RF Explorer. User Manual. RF Explorer User Manual v Page 1 of 13. Updated to firmware v1.05. Edition date: 2011/Mar/01.

Similar documents
RF Explorer. User Manual. Signal Generator. Updated to Firmware Version 1.12 BETA

RF Explorer. User Manual. Signal Generator. Updated to Firmware Version

RF Explorer. User Manual. Updated to Firmware Version 1.26 for Standard models. Updated to Firmware Version 3.06 for Plus models

RF Explorer. User Manual. Updated to Firmware Version 1.17

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

AN4949 Application note

Demo / Application Guide for DSA815(-TG) / DSA1000 Series

Instruction Manual for the Software of ASSAN V2 Series Receiver

DSA-815 Demo Guide. Solution: The DSA 800 series of spectrum analyzers are packed with features.

Agilent CSA Spectrum Analyzer

Signal Generators for Anritsu RF and Microwave Handheld Instruments

Spectrum Analyzer R&S FS300

EXHIBIT 7: MEASUREMENT PROCEDURES Pursuant 47 CFR 2.947

Antenna and Propagation

Rigol DSA705 Spectrum Analyzer Reviewed by Phil Salas AD5X

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

TEST EQUIPMENT PLUS. Signal Hound USB-SA44B / USB-TG44A. Application Note 1: The Smith Chart. Rev. 0

P a g e 1 ST985. TDR Cable Analyzer Instruction Manual. Analog Arts Inc.

WE-2705P Antenna Analyzer

Faculty of Electrical & Electronics Engineering BEE4233 Antenna and Propagation. LAB 1: Introduction to Antenna Measurement

Spectrum Analyzers 2680 Series Features & benefits

Title: Test on 5.8 GHz Band Outdoor WiFi (802.11b/g) Wireless Base Station

Agilent ESA-L Series Spectrum Analyzers

AN5009 Application note

Willtek. Handheld Spectrum Analyzer

6.2GHz SPECTRUM ANALYZER

External Source Control

AN4378 Application note

7. Transmitter Radiated Spurious Emissions and Conducted Spurious Emission

AN4392 Application note

Basic Transceiver tests with the 8800S

APPLICATION NOTE Getting Started with EasySpectrum Software

AN5029 Application note

FCC Test Report - LTE Band 26 (part 22)

DMR Application Note Testing MOTOTRBO Radios On the R8000 Communications System Analyzer

Siglent Technologies SSA3021X Spectrum Analyzer and TG-SSA3000X Tracking Generator Reviewed by Phil Salas AD5X

IQ+ XT. 144Mhz SDR-RF Exciter (preliminar v0.1)

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.10.x

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Application Note: DMR Application Note Testing MOTOTRBO Radios On the Freedom Communications System Analyzer

2801 Multilock. Communications System Analyzer. Data Sheet. Boosting wireless efficiency

Review: The MFJ-225 Graphical Antenna Analyzer Phil Salas AD5X

USER MANUAL. CommRadio CR-1 Communications Receiver

Multifunctional Microwave Analyzer

WTX-610 Illuminator 6 GHz Multi-Mode Test Transmitter User Manual

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

S5101 Handheld Radio Communication Analyzer

Suitable firmware can be found on Anritsu's web site under the instrument library listings.

JD723A/JD724B/JD726A Cable and Antenna Analyzers

DragonLink Advanced Transmitter

Preliminary RFI Survey for IIP

Page 1 of 51 Report No.: T TEST REPORT FCC ID: 2AGJ5WAP-30. In Accordance with: FCC PART 15, SUBPART C : 2015 (Section 15.

