Characterization of High Resolution Photographic Emulsion BB640 by Holographic Methods

Similar documents
Silver halide sensitized gelatin derived from BB-640 holographic emulsion

Recording and reconstruction of holograms

Diffraction Efficiency Adjustment to Record High Quality Color Holograms

Gerhard K. Ackermann and Jurgen Eichler. Holography. A Practical Approach BICENTENNIAL. WILEY-VCH Verlag GmbH & Co. KGaA

Holography as a tool for advanced learning of optics and photonics

Holography (A13) Christopher Bronner, Frank Essenberger Freie Universität Berlin Tutor: Dr. Fidder. July 1, 2007 Experiment on July 2, 2007

ECEN 4606, UNDERGRADUATE OPTICS LAB

ECEN 4606, UNDERGRADUATE OPTICS LAB

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

DEVELOPMENT PROCESS FOR PVCz HOLOGRAM

Effects of Photographic Gamma on Hologram Reconstructions*

KODAK EKTACHROME 64T Professional Film

A Visual Indication of Environmental Humidity Using a Colour Changing Hologram Recorded in a Self-developing Photopolymer

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

Compound Holographic Optical Element System for Splitting and Concentrating Solar Spectrum on Laterally- Arranged Multiple Band Gap Solar Cells

A Study of Vibrating Objects using Time-Average Holographic Interferometry

Study of the stability in holographic reflection gratings recorded in PVA/AA based photopolymer

Holographic optical elements recorded in silver halide sensitized gelatin emulsions. Part I. Transmission holographic optical elements

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Electrical Engineering and Computer Science

PhysFest. Holography. Overview

Photonics and Optical Communication

PROCEEDINGS OF SPIE. Teaching multilayer optical coatings with coaxial cables. J. Cos, M. M. Sánchez-López, J. A. Davis, D. Miller, I. Moreno, et al.

Exposure schedule for multiplexing holograms in photopolymer films

EASTMAN TRI-X Reversal Film 7278

Holography. Introduction

LEOK-3 Optics Experiment kit

Holographic RAM for optical fiber communications

KODAK AEROCHROME III MS Film 2427

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

Silver-Halide Recording Materials

UO-11 RECORDING and RECONSTRUCTING of HOLOGRAMS

KODAK EKTACHROME 64 Professional Film

TL2 Technology Developer User Guide

KODAK PROFESSIONAL EKTACHROME Films E100G and E100GX Grain as Fine as Your Art.

KODAK EKTACHROME 64 Professional Film

Basics of Holography

KODAK EKTACHROME 100 Plus Professional Film

Reflection holograms in a PVA/AA photopolymer: Several compositions

Chapter 36: diffraction

Spherical Beam Volume Holograms Recorded in Reflection Geometry for Diffuse Source Spectroscopy

PHOTOPOLYMER FOR RECORDING HOLOGRAMS. Hideo Tanigawa, Taichi Ichihashi, and Takashi Matsuo*

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

Testing Aspherics Using Two-Wavelength Holography

Generation of diffractive optical elements onto a photopolymer using a liquid crystal display

Using double-exposure holographic techniques to evaluate the deformation of an aluminum can under stress

Chapter 17: Wave Optics. What is Light? The Models of Light 1/11/13

EASTMAN PLUS-X Reversal Film / 7276

Defense Technical Information Center Compilation Part Notice

CONFERENCE PROCEEDINGS

Research Article Basic Holographic Characteristics of a Panchromatic Light Sensitive Material for Reflective Autostereoscopic 3D Display

Use of Computer Generated Holograms for Testing Aspheric Optics

KODAK EKTACHROME 160T Professional Film / EPT

Lecture 9. Lecture 9. t (min)

Large aperture tunable ultra narrow band Fabry-Perot-Bragg filter

Longitudinal mode selection in laser cavity by moiré volume Bragg grating

PAPER No. 7: Criminalistics & Forensic Physics MODULE No. 31: Black & White & Colour Film Processing and Printing. and Printing

