Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays

Similar documents
Image evaluation method for digital mammography with soft-copy reading using a digital phantom

A pre-processing technique to improve the performance of a computer-aided detection scheme in mammography

Optimization of Digital Mammography Resolution Using Magnification Technique in Computed Radiography 1

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Comparison between film-screen and computed radiography systems in Brazilian mammography

Filters. Materials from Prof. Klaus Mueller

Image Scaling. This image is too big to fit on the screen. How can we reduce it? How to generate a halfsized

1.Discuss the frequency domain techniques of image enhancement in detail.

Differentiation of Malignant and Benign Masses on Mammograms Using Radial Local Ternary Pattern

CS6670: Computer Vision Noah Snavely. Administrivia. Administrivia. Reading. Last time: Convolution. Last time: Cross correlation 9/8/2009

An Improved Method of Computing Scale-Orientation Signatures

A Study On Preprocessing A Mammogram Image Using Adaptive Median Filter

Display of mammograms on a CRT

restoration-interpolation from the Thematic Mapper (size of the original

Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

Mammography is a radiographic procedure specially designed for detecting breast pathology Approximately 1 woman in 8 will develop breast cancer over

SUSPENSION CRITERIA FOR IMAGE MONITORS AND VIEWING BOXES.

Announcements. Image Processing. What s an image? Images as functions. Image processing. What s a digital image?

Radiology Physics Lectures: Digital Radiography. Digital Radiography. D. J. Hall, Ph.D. x20893

Comparison of edge enhancements by phase contrast imaging and post-processing with unsharp masking or Laplacian filtering

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

LAB 2: Sampling & aliasing; quantization & false contouring

Improved Tomosynthesis Reconstruction using Super-resolution and Iterative Techniques

ADC COMPACT FULL-LEG/FULL-SPINE APPLICATION SOFTWARE USER MANUAL

Defense Technical Information Center Compilation Part Notice

Image Display and Perception

Investigation of the line-pair pattern method for evaluating mammographic focal spot performance

30 lesions. 30 lesions. false positive fraction

Appropriate Inspection Distance of Digital X-Ray Imaging Equipment for Diagnosis

Digital Detector Array Image Quality for Various GOS Scintillators

THE ART OF THE IMAGE: IDENTIFICATION AND REMEDIATION OF IMAGE ARTIFACTS IN MAMMOGRAPHY

Image Enhancement in Spatial Domain

Amorphous Selenium Direct Radiography for Industrial Imaging

Use of Wavelet Multiresolution Analysis to Reduce Radiation Dose in Digital Mammography

Antialiasing and Related Issues

Image Sampling. Moire patterns. - Source: F. Durand

Do you have any other questions? Please call us at (Toll Free) or , or

8.2 IMAGE PROCESSING VERSUS IMAGE ANALYSIS Image processing: The collection of routines and

DICOM Correction Item

Attikon, Rimini 1, , Athens, Greece , Athens, Greece , Athens, Greece

Pseudocolour Image Processing in Digital Mammography

PERFORMANCE MEASUREMENT OF MEDICAL IMAGING SYSTEMS BASED ON MUTUAL INFORMATION METRIC

Published text: Institute of Cancer Research Repository Please direct all s to:

One Week to Better Photography

Preliminary Assessment of High Dynamic Range Displays for Pathology Detection Tasks. CIS/Kodak New Collaborative Proposal

Veraviewepocs 2D High Speed Panoramic X-Ray Crystal Clear Images with Reduced Radiation

X-ray light valve (XLV): a novel detectors technology for digital mammography*

A comparison between medical-grade liquid crystal display (LCD) and ipad color imaging

Evaluation of a quality control phantom for digital chest radiography

Multimedia Systems Giorgio Leonardi A.A Lectures 14-16: Raster images processing and filters

ECC419 IMAGE PROCESSING

Optimized Image Scaling Processor using VLSI

Digital Quality Control Phantom for X-ray Mammography Image

Frequency Domain Enhancement

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Acquisition, Processing and Display

Abstract. ZEIGLER, GARY BOYCE, II. Direct Detection of Microcalcification Pairs in Simulated

While digital techniques have the potential to reduce patient doses, they also have the potential to significantly increase them.

