LUX/FC LED Light Meter TM-201L / TM-209 User s manual

Similar documents
LUX/FC LED Light Meter TM-201L / TM-209/TM-209N /TM-209M

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

EasyView Light Meter with Memory

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

Model ST Instruction Manual. Light Meter. reedinstruments www.

Model Digital Light Meter

Dawson DSM150. Digital Light Meter User s Manual

Advanced Test Equipment Rentals ATEC (2832)

DIGITAL LIGHT METER TES-1337 INSTRUCTION MANUAL CONTENTS

3423 LUX HiTESTER INSTRUCTION MANUAL

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

INSTRUCTION MANUAL PCE-222

RF/High Frequency Meter HF-A3G

Heavy Duty Meter Model

LIGHT INTENSITY METER

Manual DATALOGGING LIGHT METER - PCE-174

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

User Guide. EasyView Digital Light Meter. Model EA31

DIGITAL ILLUMINANCE METER MODEL 1308 INSTRUCTION MANUL

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

Magnetic Field Meter EM-191

RF three-axis Field Strength Meter TM-196

Cat# Multi-functional LED Light Meter

DIGITAL MULTIMETER OPERATOR S MANUAL

User s Manual /51012/51021 Digital Lux Meter. Keep this manual in a safe place so that you can refer to it when necessary.

Instruction Manual. IM Axis RF Field Strength Meter

MS6612T Multi-functional Light Meter USER MANUAL

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL DLM2

TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Dawson DDM190. Digital Multimeter User s Manual

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Triple Axis RF/High Frequency Meter HF-B3G. User s Manual HB4HFB3G0000

USER GUIDE. IR Thermal Scanner. Model IRT500

Digital Multimeter, Pen Type

Microwave Meter. Instruction Manual

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

True RMS. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, REL, Capacitance Hz, Duty, ACV, ACA, DCV, DCA, Ohms

Pro Triple Axis RF/High Frequency Meter HF-B8G. User s Manual HB4HFB8G0000

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

QUANTUM PHOTO-METER LX OPERATING INSTRUCTIONS. ... Three decimal points only displayed Overrange reading. Adjust Range. ( X 1000will light up)

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

CHAPTER VII ELECTRIC LIGHTING

EM5. Multifunctional Environmental Meter. Sealed Unit Parts Co., Inc. User Manual

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

MS2030 CAT III 600 V A V AUTO RS232

Read and be familiar with this manual before operating or servicing this device. To ensure operator, technician, and patient safety, use only as

User s Manual Digital Illuminance Meter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

0.01kV (0 to ±0.99 kv)

Dawson DDM230C. True RMS Multimeter with Bar Graph Display User s Manual

Physics of Light. Light: electromagnetic radiation that can produce a visual sensation.

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

daylight Spring 2014 College of Architecture, Texas Tech University 1

2000 A DCA/ACA CLAMP + DMM,

ET-3888 True RMS Clamp Meter. User Manual

Caution Symbol. AUTO RANGE MULTIMETER CAT III-1000 V category, Auto range, Peak hold Bar graph display, Max/Min, REL, Cap.

DDM350 Pen-Type Digital Multimeter User s Manual

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER GUIDE. Mini InfraRed Thermometer with Laser Pointer MODEL 42500

Model R2002. Instruction Manual. Infrared Thermometer. reedinstruments www.

400Amp True RMS AC Clamp Meter + NCV

Photometry for Traffic Engineers...

MAVOLUX 5032C/B Digital Luxmeter

DOUGLAS COUNTY ZONING RESOLUTION Section 30 Lighting Standards 3/10/99. -Section Contents-

CONTENTS MS2033A. 1.Introduction Safety Information...01

Nuclear Associates

Photometry for Traffic Engineers...

