DWDM SFP Series. Power budget* (note2) Laser

Similar documents
DWDM SFP Series. Laser

DWDM SFP Series. Power budget* (note2) Laser

DWDM SFP Series. Power budget* (note2) Laser

DWDM SFP Series. DIxx-SFP-LC.S120. Features. Applications. Ordering Information

DWDM SFP Series. Laser

SFP Series. EOLS-1348-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm FC/2FC/4FC Duplex SFP Transceiver RoHS6 Compliant

DWDM SFP+ Series DWDM EML

SFP Series. EOLS X Series. Features. Applications. Ordering Information

SFP Series EOLS X. Features. Applications. Ordering Information

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

DWDM SFP+ Series DWDM EML DWDM EML

SFP Series. Distance * (note2) Interface Temp. DDMI

SFP+ Series EOLP Features. Applications. Ordering information

BIDI SFP Series. Part No. Data Rate Wavelength Interface Temp. DDMI

SFP+ Series EOLP M-I. Features. Applications. Ordering information

DWDM SFP+ Series. EOLP XXXN series. Features. Applications. Ordering Information

SFP+ BIDI Series JB1270-SFP-LC.S40. Features. Applications. Ordering information

CWDM EML. SMF 23dB YES LC. note1: X refers to CWDM Wavelength range 1470nm to 1610nm, X=K~R, denotes 1470~1610nm.

DWDM SFP+ Series. EOLP XXXN MSA Series. Features. Applications. Ordering Information

SFP28 Series Preliminary EOLP-8525G-02-R. Features. Applications. Ordering information

SFP Module DB1310-SFP-SC.S20 DB1550-SFP-SC.S20. Features. Applications. Ordering information

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note1) Interface Temp. DDMI.

SFP Series. EOLS-BI Series EOLS-BI Series. Features. Applications. Ordering information

Regulatory Compliance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge to the enclosure Electromagnetic Interference (EMI)

SFP Series EOLS-BI Series EOLS-BI Series

1/12. SFP модули. Модели SFP-DWDM-GE-15xx.xx-28. Особенности: - 100Mbps Gbps - встроенная функция диагностики (DDMI)

1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

EOLS-1312-XXXX 1.25Gbps SFP Transceiver

Fiber Distance* (note2) Temp. Connector DDM

SFF Series EOLF Series EOLF Series

DWDM SFP+ Series EOLP XXN MSA Series

850nm SFP28 Multi-Mode Transceiver, With Diagnostic Monitoring and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type.

SFF Series EOLF Series

Part No. Data Rate Wavelength Interface Temp. DDMI /1.25Gbps 1310nm SC Industrial NO EOLS-BI I

SFP+ Tunable Preliminary. EOLP-1696-TDW-23XXXN MSA Series. Features. Applications. Ordering Information

SFP+ Series EOLP XN MSA Series

SFP Series. EOLS-1312-X Series. Features. Applications. Ordering Information. Single-Mode 1310nm 1.25Gbps FC/GBE Duplex SFP Transceiver RoHS Compliant

Fiber Channel Links Standard: 0 ~+70 Industrial: -40 ~+85 Compliant with GBIC Specification Rev. 5.5

SFP+ BIDI Series EOLP-BI1696-9ADL & EOLP-BI1696-9DAL Series

4.25Gbps SFP Transceiver

DWDM SFP+ single-mode Transceiver, With Diagnostic Monitoring Multi-rate 16x / 8x / 4x Fibre Channel Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP+ BIDI Series GigaStream BIDI-10G-SFP-40A & BIDI-10G-SFP-40B

SFP Series. Fiber Distance* (note2) Interface Temp. DDMI

SFP Series. EOLS X Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1xFC /GBE Duplex SFP Transceiver RoHS6 Compliant

2.5Gbps SFP Transceiver

DWDM MultiRate SFP Series

SFP Series IOLS-1348-XXXX. 4.25Gbps up to 30 km transmission. version 0.1 FEATURES PRODUCT DESCRIPTION

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-EW/ER Duplex SFP+ Transceiver, RoHS 6 Compliant. Fiber Type.

