard and offshore cable Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22(cat.A) Design standard: IEC 60092-353 Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded copper, 3-core cables 50 mm 2 sector shaped, other types circular Insulation T Crosslinked polyethylene, XLPE Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 3 124841 2x1.5 1.6 3.0 8.4 80 23 12.1 15.4 0.33 52 124842 2x2.5 2.0 3.5 9.2 100 31 7.41 9.45 0.31 59 124843 2x4 2.5 4.0 10.3 135 43 4.61 5.88 0.29 65 124844 2x6 3.1 4.5 11.6 185 55 3.08 3.93 0.28 70 124845 2x10 3.9 5.4 13.3 275 75 1.83 2.33 0.26 76 124846 2x16 5.0 6.4 15.6 400 100 1.15 1.47 0.25 82 124850 3G1.5 1.6 3.0 8.8 100 23 12.1 15.4 0.33 51 125526 3G2.5 2.0 3.5 9.8 130 31 7.41 9.45 0.31 58 127213 3G4 2.5 4.0 11.1 190 43 4.61 5.88 0.29 64 127215 3G6 3.1 4.5 12.3 250 55 3.08 3.93 0.28 70 124849 3x1.5 1.6 3.0 8.8 100 20 12.1 15.4 0.33 101 124851 3x2.5 2.0 3.5 9.8 130 28 7.41 9.45 0.31 115 124852 3x4 2.5 4.0 11.1 190 37 4.61 5.88 0.29 128 124853 3x6 3.1 4.5 12.3 250 47 3.08 3.93 0.28 139 124854 3x10 3.9 5.4 14.3 385 65 1.83 2.33 0.26 154 124855 3x16 5.0 6.4 16.6 560 87 1.15 1.47 0.25 167 124856 3x25 6.3 8.1 20.7 880 110 0.727 0.927 0.25 179 124857 3x35 7.5 9.4 23.5 1220 137 0.524 0.669 0.24 188 124858 3x50 SS 6.8/12.2 8.9/14.3 22.8 1530 167 0.387 0.494 0.18 203 124859 3x70 SS 8.2/14.6 10.5/16.9 26.7 2155 214 0.268 0.343 0.18 211 124860 3x95 SS 10.9/17.3 13.5/21.9 30.2 2900 259 0.193 0.248 0.17 219 124861 3x120 SS 12.2/21.7 15.2/24.7 34 3680 301 0.153 0.198 0.17 224 124864 4G1.5 1.6 3.0 9.6 120 20 12.1 15.4 0.35 116 127212 4G2.5 2.0 3.5 10.7 165 28 7.41 9.45 0.33 131 127214 4G4 2.5 4.0 12.2 240 37 4.61 5.88 0.31 144 12 DRAKA Product information MOG 2010

ShipLine TI 0.6/1 kv Halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 3 127216 4G6 3.1 4.5 13.5 320 47 3.08 3.93 0.30 156 127345 4G10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 171 127416 4G16 5.0 6.4 18.5 740 87 1.15 1.47 0.28 184 127343 4G25 6.3 8.1 22.8 1145 110 0.727 0.927 0.28 197 124863 4x1.5 1.6 3.0 9.6 120 20 12.1 15.4 0.35 116 124865 4x2.5 2.0 3.5 10.7 165 28 7.41 9.45 0.33 131 124866 4x4 2.5 4.0 12.2 240 37 4.61 5.88 0.31 144 124867 4x6 3.1 4.5 13.5 320 47 3.08 3.93 0.30 156 124868 4x10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 171 124869 4x16 5.0 6.4 18.5 740 87 1.15 1.47 0.28 184 127200 4x25 6.3 8.1 22.8 1145 110 0.727 0.927 0.28 197 124871 5G1.5 1.6 3.0 10.5 145 20 12.1 15.4-124 124873 5G2.5 2.0 3.5 11.9 205 28 7.41 9.45-137 124870 5x1.5 1.6 3.0 10.5 145 20 12.1 15.4-124 124872 5x2.5 2.0 3.5 11.9 205 28 7.41 9.45-137 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. For single core and multi core (>5 cores) versions of TI-types, please refer to our TFXI-range (page 6). 1 SS = sector-shaped G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 21. 3 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. DRAKA Product information MOG 2010 13