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

Illuminance Meter. series

Visit us at

ProfiScale MULTI Multimeter

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

Pen-type DIGITAL MULTITESTER

Digital Clamp Meter Model: &

GUIDELINES FOR GOOD EXTERIOR LIGHTING PLANS

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

MK350 Portable Spectrometer

DEFINITION OF ILLUMINANCE

600A Clamp Meters w/tightsight Display

Basic Lighting Terms Glossary (Terms included in the basic lighting course are italicized and underlined)

Manual. Operators. DeVORE AVIATION CORPORATION OF AMERICA. Flash Measuring Gun. Patent #5,654,794

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Application Notes Photoconductive Cells

LIGHT TRANSMITTER OPERATION MANUAL. 4 to 20 ma. Model : TR-LXT1A4

FSP-211 DIGITAL HIGH/LOW PIR FIXTURE INTEGRATED SENSOR

MT /6 Smart Digital Clamp Meter. User s Manual 1 st Edition, 2016 Copyright by Prokit s Industries Co., Ltd.

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

Instruction Manual ET4 ELECTRICAL TESTER

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

MW3105 DIGITAL CLAMP MULTIMETER

Emitting and receiving element pitch: 10 mm in

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

Nuclear Associates Precision Photometer

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

FLUO invisible Ink Densitometer Instruction Manual

Transcription:

LUX/FC LED Light Meter TM-201L / TM-209 User s manual HB2TM2090000

CONTENTS 1. Description... 1 2. Safety Precaution... 1 3. Preface... 2 4. features... 3 5. Specifications... 4 6. Operation... 5 7. Luminous intensity measurement (TM-209)... 9 8. Instrument Description of TM-201L... 10 9. Instrument Description of TM-209...11 10. Attention... 13 11. Recommended Levels of Illumination... 14 12. Battery Replacement... 16 13. End of life... 16

1. Description Measures light from visible luminaries equipped with white light LED, fluorescent, metal halide, high-pressure sodium and incandescent sources. 2. Safety Precaution CAUTION Be extremely careful for the following conditions while measuring Do not operate the meter under the environment with explosive gas (material), combustible gas (material) steam or filled with dust. In order to avoid reading incorrect data, please replace the battery immediately when the symbol appears on the LCD. In order to avoid the damage caused by contamination or static electricity, do not touch the circuit board before you take any adequate action. Operating Environment: Indoors use. This instrument has been designed for being used in an environment of pollution degree 2. Operation Altitude: Up to 2000M. Operating Temperature & Humidity: 5 ~ 40, 0%~ 80%RH. Storage Temperature & Humidity: -10 ~ 60, 0%~ 70%RH. EMC: EN61326-1(2006), IEC 61000-4-2(2008, IEC 61000-4-3(2006) + (2007). EN-1

3. Preface The flux of light received in a unit area of a certain side being shown is popularly known as illumination. The measuring unit in both United Kingdom and America is known as footcandles light, but in Europe it is also known as meter candlelight. One foot-candles light is the illumination of light that falls on one side which is one foot away from a one foot-candlelight and exactly intersecting with the light. Its abbreviated form is written as 1 Fc=1 Lm/ft, similarly, one-meter candlelight is the illumination of light that falls on a side which is one meter away from a one meter candlelight and exactly intersecting the light. It is also called Lux i,e. the flux of light being received in each sq. meter is called the illumination of one lumen. 1 FC=10.764 LUX, 1 LUX=0.09290 FC, therefore,nbr. of foot (meter) candlelight = Nbr. of Lumen Area(sq. foot or sq. meter) Nbr. of Lumen=Nbr. of foot (or meter)x area EN-2

4. Features Overload Indication: LCD screen will show OL on the upper left-hand corner. Low battery Indication. Sampling Rate: 2.5 times per second for digital display. Spectral response close to CIE luminous spectral efficiency. Cosine Angular corrected. According to JIS C 1609:1993 and CNS 5119 general A class Specifications. Measuring lights source: LED white light and all visible light. Measuring intensities of illumination in Lux or footcandles. Many applications include: Warehouses, factories, office buildings, restaurants, schools, library, hospitals, photographic, many video, parking garages, museums, art galleries, stadiums, building security. Data hold. Maximum hold.(tm-201l) Maximum/Average/Minimum Hold.(TM-209) Zero adjustment. Auto power off and disable function.(tm-209) Auto ranging.(tm-209) EN-3