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP Series. Single-Mode 1310nm for GE, STM1/STM4/STM16, FC/2XFC Duplex SFP Transceiver RoHS6 Compliant. Distance * (note2) Interface Temp. DDMI.

10G PON Series Preliminary

SFP Series IOLS-1624-XX-XX. 2.5Gbps APD High Sensitivity Receiver. version 0.1 FEATURES PRODUCT DESCRIPTION

Fiber Distance* (note2) Interface Temperature DDMI Rate

SFP+-DWDM-xx-80D. 10Gbps DWDM SFP+ Optical Transceiver, 80km Reach

SFP+ Series. 1550nm SFP+ single-mode Transceiver, With Diagnostic Monitoring Duplex SFP+ Transceiver RoHS 6 Compliant

SFP+ BIDI Series JB1270-SFP-LC.S20

SFP-CWDMxx.60. CWDM* Wavelength (0 to 70 o C)

SFP+ Cable Assemblies, 0.5m/1m/2m/3m/4m/5m/6m/7m/8m/9m/10m/11m/12m/15m Reach RoHS6 Compliant. Lengt

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

SFP28 Series Preliminary EOLP-1325G-10-RX. Features. Applications. Ordering information

SFF Series. EOLF Series. Features. Applications. Ordering Information. Multi-Mode 850nm 1250Mbps Duplex SFF Transceiver RoHS6 Compliant

SFP Series. EOLS-BI CL XX Series EOLS-BI LC XX Series. Features. Applications. Ordering Information

1310nm SFP28 Single-Mode Transceiver, With DDM and Dual CDR Duplex SFP28 Transceiver, RoHS 6 Compliant. Fiber Type Gbps 1310nm and DFB 28.

SNR-SFP-LX 1.25Gbps. Features. Applications. Product Description

SFP+ Series SFP-10G-SR

PON Series. EOLS-GN- 25-XX Series. Features. Applications. Ordering Information. Link Budget. Input/ Output. DDMI Interface Temp. Part No.

SFP+-CWDM-xx-40D. 10Gbps CWDM SFP+ Optical Transceiver, 40km Reach

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gbps CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

DWDM SFP+ Transceiver With Digital Diagnostic Function

XFP CWDM BIDI Series Preliminary

Part No. Input Output Burst-mode Fiber Interface Temp.

XFP Series EOLX X. Features. Applications. Ordering Information. CWDM XFP Single-Mode for 10GbE/10GFC Duplex XFP Transceiver RoHS6 Compliant

GPON ONU Series. EOLF-GU5-25-P Series. Features. Applications. Ordering Information. Case Temperature. Part No. Input Output Burst-mode Interface

Part No. Data Rate Fiber Distance Interface Temperature DDMI

SO-CSFP-100Base-BX20D-34-O2 -I

OCTECH 1.25Gbps SFP Transceiver

QSFP+ Series Preliminary EOLQ-8540G-03-MO Series

OCTECH 1.25Gbps SFP Transceiver

XFP Series. JCxxxx-XFP-LC.S40. Features. Applications. Ordering Information

Part No. Data Rate Fiber Distance Interface Temperature

XFP BIDI Series EOLX-BI1696-9ADL & EOLX-BI1696-9DAL

XFP Series EOLX XX Series

SFP+-10GB-ZR. 10Gbps SFP+ Optical Transceiver, 80km Reach

GLC-GE-100FX-LEG. 155Mbps SFP Transceiver

SNR-SFP+W73-20 SNR-SFP+W db Power Budget BIDI SFP+ 10GbE Transceiver

SO-SFP-1000BASE-ZXD-I

Regulatory Compliance Feature Standard Performance Electrostatic Discharge (ESD) to the Electrical Pins Electrostatic Discharge To the enclosure Elect