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

IT-24 RigExpert. 2.4 GHz ISM Band Universal Tester. User s manual

AV3672 Series Vector Network Analyzer

Quick Start Guide for the PULSE PROFILING APPLICATION

JD746A/JD786A CellAdvisor RF Analyzer

Advanced Test Equipment Rentals ATEC (2832)

AirScope Spectrum Analyzer User s Manual

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.9.2

Application Note TS-EMF. System for RF Exposure Measurements. System Check with Tri-Axis Sensor (Isotropic Antenna)

FCC 47 CFR PART 15 SUBPART C INDUSTRY CANADA RSS-210 ISSUE 8 BLUETOOTH LOW ENERGY CERTIFICATION TEST REPORT FOR. 2.4GHz LE MODULE MODEL NUMBER: RN4020

DSA700 Series Spectrum Analyzer

USER OPERATION AND MAINTENANCE MANUAL

Transcom Instruments. Product Brochure TRANSCOM INSTRUMENTS. Product Brochure

Revision history. Revision Date of issue Test report No. Description KES-RF-14T0042 Initial

FCC CFR47 PART 15 SUBPART C INDUSTRY CANADA RSS-GEN AND RSS-210 CERTIFICATION TEST REPORT FOR BROADCOM BLUETOOTH MODULE MODEL NUMBER: BCM92046MD

Handheld 3.3GHz Spectrum Analyzer

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version 0.9.2

Agilent CSA Spectrum Analyzer

OPEN TEM CELLS FOR EMC PRE-COMPLIANCE TESTING

Dynamic Sciences International, Inc. Detection with Direction

FCC Test Report - UMTS Band 4

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider

Quick Start Guide V1.1

Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

CAA-100A Cable & Antenna Analyzer + Spectrum Analyzer

Quanum RC-216R FPV receiver

Xeta4. Occupied Bandwidth. Measurements

ER55 EMI TEST RECEIVER Family of automatic test receivers for measurement of electromagnetic interference from 9kHz to 1GHz

Application Note: Swept Return Loss & VSWR Antenna Measurements using the Eagle Technologies RF Bridge

Vector Impedance Antenna Analyzer. User s Manual. Revision Updated to Firmware Version

Chanalyzer Lab. Chanalyzer Lab by MetaGeek USER GUIDE page 1

Easy start with UWB technology

PN9000 PULSED CARRIER MEASUREMENTS

DATASHEET. X-band Transmitter

Advanced Test Equipment Rentals ATEC (2832)

TABLE OF CONTENTS 1. GENERAL INFORMATION... 4

PC Tune PC Tune Test Procedures for 5100 Series Portable Radios

WE-525T Antenna Analyzer Manual and Specification

RM Italy HLA-305V HF Amplifier Test Report

TEST REPORT. For RFID READER/WRITER. In conformity with. FCC CFR 47 Part15 Subpart C

Important safety instructions

Spectrum Analyzers. 2394A 1 khz to 13.2 GHz Spectrum Analyzer.

User's Manual F10G-5S-LCD 1 / 20 BOOST CELL PHONE SIGNAL BOOSTERS MADE BY HUAPTEC

Signal Forge. Signal Forge 1000 TM Synthesized Signal Generator. Digital and RF Tester with 1 GHz Range. Key Features

PARAMETER CONDITIONS TYPICAL PERFORMANCE Operating Supply Voltage 3.1V to 3.5V Supply Current V CC = 3.3V, LO applied 152mA

This report contains the test setups and data required by the FCC for equipment authorization in accordance with Title 47 parts 2, and 87.

Vector Impedance Antenna Analyzer. User s Manual. Revision 0.7. Updated to Firmware Version 0.6.x

FCC PART 95 MEASUREMENT AND TEST REPORT. Powerwerx, Inc.

Transcription:

RF Explorer User Manual v1.05 - Page 1 of 13 RF Explorer User Manual Updated to firmware v1.05 Edition date: 2011/Mar/01 www.rf-explorer.com Please consider the environment before printing this manual.