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

MAMMOGRAM ENHANCEMENT USING QUADRATIC ADAPTIVE VOLTERRA FILTER- A COMPARATIVE ANALYSIS IN SPATIAL AND FREQUENCY DOMAIN

Image Processing for feature extraction

TESTING FLAT-PANEL IMAGING SYSTEMS: What the Medical Physicist Needs to Know. JAMES A. TOMLINSON, M.S., D.A.B.R. Diagnostic Radiological Physicist

On spatial resolution

COMPUTED RADIOGRAPHY CHAPTER 4 EFFECTIVE USE OF CR

Exposure Indices and Target Values in Radiography: What Are They and How Can You Use Them?

General Hospital Catalog

in association with Getting to Grips with Printing

Performance Evaluation of Edge Detection Techniques for Square Pixel and Hexagon Pixel images

Dr. J. J.Magdum College. ABSTRACT- Keywords- 1. INTRODUCTION-

XXXX - ANTI-ALIASING AND RESAMPLING 1 N/08/08

LAB MANUAL SUBJECT: IMAGE PROCESSING BE (COMPUTER) SEM VII

Preliminary validation of content-based compression of mammographic images

EMVA1288 compliant Interpolation Algorithm

Acceptance Testing of a Digital Breast Tomosynthesis Unit

Image Interpretation System for Informed Consent to Patients by Use of a Skeletal Tracking

Sampling and pixels. CS 178, Spring Marc Levoy Computer Science Department Stanford University. Begun 4/23, finished 4/25.

DodgeCmd Image Dodging Algorithm A Technical White Paper

Using the Advanced Sharpen Transformation

Resolution test with line patterns

Comparison of computed radiography and filmõscreen combination using a contrast-detail phantom

Diffraction-enhanced X-ray Imaging (DEXI) Medical Solutions. More information using less radiation

Testing a wavelet based noise reduction method using computersimulated

Effect of Backscattered Radiation on X-Ray Image Contrast

X-RAY MEDICAL EQUIPMENT

Spatial Analyst is an extension in ArcGIS specially designed for working with raster data.

Features and Weaknesses of Phantoms for CR/DR System Testing

Computed Radiography

The Evaluation of Collimator Alignment of Diagnostic X-ray Tube Using Computed Radiography System

AN APPROXIMATION-WEIGHTED DETAIL CONTRAST ENHANCEMENT FILTER FOR LESION DETECTION ON MAMMOGRAMS

Image Pyramids. Sanja Fidler CSC420: Intro to Image Understanding 1 / 35

Effect of Pixel Resolution on Texture Features of Breast Masses in Mammograms

7/24/2014. Image Quality for the Radiation Oncology Physicist: Review of the Fundamentals and Implementation. Disclosures. Outline

FEATURE. Adaptive Temporal Aperture Control for Improving Motion Image Quality of OLED Display

IMPLEMENTATION USING THE VAN HERK/GIL-WERMAN ALGORITHM

Cassette DR Solution. FDR D-EVO G43i. Square shaped cassette enabling enhanced operability and multipurpose use ISS. Wireless

LCD handheld displays characterization by means of the MTF measurement

Digital Image Processing

Chapter 3 Novel Digital-to-Analog Converter with Gamma Correction for On-Panel Data Driver

CR Basics and FAQ. Overview. Historical Perspective

Fundamental and Clinical Studies for Effectiveness of Zero-filling Interpolation on k-space for Improvement of Sharpness in Magnetic Resonance Imaging

Transcription:

Original Paper Forma, 29, S45 S51, 2014 Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays Akiko Ihori 1, Chihiro Kataoka 2, Daigo Yokoyama 2, Naotoshi Fujita 3, Naruomi Yasuda 4, Akihiro Sugiura 4 and Yoshie Kodera 2 1 Graduate School of Medical Sciences, Nagoya University, Nagoya 461-8673, Japan 2 School of Health Sciences, Nagoya University, Nagoya 461-8673, Japan 3 Department of Radiological Technology, Nagoya University Hospital, Nagoya 466-8560, Japan 4 School of Health Sciences, Gifu University of Medical Science, Seki 501-3892, Japan E-mail address: aihori0312@gmail.com (Received November 14, 2010; Accepted April 10, 2011) In soft-copy diagnosis, each pixel of an X-ray detector is displayed as the corresponding pixel of a liquid crystal display (LCD). However, when a mammographic image is displayed on an LCD for the first time, the entire image is reduced. We examined the influence of differences in LCD image-reduction rates on the signaldetection performance by observational experiments. We created a simulated image similar to Burger s phantom and reduced it by using the nearest neighbor, bilinear, and bicubic interpolation methods. We displayed the reduced images on LCDs with different numbers of pixels and examined the signal-detection performance with each interpolation method. The signal-detection performance deteriorated as the image-reduction rate increased irrespective of the interpolation method. Among the interpolation methods, the nearest neighbor method resulted in the worst signal-detection performance, and the bilinear method was the most suitable for image reduction. Mammographic images are mostly reduced for viewing on an LCD. Such reduction changes the appearance of microcalcifications. Therefore, depending on their size and distribution, microcalcifications observed in these images may be missed on an LCD. Key words: Liquid Crystal Display, Interpolation Method, Phase-Contrast Mammography, Simulation Image 1. Introduction Recently, hospitals have begun to digitize medical images. Further, medical-image diagnostic systems are changing from films to liquid crystal displays (LCDs), increasing the need for LCDs as diagnostic monitors. The image quality of LCDs differs according to the purpose and environment. Especially, high image quality is required to display mammographic and chest X-ray images, including those of microscopic lesions and low-contrast shadows. Therefore, higher image quality than that of the conventional X-ray films is necessary for good display performance of LCDs (Pisano et al., 2005). In soft-copy diagnosis, each pixel of an X-ray detector is displayed as the corresponding pixel of an LCD. Even with high-resolution LCDs, not all pixels of a mammographic image can be displayed on 1 screen, because of the high number of pixels of such images. Especially, magnified images obtained by phase-contrast mammography (PCM) have about 70-million pixels (Thoyama et al., 2006). PCM has an edge emphasis effect on the object and the highest image resolution at 25-µm pixel pitch. Therefore, lesions such as microcalcifications and tumors can be clearly viewed in PCM images compared with the conventional mammographic images. For phase-contrast imaging, the object and the X-ray detector should be located at some distance from each other, then it is magnification radiography. Because PCM images are obtained by a half-cut size cassette, it is impossible to display them on 1 screen even Copyright c Society for Science on Form, Japan. by using an LCD of 5-million pixels, the recommended diagnostic monitor for such images. When a PCM image is displayed on an LCD for the first time, the entire image is reduced. Doctors diagnose breast cancer by using mammograms; therefore, the entire image should be displayed to enable identification of any abnormality, and the diagnostic performance decreases when the entire image is not displayed on the LCD. In addition, images of both breasts are displayed on the LCD simultaneously; therefore, the imagereduction rate of a 2-image LCD increases compared with that of a single-image LCD. In this study, we created a simulated image of microcalcifications and examined alteration in the shape of their signals in images reduced by using various interpolation methods. We aimed to find a suitable interpolation method for reducing PCM images on LCDs and improving the current LCD-based diagnostic technology. 2. Methods 2.1 Simulated image A mammographic finding indicating breast cancer is microcalcification, consisting of a small calcium deposit of 0.2 0.5 mm diameter (dos Santos Romualdo et al., 2009). We created a simulated image of microcalcifications similar to Burger s phantom (Fig. 1), which changes the diameter and contrast of round signals. A round signal imitates a microcalcification in a mammographic image. The simulated image was composed of 288 round signals in 18 rows and 16 columns. In the vertical direction, the diameter of the signals increased logarithmically from 1 to S45

S46 A. Ihori et al. Simulation Image Uniform Image Fig. 1. Simulated image comprising 18 rows and 16 columns. The left signals have higher contrast than the right signals. The signal diameter reduces toward the bottom, and the signals in the lower right region are difficult to detect. The simulated image was merged to an image uniformly exposed by PCM at 24 kv and 25 mas. Table 1. Image-reduction rate. LCDs Number of Pixels/LCD Reduction rate (%) Number of Pixels/Reduced image 2 million 1200 1600 16.87 1105 1480 3 million 1536 2048 21.60 1430 1916 5 million 2028 2560 27.00 1625 2177 5 million (split-screen display) 1023 1370 14.46 910 1219 Fig. 2. Interpolation functions (a) nearest neighbor method (b) bilinear method (c) bicubic method. 200 pixels. In the horizontal direction, the pixel value of the signals increased by 5% from 5% to 95% against the background (Ishida et al., 1984). The simulated image was merged to an image uniformly exposed by PCM at 24 kv and 25 mas. Its matrix size was the same as that of the PCM image. 2.2 Image-reductionrate The image-reduction rate was calculated as the ratio of the number of pixels per LCD to that per reduced image when the simulated image was displayed on LCDs of 2-, 3-, and 5-million pixels. Moreover, we examined the signal-detection rate at specific image-reduction rates when displaying right and left mammographic images simultaneously on a 5-million-pixel LCD. Table 1 shows the number of pixels per LCD used in this study and the corresponding image-reduction rates. 2.3 Interpolation methods The simulated image was reduced by using 3 interpolation methods: the nearest neighbor, bilinear, and bicubic methods (Parker et al., 1983; Lehmann et al., 1999). Figure 2 shows the waveform of each function. 2.3.1 Nearest neighbor method From a computational standpoint, the easiest interpolation algorithm to implement is the so-called nearest neighbor algorithm, in which each pixel is given the value of the sample closest to it. Four grid points are needed to evaluate the interpolation function in the 2-dimensional nearest neighbor method. The interpolation kernel for each direction is as follows: Nearest neighbor h(x) = { 1, 0 x < 0.5 0, elsewhere. Therefore, strong aliasing and blurring effects are associated with the nearest neighbor method for image interpolation. (1)