XFP Series. JCxxxx-XFP-LC.S80. Features. Applications. Ordering Information

10GBASE-PR-D3 application CML interface logic level for Gbps data. Part No. Input Output Fiber Interface Temperature AC/10G DC/1G

GBIC Series. EOLG-1612-X-X Series. Features. Applications. Ordering information

SFP Series. Features. Applications. Ordering information. Single-Mode 155Mbps SC Single-Fiber SFP Transceiver RoHS6 Compliant

GBIC BIDI Series. EOLG-BI1X12-2M series. Features. Applications. Ordering information

1.25Gbps SFP Transceiver

850nm SFP+ Multi-Mode Transceiver, With Diagnostic Monitoring 10G BASE-SW/SR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

Note1: Standard version, the distance is measured under Lab condition. For other ordering information in detail, please contact EOPTOLINK..

1310nm SFP+ single-mode Transceiver, With Diagnostic Monitoring 10G BASE-LW/LR 0.6~10Gb/s CPRI/OBSAI Duplex SFP+ Transceiver, RoHS 6 Compliant

GPON ONU Series. EOLF-GUA-25 Series. Features. Applications. Ordering Information. Input/ Output. Part No. Burst-mode DDMI Interface Case Temp.

DATASHEET 4.1. SFP, 100Mbps-2.7Gbps, Multirate, 1310nm, SM, DDM, 8dB, 2km, ind.temp.

Transcription:

EOLS-1648-XXD Series SFP Single-Mode for DWDM Application Duplex SFP Transceiver Digital Diagnostic Function RoHS6 Compliant Features Operating Data Rate up to 4.25Gbps Available in all C-Band Wavelengths on the 100GHz DWDM ITU Grid Single 3.3V Power Supply and TTL Logic Interface Hot-Pluggable SFP Footprint Duplex LC Connector Interface Compliant with Class 1 FDA and IEC60825-1 Laser Safety Compliant with SFP MSA Compliant with SFF-8472 Operating Case Temperature: Standard: 0 to 70 C Extended: -5 to 70 C Applications Amplified DWDM networks Ring topologies with fixed and reconfigurable OADMs Fast Ethernet, Giga Ethernet Fiber Channel SONET / SDH Switch Ordering Information Part No. Data Rate Laser Power budget* (note2) Interface Temperature EOLS-1648-18XX *(note1) D 4.25GMbps DWDM DFB 18dB LC Standard EOLS-1648-18XX *(note1) DI 4.25GMbps DWDM DFB 18dB LC Extended EOLS-1648-24XX *(note1) D 4.25GMbps DWDM DFB 24dB LC Standard EOLS-1648-24XX *(note1) DI 4.25GMbps DWDM DFB 24dB LC Extended Note1: XX refers to DWDM Wavelength range as ITU-T specified, please refer the following table for detailed center wavelength information. Note2: The power budget which is guaranteed. Page 1 of 13

XX- Channel refers to the following table: Channel (XX) Part NO. Frequency (THz) Center Wavelength (nm) 15 EOLS-1648- X15D EOLS-1648- X15DI 191.5 1565.50 16 EOLS-1648- X * 16D EOLS-1648- X * 16DI 191.6 1564.68 17 EOLS-1648- X * 17D EOLS-1648- X * 17DI 191.7 1563.86 18 EOLS-1648- X * 18D EOLS-1648- X * 18DI 191.8 1563.05 19 EOLS-1648- X * 19D EOLS-1648- X * 19DI 191.9 1562.23 20 EOLS-1648- X * 20D EOLS-1648- X * 20DI 192.0 1561.42 21 EOLS-1648- X * 21D EOLS-1648- X * 21DI 192.1 1560.61 22 EOLS-1648- X * 22D EOLS-1648- X * 22DI 192.2 1559.79 23 EOLS-1648- X * 23D EOLS-1648- X * 23DI 192.3 1558.98 24 EOLS-1648- X * 24D EOLS-1648- X * 24DI 192.4 1558.17 25 EOLS-1648- X * 25D EOLS-1648- X * 25DI 192.5 1557.36 26 EOLS-1648- X * 26D EOLS-1648- X * 26DI 192.6 1556.55 27 EOLS-1648- X * 27D EOLS-1648- X * 27DI 192.7 1555.75 28 EOLS-1648- X * 28D EOLS-1648- X * 28DI 192.8 1554.94 29 EOLS-1648- X * 29D EOLS-1648- X * 29DI 192.9 1554.13 30 EOLS-1648- X * 30D EOLS-1648- X * 30DI 193.0 1553.33 31 EOLS-1648- X * 31D EOLS-1648- X * 31DI 193.1 1552.52 32 EOLS-1648- X * 32D EOLS-1648- X * 32DI 193.2 1551.72 33 EOLS-1648- X * 33D EOLS-1648- X * 33DI 193.3 1550.92 34 EOLS-1648- X * 34D EOLS-1648- X * 34DI 193.4 1550.12 Page 2 of 13

