DS-0321 FFT Analysis Software

Similar documents
DS-0322 Tracking Analysis Software Operation manual Basic Operation procedure for Constant-width Tracking Analysis

DS-2000 Series Measurement of Frequency Response Function

Portable FFT Analyzer CF-9200/9400

ME scope Application Note 02 Waveform Integration & Differentiation

Simplified Operation of CF-4500 FFT Comparator

UCE-DSO210 DIGITAL OSCILLOSCOPE USER MANUAL. FATIH GENÇ UCORE ELECTRONICS REV1

EENG-201 Experiment # 4: Function Generator, Oscilloscope

UCE-DSO212 DIGITAL OSCILLOSCOPE USER MANUAL. UCORE ELECTRONICS

Faculty of Engineering, Thammasat University

SignalCalc Drop Test Demo Guide

Lab Reference Manual. ECEN 326 Electronic Circuits. Texas A&M University Department of Electrical and Computer Engineering

FT-2500 Advanced Tachometer Operation manual

Laboratory Experiment #1 Introduction to Spectral Analysis

EE 3302 LAB 1 EQIUPMENT ORIENTATION

Software. DS-3000 Series. Sound and Vibration Real-time Analysis System. Supports. Hardware. Multi-Channel Data Station. DS Series

ECE65 Introduction to the Function Generator and the Oscilloscope Created by: Eldridge Alcantara (Spring 2007)

Getting Started. MSO/DPO Series Oscilloscopes. Basic Concepts

LAB #3: Virtual Instruments; Behavior of Second-Order Systems

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

The University of Jordan Mechatronics Engineering Department Electronics Lab.( ) Experiment 1: Lab Equipment Familiarization

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

LAB 8: Activity P52: LRC Circuit

PHY 1405 Conceptual Physics I Making a Spring Scale. Leader: Recorder: Skeptic: Encourager:

Oscilloscope and Function Generators

SigCal32 User s Guide Version 3.0

SETUP I: CORD. Continuous Systems

Physics 3 Lab 5 Normal Modes and Resonance

1. Hand Calculations (in a manner suitable for submission) For the circuit in Fig. 1 with f = 7.2 khz and a source vin () t 1.

Frequency and Time Domain Representation of Sinusoidal Signals

PHYSICS LAB. Sound. Date: GRADE: PHYSICS DEPARTMENT JAMES MADISON UNIVERSITY

LABORATORY 4. Palomar College ENGR210 Spring 2017 ASSIGNED: 3/21/17

Rigol DSA1000 Application Note

Lab 1B LabVIEW Filter Signal

Free vibration of cantilever beam FREE VIBRATION OF CANTILEVER BEAM PROCEDURE

Procedures Guide. Tektronix. HDMI Sink Instruments Differential Impedance Measurement

ME scope Application Note 01 The FFT, Leakage, and Windowing

EE 210 Lab Exercise #3 Introduction to PSPICE

Lab 3: RC Circuits. Construct circuit 2 in EveryCircuit. Set values for the capacitor and resistor to match those in figure 2 and set the frequency to

Vibration Analyzer VA-12. Vibration Analyzer VA-12

ECE4902 Lab 5 Simulation. Simulation. Export data for use in other software tools (e.g. MATLAB or excel) to compare measured data with simulation

Take Control. Introduction. Control Principles

Studuino Icon Programming Environment Guide

LAB #7: Digital Signal Processing

Good Modal Practices

Fourier Theory & Practice, Part II: Practice Operating the Agilent Series Scope with Measurement/Storage Module

Software. DS-3000 Series. Sound and Vibration Real-time Analysis System. Supports. Hardware. Multi-Channel Data Station. DS Series

External Source Control

Linear Motor Test Sequence

Experiment #2: Introduction to Lab Equipment: Function Generator, Oscilloscope, and Multisim

Objectives. Abstract. This PRO Lesson will examine the Fast Fourier Transformation (FFT) as follows:

Measurement of Amplitude Modulation AN 6

Experiment 1 Introduction to Simulink

How to source exponential waveform

IX Feb Operation Guide. Sequence Creation and Control Software SD011-PCR-LE. Wavy for PCR-LE. Ver. 5.5x

