Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM

Similar documents
Constant Frequency / Lock-In (AM-AFM) Constant Excitation (FM-AFM) Constant Amplitude (FM-AFM)

Park NX-Hivac The world s most accurate and easy to use high vacuum AFM for failure analysis.

Basic methods in imaging of micro and nano structures with atomic force microscopy (AFM)

Outline: Introduction: What is SPM, history STM AFM Image treatment Advanced SPM techniques Applications in semiconductor research and industry

Akiyama-Probe (A-Probe) guide

Advanced Nanoscale Metrology with AFM

Nanoscale Material Characterization with Differential Interferometric Atomic Force Microscopy

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

Akiyama-Probe (A-Probe) guide

ATOMIC FORCE MICROSCOPY

Study of shear force as a distance regulation mechanism for scanning near-field optical microscopy

Part 2: Second order systems: cantilever response

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Electric polarization properties of single bacteria measured with electrostatic force microscopy

Phase Coherent Effect of UHV Dynamic Force Microscopy with Phase Locked. Oscillator

Suivie de résonance: méthodes à fréquences multiples. Romain Stomp Application Scientist, Zurich Instruments AG. ZI Applications

Akiyama-Probe (A-Probe) technical guide This technical guide presents: how to make a proper setup for operation of Akiyama-Probe.

Lateral Force: F L = k L * x

Nanosurf Nanite. Automated AFM for Industry & Research.

SENSOR+TEST Conference SENSOR 2009 Proceedings II

Atomic Force Microscopy (Bruker MultiMode Nanoscope IIIA)

Standard Operating Procedure of Atomic Force Microscope (Anasys afm+)

Scanning Tunneling Microscopy

easypll UHV Preamplifier Reference Manual

; A=4π(2m) 1/2 /h. exp (Fowler Nordheim Eq.) 2 const

Standard Operating Procedure

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

Figure for the aim4np Report

Prepare Sample 3.1. Place Sample in Stage. Replace Probe (optional) Align Laser 3.2. Probe Approach 3.3. Optimize Feedback 3.4. Scan Sample 3.

Cutting-edge Atomic Force Microscopy techniques for large and multiple samples

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

Experiment 7: Frequency Modulation and Phase Locked Loops

Keysight Technologies Using Non-Contact AFM to Image Liquid Topographies. Application Note

ABSTRACT. Gaurav Chawla, Doctor of Philosophy, Department of Mechanical Engineering

PACS Nos v, Fc, Yd, Fs

A Project Report Submitted to the Faculty of the Graduate School of the University of Minnesota By

RHK Technology. Application Note: Kelvin Probe Force Microscopy with the RHK R9. ω mod allows to fully nullify any contact potential difference

Lecture 20: Optical Tools for MEMS Imaging

Manufacturing Metrology Team

AFM Lab Aplication note P01. AD8429 Piezoresponse Force Microscopy Amplifier

Investigate in magnetic micro and nano structures by Magnetic Force Microscopy (MFM)

Distinguishing Between Mechanical and Electrostatic. Interaction in Single-Pass Multifrequency Electrostatic Force

CONSIDERATIONS FOR CRYOGENIC AFM OPERATION

Microscopic Structures

Phase modulation atomic force microscope with true atomic resolution

Imaging Carbon Nanotubes Magdalena Preciado López, David Zahora, Monica Plisch

SPM The Industry s Performance Leader High Resolution Closed-loop System Fast, Easy Tip & Sample Exchange Versatility and Value Powerful Research

High-speed wavefront control using MEMS micromirrors T. G. Bifano and J. B. Stewart, Boston University [ ] Introduction

High resolution measurements The differential approach

Elimination of bistability in constant-phase mode in atomic force microscopy

Optical Microscope. Active anti-vibration table. Mechanical Head. Computer and Software. Acoustic/Electrical Shield Enclosure

The Oscilloscope. Vision is the art of seeing things invisible. J. Swift ( ) OBJECTIVE To learn to operate a digital oscilloscope.

Long-distance propagation of short-wavelength spin waves. Liu et al.