35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 EOLS-1648- X * 35D EOLS-1648- X * 35DI 193.5 1549.32 EOLS-1648- X * 36D EOLS-1648- X * 36DI 193.6 1548.51 EOLS-1648- X * 37D EOLS-1648- X * 37DI 193.7 1547.72 EOLS-1648- X * 38D EOLS-1648- X * 38DI 193.8 1546.92 EOLS-1648- X * 39D EOLS-1648- X * 39DI 193.9 1546.12 EOLS-1648- X * 40D EOLS-1648- X * 40DI 194.0 1545.32 EOLS-1648- X * 41D EOLS-1648- X * 41DI 194.1 1544.53 EOLS-1648- X * 42D EOLS-1648- X * 42DI 194.2 1543.73 EOLS-1648- X * 43D EOLS-1648- X * 43DI 194.3 1542.94 EOLS-1648- X * 44D EOLS-1648- X * 44DI 194.4 1542.14 EOLS-1648- X * 45D EOLS-1648- X * 45DI 194.5 1541.35 EOLS-1648- X * 46D EOLS-1648- X * 46DI 194.6 1540.56 EOLS-1648- X * 47D EOLS-1648- X * 47DI 194.7 1539.77 EOLS-1648- X * 48D EOLS-1648- X * 48DI 194.8 1538.98 EOLS-1648- X * 49D EOLS-1648- X * 49DI 194.9 1538.19 EOLS-1648- X * 50D EOLS-1648- X * 50DI 195.0 1537.40 EOLS-1648- X * 51D EOLS-1648- X * 51DI 195.1 1536.61 EOLS-1648- X * 52D EOLS-1648- X * 52DI 195.2 1535.82 EOLS-1648- X * 53D EOLS-1648- X * 53DI 195.3 1535.04 EOLS-1648- X * 54D EOLS-1648- X * 54DI 195.4 1534.25 EOLS-1648- X * 55D EOLS-1648- X * 195.5 1533.47 55DI 56 EOLS-1648- X * 56D 195.6 1532.68 Page 3 of 13

