Improving the Collection Efficiency of Raman Scattering

Similar documents
Better Imaging with a Schmidt-Czerny-Turner Spectrograph

Improved Spectra with a Schmidt-Czerny-Turner Spectrograph

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

SpectraPro 2150 Monochromators and Spectrographs

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Minimizes reflection losses from UV-IR; Optional AR coatings & wedge windows are available.

Lever Your Genius. Spectrograph & Accessories Datasheet. FergieSpec.com

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

Oriel MS260i TM 1/4 m Imaging Spectrograph

BaySpec SuperGamut OEM

Chemistry 524--"Hour Exam"--Keiderling Mar. 19, pm SES

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

MS260i 1/4 M IMAGING SPECTROGRAPHS

Specifications. Offers the best spatial resolution for multi-stripe spectroscopy. Provides the user the choice of either high accuracy slit mechanism

Maya2000 Pro Spectrometer

Optional AR coating and wedge windows are available

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Advances in Hyperspectral Imaging Technologies for Multi-channel Fiber Sensing

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Compatible with Windows 8/7/XP, and Linux; Universal programming interfaces for easy custom programming.

Enhanced Chemical Identification Using High-Throughput Virtual-Slit Enabled Optical Spectroscopy and Hyperspectral Imaging

SPECTRAL SCANNER. Recycling

Microscope-Spectrometer

Add CLUE to your SEM. High-efficiency CL signal-collection. Designed for your SEM and application. Maintains original SEM functionality

100 khz and 2 MHz digitization rates Choose low speed digitization for low noise or high speed for fast spectral acquisition.

Back-illuminated scientific CMOS camera. Datasheet

Miniature Spectrometer Technical specifications

Microscopic Structures

High Speed Hyperspectral Chemical Imaging

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

TriVista. Universal Raman Solution

Fast Laser Raman Microscope RAMAN

HR2000+ Spectrometer. User-Configured for Flexibility. now with. Spectrometers

Observational Astronomy

Spark Spectral Sensor Offers Advantages

THE WASATCH ADVANTAGE

Instructions for the Experiment

Fast Laser Raman Microscope RAMAN

Minimizes reflection losses from UV to IR; No optical losses due to multiple optical surfaces; Optional AR coating and wedge windows available.

Section lll: SM Series Spectrometer. ometers SPECTRAL PRODUCTS

University of Wisconsin Chemistry 524 Spectroscopic Components *

DESIGN AND CHARACTERIZATION OF A HYPERSPECTRAL CAMERA FOR LOW LIGHT IMAGING WITH EXAMPLE RESULTS FROM FIELD AND LABORATORY APPLICATIONS

Preliminary Characterization Results: Fiber-Coupled, Multi-channel, Hyperspectral Spectrographs

The FTNIR Myths... Misinformation or Truth

metcon meteorologieconsultgmbh, Instruments for Atmospheric Research W1aa_Feb_2017_1.doc 1 -

Parameter Selection and Spectral Optimization Using the RamanStation 400

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Introduction to the operating principles of the HyperFine spectrometer

Fastest high definition Raman imaging. Fastest Laser Raman Microscope RAMAN

We bring quality to light. CAS 120 CCD Array Spectrometer

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

SOAR Integral Field Spectrograph (SIFS): Call for Science Verification Proposals

Section 1: SPECTRAL PRODUCTS

Chemical Imaging. Whiskbroom Imaging. Staring Imaging. Pushbroom Imaging. Whiskbroom. Staring. Pushbroom

UV/Optical/IR Astronomy Part 2: Spectroscopy

OCT Spectrometer Design Understanding roll-off to achieve the clearest images

Advanced Research Raman System Raman Spectroscopy Systems

Table of Content. Fiber-Coupled LED s Light-Guide-Coupled LED s LED Collimator Sources Low-cost LED Spot Lights...

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Application Note (A11)

Powerful DMD-based light sources with a high throughput virtual slit Arsen R. Hajian* a, Ed Gooding a, Thomas Gunn a, Steven Bradbury a

Superior ICP-OES optical design for unmatched speed and performance

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Supplementary Materials

Single-photon excitation of morphology dependent resonance

Supplementary Materials for

UltraGraph Optics Design

Material analysis by infrared mapping: A case study using a multilayer

WITec Alpha 300R Quick Operation Summary October 2018

ADAPTIVE CORRECTION FOR ACOUSTIC IMAGING IN DIFFICULT MATERIALS

True simultaneous ICP-OES for unmatched speed and performance

Noise Analysis of AHR Spectrometer Author: Andrew Xiang

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

Supplementary Figure S1. Schematic representation of different functionalities that could be