Physics Faculty Publications and Presentations

Exam Signal Detection and Noise

3D Optical Motion Analysis of Micro Systems. Heinrich Steger, Polytec GmbH, Waldbronn

Multi-Probe Atomic Force Microscopy Using Piezo-Resistive Cantilevers and Interaction between Probes

VCXO Basics David Green & Anthony Scalpi

Noncontact atomic force microscopy simulator with phase-locked-loop controlled frequency detection and excitation

Near-field Optical Microscopy

MEMS. Platform. Solutions for Microsystems. Characterization

Scanning Microwave. Expanding Impedance Measurements to the Nanoscale: Coupling the Power of Scanning Probe Microscopy with the PNA

IE-35 & IE-45 RT-60 Manual October, RT 60 Manual. for the IE-35 & IE-45. Copyright 2007 Ivie Technologies Inc. Lehi, UT. Printed in U.S.A.

University of MN, Minnesota Nano Center Standard Operating Procedure

Electrical Properties of Chicken Herpes Virus Based on Impedance Analysis using Atomic Force Microscopy

PFM Experiments with High Voltage DC/AC Bias

UNIVERSITY OF WATERLOO Physics 360/460 Experiment #2 ATOMIC FORCE MICROSCOPY

Nanotechnology Solutions Partner

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

Description of options, upgrades and accessories for the laser beam stabilization system Compact

Akiyama-Probe (A-Probe) simple DIY controller This technical guide presents: simple and low-budget DIY controller

First and second order systems. Part 1: First order systems: RC low pass filter and Thermopile. Goals: Department of Physics

Instructions for easyscan Atomic Force Microscope

Atomic Force Microscopy (I)

LOW TEMPERATURE STM/AFM

DIGITAL COMMUNICATIONS (INTRODUCTION TO MULTISIM SOFTWARE)

Surface Finish Measurement Methods and Instrumentation

Experiment 1: Instrument Familiarization (8/28/06)

Glossary of VCO terms

Exercise 3 Operational Amplifiers and feedback circuits

Using Frequency Diversity to Improve Measurement Speed Roger Dygert MI Technologies, 1125 Satellite Blvd., Suite 100 Suwanee, GA 30024

MEMS Optical Scanner "ECO SCAN" Application Notes. Ver.0

Scanning force microscopy in the dynamic mode using microfabricated capacitive sensors

Experiment 1: Instrument Familiarization

Name Date: Course number: MAKE SURE TA & TI STAMPS EVERY PAGE BEFORE YOU START EXPERIMENT 10. Electronic Circuits

NanoFocus Inc. Next Generation Scanning Probe Technology. Tel : Fax:

Optimal Preamp for Tuning Fork signal detection Scanning Force Microscopy. Kristen Fellows and C.L. Jahncke St. Lawrence University

레이저의주파수안정화방법및그응용 박상언 ( 한국표준과학연구원, 길이시간센터 )

Physics 262. Lab #1: Lock-In Amplifier. John Yamrick

MEMS for RF, Micro Optics and Scanning Probe Nanotechnology Applications

Eddy current flaw detector «Eddycon C»

InstrumentationTools.com

Supporting Information

IMAGING P-N JUNCTIONS BY SCANNING NEAR-FIELD OPTICAL, ATOMIC FORCE AND ELECTRICAL CONTRAST MICROSCOPY. G. Tallarida Laboratorio MDM-INFM

Zero-Bias Resonant Sensor with an Oxide-Nitride Layer as Charge Trap

Manual CBT current preamplifier PA1 and CBT Reader software Version 1.5

Evaluation of Confocal Microscopy. for Measurement of the Roughness of Deuterium Ice. Ryan Menezes. Webster Schroeder High School.