ShipLine TXOI 0.6/1 kv Armoured halogen free shipboard and offshore cable Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Design standard: IEC 60092-353 Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded copper, 3-core cables 50 mm 2 sector shaped, other types circular Insulation T Crosslinked polyethylene, XLPE Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 3 124884 1x16 2.5 5.0 6.4 9.8 245 119 1.15 1.47 - - 124885 1x25 4 6.3 8.1 11.7 360 158 0.727 0.927 - - 124886 1x35 4 7.5 9.4 13.0 455 197 0.524 0.669 - - 124887 1x50 6 8.7 10.8 15.0 620 239 0.387 0.494 - - 124888 1x70 6 10.5 12.8 17.2 850 307 0.268 0.343 - - 124889 1x95 10 12.4 14.7 19.1 1115 374 0.193 0.248 - - 124890 1x120 10 14.0 16.5 21.1 1385 435 0.153 0.198 - - 124894 2x1.5 2.5 1.6 3.0 9.4 125 23 12.1 15.4 0.36 111 124895 2x2.5 2.5 2.0 3.5 10.2 155 31 7.41 9.45 0.34 133 124896 2x4 4 2.5 4.0 11.5 200 43 4.61 5.88 0.32 154 124897 2x6 6 3.1 4.5 13.0 280 55 3.08 3.93 0.30 172 124898 2x10 10 3.9 5.4 14.9 390 75 1.83 2.33 0.29 194 124899 2x16 16 5.0 6.4 17.6 600 100 1.15 1.47 0.27 214 127202 3G1.5 2.5 1.6 3.0 9.9 150 23 12.1 15.4 0.36 66 127198 3G2.5 2.5 2.0 3.5 10.8 185 31 7.41 9.45 0.34 78 124900 3x1.5 2.5 1.6 3.0 9.9 150 20 12.1 15.4 0.36 132 124901 3x2.5 2.5 2.0 3.5 10.8 185 28 7.41 9.45 0.34 156 124902 3x4 4 2.5 4.0 12.1 250 37 4.61 5.88 0.32 178 124903 3x6 6 3.1 4.5 13.9 355 47 3.08 3.93 0.30 197 124904 3x10 10 3.9 5.4 15.7 495 65 1.83 2.33 0.29 221 124905 3x16 16 5.0 6.4 18.6 760 87 1.15 1.47 0.27 243 124906 3x25 16 6.3 8.1 22.7 1095 110 0.727 0.927 0.27 264 14 DRAKA Product information MOG 2010

ShipLine TXOI 0.6/1 kv Armoured halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 3 124907 3x35 16 7.5 9.4 24.9 1340 137 0.524 0.669 0.25 279 124908 3x50 SS 25 6.8/12.2 8.9/14.3 24.8 1820 167 0.387 0.494 0.19 317 124909 3x70 SS 35 8.2/14.6 10.5/16.9 29.7 2580 214 0.268 0.343 0.19 336 124910 3x95 SS 50 9.7/17.3 12.1/19.7 33.1 3435 259 0.193 0.248 0.18 353 127205 3x120 SS 25 10.9/19.3 13.5/21.9 36.0 4075 301 0.153 0.198 0.18 366 127347 3x150 SS 25 12.2/21.7 15.2/24.7 39.1 4950 347 0.124 0.161 0.18 379 127203 4G1.5 2.5 1.6 3.0 10.6 175 20 12.1 15.4 0.39 135 127199 4G2.5 2.5 2.0 3.5 11.9 230 28 7.41 9.45 0.36 159 124913 4x1.5 2.5 1.6 3.0 10.6 175 20 12.1 15.4 0.39 135 124914 4x2.5 2.5 2.0 3.5 11.9 230 28 7.41 9.45 0.36 159 124915 4x4 6 2.5 4.0 13.8 340 37 4.61 5.88 0.34 181 124916 4x6 6 3.1 4.5 15.1 435 47 3.08 3.93 0.33 200 124917 4x10 10 3.9 5.4 17.3 630 65 1.83 2.33 0.31 224 124918 4x16 16 5.0 6.4 20.5 940 87 1.15 1.47 0.30 246 124919 4x25 16 6.3 8.1 24.4 1345 110 0.727 0.927 0.30 267 124920 5x1.5 2.5 1.6 3.0 11.8 210 16 12.1 15.4-136 124921 5x2.5 2.5 2.0 3.5 12.9 270 22 7.41 9.45-161 126759 6x1.5 4 1.6 3.0 12.7 240 15 12.1 15.4-145 124924 7x1.5 4 1.6 3.0 12.7 260 14 12.1 15.4-145 126760 8x1.5 6 1.6 3.0 15.5 340 13 12.1 15.4-145 124926 10x1.5 6 1.6 3.0 16.2 390 12 12.1 15.4-145 124927 12x1.5 6 1.6 3.0 16.9 440 11 12.1 15.4-145 124928 16x1.5 6 1.6 3.0 18.6 550 10 12.1 15.4-145 124929 19x1.5 6 1.6 3.0 19.7 620 9 12.1 15.4-145 124930 24x1.5 10 1.6 3.0 22.9 800 8 12.1 15.4-145 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 SS = sector-shaped G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 2 3 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. DRAKA Product information MOG 2010 15

