Submersible pressure sensor For superior applications Model LF-1

Similar documents
Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For water and wastewater Model LW-1

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

High-quality pressure transmitter For general industrial applications Model S-10

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Flush pressure transmitter For viscous and solids-containing media Model S-11

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-20

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

Float switch For industrial applications, plastic version Model RLS-2000

Electronic temperature switch with display Model TSD-30

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM pressure transmitter For mobile working machines Model MH-3

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Indicator for panel mounting Model

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Pressure transmitter For sanitary applications Model SA-11

Resistance thermometer Model TR30, compact design

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

Resistance thermometer Model TR30, compact design

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Resistance thermometer Model TR31, miniature design

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

HART field temperature transmitter Models TIF50, TIF52, TIF62

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Resistance thermometer Model TR30, compact design

Digital indicator for panel mounting With multi-function input Model DI25

Mechatronic pressure measurement. Applications. Special features. Description

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

High-precision process calibrator Model CED7000

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

DTM.OCS.S/N - Modbus Level Transmitter

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Technical Information Condumax CLS21D/CLS21

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

Isolators A3/1.

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

ED701 General Industry Pressure Transmitter

Condumax CLS21 and CLS21D

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Hand-held temperature calibrator Model CEP3000

In-Line Resistance Thermometers Model TR25

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Technical Information Condumax CLS15D/CLS15

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

Features. Picture. Specifications

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Condumax W CLS15 and CLS15D

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Ultrasonic level meters ULM 70

LST100 Ultrasonic level transmitter for upstream oil and gas

Isolating Repeater Input Series 9163

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Air flow meter For ventilation and air-conditioning Model A2G-25

Pressure and level transmitter PASCAL CV LEVEL,

Design and applications

Condumax CLS21 and CLS21D

Condumax CLS15 and CLS15D

Resistance Thermometers Model Series TR7X0, Sheathed Design

Ult r a s o n i c le v e l me t e r s ULM 55

Condumax CLS15 and CLS15D

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

SALES SERVICE +358 (0)

RMA42. Technical Information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transcription:

Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring Level measurement in rivers and lakes Deep well and groundwater monitoring Battery-operated level measuring systems Special features Suitable for measurements in contaminated and aggressive media An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a minimum maintenance effort Can be used in explosion-protected areas Developed for wireless applications Fig. left: Fig. right: With conduit and FEP cable With PUR cable Description Permanently reliable Extensive test cycles not only guarantee a permanent resistance and long service life in all commonly used oils and fuels, including aggressive crude oils and biofuels, but also in flowing and stagnant waters and in wastewater treatment applications. Thanks to newly developed special cables, components made of high-alloyed stainless steel and an optional overvoltage protection against lightning, the submersible pressure sensor is perfectly suited for the measurement of liquid levels, also in the outdoor area. Precise level and temperature measurement with HART communication A measurement uncertainty of max. 0.5 %, a long-term drift of 0.1 % and slight temperature errors make the LF-1 a reliable measurement solution for the monitoring of storage tanks and bodies of water. The additional analogue temperature output facilitates the compensation of a temperature-induced density error especially at temperatures of up to -40... +80 C [-40... +176 F]. The integrated HART communication can be used for scaling the measuring range and for the parameterisation of unit, error signal, and others. Optimised electronics for battery operation The modern electronic system guarantees not only a high accuracy in the long term but also ensures a very long battery life thanks to low power supply, low current consumption, fast response time and low-power output signals. Safety also in hazardous areas The optional intrinsically safe electronic system is authorised according to the common international standards and allows a safe worldwide application in explosive gases and vapours. WIKA data sheet LM 40.04 08/2018 Page 1 of 11 Data sheets showing similar products: Submersible pressure sensor, standard version; model LS-10; see data sheet PE 81.55 High-performance submersible pressure sensor; model LH-20; see data sheet PE 81.56