Common-Source Amplifiers

SUPPLEMENTARY INFORMATION

Potential sensitivities in frequency modulation and heterodyne amplitude modulation Kelvin probe force microscopes

Transcription:

Park Atomic Force Microscopy Application note #21 www.parkafm.com Hosung Seo, Dan Goo and Gordon Jung, Park Systems Corporation Romain Stomp and James Wei Zurich Instruments Park NX-Hivac: Phase-lock Loop for Frequency Modulation Non-Contact AFM Phase-locked looping is a powerful technique that allows synchronization of multiple measurements such that several signals can be acquired at precisely the same moment in time. Combining the phase-locked loop (PLL) with an Atomic Force Microscope (AFM) enables capabilities such as frequency modulation (FM) AFM, which allows researchers to observe the dynamic properties of an oscillating cantilever which can be used to quantify surface potential measurements. This document reports the successful operation of a phase-locked loop (Zurich Instruments HF2PLL with Lock-in Amplifier [HF2LI]) with a Park Systems AFM [Park NX-Hivac]. The HF2PLL is an open market instrument supporting higher frequencies, multi-mode measurements, and advanced imaging modes such as amplitude modulation (AM) and FM for surface potential measurements. Moreover, the HF2PLL increases the power of Park Systems AFMs by enabling the operation of two cantilever modes simultaneously (performing measurements with 2PLLs) and demodulation of up to 6 arbitrary frequencies. To maximize the utility of a combined PLL-AFM, a high vacuum environment offers a high quality (Q) factor, which allows for increased adjustability of cantilever dynamics and Z height sensitivity. Taken together, the new Park NX-Hivac from Park Systems is an ideal system, offering an AFM environment with a base pressure well below 10-5 Torr with a Q factor three times greater than ambient situation. In this technical note, we will present the methodology for interfacing a Zurich Instruments PLL with a Park Systems controller using an Park NX-Hivac to control cantilever dynamics in Frequency Modulation Non-Contact AFM operation. INTRODUCTION Park Systems Park NX-Hivac allows failure analysis engineers to improve the sensitivity and resolution of their measurements in a high vacuum environment. High vacuum scanning offers improved accuracy, repeatability, and less tip and sample damage than ambient or dry N 2 conditions. The Park NX-Hivac is not only the world s most accurate high performance AFM, but it is also one of the easiest and most convenient AFMs to use for failure analysis applications. With Park NX-Hivac, you can increase your productivity and trust that your results are sound. Combining the Park Systems NX-Hivac (Fig. 1a) with the Zurich Instruments PLL (Fig. 1b) enables modes such as amplitude modulation and frequency modulation imaging. The Park NX-Hivac system features an evacuation chamber that houses an AFM. The chamber is connected to two vacuum pumps as shown in Fig. 1c. First the roughing valve opens to pump the system to 10-2 Torr. Higher vacuum is then achieved by activation of a turbo pump, increasing the vacuum to 10-5 Torr. Standard AFM cantilevers made from silicon or silicon nitride exhibit very high Q values in vacuum. This slow response time is advantageous for FM mode, which works well for high-q systems. In addition, by using a vacuum chamber, oxidation of the specimen can be prevented. 1