RF Explorer User Manual v1.05 - Page 2 of 13 Table of Contents Introduction... 3 Features... 4 Spectrum Analyzer mode - Main Screen... 5 Using menus... 6 Frequency Menu... 7 Attenuator Menu... 9 Configuration Menu... 10 RF Generator mode... 11 Specifications... 12 Acknowledgments... 13 Regulatory Warning... 13 License... 13

RF Explorer User Manual v1.05 - Page 3 of 13 Introduction RF Explorer has been designed to be intuitive and easy to use. There is no need to learn large user manuals to get advantage of its advanced functionality. Most of the complexity inherent to full sized Spectrum Analyzers is simplified by the firmware. For instance, you do not need to adjust Resolution Bandwidth (RBW) everytime you select a different frequency span. Actually, you do not even need to know what RBW is. We welcome your feedback and look for ideas to make this manual more useful. Let us be in contact through official discussion list http://groups.google.com/group/rf-explorer.

RF Explorer User Manual v1.05 - Page 4 of 13 Features Pocket size and light weight Solid aluminum metal case Spectrum Analyzer mode with Peak Max, Normal and Averaging modes Support one of three popular ISM bands of choice: 433Mhz, 868Mhz or 915Mhz. Integrated RF Signal Generator for the ISM band of choice Lifetime free firmware upgrades available Open to new features requested by user community High capacity Lipo for 16hs+ of continuous run, rechargeable by USB Windows PC client Open Source Internal expansion port for future modules, will support additional bands including popular 2.4 Ghz

RF Explorer User Manual v1.05 - Page 5 of 13 Spectrum Analyzer mode - Main Screen When RF Explorer starts, it goes automatically to Spectrum Analyzer mode. As you can see on the screen, there is an X and Y axis, being X for frequency in MHZ and Y for power in dbm. In this case, the frequency span goes from 430.5 MHz to 439.5 MHz, and the amplitude (dynamic range) goes from -50 dbm to -110 dbm. Configuration settings such as amplitude reference and frequency span are preserved between sessions. The main screen automatically displays a small marker with a triangle shape. This will indicate the peak amplitude in the current frequency span, being the first line the frequency and the second line the amplitude at that particular point. The screen also includes an icon for USB connection (when connected to a PC as in this case) or a battery icon (when the battery power switch is in ON position). If you connect the RF Explorer to USB and the power switch is in ON at the same time, you are charging the internal battery, and in that case the USB and battery icon will blink to indicate that. There are three basic RF Explorer models available, one for each popular ISM frequency band as follows: 433M : 430-440Mhz or 868M : 860-870Mhz or 915M : 910-920Mhz Each one of these models can only operate on the respective band. In this manual, we will concentrate all examples and pictures on 433M only, but 868M and 915M operate exactly the same, except they work in a different band. We are working on internal expansion modules for your RF Explorer in case you want to work on multiple bands with the same unit, so you can leverage additional power to your RF Explorer for a very reasonable cost increase, whenever you need it.

RF Explorer User Manual v1.05 - Page 6 of 13 Using menus There are several menus in RF Explorer. They are organized on different screens, which you can iterate through by using the [Menu] key. If you click [Menu] button multiple times, you will visit every one of them: You can exit from any menu anytime by using the [Return] key. Note the last one is not actually a menu but a display of the current firmware version installed. You can see this same version screen when RF Explorer starts.

RF Explorer User Manual v1.05 - Page 7 of 13 Frequency Menu The first and probably most used menu is the one you can use to change frequency settings. The first time you open a Menu in a RF Explorer session, it will go to the Frequency Menu. This may change as we will see later, so everytime you click on [Menu] from Spectrum Analyzer main screen, you actually reopen the last menu you were working with. In this way you save time by not having to navigate through all the menus to go the same place where you were before. While you are at Frequency Menu, you can change the selected frequency band to display in two different but complementary ways: Center+Span: This is the traditional Spectrum Analyzer format all engineers are used to. You basically select the Center frequency at which the band will be displayed, and then a Frequency Span. Note this is limited to the range 430-439.995 Mhz (or equivalent in other models) and 0.1-9.995Mhz for the span. Low+High: This is unusual (despite its convenience) in most commercial Spectrum Analyzers. It is just another way to select the same parameters, which in the end is what will be displayed on the Spectrum Analyzer main screen. As you edit Center+Span or Low+High, the other values are updated accordingly, so feel free to use the method you prefer. In general, you will use Center+Span more frequently when you know the frequency you want to look at, and probably Low+High when you just want to look at a larger span to see what is happening in a specific range. To navigate through the menu, just use [Up] and [Down] keys to go to the option you want, then click on [Enter] to edit that option, [Left] or [Right] to go to the digit you want to change, and [Enter] to confirm or [Return] to cancel. Let s change the Span to 6.5Mhz, see how Low+High Frequency values are updated automatically: And now click on [Return] to close the menu and go back to Spectrum Analyzer main screen.