Measuring ranges Gauge pressure bar 0... 0.1 0... 0.16 0... 0.25 0... 0.4 0... 0.6 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 inwc 0... 50 0... 100 0... 150 0... 250 psi 0... 5 0... 10 0... 15 0... 25 0... 50 0... 100 mh 2 O 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 0... 16 0... 25 0... 40 0... 60 Absolute pressure bar 0... 1.6 0... 2.5 0... 4 0... 6 psi 0... 25 0... 50 0... 100 The given measuring ranges are also available in mbar, kpa and MPa. Overload safety 3 times Temperature measurement (option) Measuring ranges Option 1 Option 2-10... +50 C [14... 122 F] -40... +80 C [-40... +176 F] The temperature output signal corresponds to the selected medium temperature (see operating conditions). Output signals Without temperature measurement Standard Option 1 4... 20 ma (2-wire) 4... 20 ma + HART (2-wire) Option 2 DC 0.1... 2.5 V (3-wire, low power) 1) With temperature measurement Standard 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) Option 1 2 x DC 0.1... 2.5 V (3-wire, low power) 1) 1) Shortening the cable always results in a modification of the voltage signal (see accuracy specifications). Permissible load in Ω Current output: (U + -(U +min - 0.5 V)) / 0.023 A Voltage output: 1mA Additional load of the cable: cable length in m x 0.084 Ω [ cable length in ft x 0.0256 Ω] For voltage outputs, the load must be specified so that the output current does not exceed 1 ma. WIKA data sheet LM 40.04 08/2018 Page 2 of 11

Voltage supply The power supply depends on the selected output signal and the intrinsically safe electronics (Ex approval). When being operated in hazardous areas, the submersible pressure sensor must be powered via a repeater power supply (see accessories). Power supply Output signal Standard With Ex approval 4... 20 ma (2-wire) DC 8... 36 V DC 9... 30 V 4... 20 ma + HART (2-wire) DC 12... 36 V DC 12... 30 V DC 0.1... 2.5 V (3-wire, low power) DC 3.6... 36 V - 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) DC 8... 36 V DC 9... 30 V 2 x DC 0.1... 2.5 V (3-wire, low power) DC 3.6... 36 V - Low power is optimised for the battery operation. Current consumption Current output: Voltage output: max. 25 ma per output max. 5 ma Reference conditions (per IEC 61298-1) Temperature 15... 25 C [59... 77 F] Atmospheric pressure 860 1,060 mbar [86 106 kpa /12.5 15.4 psig] Air humidity 45... 75 % r. h. Power supply DC 24 V with current output DC 5 V with voltage output Mounting position Calibrated in vertical mounting position with process connection facing downwards. WIKA data sheet LM 40.04 08/2018 Page 3 of 11

Accuracy specifications Accuracy at reference conditions (pressure sensor) Accuracy 1) Non-linearity (per IEC 61298-2) BFSL Standard ±1 % of span ±0.5 % of span Option ±0.5 % of span ±0.25 % of span 1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). During the adjustment of the voltage signals, the cable length will be compensated. Every shortening of the cable at a later stage results in an offset error of approx. 0.14 % / 10 m [0.13 % / 30 ft]. Accuracy after turndown 5:1 via HART Standard Option ±1.25 % of scaled span ±0.75 % of scaled span By setting a turndown of greater than 5:1, a higher measuring deviation applies. Accuracy (temperature sensor) -10... +80 C [14... 176 F]: ±1.8 K -30... -10 C [-22... +14 F]: ±3.0 K -40... -30 C [-40... -22 F]: ±4.5 K Non-repeatability 0.1 % of span 0.2 % of span (with voltage output and cable length > 100 m [325 ft]) Long-term stability (per DIN 16086:2006-01) Measuring range > 0... 0.1 bar: ±0.1 % of span/year Measuring range 0... 0.1 bar: ±0.2 % of span/year Switch-on time Output signals without HART : Output signals with HART : 150 ms 250 ms Settling time Output signals without HART : Output signals with HART : 100 ms 250 ms WIKA data sheet LM 40.04 08/2018 Page 4 of 11