typically lead to an image artifact in constant height mode, but in feedback mode the feedback will read this as a stronger attractive force, causing positive feedback until the feedback saturates. An advantage of AM is that there is only one topography feedback compared to three in frequency modulation (the phase/frequency loop, the amplitude loop, and the topography loop), making both operation and implementation much easier. AM, however, is rarely used in vacuum as the Q of the sensor is usually so high that the sensor oscillates many times before the amplitude settles to its new value, thus slowing operation. Frequency modulation Figure 1 (a) Park NX-Hivac and (b) HF2PLL system (c) The vacuum pump system Frequency modulation (FM), introduced by Albrecht, Grütter, Horne An Overview of NC-AFM resonant frequency of the cantilever is tracked directly, by continu- NC-AFM technique guarantees constant transfer function response ally exciting the cantilever at resonance.2 The energy exchange is by tracking any change in phase or amplitude at the cantilever maximized if the driving signal has a 90 phase difference with resonance. This allows for quantitative measurements of respect to the oscillation of the cantilever. Therefore, to perform conservative interaction (induced by frequency shift change) and FM-AFM practically, the electronics must maintain this shift by dissipative interaction (energy put into the system to keep the either driving the sensor with the deflection signal phase shifted by amplitude constant). In contrast, intermittent-contact (IC) mode 90, or by using an advanced phase-locked loop which can lock to a operates in an open loop with direct lock-in amplifier measurements specific phase.3 The microscope can then use a reference channel to at a fixed frequency (near-resonance). The NC-AFM mode operates in a closed loop to ensure both the phase and the amplitude monitor the change in resonant frequency (Δf) operating in either feedback mode or constant height mode. While recording measurements are taken exactly at resonance. Any tip-sample frequency-modulated images, an additional feedback loop is interaction will induce a change in the free resonance frequency f0 typically used to keep the amplitude of resonance constant, by either toward positive shift in frequency f0 +Δf due to repulsive adjusting the drive amplitude. By recording the drive amplitude interactions, or negative shift f0 Δf due to attractive interactions. during the scan (usually referred to as the damping channel as the and Rugar in 1991, is a mode of NC-AFM where the change in need for a higher drive amplitude corresponds to more damping in Amplitude modulation the system), a complementary image is recorded showing only Amplitude modulation (AM) was one of the original modes of non-conservative forces. This allows conservative and operation introduced by Binnig and Quate in their seminal 1986 non-conservative forces in the experiment to be separated. This new AFM paper. In this mode, the sensor is excited at a frequency that resonance frequency f0 corresponds to the PLL output and to the is slightly offset from the resonance frequency. By exciting the new reference frequency for the lock-in measurements, illustrated in sensor just above its resonant frequency, it is possible to detect the upper feedback loop of the Fig. 2. This induced FM on the forces which change the resonant frequency by monitoring the cantilever resonance is also referred to as the FM-NC-AFM amplitude of oscillation. An attractive force on the probe causes a technique. Once the phase is locked, the same lock-in measure- decrease in the sensors resonant frequency, thus the driving ments provide the amplitude at the resonance and further establish frequency is further from resonance and the amplitude decreases. a closed-loop operation to maintain this set-point by adjusting the The opposite is true for a repulsive force. The AFM microscope s drive excitation, shown in the lower feedback loop of the Fig. 2. To control electronics can then use amplitude as a reference channel, either in feedback mode, or it can be recorded directly in constant benefit from steep slope sensitivity (i.e. high Q factor in vacuum), it is common practice to use a PLL based on the phase measurements height mode. AM can fail if the non-conservative forces change to capture the resonance frequency shift resulting from the during the experiment, as this changes the amplitude of the tip-sample interaction. In this manner, the resonator settling time is resonance peak itself, which will be interpreted as a change in no longer determined by the natural bandwidth of the resonator, resonant frequency. Another potential problem with AM is that a sudden change in sample-time interactions (increased repulsive namely f0/2q, but rather by the user-defined PLL bandwidth in a closed-loop operation. This is sometimes also referred to as the forces) can shift the cantilever resonant frequency past the drive constant amplitude mode. 1 frequency. This will ultimately cause an instability that would 2

Figure 2 Feedback loop where (a) FM and (b) AM techniques occur at the same time using HF2PLL system Figure 3 A representative frequency shift-distance curve. The forces reflect the Lennard-Jones potential for sample-tip interactions. Optimization of NC-AFM parameters Experimental The Lennard-Jones potential results from the contribution of short and long range forces, which is both non-linear and non-monotonic. The choice of frequency shift set-point (directly related to the interacting force) is therefore crucial and the best way to determine a set-point and Z-controller slope to perform a force (i.e. frequency shift)-vs-distance curve. Depending on the depth of the interaction well, three conditions, as shown in Fig. 3, can be set for repulsive, attractive, or minimum of the well (using differential measurements with height modulation). It is useful to note that in the repulsive regime, the dissipation channel can also be used as feedback for height. Dissipation has the advantage of exhibiting a monotonic decay with increasing tip-sample distance. 4 In addition, since electrostatic contribution is ubiquitous on most surfaces (from trapped charges, to different material composition and stray fields) it is also recommended that the experimenter evaluate if these forces are contributing to their signal by vary the tip-sample bias voltage once the PLL (on the phase) and PID (on the amplitude) are locked. Dissipation-vs-bias and frequency shift-vs-bias plots can be generated through a simple sweep, at constant height above the surface (i.e. Z-controller feedback off). The parabolic behavior of the electrostatic force can be displayed and its contact potential difference (CPD) determined from the maximum of the parabola. Electrostatic interactions can also be useful to ensure a smooth landing by generating an electrostatic cushion : a DC offset (away from CPD) generates a large electrostatic force thus producing long range interaction that the tip can probe while still being far away from the surface. In this technical note, we will show an example of how to generate the Δf-distance curve and the dissipation-bias curve, allowing for imaging. Measurement (Park NX-Hivac) Setup Example measurement The Park NX-Hivac AFM was used with a a cantilever that was 125 µm long and 4 µm thick with a nominal resonance frequency of 330kHz (free space) and a quality factor of 600. Typically, a 14 mv (peak-peak) drive amplitude led to the position sensitive photo detector (PSPD) signal of 450 mv in vacuum & free space (spring constant of 42nN/nm). The cantilever dynamics was detected by laser reflection onto a 4-quadrant photodiode (see Fig. 4). Figure 4 AFM diagram for NC-AFM. A cantilever is brought into frequency/amplitude feedback and modulated by a piezo modulation (MOD). The vertical and lateral cantilever movement is detected by a PSPD using laser reflection on the cantilever. Requirements To connect the HF2PLL with the Park NX-Hivac AFM, a Signal Access Module (SAM provided by Park Systems) and 5 BNC cables are required. Moreover, the reader should be familiar with the functionality of both the HF2PLL and the AFM. Both instruments are 3