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays S47 Fig. 3. Results of the observational experiment for comparing the signal-detection performances among the image-reduction rates. Fig. 4. Results of the observational experiment for comparing the detection performances among the interpolation methods. The circles indicate values significantly different from those obtained with the other methods. 2.3.2 Bilinear method For separated bilinear interpolation, the values of both direct neighbors are weighted by their distance to the opposite point of interpolation. For linear interpolation, the interpolation kernel is as follows: Bilinear h(x) = { 1 x, 0 x < 1 0, elsewhere, where x is the distance between the point to be interpolated and the grid point being considered. The triangular function corresponds to a modest low-pass filter in the frequency domain. Therefore, the main disadvantages of linear interpolation are attenuation of the high-frequency components and aliasing of the data beyond the cutoff point into the low frequencies (Parker et al., 1983). 2.3.3 Bicubic method Cubic convolution interpolation determines the grey level value from the weighted average of the 16 closest pixels to the specified input coordinates and assigns that value to the output coordinates. The kernel is positive in the interval from zero to 1 and negative from 1 to 2. Frequencies directly below the cutoff point are amplified slightly, and the transition between the pass band (2) and the stop band is quite sharp. The cubic convolution interpolation kernel is as follows: { (a + 2) x 3 Bicubic (a + 3) x 2 +1, 0 x < 1 h(x) = a x 3 5a x 2 +8a x 4a, 1 x < 2 0, elsewhere, (3) where x is the distance between the point to be interpolated and the grid point being considered and a is usually set to 0.5 or 0.75. In this study, we set a to 0.5. 2.4 Observational experiments For the observational experiments, the room illumination was set to about 50 lx. The window width was a difference between the maximum value and the minimum value of the pixel value obtained from the histogram of the simulation picture. The window level was center values between the maximum value and the minimum value. The window width and level were fixed at 847 and 531, respectively. We set the maximum luminance of the LCD to 500 cd/m 2,and the viewing distance from the LCD was arbitrary. The reduced images were randomly displayed on a 5-million-pixel LCD by using the same software and the signal-detection

S48 A. Ihori et al. Fig. 5. Answer sheets of the 10 observers when the images were reduced on the 5-million-pixel LCD. The black and white squares indicate undetected and detected signals, respectively. The squares are sequentially arranged from the bottom according to signals of 1-pixel, 2-pixel, 3-pixel, and 4-pixel sizes, representing microcalcifications of 0.05-, 0.06-, 0.08-, and 0.10-mm diameter, respectively. performance with each interpolation method was examined. Six students who are learning about radiography in the university and four graduate students in a master s course participated as observers. They viewed the reduced images and reported whether the signals could be detected. We defined the signal-detection rate as the ratio of the number of detected signals to the number of all signals. This study was approved by the ethics committee of Nagoya University. 3. Results Figure 3 shows the results of the observational experiment for comparing the signal-detection performances among the image-reduction rates. The signal-detection performance deteriorated as the image-reduction rate increased irrespective of the interpolation method. There was no significant difference between the 2-million-pixel and the 5- million-pixel split-screen LCDs with the nearest neighbor method ( p < 0.05 by Scheffe s paired comparison). However, the other groups showed significant differences. Figure 4 shows the results of the observational experiment for comparing the signal-detection performances among the interpolation methods. When the imagereduction rate was high, the nearest neighbor method resulted in the worst signal-detection performance, whereas the bicubic method caused the worst signal-detection performance at a low image-reduction rate. Figure 5 shows the answer sheets of the 10 observers when the images were reduced on the 5-million-pixel LCD.