5. Specifications Display of TM-201L Display of TM-209 Sensor Measuring Range of TM-201L Measuring Range of TM-209 Accuracy 2000 count, maximum display 1999 4000 count, maximum display 3999 Silicon photodiode and filter 200,2000, 20000,200000 Lux 20,200,2000,20000 Footcandles 40,400,4000, 40000,400000 Lux 40,400,4000,40000 Footcandles ±3% (Calibrated to standard incandescent lamp 2856 K and corrected LED day while light spectrum) 8% other visible light source(tm-201l) 6% other visible light source(tm-209) Angle deviation 30 ±2% from cosine 60 ±6% characteristics 80 ±25% Power Supply 9V NEDA 1604, IEC 6F22, JIS 006P battery x 1pc Battery life About 200 hours Dimensions Weight Accessories Meter: 38 (H) x 55(W) x 130(L) mm 1.5(H)x 2.2(W) x 5.1(L) inch Sensor: 25(H) x 55(W) x 80(L) mm 9.8H)x 2.2(W) x 3.1(L) inch 250 g (include battery) User s manual, carrying case, 9V battery Length of wring for light sensor: Approx. 1.5M EN-4

6. Operation 1. Press the button to turn power on or off. 2. Remove sensor cap and place the sensor perpendicular to the light. 3. Select LUX or FC. 4. When OL is shown on the LCD screen, press the button for useable reading. (TM-201L). 5. If you want to keep the reading value on the LCD screen permanently after testing, press the button. 6. When done testing, replace the sensor cover to protect the filter and sensor. Data Hold Freezes the reading present on the LCD screen at the moment the button is pressed. R(TM-201L) Press the manual ranging button for usable reading. EN-5

ZERO (TM-201L) Adjust to 0, ADJ to enable LCD to indicate 000 on the screen. ZERO(TM-209) Press the button for the zero adjustment if any digits appear on the LCD screen, when the light sensor cap is not attached CAP will be shown on the screen. Make sure that it is attached to the light sensor. M-H (TM-201L) Press button to Lockup data maximal value of measure data. MAX/AVG/MIN(TM-209) Press button simultaneously Lockup data maximum and average and minimum value of measure data. Press the button for more than 1 seconds to disable this feature. LX/FC(TM-201L) Illuminance Lux or Foot candle measuring unit button. EN-6

LX/FC/CD(TM-209) Illuminance Lux or Foot candle and luminous intensity measuring unit button. L.S.(TM-209) Light source selection 1 ~ 9 features, each light source can set correction parameters, default as 1.000. Calibration parameters can be set to 0.001 to 1.999, when the pressure L.S. button for more than 1 second, LCD L.S. below the LN flashing, pressure or change L1 to L9. Press LS button for less than 1 second, the digits of 1.000 on the lower right-hand corner of the screen will be flashing, pressure or, you can change the calibration parameters as to 0.995, the display changes immediately, set 350.0x0.996 = 348.6, Setup complete press for more than 1 second. L.S. (light source) factor: L1 LED white day light : 0.99. L2~L9 Default Standard light source A: 1.00. Auto-Power Off (TM-209) Power off automatically after approx. 5 minutes without using the meter. EN-7

Disable Auto Power Off (TM-209) TM-201L/TM-209 When the power is on, press the button for more than 1 second, to cancel or recovery automatically shutdown. Automatic shutdown feature is enabled If " shows on the screen. MEM(MOMORY) (TM-209) Press button for one second to store the data, the LCD screen will display M and NO. 01~NO.99. When the AVG shows on the right hand corner of the screen, press button at this moment, LCD will display AVG M and NO.01 ~ NO.99, and store the AVG value at present moment. READ (READ MEMORY)(TM-209) Pressure button for more than one second to display the stored values, the LCD will display M and NO. 01 ~ NO.99, press or keys to review all the stored values, for example, NO. 1 NO. 2 until NO. 99. If the stored data is AVG value, the screen will display AVG on the lower left-hand corner. Press the button for more one second to disable this feature. Clear memory (TM-209) When power is off, press and buttons together,then the screen will display CLr which means the memorized data is erased. EN-8