RF Explorer User Manual v1.05 - Page 8 of 13 The new frequency range is in place. Let s now repeat the process to change the span to 2.5Mhz. Therefore click on [Menu] again, note as the previous menu option (Freq Span) remains selected, and then update it to 2.5Mhz, then click on [Return] to go back to main screen. The new frequency range is in place, but what is interesting now is how you can actually move the center frequency right or left from the very same Spectrum Analyzer main screen, with no need to go to Menu again and again. To do that, just click on [Right] or [Left] while Spectrum Analyzer main screen is active, and you will move the Center Frequency to the right or left accordingly, by half of the span everytime. So in this case where the span is 2.5Mhz, you will effectively move the Center Frequency to 1.25Mhz right or left with a simple key press. Note you are limited by frequency limits of your RF Explorer model so in this case you cannot go lower than 430 nor higher than 439.995 Mhz. This direct method is very convenient when the selected span is narrow.

RF Explorer User Manual v1.05 - Page 9 of 13 Attenuator Menu The amplitude reference settings in the Y axis is what you can change using this menu. To get there, use the familiar [Menu] key, which will iterate through all RF Explorer menus till you get to the one you want. This menu has a few interesting options: Calculator offers three modes to display data, to change mode click on [Enter] key: o Max: Peak values are used from the last sweep Iterations (see menu option at the bottom). In this case, the Peak values from last 4 sweep iterations. This is the standard mode you will want to use to detect rapidly changing DSS signals or find for worst case channel occupancy. o Average: Arithmetic media average is calculated over the last sweep Iterations. You will likely use this mode to average noise floor out, particularly useful in constant wave (CW) signals display. o Normal: No calculation is done, just raw data as result of the sweep. Top / Bottom dbm: Use these options to change the lower and higher display margins for the amplitude reference. These are limited from -1 to -110 dynamic range boundaries. Iterations: The number of sweep data iterations to perform calculations on. It goes from 2 to 32. For a simple test, do a change on Top dbm reference and define it as -70 dbm. Then click on [Return] to go back to Spectrum Analyzer main screen. As you can see, the reference is now lower and signal goes higher in the display, particularly the noise floor. As this is something you will like to change very frequently, the RF Explorer Spectrum Analyzer main screen offers two keyboard shortcuts: [Up] and [Down] arrow keys can be used to increase or decrease Top dbm respectively by 5dBm each time. This shortcut, together with [Left] and [Right] for moving Center Frequency as described before, are very convenient to make configuration changes real-time with no need to visit the Menu.

RF Explorer User Manual v1.05 - Page 10 of 13 Configuration Menu Same as you did with other menus, just click on [Menu] as many times as needed to rotate between the different menus available, till you get to the Config menu. There are a few configuration settings available in the RF Explorer to customize your unit based on your preference or usage conditions: Operational Mode: Currently available are two modes, but more are coming with new Firmware upgrades: o Normal SA: This is the standard Spectrum Analyzer mode the RF Explorer always selects by default when you restart the unit. o RF Gen: RF Signal Generator, for more info please refer to specific section later in this document. Backlight: Several levels of display backlight. RF Explorer has good visibility indoor and outdoor, including direct sunlight. The level of backlight should be the appropriate for each condition, and you may want to limit backlight brightness to preserve battery capacity. Contrast: There are 10 different display contrast levels to choose from. USB Bauds: Default is 500Kbps, which is also the recommended setting. In the rare case you experience a problem when connecting with the PC, you may want to change this to 2400bps slower speed. However, this is not recommended as the connection will go really slow, so do this only if there is a good reason to. The port speed in the RF Explorer and PC Client settings must match to properly establish a connection.