EOLS-1648- X * 56DI 57 EOLS-1648- X * 57D EOLS-1648- X * 57DI 195.7 1531.90 58 EOLS-1648- X * 58D EOLS-1648- X * 58DI 195.8 1531.12 59 EOLS-1648- X * 59D EOLS-1648- X * 59DI 195.9 1530.33 60 EOLS-1648- X * 60D EOLS-1648- X * 60DI 196.0 1529.55 61 EOLS-1648- X * 61D EOLS-1648- X * 61DI 196.1 1528.77 *: X refers to the DWDM Power budget(18 24). please contact EOPTOLINK to confirm whether the wavelength is available. Regulatory Compliance* Note3 Product Certificate Certificate Number Applicable Standard TUV R50135086 EN 60950-1:2006+A11+A1+A12 EN 60825-1:2007 EN 60825-2:2004+A1+A2 UL E317337 UL 60950-1 CSA C22.2 No. 60950-1-07 EMC CE AE 50285865 0001 EN 55022:2010 EN 55024:2010 CB JPTUV-049251 IEC 60825-1 IEC 60950-1 FCC WTF14F0514437E 47 CFR PART 15 OCT., 2013 FDA 1331340-000 CDRH 1040.10 ROHS RHS01G006464 2011/65/EU Note3: The above certificate number updated to June 2014, because some certificate will be updated every year, such as FCC, FDA and ROHS. For the latest certification information, please check with Eoptolink. Product Description The EOLS-1648-XXD series single mode transceiver is small form factor pluggable module for duplex optical data communications. This module is designed for single mode fiber and operates at a nominal DWDM wavelength from 1528.77nm to 1565.50nm as specified by the ITU-T. It is designed to deploy in the DWDM networking equipment in metropolitan access and core networks. It is with the SFP 20-pin connector to allow hot plug capability. The transmitter section uses a DWDM multiple quantum well DFB laser and is a class 1 laser compliant according to International Safety Standard IEC-60825. The EOLS-1648-XXD series are designed to be compliant with SFF-8472 Multi-Source Agreement (MSA). Page 4 of 13

Absolute Maximum Ratings Parameter Symbol Min. Max. Unit Storage Temperature T S -40 +85 C Supply Voltage V CC -0.5 3.6 V Operating Relative Humidity - 95 % *Exceeding any one of these values may destroy the device permanently. Recommended Operating Conditions Parameter Symbol Min. Typical Max. Unit Operating Case Temperature T c EOLS-1648-XXD 0 - +70 EOLS-1648-XXDI -5 - +70 Power Supply Voltage Vcc 3.15 3.3 3.45 V Power Supply Current Icc - - 455 ma Date Rate 4.25G bps Performance Specifications - Electrical Parameter Symbol Min. Typ. Max Unit Notes Transmitter CML AC coupled Vin 400 2000 mvpp Inputs(Differential) inputs* (note4) Input Impedance (Differential) TX_Dis Zin 85 100 115 ohm Disable 2 Vcc Enable 0 0.8 TX_FAULT Fault 2 Vcc Normal 0 0.8 V Receiver CML Outputs (Differential) Vout 400 800 1200 mvpp Output Impedance (Differential) RX_LOS MOD_DEF ( 0:2 ) Zout 85 100 115 ohm LOS 2 Vcc V Normal 0 0.8 V VoH 2.5 V VoL 0 0.8 V V C Rin > 100 kohm @ DC AC coupled outputs Page 5 of 13

Performance Specifications Optical (DWDM DFB and PIN/TIA, 18dB Power Budget at Least) Parameter Symbol Min. Typical Max. Unit Data Rate 4.25 bps Transmitter Center Wavelength Spacing 100 GHz 0.8 nm Spectral Width (-20dB) Δλ 0.3 nm Deviation From Central Frequency@EOL -12 12 GHz Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note5) Pout 0 5 dbm Extinction Ratio@4.25Gb/s ER 4.5 db Average Launch Power (Tx: OFF) Poff -45 dbm Rise/Fall Time(Unfiltered,20%~80%) tr/tf 120 ps Output Optical Eye* (note6) Complies with ANSI FC-PI specification* (note8) TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -135 db/hz Dispersion Tolerance DT 800 ps/nm Receiver Center Wavelength λ 1528 1665 nm Receiver Sensitivity* (note7) Pmin -18 dbm Receiver Overload Pmax -3 dbm LOS De-Assert LOSD -19 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note9) 0.5 db (DWDM DFB and APD, 24dB Power Budget at Least) Parameter Symbol Min. Typical Max. Unit Data Rate 4.25G bps Transmitter Center Wavelength Spacing 100 GHz 0.8 nm Spectral Width (-20dB) Δλ 0.3 nm Deviation From Central Frequency@EOL -12 12 GHz Side Mode Suppression Ratio SMSR 30 db Average Output Power* (note5) Pout 0 5 dbm Average Launch Power (Tx: OFF) Poff -45 dbm Extinction Ratio@4.25Gb/s ER 4.5 db Rise/Fall Time(Unfiltered,20%~80%) tr/tf 120 ps Output Optical Eye* (note6) Complies with ANSI FC-PI specification* (note8) Page 6 of 13