7. Luminous Intensity Measurement (TM-209) 1. Press the button to turn power on or off. 2. Remove sensor cap and place the sensor perpendicular to the light. 3. Press button for more than 1 second. 4. Press or button to select ft(feet)or m(meter). 5. Press button for less than 1 second. 6. Press or to set the distance between the light center of lamp and measurement base level. 7. Press button for less than 1 second. 8. Read the display. 9. Press the button for more 1 second to disable this feature. The luminous intensity is calculated using the following formula: Luminous intensity(cd)=illumination(lx)x distance(m 2 ) The preset maximum distance is 0.01 ~ 30.47 m or 0.01 ~ 99.99 ft. If a single light source is used and is regarded as a single-point light source, the luminous intensity of the light source can be calculated and displayed, by setting the distance from the light source to the measuring point. EN-9

8. Instrument Description of TM-201L 1. Display (LCD). 2. MAX HOLD. 3. Power Button: ON/OFF. 4. Lux/Fc button 5. DATA HOLD button. 6. Range button. 7. Photo detector. 8. Zero Adjustment. EN-10

9. Instrument Description of TM-209 1. Display (LCD). 2. Lux/Fc/CD button 3. MEM/READ. 4. MAX/AVG/MIN and setup upward. 5. Power ON/OFF and disable auto power off. 6. Real time auto zero. 7. DATA HOLD and Light source select (L.S.). 8. Setup downward. 9. Photo detector. EN-11

Relative Spectral (Sensitivity) The deviation from the comparative standards for luminosity is determined by JIS standard C 1609-1993. Peak sensitivity wavelength: 550 nm Typ. Ta=23 RELATIVE SENSITIVITY (%) WAVELENGTH (nm) CIE luminous spectral luminous EN-12

10. Attention Set for referring the testing of source of light is located at the right top end (0 degree) of the light sensor ball plane. When the meter is not in use, please keep the cap of the light sensor in its place to avoid the photo diode from wearing out. When it is not in use for a long time, please take the batteries away. And avoid keeping it in a place of high temperature and humidity. EN-13

11. Recommended Levels of Illumination Suitable levels of illuminance (According to the JIS standard Z 9110-1979) Offices Illuminance (lux) Place 1500 to 750 Offices, designing, drawing rooms 750 to 300 Offices, conference rooms, computer rooms 300 to 100 Workrooms, corridors, stairways, restrooms 75 to 30 Indoor emergency stairways Factories Illuminance (lux) Place 3000 to 1500 Where such work as assembling, inspecting testing, selecting, extremely precision visual work 1500 to 750 Assembling, inspecting, testing, selecting, precision visual work 750 to 300 Assembling, inspecting, testing, selecting and visual ordinary work 300 to 150 Wrapping and packing 75 to 30 Indoor emergency stairways EN-14

Schools Illuminance(lux) Place TM-201L/TM-209 1500 to 300 Precision drawing or drafting, precision experimenting, library 750 to 200 Classrooms, library reading rooms, staff rooms, gymnasia 300 to 75 Lecture halls, assembly rooms, locker rooms, corridors, stairways and restrooms 75 to 30 Warehouses and emergency stairways 10 to 2 School passages EN-15

12. Battery Replacement WARNING If the symbol appears on the LCD, please replace the battery immediately 1. Remove the battery cover 2. Replace the battery. 3. Install the battery cover. 13. END OF LIFE Caution: this symbol indicates that equipment and its accessories shall be subject to a separate collection and correct disposal EN-16

TENMARS ELECTRONICS CO., LTD 6F, 586, RUI GUANG ROAD, NEIHU, TAIPEI 114, TAIWAN. E-mail: service@tenmars.com http://www.tenmars.com EN-17