KODAK PROFESSIONAL EKTACHROME Film E100VS

Transmitting Light: Fiber-optic and Free-space Communications Holography

The Photorefractive Effect

AP B Webreview ch 24 diffraction and interference

Invited Paper. recording. Yuri N. Denisyuk, Nina M. Ganzherli and Irma A. Maurer

Electronically switchable Bragg gratings provide versatility

EASTMAN EXR 200T Film / 5293, 7293

KODAK PROFESSIONAL EKTACHROME Film E100VS

KODAK Panchromatic Separation Film 2238

Integrated Photonics based on Planar Holographic Bragg Reflectors

Investigation of Photopolymer-based Holographic Optical Elements for Solar Applications

Chapters 1-3. Chapter 1: Introduction and applications of photogrammetry Chapter 2: Electro-magnetic radiation. Chapter 3: Basic optics

EASTMAN EXR 200T Film 5287, 7287

Physics 3340 Spring 2005

KODAK PRIMETIME 640T Teleproduction Film / 5620,7620

Obtaining relief structures in silver halide materials

HOLOGRAPHIC DATA STORAGE

EASTMAN EXR 500T Film 5298

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

Important performance parameters when considering lasers for holographic applications

ABSTRACT 1. INTRODUCTION

Developing characteristics of Thermally Fixed holograms in Fe:LiNbO 3

Thermal tuning of volume Bragg gratings for high power spectral beam combining

The range of applications which can potentially take advantage of CGH is very wide. Some of the

4-2 Image Storage Techniques using Photorefractive

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

PHY 431 Homework Set #5 Due Nov. 20 at the start of class

LOS 1 LASER OPTICS SET

Advances in holographic replication with the Aztec structure

SUPPLEMENTARY INFORMATION

Holographic 3D imaging methods and applications

HOLOGRAPHY EXPERIMENT 25. Equipment List:-

KODAK PROFESSIONAL T-MAX P3200 Black & White Negative Film

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Wavelength Stabilization of HPDL Array Fast-Axis Collimation Optic with integrated VHG

Topic 7: Photographic Process

J. C. Wyant Fall, 2012 Optics Optical Testing and Testing Instrumentation

KODAK PROFESSIONAL ELITE COLOR Films / 200 and 400

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

KODAK Infrared AEROGRAPHIC Film 2424

Design and Analysis of Resonant Leaky-mode Broadband Reflectors

Radiology. Radiograph: Is the image of an object made with use of X- ray instead of light.

PROCEEDINGS OF SPIE. Making optics appealing in Colombia through low-cost experiments with lasers

International Journal of Scientific & Engineering Research, Volume 4, Issue 8, August ISSN Design and analysis Narrowband filters

Transcription:

24 International Symposium on Silver Halide Technology Characterization of High Resolution Photographic Emulsion BB64 by Holographic Methods M. Ulibarrena, L. Carretero, S. Blaya, R. Madrigal and A. Fimia epartamento de Ciencia y Tecnologia de Materiales Universidad Miguel Hernandez 322 Elche, Spain Abstract The gap created in the last decade in the market of fine and ultra-fine grain silver halide emulsions with the withdrawal of the historical producers was filled in recent years with new products and manufacturers. We have studied with holographic techniques the emulsion BB64, with a mean grain size of 2 nm, and we have found out that we can easily reproduce the results obtained with the discontinued materials. Additionally, we have found new features with processing techniques not used with former emulsions, obtaining densities higher than 11. We have obtained very good results with spatial frequencies higher than 7 l/mm and diffraction efficiencies higher than 7 %. The material, in its monochromatic or panchromatic version has been used to spatially and spectrally multiplex holograms obtaining very high diffraction efficiencies. Emulsion characteristics Ultra-fine grain holographic emulsion BB64, manufactured by British company Colourholographics Ltd., has a nominal grain size of 2 nm [1] and its sensitivity in the red region of the spectrum, with a transmittance of the unexposed emulsion at 632.8 nm of 71.3 %. Thickness and mean refraction index of unexposed BB64 plates have been calculated from interferometric data with a thin film resonance method. Values obtained for unexposed emulsion are a thickness of 9.3 microns, a mean refraction index of 1.579 and a attenuation coefficient of 33.4 cm 1. Methodology Prior to exposure, plates need to be presensitised to recover or even increase the original sensitivity. Several procedures were used, but the best one was a 3% Triethanolamine (TEA) water solution bath followed by a water bath. After that, plates were dried with a photographic roll and warm air and left in the exposing room to cool down for half an hour in normal laboratory conditions. Plates were holographically characterized for recording transmission and reflection holograms. The first was done by using the plates for recording volume unslanted holographic transmission gratings with a spatial frequency of 12 lp/mm obtained by the interference of two symmetrically incident collimated laser beams from a p polarized He-Ne laser (λ = 632.8 nm) at an angle of 22.3 o each. The reflection study was done recording volume unslanted holographic reflection gratings with a spatial frequency of 4992 l/mm obtained with a normal incident single collimated He-Ne beam in a enisyuk configuration. For both studies, plates were mounted on a computer controlled motorized holder which enable us to record 9 gratings with different exposure energies on a 2.5 x2.5 plate. Exposed plates were processed with a variety of developers, fixers and bleaches. The developers used were: (Ascorbic Acid 18 g/l + Sodium Carbonate 6 g/l), P ( with.5 g/l of Phenidone), C (Ascorbic Acid 5 g/l + Sodium Carbonate 3 g/l + Pyrocathecol 1 g/l + Sodium Sulphite 5 g/l + Urea 5 g/l), PM ( with.5 g/l of Phenidone + 2 g/l of Methol), ( 5 g/l + Sodium Sulphite 15 g/l + Sodium Carbonate 6 g/l), Kodak 19 and Kodak 8. The fixer used in the density studies was non-hardening Kodak F-24. Bleachings used were: direct rehalogenating ferricianide bleach, modified fixation-free rehalogenating bleach Kodak R-1 (Potassium ichromate 2 g/l + Sulphuric Acid 1 cc/l + Potassium Bromide 35 g/l) and solvent bleach Kodak R- 9 (Potassium ichromate 2 g/l + Sulphuric Acid 1 cc/l). After bleaching, plates were washed and soaked in deionized water with some drops of Kodak Photoflo 2 solution and Acetic Acid to prevent printout, and dried in cited normal laboratory conditions. ensities were calculated from transmission measurements taken with a solid state detector ranging from 2 W atts/cm 2 to.1 nanow att/cm 2. The probe beam was a slowly expanded laser beam with an intensity of 25

24 International Symposium on Silver Halide Technology over 2 mw/cm 2. With this configuration it is not possible to measure transmission values corresponding to densities higher than 11.3, so all graphics will show that limit. Transmission values of. nw/cm 2 were measured, indicating higher densities outside the limits of our detector. iffraction efficiency (E) measurements of the bleached recordings were made using a collimated He-Ne laser beam at the grating Bragg angle. Results The set of developers and bleaches mentioned above have been used to compare the holographic characteristics of the diffraction gratings. evelopers evelopers used were compared by their measured -LogE curves with the holographic transmission setup. Fig. 1 present the different -Log E curves for each of the developers described above. Plates were fixed with non-hardening fixer Kodak F-24. Kodak 8 curve has been omitted since it will be discussed separately in a further section. Maxima densities were obtained for and C developers, with values of 7.9 (E=192 µj/cm 2 ) and 8.1 (E=384 µj/cm 2 ) respectively. 9 8 7 P C PM -19 bleach was used with the fixed plates after the measurements of the densities have been performed. Fixation free rehalogenating bleach R-1 study was done with a different set of plates. Solvent (reversal) bleach will be discussed later. Figs. 2 and 3 show the results. For the ferricianide bleach, the highest diffraction efficiencies obtained were for developer -19 with 73% (768 µj/cm 2 ), P with 69.2% (384 µj/cm 2 ) and with 66.1% (48 µj/cm 2 ). For the R-1 bleach, the best results were for C, with 69.9% (128 µj/cm 2 ), followed by the pyrogalol developer, with 68.2% (64 µj/cm 2 ) and with 64.3% (96 µj/cm 2 )[2]. 1 8 6 4 2 P C PM -19 1 1 1 1 Figure 2: η-log E curves of holographic transmission gratings recorded on emulsions BB64 developed with, P, C, PM, pyrogalol and -19 and bleached with ferricianide direct bleach. 6 5 4 3 2 1 8 P C PM 1 6 1 1 1 1 1 Figure 1: -Log E curves corresponding to emulsion BB64 developed with, P, C, PM, pyrogalol and Kodak -19 developers. 4 2 Bleaches In order to study the holographic response of the material, the above set of developers was applied to holographic transmission gratings with the three bleachings methods described in the former section. The direct ferricianide 1 1 1 1 Figure 3: η-log E curves of holographic transmission gratings recorded on emulsions BB64 developed with, P, C, PM, pyrogalol and -19 and bleached with fixation free rehalogenating bleach R-1. 26