TX_Disable Assert Time t_off 10 us Pout@TX Disable Asserted Pout -45 dbm Relative Intensity Noise RIN -135 db/hz Dispersion Tolerance DT 1600 ps/nm Receiver Center Wavelength λ 1528 1665 nm Receiver Sensitivity* (note7) Pmin -24 dbm Receiver Overload Pmax -9 dbm LOS De-Assert LOSD -25 dbm LOS Assert LOSA -35 dbm LOS Hysteresis* (note9) 0.5 db Note4: CML logic, internally AC coupled. Note5: Output power is power coupled into a 9/125μm single-mode fiber. Note6: Filtered, measured with a PRBS 2 7-1 test pattern @4.25Gbps Note7: Minimum average optical power at BER less than 1E-12 or lower, with a 2 7-1 NRZ PRBS. Note8: Eye Pattern Mask Note9: LOS Hysteresis Functional Description of Transceiver Page 7 of 13

SFP Transceiver Electrical Pad Layout Pin Function Definitions Pin Num. Name Function Description 1 VeeT Transmitter Ground 2 TX Fault Transmitter Fault Indication, open collector/drain output 3 TX Disable Transmitter Disable 4 MOD-DEF2 Module Definition 2, Data line for Serial ID. 5 MOD-DEF1 Module Definition 1, Clock line for Serial ID. 6 MOD-DEF0 Module Definition 0, Grounded within the module. 7 Rate Select Not Connect, Function not available 8 LOS Loss of Signal, open collector/drain output 9 VeeR Receiver Ground 10 VeeR Receiver Ground 11 VeeR Receiver Ground 12 RD- Inv. Received Data Out 13 RD+ Received Data Out 14 VeeR Receiver Ground Page 8 of 13

15 VccR Receiver Power, 3.3 ± 5% 16 VccT Transmitter Power, 3.3 ± 5% 17 VeeT Transmitter Ground 18 TD+ Transmit Data In 19 TD- Inv. Transmit Data In 20 VeeT Transmitter Ground EEPROM The serial interface uses the 2-wire serial CMOS EEPROM protocol defined for the ATMEL AT24C02/04 family of components. When the serial protocol is activated, the host generates the serial clock signal (SCL). The positive edge clocks data into those segments of the EEPROM that are not write protected within the SFP transceiver. The negative edge clocks data from the SFP transceiver. The serial data signal (SDA) is bi-directional for serial data transfer. The host uses SDA in conjunction with SCL to mark the start and end of serial protocol activation. The memories are organized as a series of 8-bit data words that can be addressed individually or sequentially. The Module provides diagnostic information about the present operating conditions. The transceiver generates this diagnostic data by digitization of internal analog signals. Calibration and alarm/warning threshold data is written during device manufacture. Received power monitoring, transmitted power monitoring, bias current monitoring, supply voltage monitoring and temperature monitoring all are implemented. If the module is defined as external calibrated, the diagnostic data are raw A/D values and must be converted to real world units using calibration constants stored in EEPROM locations 56 95 at wire serial bus address A2H. The digital diagnostic memory map specific data field define as following.for detail EEPROM information, please refer to the related document of SFF 8472 Rev 9.3. Page 9 of 13