ShipLine TXOI (c) 250 V Armoured halogen free shipboard and offshore cable Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22(cat.A) Design standard: IEC 60092-376 Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Pair identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc. 1x3 cores (triple) is identified with no. 1, 2 and 3 1x4 cores (quad): Pair no.1 core no. 1 and 2 Pair no.2 core no. 3 and 4 Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Lay up Numbered white cores twisted in pairs. (Two pair version stranded into a star quad). The pairs are twisted with different lay lengths to reduce mutual interference. Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Grey product number no. of cores and cross-section (n x mm 2 ) core outer 127257 1x2x0.5 0.93 1.75 6.6 65 127258 1x4x0.5 0.93 1.75 7.3 85 124931 1x2x0.75 1.10 2.1 7.3 80 124933 1x4x0.75 1.10 2.1 8.2 105 124934 4x2x0.75 1.10 2.1 12.2 195 124936 7x2x0.75 1.10 2.1 14.4 270 124937 10x2x0.75 1.10 2.1 17.8 410 124938 14x2x0.75 1.10 2.1 19.3 500 124939 19x2x0.75 1.10 2.1 21.5 630 124940 24x2x0.75 1.10 2.1 25.2 805 approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single-pair 0.5 75 0.8 40.4 Multi-pair 0.5 75 0.8 40.4 Single-pair 0.75 70 0.8 26.0 Multi-pair 0.75 60 0.8 26.0 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature 16 DRAKA Product information MOG 2010

ShipLine Fire Resistant BI FR 0.6/1 kv Halogen free shipboard and offshore cable, fire resistant Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. For instrumentation, communication, control, alarm, emergency and critical systems. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Fire resistant - According to IEC 60331 Design standard: IEC 60092-353 Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 1 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 2 126458 2x1.5 1.6 3.3 8.5 85 23 12.1 15.4 0.36 54 126461 2x2.5 2.0 3.8 9.5 110 31 7.41 9.45 0.34 59 126459 3x1.5 1.6 3.3 9.5 110 20 12.1 15.4 0.36 108 126462 3x2.5 2.0 3.8 10.0 145 28 7.41 9.45 0.34 118 126463 3x4 2.5 4.3 11.5 205 37 4.61 5.88 0.32 130 126460 4x1.5 1.6 3.3 10.0 135 20 12.1 15.4 0.39 128 127061 4x6 3.1 4.8 14.5 340 47 3.08 3.93 0.32 161 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: Method E: Multi-core cables in free air - For 4 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures and cables laid in bundles are given on page 21. 2 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. DRAKA Product information MOG 2010 17

ShipLine Fire Resistant BXOI FR 0.6/1 kv Armoured halogen free shipboard and offshore cable, fire resistant Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. For instrumentation, communication, control, alarm, emergency and critical systems in both EX- and safe areas. Suitable for both indoor and outdoor installations. Design standard: IEC 60092-353 Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Fire resistant - According to IEC 60331 Pair identification Two cores Blue - Brown Three cores Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Inner sheath X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 1 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) 2 125758 2x1.5 2.5 1.6 3.3 10.0 135 23 12.1 15.4 0.39 130 125764 2x2.5 2.5 2.0 3.8 10.5 160 31 7.41 9.45 0.36 144 125760 3x1.5 2.5 1.6 3.3 10.5 160 20 12.1 15.4 0.39 145 125763 3x2.5 2.5 2.0 3.8 11.0 205 28 7.41 9.45 0.36 162 126457 3x4 4 2.5 4.3 12.5 275 37 4.61 5.88 0.34 185 126986 3x6 6 3.1 4.8 14.5 380 47 3.08 3.93 0.32 208 125765 3x10 10 4.4 5.8 16.8 535 65 1.83 2.33 0.30 219 126456 5x1.5 4 1.6 3.3 12.5 230 16 12.1 15.4-161 125761 7x1.5 6 1.6 3.3 13.5 290 14 12.1 15.4 - > 165 125762 12x1.5 6 1.6 3.3 18.0 480 11 12.1 15.4 - >165 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC 60092-352 Table A.4: Method E: Multi-core cables in free air - For 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 21. 2 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected 18 DRAKA Product information MOG 2010