24 International Symposium on Silver Halide Technology Another study was done with holographic reflection gratings using only fixation free rehalogenating bleach R- 1. In this study, performed at a later stage than the transmission described above, the presensitizing was done with 3% solution of TEA, so that the exposure energy values presented will be lower than expected. Solvent and direct bleaches were rejected in this case since both processes eliminate material from the emulsion, thus causing a distortion of the grating by the shrinkage of the layer. The results are presented in fig. 4. Best values were 72,1% (9 µj/cm 2 ) for developer, 68,3% (6 µj/cm 2 ) for P, 71,1% (18 µj/cm 2 ) for C and 67,8% (9 µj/cm 2 ) for. 1 8 P C High densities with -8 Another non conventional result was the very high densities obtained with the high contrast developer Kodak 8 when exposed to an holographic transmission setup. ensities obtained were above the detection limits of our measurements devices, which is 11.3. Figure 5 shows the results of the anomalous -Log E[3] curve together with the holographic response of the direct bleached emulsion with ferricianide and of the solvent bleach R-9. Both bleaches were selected for extracting direct information from the holographic structure recorded, since they do not present diffusion processes. The analysis of the resulting E curves, with a double peak for the direct bleach and a single maximum for the solvent bleach right in the intermediate energy zone of the direct bleach led us to postulate a new image formation mechanism[4]. 6 12 E direct bleach(%) E reversal bleach(%) 1 4 1 8 8 III 6 2 6 E(%) 4 5 1 15 2 E (µj/cm 2 ) Figure 4: η-log E curves of holographic reflection gratings recorded on emulsions BB64 developed with, P, C and, bleached with fixation free rehalogenating bleach R-1. Special results 4 2 I II 2 1 1 1 1 1 E (µj/cm 2 ) Figure 5: BB64 plates processed with Kodak 8 developer. - Log E curve ( ), E - Log E curve for non-hardening fix followed by ferricianide rehalogenating bleaching ( ) and E - Log E curve for Kodak R-9 reversal bleaching ( ). The above results may be considered standard for a silver halide emulsion, although the diffraction efficiency figures are quite good. Nevertheless, we have obtained results that were not found for former classical emulsions. The most remarkable of them follow. Solvent bleach R-9 The best diffraction efficiencies for transmission gratings were not those presented in the former section, but those obtained with developer and reversal bleach Kodak R-9. Values went as high as 82.9% for an exposure energy of 65 µj/cm 2, and with very clear and clean recordings[2]. Exposure of BB64 with blue Based on the absorption band of silver halide, located near 4 nm, we have tried using red sensitive BB64 emulsion for recording reflection holograms with a He-Cd laser (wavelength 442 nm). Spatial frequency was higher than 7 l/mm. Plates had been presensitized with 2 minutes in the 3% TEA solution followed by 6 minutes in the deionized water bath. Fig. 6 shows the spectral response of the best grating, with a E of 5,5% at an exposure energy of 6 µj/cm 2. Replay wavelength is 44.1 nm. 27

