Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER

Similar documents
OCULUS Keratograph 4. Topographer. We focus on progress

ATLAS Corneal Topography System

Wave Front Topography. ReSeeVit Evolution Topography Module for Modi Topographer

THE BEST OF BOTH WORLDS Dual-Scheimpflug and Placido Reaching a new level in refractive screening

Refractive Power / Corneal Analyzer. OPD-Scan III

(495) (495)

Aberrometry in Clinical Practice

OCULUS Pentacam AXL Always an Axial Length Ahead

Optical Path Difference Scanning System OPD-Scan II ARK-10000

DesiGneD and ManUFaCTUreD in italy The sharpest vision.

THE SHARPEST VISION. DESIGNED AND MANUFACTURED IN ITALY

OCULUS Keratograph 5M Topographer

OCULUS Easygraph. Topographer. We focus on progress

OCULUS Easygraph. So Small and Yet a Topographer. Small, but Efficient As a Big One. All Important Parameters at a Glance

Principles and clinical applications of ray-tracing aberrometry (Part II)

OCULUS Keratograph 5M Topographer


CA-800 Corneal Analyzer

CA-800 Corneal Analyzer

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

The Aberration Structure of the Keratoconic Eye

The First True-Color Wide-Field Confocal Scanner

Customized intraocular lenses

Corporate Perspective Alcon Unanswered Technical Challenges that Still Need to be Overcome

Impressive Wide Field Image Quality with Small Pupil Size

Optical Biometer AL-Scan

case report Scleral lens fit based on OCT data

Technicians & Nurses Program

Unique Aberration-Free IOL: A Vision that Patients

Optical Biometer AL-Scan

Optical Biometer. AL-Scan. US Edition

The First True Color Confocal Scanner on the Market

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

Optical Biometer AL-Scan

The New Corvis ST. Evaluation of corneal biomechanical response, tonometry and pachymetry. Biomechanical Response

Raise your expectations. Deliver theirs.

By Dr. Abdelaziz Hussein

Soft CL Multifocals Design and Fitting. Soft Multifocal Lens Designs. Issues Surrounding Multifocals. Blur Interpretation. Simultaneous Vision Designs

Improving Lifestyle Vision. with Small Aperture Optics

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

The First True Color Confocal Scanner

Optometrist Private ophthalmologists

FOR PRECISE ASTIGMATISM CORRECTION.

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Headline. IOLMaster. Subline. The gold standard in biometry

Medical Dpt., Medicem Prague, Czech Republic 2. Medicem Institute, Kamenne Zehrovice, Czech Republic 3

Wave-Front Analyzer KR-1W

Keratoconus is one of the most leading causes for visual disability

Fitting Manual Use with kerasofttraining.com

FITTING GUIDE PRACTITIONER S ROSE K2 KC ROSE K2 NC ROSE K2 IC ROSE K2 PG NIPPLE CONE IRREGULAR CORNEA POST GRAFT

Clinical Evaluation 3-month Follow-up Report

Medical Photonics Lecture 1.2 Optical Engineering

INSTRUCTIONS FOR USE CORNEAL ANALYZER CA-800 CORNEAL ANALYZER

Optical Coherence Tomography Retina Scan Duo

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

ClearKone Restoring vision. Changing lives.

Image Modeling of the Human Eye

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Clinical Update for Presbyopic Lens Options

Refractive Surgery: Vance Thompson, MD, FACS Refractive Surgeon. Oculeve Wavetec Zeiss Mynosys LRG Equinox Precision Lens ORA Amaken EXCELLens

OPTICAL SYSTEMS OBJECTIVES

Technicians & Nurses Program

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

ALADDIN. Optical Biometry and Topography System

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Roadmap to presbyopic success

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Digital Wide-field Imaging System

OCULUS Binoptometer 4P

Our vision is foresight

Optical Characteristics of Next Generation Dual Optic IOL

Cutting-edge image quality

THE ASPHERIC PRELOADED INJECTION

Essence. Newly designed, Huvitz continues to lead in product development combining innovation with value and performance HNT-1I 1P

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

FITTING GUIDE. Duette Hybrid Contact Lenses Duette Progressive Hybrid Contact Lenses - Center Distance - Center Near

Optical Coherence Tomography. RS-3000 Advance / Lite

you can See more with fundus autofluorescence. CR-2 PLUS NON-MYDRIATIC DIGITAL RETINAL CAMERA

Wearable Adaptive Refractor. Innovative, Electronic, Mobile and Wearable System of Adaptive Lenses.