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

Report on BLP Spectroscopy Experiments Conducted on October 6, 2017: M. Nansteel

YOUR INSTRUMENT YOUR SOLUTION

The University of Toledo R. Ellingson and M. Heben

Experimental Analysis of Luminescence in Printed Materials

30 x 3.8 mm / 2000 x 256 pixel NIR Spectroscopy CCD. cooling. Specifications Summary. Active pixels 2000 x 256

PGS Family Plane Grating Spectrometer from ZEISS

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

CMOS Based Compact Spectrometer

Symmetrical Czerny-Turner, 75 mm focal length nm nm, depending on configuration (see table)

Horiba Jobin-Yvon LabRam Raman Confocal Microscope (GERB 120)

Section IX: AF Series Fibers and Fiber Couplers

Signal-to-Noise Ratio (SNR) discussion

Spectral signatures of surface materials in pig buildings

HAMAMATSU PHOTONICS K.K.

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

Mini-spectrometer from a DVD and folded paper

GPI INSTRUMENT PAGES

A Novel Multipass Optical System Oleg Matveev University of Florida, Department of Chemistry, Gainesville, Fl

Transcription:

PERFORMANCE Unparalleled signal-to-noise ratio with diffraction-limited spectral and imaging resolution Deep-cooled CCD with excelon sensor technology Aberration-free optical design for uniform high resolution across entire detector FLEXIBILITY Complete ecosystem of CUBE accessories for different measurement setups Ideal for Raman spectroscopy, photoluminescence imaging, fluorescence imaging, hyperspectral imaging, and microscopic imaging Pre-aligned optics and accessories minimize setup time CAPABILITIES IntelliCal for automated wavelength and intensity calibration Powerful LightField software for system control, data collection, and processing Frame-transfer and aberration-free technologies for fast, multiplexed data acquisition Improving the Collection Efficiency of Raman Scattering Why FERGIE? FERGIE is the latest aberrationfree spectrograph from Princeton Instruments. Outstanding performance makes it a perfect system for many different spectroscopy and imaging applications in research and industry. Introduction Laser Raman spectroscopy is a powerful technology that is successfully used in a variety of scientific research and industrial applications. The cross-section afforded by Raman scattering is typically orders of magnitude lower than that of other optical spectroscopic methods (such as infrared absorption, laser-induced fluorescence, and ultraviolet visible absorption), which in many cases serves to limit its utility. And while several innovative approaches (including surface-enhanced Raman spectroscopy, resonance Raman spectroscopy, and UV Raman spectroscopy) have been developed that effectively enhance the Raman scattering crosssection in order to improve sensitivity, these methods are not generally applicable to all chemicals and materials. In this note, we discuss the advantage of an aberration-free spectrograph design for performing Raman spectra measurements. FERGIE, a fully integrated spectrograph system from Princeton Instruments, was used for the demonstration. Since both coma and astigmatic aberrations are eliminated at all wavelengths by the FERGIE design, uniform diffraction-limited imaging and spectral resolution are achieved across the detector plane. This unique feature allows spectral binning over the entire detector so as to improve the signal-to-noise ratio of the data without losing any spectral resolution. In order to fully utilize the etendue (spread) of the system, a round-to-linear fiber bundle probe was employed for spectra collection. The light throughput provided by the bundle was observed to be significantly better than the throughput of a single-fiber setup. For more information, please visit http://www.fergiespec.com/. Although only a few chemicals were measured in this study, the experimental setup described herein is readily applicable to different materials. The setup can also easily be extended to allow hyperspectral imaging or spectral microscopic imaging measurements via the use of the FERGIE system s versatile CUBE accessories. 1