24 International Symposium on Silver Halide Technology 1 Panchromatic emulsions BBVPan T (%) 8 6 4 2 4 45 5 55 6 λ(nm) Figure 6: Spectral response of a unslanted reflection grating recorded with BB64 emulsion using a He-Cd laser (442 nm). Exposure energy is 6 µj/cm 2. A still non commercial panchromatic version of BB64, denominated BBVPan, was tested for recording multiple reflection gratings by the multiplexing method with three laser wavelengths (He-Ne - 632.8 nm, Nd-Yag - 532 nm and He-Cd - 442 nm) in order to characterize it for color holography. The best result was obtained with a sequence of exposures with energies of 15 (442 nm) + 25 (532 nm) + 12 (632.8 nm) µj/cm 2, for which the diffraction efficiencies of each band are balanced, with 52% for the red, 62% for the green and 57% for the blue wavelength, with the corresponding spectral transmission curve shown in fig. 8[5]. 1 15+25+12 µj/cm 2 8 Hologram multiplexing The results obtained with the solvent bleach and the developer 8 points towards a high index modulation capability of this material. To check this properties we have tested hologram multiplexing in a single layer of emulsion. The most outstanding result is the superposition of reflection and transmission gratings in the same plate, to obtain three dimensional structures[6]. Fig. 7 shows the simulation of the refractive index of the structure obtained after multiplexing one unslanted volume reflection grating and two crossed unslanted volume transmission gratings. iffraction efficiencies were 52% for the reflection grating and 6% for each of the transmission gratings. T (%) 6 4 2 4 45 5 55 6 65 7 λ(nm) Figure 8: Transmission spectrum of the multiplexed holographic reflection grating recorded on a single BBVPan plate. References Figure 7: Simulation of the refractive index three dimensional structure obtained by multiplexing one reflection and two transmission diffraction gratings. 1. www.colourholographic.com. 2. Manuel Ulibarrena, María J. Méndez, Luis Carretero, Roque Madrigal and Antonio Fimia, Comparison of direct, rehalogenating and solvent bleaching processes with BB64 plates, Appl. Opt., 41(2), 412 (22). 3. M. Ulibarrena, M. Mendez, S. Blaya and A. Fimia, Anomalous -Log E curve with high contrast developer Kodak 8 on ultra fine grain emulsion BB64, Opt. Express, 9(12), 645 (21). 4. Manuel Ulibarrena, María J. Méndez, Salvador Blaya, Roque F. Madrigal, Luis Carretero and Antonio Fimia, Image formation mechanism of ultra fine grain emulsion BB64 processed with high contrast developer 8, J. of Imaging Sci. Techn., 47(1), 69 (23). 5. Manuel Ulibarrena, Luis Carretero, Roque F. Madrigal, Salvador Blaya and Antonio Fimia, Multiple band holographic reflection gratings recorded in new ultra-fine grain emulsion BBVPan, Opt. Express, 11(25), 3385 (23). 6. L. Carretero, M. Ulibarrena, P. Acebal, S. Blaya, R. Madrigal and A. Fimia, Multiplexed holographic gratings for fabricating 3 photonic crystals in bb64 photographic emulsions, Optics Express, 12(13), 293 (24). 28

24 International Symposium on Silver Halide Technology Biography Manuel Ulibarrena received his MS in physics from Universidad de Santiago de Compostela, Spain, in 1986 and his Ph at the epartamento de Ciencia y Tecnologia de Materiales of Universidad Miguel Hernandez de Elche, Spain, in 23. He is currently an associate professor of Nondestructive Testing in the same institution. He has been involved in holographic research since 1985, with experience in holographic displays, holographic optical elements and holographic recording materials research. His current area of interest is research on silver halide holographic recording materials. 29