DT 9818 Waveform-Generator. Hardware Trigger Version. Operating Manual. Version 2.0. May Page 1 of 21

1.5k. (a) Resistive Circuit (b) Capacitive Circuit

Software. DS-3000 Series. Sound and Vibration Real-time Analysis System. Supports. Hardware. Multi-Channel Data Station. DS Series

Experiment: P34 Resonance Modes 1 Resonance Modes of a Stretched String (Power Amplifier, Voltage Sensor)

Tektronix digital oscilloscope, BK Precision Function Generator, coaxial cables, breadboard, the crystal earpiece from your AM radio kit.

Time-Varying Signals

Laboratory Experiment #2 Frequency Response Measurements

Page 21 GRAPHING OBJECTIVES:

Lab 4 Projectile Motion

Lab 4 Ohm s Law and Resistors

Design and Simulation of RF CMOS Oscillators in Advanced Design System (ADS)

16 Histograms. Using Histograms to Reveal Distribution

SDC. AutoCAD LT 2007 Tutorial. Randy H. Shih. Schroff Development Corporation Oregon Institute of Technology

Experiment 2: Electronic Enhancement of S/N and Boxcar Filtering

DSO5000P Series Digital Storage Oscilloscope User Manual. (Version 1.1)

Fluke 125. Getting Started. Industrial ScopeMeter

EE 201 Function / Arbitrary Waveform Generator and Oscilloscope Tutorial

Step 1: Set up the variables AB Design. Use the top cells to label the variables that will be displayed on the X and Y axes of the graph

Activity P52: LRC Circuit (Voltage Sensor)

System Inputs, Physical Modeling, and Time & Frequency Domains

2 Oscilloscope Familiarization

PN9000 PULSED CARRIER MEASUREMENTS

Spectrum Analyzer TEN MINUTE TUTORIAL

Velleman Arbitrary Function Generator: Windows 7 by Mr. David Fritz

Lab 11. Vibrating Strings

J. La Favre Fusion 360 Lesson 5 April 24, 2017

The Discussion of this exercise covers the following points: Filtering Aperture distortion

ECG Analysis using the Offline Averaging Mode

Cornerstone Electronics Technology and Robotics Week 21 Electricity & Electronics Section 10.5, Oscilloscope

DL9040/DL9140/DL9240 Series

Lab 2b: Dynamic Response of a Rotor with Shaft Imbalance

with MultiMedia CD Randy H. Shih Jack Zecher SDC PUBLICATIONS Schroff Development Corporation

Ph 3455 The Franck-Hertz Experiment

Data Sheet. Digital Storage Oscilloscope. Features & Benefits. Applications. Ease-of-Use Feature DSO5202BMT DSO5102BMT DSO5062BMT

m+p Analyzer Revision 5.2

Precalculations Individual Portion Introductory Lab: Basic Operation of Common Laboratory Instruments

The behavior of the FastADC in time domain

ME 365 EXPERIMENT 1 FAMILIARIZATION WITH COMMONLY USED INSTRUMENTATION

DL9500/DL9700 Series. Digital Oscilloscope. IM E 3rd Edition

SVAN A DESCRIPTION OF GROUND VIBRATION FUNCTION. SVANTEK Sp. z o.o. WARSAW, July 2014 SVANTEK

SDI. Table of Contents

DiGi++ Noise Meter. Main functions

ET 304A Laboratory Tutorial-Circuitmaker For Transient and Frequency Analysis

Vt^ro^es^piimunf Runfflng^Z0om Function For Audio And Noise Spectrum Analysis

Drawing Bode Plots (The Last Bode Plot You Will Ever Make) Charles Nippert

Pioneering Partnership Performance

Transcription:

DS-0321 FFT Analysis Software Operation manual Damping factor measurement using Hilbert transform ONO SOKKI CO., LTD.