RF Explorer User Manual v1.05 - Page 11 of 13 RF Generator mode RF Explorer can generate a RF tone for easy testing other RF devices. You can activate RF Generator from the Config menu, and return to Spectrum Analyzer mode anytime by using [Menu] button and changing mode back to Normal SA. There are two basic configuration steps you need to know: Output frequency and Output power. Select the specific frequency you want to transmit and then click on Transmitter to switch it ON. Please note an important detail: You must have connected a proper 50 ohm antenna before you switch your transmitter on. If you switch the transmitter on without a proper antenna, you may damage the RF module of your RF Explorer, as the power amplifier will not have a load to feed. Think of the equivalent to an audio amplifier with no speakers running at full power, you are likely damaging the power transistors. If you are an RF expert you know you can really connect any 50 ohm load, not only an antenna. Therefore you can use also a RF 50 ohm dummy load, a coaxial with a proper termination, etc. If you use a load different than 50 ohm, the reflected wave may also damage the power amplifier, so be sure to use a proper load (including a proper antenna). There are three power levels, corresponding to 0 dbm (Low), 9 dbm (Med) and 20 dbm (High). Except you need full power for a range test, we suggest always use the lowest power level to minimize battery consumption and EMI radiation. Note local regulations must be respected, so double check you are not transmitting a tone with power or frequency that may interfere with other equipment. The RF Generator is limited to the same frequency band than the Spectrum Analyzer; therefore you can transmit any frequency of choice in the specific band of your model.

RF Explorer User Manual v1.05 - Page 12 of 13 Specifications Currently available in three models, based on frequency range: o 430-440Mhz o 860-890Mhz o 910-920Mhz High contrast graphics LCD 128x64 pixels, great visibility outdoors even on sunlight PC Windows client supports WindowsXP\Vista\Win7 both 32 and 64bits Backlight for great indoor visibility Internal 860mAh high capacity LiPo battery, rechargeable by a powered USB Amplitude resolution: 0.5dBm Dynamic range: -110dBm to 0dBm Absolute Max input power: +5dBm Average noise level (typical): -105dBm RF Generator amplitude: 0dBm to 20dBm Standard 50 ohm SMA connector Matching 50 ohm calibrated antenna included Frequency stability and accuracy (typical): +-10ppm Amplitude stability and accuracy (typical): +-3dBm Frequency resolution: 1Khz Resolution bandwidth (RBW): automatic 2.6Khz to 80Khz Weight: 185g Size: 113x70x25 mm

RF Explorer User Manual v1.05 - Page 13 of 13 Acknowledgments RF Explorer couldn t be a reality without the seriousness and high levels of professionalism of Eric Pan and team in Seeed Studio Technology. I really want to thank him for his dedication, as well as Kevin and Icing for the many hours resolving implementation issues to produce this unit with high quality components at a very affordable price. We all hope you find it useful, and make Radio Frequency more accessible to the non-experts everywhere. We are committed to create tutorials, projects and kits to help you tinkering and experimenting in the RF space. If you think you can contribute on RF tutorials and examples, let us know at http://groups.google.com/group/rf-explorer Regulatory Warning This equipment is intended for use in a laboratory test environment only. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to subpart J of part 15 of FCC rules, which are designed to provide reasonable protection against radio frequency interference. Operation of this equipment in other environments may cause interference with radio communications, in which case, the user is required to take whatever measures may be required to correct this interference his own expense. License RF Explorer embedded firmware is copyrighted by Ariel Rocholl, 2010-2011. RF Explorer PC Client is Open Source under GPL v3, so you are free to modify, distribute and use it based on GPL terms.