Overall error Including non-linearity, hysteresis, zero point and span error, temperature error and temperature hysteresis. Measuring range 0.6 bar, 250 inwc, 10 psi, 6 mh₂o Overall error (%) Accuracy Pressure sensor Temperature range ( C) Measuring range 0.4 bar, 150 inwc, 4 mh₂o Overall error (%) Accuracy Pressure sensor Temperature range ( C) Measuring range 0.25 bar, 100 inwc, 5 psi, 2.5 mh₂o Overall error (%) Accuracy Pressure sensor Temperature range ( C) WIKA data sheet LM 40.04 08/2018 Page 5 of 11

Measuring range 0.16 bar, 1.6 mh₂o Overall error (%) Accuracy Pressure sensor Temperature range ( C) Measuring range 0.1 bar, 50 inwc, 1 mh₂o Overall error (%) Accuracy Pressure sensor Temperature range ( C) WIKA data sheet LM 40.04 08/2018 Page 6 of 11

Operating conditions Ingress protection IP68 Increased overvoltage protection for lightning strikes (option) Nominal discharge current: 10 ka Rise time: 8/20 μs Immersion depth max. 100 m (325 ft) Max. tension force of the cable 1,000 N Weight Submersible pressure sensor: approx. 300 g [0.661 lbs] Cable: approx. 80 g/m [0.538 lbs / 10 ft] Additional weight: approx. 300 g [0.661 lbs] Permissible temperature ranges Medium Standard -10... +50 C [14... 122 F] Option -40... +80 C [-40... +176 F] Ambient Standard -40... +80 C [-40... +176 F] Storage Standard -30... +80 C [-22... +176 F] Explosion protection (option) Approval ATEX IECEx CSA FM Marking Zone 0 gas [II 1G Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [II 2G Ex ia IIC T4/T5/T6 Gb] Zone 0 gas [Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [Ex ia IIC T4/T5/T6 Gb] Class I, division 1, groups A, B, C, D Class I, zone 0; A/Ex ia IIC; T6... T4 Ga Class I, zone 1; A/Ex ia IIC; T6... T4 Gb Class I, zone 2; A/Ex ic IIC; T6... T4 Gc (see control drawing 14136138) Class I, division 1, groups A, B, C, D Class I, zone 0, AEx ia IIC, T6... T4 Ga Class I, zone 1, AEx ia IIC, T6... T4 Gb Class I, zone 2, AEx ic IIC, T6... T4 Gc (see control drawing 14136138) Permissible ambient temperature ranges in hazardous areas T4: -40... +80 C [-40... +176 F] T5: -40... +74 C [-40... +165 F] T6: -40... +59 C [-40... +138 F] WIKA data sheet LM 40.04 08/2018 Page 7 of 11

Materials (wetted) Standard Option (high-resistance) Case 316L 318LN Sensor element 316L Hastelloy C276 Cable PUR FEP Sealing FKM FKM Protection cap PVDF PVDF Electrical connection Cable outlet Standard Option Cable outlet without conduit Cable outlet with conduit Cable lengths Standard Metres (m) 3 5 10 15 20 25 30 40 50 Feet (ft) 10 20 30 40 50 75 100 125 150 Option Metres (m) For current output, freely definable up to 1,000 m Feet (ft) Other lengths on request Short-circuit resistance S+ vs. U- Reverse polarity protection U+ vs. U- Resistance to overvoltage DC 40 V For voltage output, freely definable up to 200 m For current output, freely definable up to 3,250 ft For voltage output, freely definable up to 650 ft Insulation voltage Standard: Increased overvoltage protection for lightning strikes: DC 850 V DC 50 V WIKA data sheet LM 40.04 08/2018 Page 8 of 11