The DS-0321 FFT Analysis software has the Hilbert operation function. A time envelope of a time-domain waveform can be displayed by means of Hilbert transform. This manual describes measurement procedure of damping ratio from vibration damping waveform by means of Hilbert transform function in the DS-0321 FFT Analysis software. As in the system configuration in the figure below, with the accelerometer connected to Ch2 of DS-3000 (with Ch1 unused), FFT Analysis is executed using DS-0321 FFT Analysis software. This manual describes functions with the focus on what behavior will result from a single operation, and you are recommended to try various actions on the instrument. Basic operations of the DS-3000 software are mostly executed in the Configuration window. As the operations in the Configuration window are correspondent with those of the Main menu, the Main menu operations are not included in this manual. For details on the Configuration window operations, refer to the respective procedure manuals ( Basic operation procedure for Configuration Setting and Basic operation for display of Configuration Window ). In this instruction manual, a series of clicking operations is described, for example, as follows; "Click "File" > "Project File"> "New Project" > " ". System Configuration Connect the NP-3000 series accelerometer directly to the CH1 terminal by using an NP-0021 conversion connector. NP-0021 Conversion connector NP-3000 Series accelerometer -1-

Operation Flow -1 Startup -2 Opening a New Project -3 Changing the Number of Screen Partitions -4 Setting the Input Source -5 Setting CCLD -6 Calibrating the Measurement Unit -7 Setting the Window Function -8 Checking the Waveform -9 Setting the Trigger -10 Starting Measurement -11 Setting the Hilbert Transform -12 Hilbert Transform from the Stored Data -2-

Operation Procedures -1 Startup Connect each device as described in the System Configuration, turn the power on, and start the DS-0321 FFT Analysis software. -2 Opening a New Project 1 From the main menu, click "View" > "Configuration" to open the "Configuration" window. 2 In the "Configuration" window, click "File" > "Project File" > "New Project" > " ". This operation erases the current settings and opens a new project with initial settings. -3 Changing the Number of Screen Partitions 1 Click the Selecting partition numbers tool at the upper part of the graph window and, here, set the triple-partition display mode as shown below. -3-

-4 Setting the Input Source Set the graph in the upper screen partition to the "CH1 Time view. Set that in the middle screen partition to the CH1 Power Spectrum view, and set that in the lower partition to the "CH1 Hilbert Transform" view. 1 Click in the upper graph to activate it. The graph is enclosed with orange box lines. 2 Select CH1 using the tool for selecting an input source above the graph window. From the pull-down menu on the right to it, select Time. 3 In a similar manner, click in the middle graph, select CH1 for input source, and select Power Spectrum for the display waveform. 4 In a similar manner, click in the lower graph, select CH1 for input source, and select Hilbert Transform for the display waveform. -4-

When you click in the graph, it is enclosed with orange box lines to show that it is active. The settings in the "Configuration" window are reflected in the active screen partition, except for the measurement items related to all the channels, including the frequency and voltage ranges. -5 Setting CCLD 1 In the "Configuration" window, click "Input/Output Setting" > "Input Setting" > Condition Setting" dialog box opens.. The "Input 2 In the Input Condition Setting dialog box, put a check mark in the "CCLD" box of "CH1". This allows power of "+24V/4mA" to be supplied from CH1 to the accelerometer. The signal will be input properly. -5-

-6 Calibrating the Measurement Unit 1 Calibrate the measurement unit so that the reading along the Y axis can be directly read in the vibration unit (m/s 2 ). (When the measurement for the purpose of damping ratio, unit calibration is not required.) 2 For example, read Voltage Sensitivity: 1.03 mv/ms -2 from the Calibration Chart attached to the accelerometer you use. 3 In the "Configuration" window, click ""Input/Output Setting" > "Unit/Cal Setting" > " Setting" dialog box opens. ". The "Cal 4 Put a check mark in the "EU" box of "CH1" in the "Cal Setting" dialog box. Then, set the Unit Name: m/s, EU value: 0.00103 and EU Type: V/EU. -7 Setting the Window Function Set the window function Rectangular to obtain the damping ratio from vibration damping waveform using Hilbert Transform function. 1 In the "Configuration" window, click "Input/Output Setting" > "Window Function Setting" > " ". The "Window Function Setting" dialog box opens. 2 Select CH1: Rectangular from the pull-down menu on the Window Function Setting dialog box -6-