ShipLine Fire Resistant BXOI FR 250 V Armoured halogen free shipboard and offshore cable, fire resistant Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. For instrumentation, communication, control, alarm, emergency and critical systems in both EX- and safe areas. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC 60754-1,2 Low smoke - According to IEC 61034-1,2 Flame retardant - According to IEC 60332-3-22 (cat.a) Fire resistant - According to IEC 60331 Design standard: IEC 60092-353 Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Core identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Lay up Colour coded cores twisted together and wrapped with polyester tape. The pairs are twisted with different lay length to reduce mutual interference. Pairs are identified by numbered tape. Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) core outer 125560 1x2x0.75 1.10 2.5 8.5 95 125766 2x2x0.75 1.10 2.5 13.0 170 127139 4x2x0.75 1.10 2.5 15.5 240 125767 7x2x0.75 1.10 2.5 18.5 390 130049 19x2x0.75 1.10 2.5 23.5 1040 127041 1x2x1.5 1.60 3.0 9.5 115 approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single/multi-pair 0.75 80 0.8 26.0 Single-pair 1.5 90 0.8 12.8 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature DRAKA Product information MOG 2010 19

Data cables Overview Data cables RF cables Data cables of the Universal Cable series UC are always in use wherever it is a question of high-speed data transmission in local networks (LAN). Whether Cat5e (Class D), Cat6 (Class E), Cat6a (Class Ea), Cat7 (Class Fa), Class7+ or multimedia - all data cables are in accordance with ISO/IEC 11801, EN 50173 and EIA/TIA 568A. On ships, data cables of the UC series are used for standarized and manufacturer-independent networks - Token Ring, Ethernet, ISDN, TPDDI, Fast-Ethernet 100BaseTX, ATM, Gigabit-Ethernet 1000Base T or 10 GbE. The radio-frequency cables are used in transmitter and receiver installations in radio communication as well as in the entire field of commercial radio-frequency technology and electronics. RG cables of the American standard according to MIL-C-17G have become the global standard. They are always applied where high quality is required. On ships, they serve as cables for transmitters and receivers in the radio technology and as connection cables in the navigation technology. Video and Audio cables CATV cables Audio cables are a perfect basis for digital and analogue transmission of audio signals. The digital audio cables are in accordance with the AES/EBU standard. Video cables are used as coaxial cables with a charcteristic impendence of 75Ω for the connection of recording and intermediate amplifiers as well as monitors and cameras. The specified frequency range up to 5000 MHz permits the application of the video cables for serial digital transmission, HDTV and future transmission technology. CATV cables are used in private and commercial trunk lines and TV signal distribution networks. They can be applied from the headend. Drop cables are used in private and commercial TV signal distribution networks and as antenna cables for terrestric and satellite broadcast systems. On ships, CATV cables are applied for example for the transmission of TV channels which are received via satellite TV or terrestric antennas and transmitted to the cabins. In the ship s own television studio for example, audio and video cables are applied in order to enable the transmission from the studio to the cabin. 20 DRAKA Product information MOG 2010

Data cables Electrical characteristics of cables Conductor resistance Maximum resistance of copper s according to IEC 60228 Class 2 mm 2 Minimum number of strands Circular Conductor Sector-shaped Conductor Ω/km 1.5 7-12.1 2.5 7-7.41 4 7-4.61 6 7-3.08 10 7-1.83 16 7-1.15 25 7-0.727 35 19 (7) - 0.524 50 19 (19) 19 (6) 0.387 70 37 (19) 37 (12) 0.268 95 37(19) 37 (15) 0.193 120 61 (37) 37 (18) 0.153 150 61 (37) 37 (18) 0.124 Influence of temperature on the Table 1 resistance Table 2 Temp. C Correction factor 20 1.000 25 1.020 30 1.039 35 1.059 40 1.079 45 1.098 50 1.118 55 1.138 60 1.157 65 1.177 70 1.196 75 1.216 80 1.236 85 1.255 90 1.275 Current ratings for continuous load Correction factors for ambient temperatures other than 45 C, according to IEC 60092 Table 3 Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75 Rating factor 1.2 1.15 1.11 1.05 1 0.94 0.88 0.82 0.74 0.67 0.58 Short circuit current The maximum permissible short circuit current for different cables is given in the figure aside. This figure is based on the formula: lk = 143 S/ t 100,0 Permissible short circuit current lk = the maximum permissible short circuit current S = the cross-section of the in mm 2 t = the duration of the short circuit in seconds Tk start = 90 C Tk end = 250 C The formula is applicable for an increase in temperature from 90 C at the start to 250 C at the end of the short circuit, when the duration of the short circuit is less than 5 seconds. Short circuit current in ka 10,0 1,0 150 120 95 70 50 35 25 16 10 6 Cross-section of the in mm 2 4 0,1 2,5 1,5 0,0 0,1 1,0 10,0 Duration of the short circuit in seconds DRAKA Product information MOG 2010 21