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Optical aberrations and the eye Part 3

Fitting Manual Use with

DocuSign Envelope ID: 84A117BB E2D EEDC16E1FE5. ALADDIN Optical Biometry and Topography System

Long-term quality of vision is what every patient expects

Aberrations Before and After Implantation of an Aspheric IOL

Dr. Magda Rau Eye Clinic Cham, Germany

EXCHANGE. Financial Disclosure. Clinical pearls In advanced anterior segment surgery being able to do a IOL exchange is a must. Why Do an Exchange

COMPARISON OF THE MEDICONTUR 860FAB

INSTRUCTION MANUAL WAVE-FRONT ANALYZER. KR-1W Viewer. Version TOPCON Corporation

Quality Testing of Intraocular Lenses. OptiSpheric IOL Family and WaveMaster IOL 2

4/11/2016 DISCLOSURES DR. EIDEN (CONSULTING, LECTURER, RESEARCH, OR FINANCIAL INTEREST*)

Part 1: Ophthalmic optics Contact lenses. Vocabulary, classification system and recommendations for labelling specifications

KERATOCONUS. In the most advances cases, the corneal deformation can be easy observed fig. 1. Fig. 1

MULTIFOCAL CONTACT LENSES INTRODUCTION

Transcription:

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER EN

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER Combines placido disk topography with Sheimpflug tomography of the anterior segment. Sirius provides information on pachymetry, elevation, curvature and dioptric power of both corneal surfaces over a diameter of 12 mm. All biometric measurements of the anterior chamber are calculated using 25 sections from the cornea. Measurement speed reduces the effect of eye movement producing a high quality accurate measurement. In addition to the clinical diagnosis of the anterior segment the most common uses are: refractive and cataract surgery, an IOL calculation module is available. Objective examinations provide an accurate measurment of pupil diameter in scotopic, mesopic and photopic conditions. When combined with the corneal map they can be used for refractive surgery planning and follow up.

FEATURES OF THE PHOENIX SOFTWARE Sirius uses the Phoenix software platform allowing patient data to be saved for future review and analysis, shared by all CSO devices. GLAUCOMA SCREENING For glaucoma specialists Sirius enables the measurement of irido-corneal angles and pachymetry. These two values are useful in the diagnosis of the disease. INTRASTROMAL RINGS On the basis of the pachymetry map and corneal altimetric data, SIRIUS allows for intrastromal rings system planning, which maybe an option for the correction of refractive defects and some forms of keratoconus. KERATOCONOUS SCREENING Keratoconous screening provides the clinician with important information about the patinets cornea. Understanding this can help prevent complications associated with ectasia before corneal surgery is undertaken.

PUPILLOGRAPHY Sirius has built-in pupillography measurement soft ware. The measurement of the pupil in scotopic (0.04 lux), mesopic (4 lux), photopic (50 lux) conditions and in dynamic mode. Knowing the center and the diameter of the pupil, is essential for many clinical procedures which seek to optimize vision quality. CONTACT LENSES APPLICATION MODULE A contact lens fitting module is available which simulates the fit of rigid lenses based on an internal database of many lens manufacturers. CORNEAL ABERROMETRY IOL CALCULATION MODULE (OPTIONAL) This module is based on Ray-Tracing techniques, regardless of the state of the cornea (untreated or previously treated for refractive purposes), provides the calculation of the spherical and toric power of the intraocular lens. Aberrometric analysis offers a complete overview of the corneal aberrations. It is possible to select the contribution of the anterior, posterior or total cornea for different pupil diameters. The OPD/WFE maps and the visual simulations (PSF, MTF, image convolution with optotype) can help the clinician in understanding or explaining the patient s visual problems. MEIBOGRAPHY ADVANCED ANALYSIS OF THE TEAR FILM Placido disk technology allows for the advanced analysis of the tear film, such as NI-BUT (Non Invasive Break-up Time). Meibomian glands can be viewed under infrared light once the image is captured, you can use the soft ware to aid in the analysis of the condition of the glands.

Sirius TOMOGRAPH AND CORNEAL TOPOGRAPHER TECHNICAL DATA Data transfer Power supply Power net cable Dimensions (HxWxD) Weight Chin rest movement Minimum height of the chin cup from the table Base movement (xyz) Working distance: Firewire external power source 24 VCC In: 100-240Vac - 50/60Hz - 0.9-05A - Out: 24Vdc - 40W IEC C14 plug 515 x 315 x 255mm 7 Kg 70mm ± 1mm 24cm 105 x 110 x 30mm 74mm LIGHT SOURCES Placido disk Scheimpflug Pupilligraphy Led @635nm Led @475nm UV-free Led @875nm TOPOGRAPHY Placido rings 22 Measured points 21632 (front surface) 16000 (rear surface) Topographic covering 12mm Dioptric measurement range 1D to 100D Measurement accuracy Class A according to UNI EN ISO 19980-2012 Compatibility with standard DICOM v3 (IHE integration profile EYECARE Workflow) MINIMUM SYSTEM REQUIREMENT PC: 4 GB RAM - Video Card 1 GB RAM (not shared) resolution 1024 x 768 pixels - Firewire port. Operating system: Windows XP, Windows 7 and Windows 10 (32/64 bit). *The specifications and the images are not contractually binding and can be modified without notice. Windows is a Microsoft Corporation trade mark. CO130 Rev. 00 del 01/2018

YOUR PROFESSIONAL PARTNER SINCE 1967 Via degli Stagnacci 12/E 50018 - Scandicci - FI - Italy tel +39 055 72219 fax +39 055 7215557 email. cso@csoitalia.it web. www.csoitalia.it 0051