Connection diagrams 4... 20 ma, 4... 20 ma + HART (2-wire) U+ brown (BN) U- blue (BU) Shield grey (GY) 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) U+ (pressure sensor) brown (BN) U- (pressure sensor) blue (BU) U+ (temperature sensor) green (GN) U- (temperature sensor) white (WH) Shield grey (GY) DC 0.1... 2.5 V (3-wire, low power) U+ brown (BN) U- blue (BU) S+ black (BK) Shield grey (GY) 2 x DC 0.1... 2.5 V (3-wire, low power) U+ brown (BN) U- blue (BU) S+ (pressure sensor) black (BK) S+ (temperature sensor) green (GN) Shield grey (GY) Legend U+ Positive power supply terminal U- Negative power supply terminal S+ analogue output Approvals (option) Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and immunity (industrial application) RoHS directive ATEX directive 1) - Ex i Zone 0 gas [II 1G Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [II 2G Ex ia IIC T4/T5/T6 Gb] European Union IECEx 1) Hazardous areas - Ex i Zone 0 gas [Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [Ex ia IIC T4/T5/T6 Gb] FM 1) Hazardous areas Class I, division 1, groups A, B, C, D Class I, zone 0, AEx ia IIC, T6... T4 Ga Class I, zone 1, AEx ia IIC, T6... T4 Gb Class I, zone 2, AEx ic IIC, T6... T4 Gc (see control drawing 14136138) CSA 1) Safety (e.g. electr. safety, overpressure,...) Hazardous areas Class I, division 1, groups A, B, C, D Class I, zone 0; A/Ex ia IIC; T6... T4 Ga Class I, zone 1; A/Ex ia IIC; T6... T4 Gb Class I, zone 2; A/Ex ic IIC; T6... T4 Gc (see control drawing 14136138) 1) Only available with output signals 4 20 ma, 2 x 4... 20 ma and 4 20 ma + HART. International USA USA and Canada Manufacturer s information and certificates China RoHS conformity SJ/T 11364-2014 Approvals and certificates, see website WIKA data sheet LM 40.04 08/2018 Page 9 of 11

Dimensions in mm [in] Cable outlet without conduit Cable outlet with conduit WIKA data sheet LM 40.04 08/2018 Page 10 of 11

Accessories Description Additional weight The additional weight increases the dead weight of the submersible pressure sensor. It simplifies the lowering in monitoring wells, narrow shafts and deep wells. It effectively reduces negative environmental influences of the measuring medium (e.g. turbulent flows) on the measuring result. Order number 14131008 Stainless steel 316L, approx. 300 g [0.661 lbs], length 115 mm [4.53 in] Cable strain relief clamp The cable strain relief clamp ensures easy and secure mechanical fastening of the submersible pressure sensor's cable. It serves to guide the cable to prevent mechanical damage and to reduce the action of tensile stresses. 14052336 Cable box The cable socket, with IP67 ingress protection and waterproof ventilation element, provides a moisture-free electrical termination for the submersible pressure sensor. It should be mounted in a dry environment, outside any shafts or vessels, or directly in the switch cabinet. Not suitable for hazardous areas! Intrinsically safe repeater power supply, model IS Barrier Input 0/4... 20 ma, supplying and non-supplying Bidirectional HART signal transmission 14052339 14117118 For details see data sheet AC 80.14 Indication and programming module HART DIH50 and DIH52 5-digit display, 20-segment bar graph, without separate power supply, with additional HART functionality. Automatic adjustment of measuring range and span. Secondary-master functionality: Setting the measuring range and unit of the connected transmitter using HART standard commands possible. Optionally explosion protection per ATEX. HART modem with USB, RS-232 or Bluetooth interface For scaling the measuring range using a PC via the HART protocol, a HART modem with USB, RS-232 or Bluetooth interface is available. The modem communicates with all registered HART field instruments and can be used with the most popular HART -compatible software programs. on request 7957522 (RS-232 interface) 11025166 (USB interface) 11364254 (Bluetooth interface) Ordering information Model / Measuring range / Output signal / Accuracy / Case material / Cable outlet / Cable material / Cable length / Overvoltage protection / Medium temperature / Approval / Accessories 12/2016 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. 08/2018 EN WIKA data sheet LM 40.04 08/2018 Page 11 of 11 WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de