Data cables Electrical characteristics of cables Capacitance of Draka marine cables Working capacitance The actual value of the working capacitance of cables depends on the cable type, the electrical circuit in which the cable functions and, for unscreened and unarmoured cables, the method of installation. The working capacitance of a cable can be calculated by substitution of the partial capacitances in the formulas of table 4 by the value of table 5 and 6. As the theoretical calculation of the working capacitance of multicore cables, 1.5 or 2.5 mm 2, is very complex, no partial capacitances have been indicated. Generally, the value of the working capacitance will, in the case, be less than 100 nf/km. The calculation of the working capacitance Number of cores Cable type Voltage type Working capacitance Table 4 2 unscreened AC C12 screened AC symmetrical AC asymmetrical, screen grounded C12 + ½.C11 C12 + C11 3 unscreened 3 phase AC symmetrical 2 phase AC symmetrical, one core grounded 3.C12 1½.C12 screened 3 phase AC symmetrical 2 phase AC symmetrical, one core grounded 3.C12 + C11 1½.C12 + ½.C11 4 unscreened 3 phase AC, one core grounded CS = 3.C12 + C13 CR,T = 2½.C12 + 3.C13 screened 3 phase AC, one core and screen grounded CS = C11 + 3.C12 + C13 CR,T = C11 + 2½.C12 + 3.C13 CS = working capacitance of phase S CR,T = working capacitance of phases R and T The partial capacitance are defined as follows: C 12 1 2 2 C 12 C 23 1 4 C 13 2 3 C 23 C 12 C 34 C 13 C 14 C 24 1 4 C 11 C 12 C 22 1 2 C 22 2 C 12 C 23 1 4 C 13 C 11 C 33 C 22 C 33 2 3 C 23 C 12 C 34 C 13 C 24 1 4 C 14 C 11 C 44 screen screen screen 22 DRAKA Product information MOG 2010

Data cables Electrical characteristics of cables Partial capacitances in nf/km TI and TXOI TI in nf/km C12 C13 Number of cores mm 2 2 3 4 4 1.5 51 34 36 8 2.5 57 38 40 8 4 63 42 45 8 6 69 46 49 8 10 78 52 55 7 16 87 58 62 7 25-57 61 7 35-63 - - 50-64 - - 70-67 - - 95-72 - - 120-74 - - 150 - - - - Table 5 TXOI in nf/km C11 C12 C13 Number of cores mm 2 2 3 4 2 3 4 4 1.5 97 80 71 21 18 19 7 2.5 108 88 77 27 22 23 7 4 121 96 84 33 27 29 7 6 133 105 91 39 31 34 6 10 140 109 94 45 36 40 6 16 163 125 107 54 42 48 6 25-127 108-42 - - 35-141 - - 48 - - 50-157 - - 53 - - 70-165 - - 55 - - 95-184 - - 60 - - 120-189 - - 62 - - 150-184 - - 61 - - Partial capacitances in nf/km TFXI and TIOI TFXI in nf/km C12 C13 Number of cores mm 2 2 3 4 4 1.5 58 28 41 10 2.5 64 43 46 9 4 72 48 51 9 6 78 52 56 9 10 88 59 62 8 16 98 66 70 8 25-65 - - 35-71 - - 50-72 - - 70-76 - - 95-82 - - 120-83 - - 150-81 - - Table 6 TIOI in nf/km C11 C12 C13 Number of cores mm 2 2 3 4 2 3 4 4 1.5 79 61 52 26 21 23 8 2.5 88 68 57 30 23 26 8 4 99 76 64 33 26 30 8 6 108 82 70 37 29 33 7 10 123 93 79 42 32 38 7 16 147 111 94 47 36 43 6 25 152 115 98 47 36 43 6 35 173 130 110 51 39 47 6 50-125 105 51 39 47 6 70-136 114 54 41 50 5 95-151 127 57 43 54 5 120-158 - - 44 - - 150-158 - - 44 - - Remark: Measurements in practice have shown that the scatter of partial capacitances of XLPE-insulated cables can amount to 40% DRAKA Product information MOG 2010 23

Draka Kabel B.V. Hamerstraat 2-4 1021 JV Amsterdam Postbus 1013 1000 BA Amsterdam T. 020 637 99 11 F. 020 637 93 63 kdn-info@draka.com www.drakaservice.nl