-8 Checking the Waveform Push Start button and apply impact as a trial to check the acceleration time axis waveform and its power spectrum are displayed properly. Also adjust the frequency range and voltage range properly. In this example, the frequency range is set to 4 kh, voltage range is set to 1 Vrms according to the 1-order of basic frequency. -7-

-9 Setting the Trigger Trigger function is a function which starts waveform sampling based on a certain trigger level of a signal. This function makes it possible to display whole of free vibration damping waveform on a screen after hitting a desired waveform portion. Under [START] status, take trial excitation repeatedly switching [TRIG] button ON/OFF. While seeing the waveform amplitude, set the trigger level. 1 In the Configuration window, click Input/Output Setting > Trigger Condition Setting and set Trigger Condition Setting: Repeat, Trigger Source: Internal. By this setting, the waveform is sampled every time the trigger is applied. 2 Trigger Condition Setting > Internal Trigger > box. to open Internal Trig Setting dialog 3 Red cross line will appear when you click within the waveform graph in Internal Trig Setting dialog box. The intersection point is a position of the trigger point. With taking trial excitations, set the trigger point temporarily so that the damping waveform is within the graph as follows. -8-

4 After the setting completes, press OK button to close Internal Trig Setting dialog box. When the damping time is long and the waveform is not completed within the graph, change the number of samplings. In the Configuration window, click Input/Output Setting > Sampling Condition Setting > Sampling Point Count and change to the larger value such as 4096. -9-

-10 Starting Measurement 1 With [START] button ON, turn the [TRIG] button ON to start measurement. 2 Hit the measurement object several times and turn the [STOP] button ON when the desired waveform is obtained. However, it may not operate correctly, set again the trigger referring the section 9 [Setting thetrigger]. Be careful not to hit too strongly so that the signal does not go over the voltage range, the waveform does not get distorted. -11 Setting Hilbert Transform Specify the band to interpose the basic frequency and perform Hilbert transform to obtain the damping ratio. 1 Click the Hilbert transform data graph to activate. 2 In the Configuration window, click Analysis Setting > Hilbert Operation, and click the right button of Band Limitation to set it ON. The Hilbert transform data may become nearly straight line because the [Band Limitation] or [Taper] is set. 3 Hilbert Operation > Waveform Disp Setting > Spectrum Monitoring dialog box. to open the Hilbert Conv Data Power 4 In Hilbert Conv Data Power Spectrum Monitoring dialog box, click Lower button and set the red line cursor to the lower limit of the basic frequency (natural frequency). 5 In the same manner, click Upper button and set the red line cursor to the upper limit of the basic frequency (natural frequency). Finally the frequency band interposed between upper and lower limit frequencies is limited, Hilbert transform is performed. 6 After setting is complete, click OK button to close Hilbert Conv Data Power Spectrum Monitoring dialog box. -10-

7 Set the cursor setup tool in the lower graph window Delta, click the lower position that you want to perform damping ratio transform, and click [ ] button. The line color changed from red to pink. Next, click the upper limit position to display red line. The damping ratio is obtained from the upper and lower limit positions, and [Log.d], [Damp], and [Freq] are displayed. If the Hilbert conversion data is not linear, try to change the band frequency following the above procedure 3 to 5. The measurement will be difficult when Hilbert conversion data does not become straight line for several reasons; there is no peak (not apparent natural frequency) in the power spectrum or there are several peaks in the power spectrum because the shape of the measurement object is complicated. -11-

< Remarks > The way to calculate the damping ratio from Hilbert conversion data Logarithmic decrement Damping ratio :Resonance frequency ΔX and ΔY : X and Y axes values of two points specified by delta cursor. -12. Hilbert transform from the stored data The damping time-axis waveform stored in DAT format can be used for Hilbert transform. Store the time-axis waveform data of section-11 in DAT format, and reproduce the DAT file (hirbert_001.dat) on the upper, middle, and lower screen. The following screen shows the time-axis waveform, power spectrum and Hilbert transform data. -12-

-13- End