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays S49 Fig. 6. Answer sheets of the 10 observers when the images were reduced on the 3-million-pixel. The black and white squares indicate undetected and detected signals, respectively. The squares are sequentially arranged from the bottom according to signals of 1-pixel, 2-pixel, 3-pixel, and 4-pixel sizes, representing microcalcifications of 0.05-, 0.06-, 0.08-, and 0.10-mm diameter, respectively. Because of their small diameter and low contrast, the signals located at the bottom-right of the reduced images were not detected. Figure 6 shows the answer sheets of the 10 observers when the images were reduced on the 3-million-pixel. The 2 bottom-most lines, representing signals of 1-pixel and 2- pixel sizes and indicating microcalcifications of 0.05- and 0.06-mm diameter, respectively, were not detected with any interpolation method. However, there was a clear demarcation between the signals that could be detected and those that could not be detected from the third and fourth bottommost lines (microcalcifications of 0.08- and 0.10-mm diameter, respectively). 4. Discussion The 5-million-pixel LCD is recommended for diagnosing mammographic images because the signal-detection rate at this size is higher than that at the other sizes. However, the signal-detection performance deteriorates as the imagereduction rate increases. When the image-reduction rate is high, signals disappear in the reduction process because of their small size. In general, the size of an image does not change because it is displayed on an LCD suitable for its size. However, in this study, we displayed all the images on a 5-million-pixel LCD. Therefore, the entire image reduced as the image-reduction rate increased and the difference in the image size influenced the signal-detection performance. When the image-reduction rate was high,

S50 A. Ihori et al. Fig. 7. Profiles of the interpolation methods for the 3-pixel (0.08 mm, right image) and 4-pixel (0.10 mm, left) signals of the 3-million-pixel. the signal-detection performance with the nearest neighbor method was worse than that with the other interpolation methods. The nearest neighbor method involves substitution of a value closest to the position to be detected. Therefore, the noise property deteriorates and the signaldetection rate decreases in this method. When the imagereduction rate was low, the signal-detection performance with the bicubic method was the worst. Because the function of the bicubic method had a negative value, the noise was emphasized as the image-reduction rate increased. At all the image-reduction rates, the bilinear method yielded the best results. When the image-reduction rate was high, only small and low-contrast signals were not detected. However, as the rate of image reduction decreased, small signals should not necessarily disappear, and the signals that could not be detected became a periodic form. Figure 7 shows the profiles of the interpolation methods for 3-pixel (microcalcification of 0.08-mm diameter) and 4-pixel (microcalcification of 0.10- mm diameter) signals of the 3-million-pixel LCD. These profiles indicate that the signals disappeared periodically when the image was reduced and they exhibited different cycle regularities when the signals disappeared depending on the interpolation method. The signal-detection rate was lower with the nearest neighbor method than with the other interpolation methods. The result is noteworthy because not only small signals but also several 0.1-mm-diameter signals disappeared in this method. 5. Conclusions The signal-detection performance deteriorates as display size in the LCD became small. The bilinear method is the most suitable for image reduction. Mammographic images are mostly reduced for viewing

Observer Performance of Reduced X-Ray Images on Liquid Crystal Displays S51 on LCDs. Such reduction changes the appearance of microcalcifications. Therefore, depending on their size and distribution, such lesions may be missed on LCDs. In addition, microcalcifications of 0.1-mm diameter might disappear when a mammographic image is reduced by using the nearest neighbor method; such images should be displayed on LCDs with fewer pixels. References dos Santos Romualdo, L. C., da Costa Vieira, M. A. and Schiabel, H. (2009) Mammography Images Restoration by Quantum Noise Reduction and Inverse MTF Filtering, SIBGRAPI, 180 185, 2009 XXII Brazilian Symposium on Computer Graphics and Image Processing. Ishida, M., Doi, K., Loo, L. N. et al. (1984) Digital image processing: Effect on detectability of simulated low-contrast radiographic patterns, Radiology, 150, 569 575. Lehmann, T. M., Gonner, C. and Spitzer, K. (1999) Interpolation methods in medical image processing, IEEE Trans. Med. Imag., 18(11), 1049 1075. Parker, A. J., Kenyon, R. V. and Troxel, D. E. (1983) Comparison of interpolating methods for image resampling, IEEE Trans. Med. Imag., 2(1), 31 39. Pisano, E. D., Gatsonis, C., Hendrick, E. et al. (2005) Diagnostic performance of digital versus film mammography for breast cancer screening, N. Engl. J. Med., 353, 1773 1783. Thoyama, K., Katafuchi, T. and Matsuo, S. (2006) Clinical implications of phase-contrast imaging in mammography, Medical Imaging and Information Sciences, 23(2), 79 84.