controlled with their original operation software. The HF2PLL can be controller for recording and imaging. connected to an independent computer that runs the control software ziserver and zicontrol on either a Windows 7, Vista or Linux platform. The Park NX-Hivac AFM is operated from a Windows 7 based computer via the software SmartScan version RTM 8. The vacuum system is controlled by Hivac Manger, where pumping and venting processes are logically and visually controlled using one click. Each process is visually monitored by color and schematic changes, streamlining the vacuum operation. Faster and easier vacuum control software brings you ease of use AFM operation and better productivity. AFM data can be displayed and Figure 5 Setup BNC connections: Park NX-Hivac with the four inputs for recording and controlling of image data and the one output for input the PSPD signal to HF2PLL, HF2PLL with Signal Input 1, Signal Output 1, and the Auxiliary Outputs 1 to 3, SAM with the Vertical Output (PSPD A-B signal), the input for the piezo modulation and the change in frequency due to the interaction between the sample and tip. analyzed with Park system s standalone analysis software package XEI. Results and Discussion FM-NC-AFM Sample Characterization Initially a direct comparison of one of the lock-in amplifiers integrated in the NX-Hivac controller and the external HF2PLL can Δf-distance curve measurement (tip-sample distance) be achieved by connecting the following items: The samples measured here are highly oriented pyrolytic graphite The vertical deflection signal (connector labeled Monitoring A-B (HOPG) and silicon. First, care must be taken in the approach on the SAM) to the Signal Input 1 of the HF2PLL process in FM-NC-AFM due to sample-tip interactions. In vacuum, The HF2PLL Signal Output 1 to the drive piezo modulation input air damping is negligible, which makes it challenging to approach (connector Driving Piezo MOD on the SAM) The HF2PLL Auxiliary Outputs 1(Δf) to the feedback set-point the sample surface. To evaluate damping, a Δf-distance curve is performed (see Fig. 6). The air damping value depends on the tip input of the Z scanner (connector Driving A-B on the SAM) condition and increases when the tip is blunted or damaged. Also, The HF2PLL Auxiliary Outputs 2 and 3 (Aux 2/3) to the NX-Hivac in air in the imageable frequency, 43.7Hz in air and 8.6Hz in Controller back panel Aux 2 and 3 vacuum changes every 1 nm as the distance between tip and See Fig. 5 for a schematic of the connections between the PLL and AFM. The switches on the SAM can be set to External Controller specimen closes. to input an external signal into the system and breaking the internal signal line from the NX-Hivac controller. Definitions of Recorded and Displayed Quantities of the HF2PLL Vertical cantilever amplitude R: The amplitude reflects the information related to cantilever vibration. Phase Theta θ: The difference in phase between the cantilever drive frequency and actual cantilever oscillation. This parameter is to tip-sample-interactions (damping). Delta frequency Δf of PLL: By tracking the phase of the resonant frequency, Δf reflects the variation from the set frequency in air. In addition, the horizontal cantilever deflection can be detected in all modes of operation discussed here. By changing the switch position on the SAM to External Controller the cantilever driving piezo modulation is controlled by the HF2PLL and the Vertical PSPD Output (A-B) is applied to the Signal Input 1 for demodulation. The change in frequency due to the interaction between the sample and tip to the two signals connect to the set-point signal of the AFM feedback loop. The demodulated signals R and θ are routed via Auxiliary Outputs 2 and 3 to the analog inputs of the Park NX-Hivac Figure 6 Δf-distance curve in a narrow Z scanner height range (10nm) about (a) air and (b) vacuum condition. Δf-bias curve measurement For FM-NC-AFM, the approach process requires minimal noise due to the operation of the motor. To approach the sample in a gentle manner, air damping is used regardless of whether the system is in air or vacuum. In air, damping is significant however, in vacuum the air damping is minimal; therefore, forced air damping is employed by applying a tip bias. As shown in Fig. 7, we can confirm that air damping increases by applying a tip bias. When the Z scanner height is -0.5µm and the tip bias is varied from 0V, 2V to 4V, the Δf value are 0.81Hz, 1.01Hz and 1.72Hz, respectively. After stopping the Z stage using the value of the forced air damping interval, the approach can be completed by entering the area of interest for imaging with the Z scanner and low noise. The tip bias is used 4