EEPROM Serial ID Memory Contents Accessing Serial ID Memory uses the 2 wire address 1010000X(A0H). Memory Contents of Serial ID are shown in Table 1. Addr. Size (bytes) Table 1 Serial ID Memory Contents Name of field Vaule(Hex) Description 0 1 Identifier 0B DWDM SFP 1 1 Ext. Identifier XX 2 1 Connector 07 LC connector 3-10 8 Transceiver Codes 00 Reserved 00-00 - XX XX XX 01 Single mode XX 11 1 Encoding XX 12 1 BR, Nominal XX (note10) 13 1 Reserved 00-14 1 Length (9µm)km XX 15 1 Length(9µm)100m FF 16 1 Length (50µm) 10m 00 17 1 Length(62.5µm)10m 00 18 1 Length (Copper) 00 Not compliant 19 1 Reserved 00 20~35 16 Vendor Name 36 1 Implemented Optional DWDM Features XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX (note11) 00-37-39 3 Vendor OUI 00 00 00-40-55 16 Vendor PN 56-59 4 Vendor Rev XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX XX (note11) XX XX XX XX (note11) PN Vendor name 60-62 3 Wavelength XX Laser Wavelength Page 10 of 13

63 1 CC-BASE XX CC for Base ID fields implemented (addresses 0 to62) 00 Reserved 1.TX_DISABLE is implemented 64~65 2 Options and disables the serial output; 1A 2.TX_FAULT signal implemented; 3.Loss of Signal implemented 66 1 BR, max 00-67 1 BR, max 00-68~83 16 Vendor SN XX Serial number of Transceiver (ASCII) 84~89 6 Date code XX The vendor s date code (ASCII) 90~91 2 Vendor specific lot code XX XX - 1. Digital diagnostic monitoring implemented 92 1 2.Internally/Externally Diagnostic XX Calibrated; Monitoring Type 3.Received power measurement type is Average Power 1.Optional Alarm/warning flags implemented for all monitored quantities 2. Optional Soft TX_DISABLE 93 1 Enhanced Options F0 control and monitoring implemented 3. Optional Soft TX_FAULT monitoring Implemented 4. Optional Soft RX_LOS monitoring Implemented 94 1 SFF-8472 Includes functionality described 01 Compliance in Rev 9.3 of SFF-8472. CC for the extended ID Fields 95 1 CC_EXT XX (addresses 64 to 94) implemented. 96~127 32 Vendor Specific XX Read only memory 128-255 128 Reserved Read only Note10: The XX byte should be filled in according to practical case. For more information, please refer to the related document of SFP Multi-Source Agreement (MSA). Page 11 of 13

Recommend Circuit Schematic Mechanical Specifications Page 12 of 13

Obtaining Document You can visit our website:http://www.eoptolink.com Or contact Listed at the end of the documentation to get the latest documents. Revision History Release Revision Initiated Reviewed Approved Revision History Date V2.a Tim.Liang Kelly.Cao Released. Oct 24, 2009 V2.b Kelly Revise the A2H. Nov 24, 2009 V2.c Kelly Page 13 of 13 Complete the DWDM wavelength. Jan 18, 2010 V2.d Kelly Correct Rx λ range. Apr 8, 2010 V3.a Kelly Update PN&LOGO. July 19, 2011 V3.b Jans Kelly V3.C Jans Kelly V3.d V3.e Jans Jans/ Angela Lyn,Jason, Walt Nigai/Lyn/ Jason/Walt Angela Kelly/Vina Notice: Phlio Phlio Update EEPROM map, integrate 3 products. Update Extinction Ratio. Update the applications. Update the MAX Budget from 26dB to 24dB. Add Dispersion Tolerance Update the regulatory compliance,losa and 2D drawing. Sep 21, 2011 Oct 27,2012 June 4, 2013 August 14, 2013 Oct 28,2015 Eoptolink reserves the right to make changes to or discontinue any optical link product or service identified in this publication, without notice, in order to improve design and/or performance. Applications that are described herein for any of the optical link products are for illustrative purposes only. Eoptolink makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Contact: Add: Floor 5, Building 2, No. 21 Gaopeng Avenue, High-Tech District, CHENGDU, SICHUAN 610041 P.R. CHINA Tel: (+86) 028-85122709 ext 816 & 809 Fax: (+86) 028-85121912 Postal: 610041 E-mail:sales@eoptolink.com http://www.eoptolink.com