Experimental Setup A FERGIE integrated imaging spectrograph system (see Figure 1) with a built-in, back-illuminated CCD camera was used for all data collection reported. The 256 x 1024 photosensitive array of the detector (pixel pitch: 13 x 13 µm) was thermoelectrically cooled to -55 C for the study, which utilized a spectrograph focal length of 80 mm, a 600 g/mm grating, and a 785 nm wavelength-stabilized multimode laser coupled to a Raman probe through a 105 µm core fiber cable. Two distinct setups were used to couple the Raman scattering into the FERGIE spectrometer: (1) the first setup coupled the scattered light through a single 400 µm core fiber cable; (2) the second setup coupled the scattered light through a round-tolinear fiber bundle. The single-core fiber cable was connected to a Focusing CUBE, which focused the light on the slit of the spectrometer. A 100 µm slit was used for all single-fiber data collection. The fiber bundle, meanwhile, had 50 silica cores with a 50 µm core size. The linear end of the bundle was placed at the slit plane of the spectrometer and no physical slit was used for data collection with the fiber bundle. An atomic emission (AE) lamp and a quartz tungsten halogen (QTH) lamp from Princeton Instruments were also utilized to create some of the data and images presented in this note. a b c d Figure 1. Experimental setup: (a) overall system setup; (b) a FERGIE Sampling CUBE with Raman prove; (c) single-fiber coupling through a FERGIE Focusing CUBE; (d) fiber-bundle coupling. Chemical samples were obtained from commercial sources without any further purification. Results & Discussion Characterization of Diffraction-Limited Imaging Quality The FERGIE system s proprietary optical design eliminated aberrations (coma and astigmatism) at all wavelengths. Figure 2 shows the image of the linear end of the fiber bundle, with its 50 cores, which was placed at the slit entrance. The zoom-in image on the right shows tight spacing with a vertical length of 2.5 mm that slightly underfills the vertical dimension of the slit entrance. Each fiber is clearly distinguishable with a diameter of 3.85 pixels (50 µm). Figure 2. Images of the linear end of the fiber bundle with 50 fiber cores. 2

Figure 3 presents hyperspectral images of the fiber bundle using (a) a QTH lamp and (b) an AE lamp as light sources, respectively. The 600 g/mm grating provides spectral coverage of ~300 nm centered at 800 nm a b Figure 3. Spectral imaging of fiber bundle with (a) QTH lamp and (b) AE lamp. Inset in (b) shows an image taken with Czerny-Turner spectrograph for comparison. For comparison, an image of a slightly different fiber bundle that was previously collected using a Czerny-Turner (CT) spectrometer is shown as an inset of Figure 3(b). The Czerny-Turner design and its variations represent perhaps the most commonly employed optical design for grating-based spectrometers. This conventional, proven technology uses a minimal number of optics and provides sufficient performance for simple spectral data collection. The optimum performance of Czerny- Turner spectrometers, however, is only achievable at the center of the focal plane. Due to aberration effects, the image quality significantly degrades as one moves farther away from the center. By contrast, the proprietary aberration-free design of the FERGIE system eliminated all aberration effects. In Figure 3(a), each horizontal line corresponds to a QTH light spectrum from one fiber and diffraction-limited spatial resolution is maintained across the entire spectral range. In Figure 3(b), each vertical line corresponds to a discrete atomic emission line from the AE lamp and diffraction-limited spatial resolution is maintained both vertically (spatial axis) and horizontally (spectral axis). Figure 4 shows the spectrum of the AE lamp acquired by vertically binning the AE image that is presented in Figure 3(b). With a fiber bundle as the collection optics, the exposure time is 1 msec. 3

a b Figure 4. Vertically binned spectrum of AE lamp: (a) full spectrum plus (b) zoom-in region showing small emission peaks. The low read noise and low dark noise from the system s cooled CCD preserve wide dynamic range. Small emission lines can be measured, as shown in Figure 4(b), thanks to the FERGIE spectrograph system s high light throughput and deep-cooled CCD. Raman Measurements of Solid & Liquid Samples A 785 nm laser with maximum output of 475 mw was used for all Raman spectra measurements. The Raman spectra of graphite presented in Figure 5 were collected using either a fiber bundle or a single-core fiber to couple the Raman scattering into the FERGIE spectrometer. The fiber bundle delivered about a 3x signal improvement over the single fiber. The strong D band shown in Figure 5 indicates numerous defects in the graphite sample, while the asymmetric shape of the 2D band agrees with the sample s multilayer graphene structure. Similar signal improvement was seen when measuring a liquid (acetone) sample, as evidenced in Figure 6. The data collected with the fiber bundle is again about 3x stronger than the data collected with a single fiber. 4

Figure 5. Raman spectra of graphite Figure 6. Raman spectra of acetone. Conclusions In this note, we demonstrated the advantage of using an aberration-free spectrograph to measure Raman spectra. The experimental setup utilized is a preliminary attempt at leveraging the power of the FERGIE system to improve data quality. Such a high-performance system is particularly important for Raman measurements of samples like graphite or graphene materials, where the laser power needs to be carefully controlled so as to avoid sample damage. Uniform high resolution across the entire focal plane is also required in order to measure properties of graphene and graphite accurately, including the thickness of graphene structure and defects. Besides the spectroscopic measurement of materials, we expect the FERGIE spectrograph to be used for hyperspectral imaging and spectral microscopic imaging applications where an aberration-free system can provide unrivaled performance. 5