because the sample bias is not affected by the tip when using an insulating sample. Figure 7 Δf-tip bias curve in vacuum. The Δf value begins at 0 Hz (graph is read right to left) and when the slope of the FM-NC-AFM amplitude increases sharply, the tip has approached the surface. As the tip bias is increased from 0 to 4 V, the approach is increasingly dampened and the sharp increase in Δf occurs further from the sample surface with increased voltage. FM-NC-AFM image in vacuum condition Fig. 8a-b show the topography and error signal for HOPG, respectively. It has a 10µm x 10µm image size and several layers are visible. Fig. 8c and Fig. 8d shows the topography and error signal for silicon, respectively. The image sizes are measured to be 0.2 µm and confirmed to have high resolution with a roughness RMS of 0.382 nm. This image is measured at a scan rate of 1 Hz and can be measured at a faster rate. Setting parameter value Resonance frequency: 306.516 khz Z-feedback set point: 10.83 Hz Amplitude swing: 4.5 nm Δf full range: +/- 20.83 Hz Cantilever stiffness: 35 N/m Figure 8 FM-NC-AFM image in vacuum condition. HOPG (a) topography and (b) error signal (Δf). White bar is 2 µm. Silicon (c) topography and (d) error signal (Δf). Blue bar is 40 nm. CONCLUSIONS FM-NC-AFM operation allows for quantitative tip-sample interaction measurements with high sensitivity from high Q factor in vacuum. It has been demonstrated to work seamlessly with the new Park NX-Hivac system from Park Systems, providing experimentalists with additional AFM modes to probe both mechanical and electrostatic interactions simultaneously, in a well-controlled environment. REFERENCES 1. Binnig, G.; Quate, C. F.; Gerber, C (1986). "Atomic Force Microscope". Physical Review Letters. 56 (9): 930 933 2. Albrecht, T. R.; Grütter, P.; Horne, D.; Rugar, D. (1991). "Frequency modulation detection using high-q cantilevers for enhanced force microscope sensitivity". Journal of Applied Physics, 69 (2): 668 3. Nony, Laurent; Baratoff, Alexis; Schär, Dominique; Pfeiffer, Oliver; Wetzel, Adrian; Meyer, Ernst (2006). "Noncontact atomic force microscopy simulator with phase-locked-loop controlled frequency detection and excitation". Physical Review B. 74 (23): 235439 4. A San Paulo, R García (2001). Tip-surface forces, amplitude, and energy dissipation in amplitude-modulation (tapping mode) force microscopy. Physical Review B, 2001 For more information, please visit: www.parkafm.com 3040 Olcott St. Santa, Clara CA 95054 inquiry@parkafm.com, +1 408-986-1110 5