Submersible pressure sensor For water and wastewater Model LW-1

Similar documents
Submersible pressure sensor For oils and fuels Model LF-1

Submersible pressure sensor For superior applications Model LF-1

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

High-quality pressure transmitter For general industrial applications Model S-10

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Flush pressure transmitter For viscous and solids-containing media Model S-11

Pressure transmitter For general industrial applications Model A-10

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

High-quality pressure transmitter For general industrial applications Model S-20

Electronic temperature switch with display Model TSD-30

Float switch For industrial applications, plastic version Model RLS-2000

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

OEM pressure transmitter For mobile working machines Model MH-3

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Indicator for panel mounting Model

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Ultra high purity transducer, Ex na nl Models WU-20, WU-25 and WU-26

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Resistance thermometer Model TR30, compact design

Analogue temperature transmitter Model T91.10, head mounting version DIN form B Model T91.20, head mounting version form J

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Model TR33, thread-mounted

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

Digital indicator for panel mounting With multi-function input Model DI25

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR31, miniature design

Pressure transmitter For sanitary applications Model SA-11

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Absolute pressure gauge with output signal For the process industry Models APGT and APGT43.160, NS 100 and 160

High-precision process calibrator Model CED7000

Resistance thermometer Model TR30, compact design

Process pressure transmitter Model IPT-10, standard version Model IPT-11, flush diaphragm

HART field temperature transmitter Models TIF50, TIF52, TIF62

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Mechatronic pressure measurement. Applications. Special features. Description

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Assembly 249 (9.80) 259 (10.2) Example: level probe with Pt100 and HUT temperature head transmitter ( ma) ma. Core colors: RD BK YE BU

Pressure transmitter for mobile hydraulic applications With output signals CANopen and J1939

PRODUCT CATALOGUE HYDROSTATIC PROBES SCREW-IN TRANSMITTERS

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Miniature resistance thermometer For sanitary applications Model TR21-B, for orbital welding

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version

Miniature resistance thermometer For sanitary applications, for orbital welding Model TR21-B

In-Line Resistance Thermometers Model TR25

Features. Picture. Specifications

DTM.OCS.S/N - Modbus Level Transmitter

Condumax CLS21 and CLS21D

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Isolators A3/1.

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Technical Information Condumax CLS21D/CLS21

Condumax W CLS15 and CLS15D

Hand-held temperature calibrator Model CEP3000

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

ED701 General Industry Pressure Transmitter

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Picture. Digital output signal (pressure and temperature) RS-485 Modbus RTU, 9600 bps Protocol details see Data Sheet SW

Technical Information Condumax CLS15D/CLS15

Condumax CLS15 and CLS15D

Pressure measurement. Process pressure/hydrostatic VEGAWELL 72. Product Information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Miniature resistance thermometer For sanitary applications Model TR21-C, with integrated sterile connection

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Air flow meter For ventilation and air-conditioning Model A2G-25

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Pressure and level transmitter PASCAL CV LEVEL,

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Gas-actuated combi-thermometer with Pt100 electrical output signal Model 76, stainless steel version

Isolating Repeater Input Series 9163

FOR CLEAN WATER AND SEWAGE WATER HYDROSTATIC LEVEL TRANSMITTERS

Ultrasonic level meters ULM 70

DPS 100 DPS 100. Gauge- / Differential- / Absolute Pressure Transmitter

Pressure measurement. Process pressure/hydrostatic VEGAWELL 52. Product Information

Design and applications

In-line resistance thermometer Model TR25

Analogue Temperature Transmitter

For clean water and sewage water NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

itemp PA TMT184 Technical information

Transcription:

Replacement product: Model LF-1 Level measurement Submersible pressure sensor For water and wastewater Model LW-1 WIKA data sheet LM 40.03 Applications Level measurement in rivers and lakes Deep well and groundwater monitoring Control of sewage lift and pumping stations Monitoring of sewage, settling and rainwater retention basins Special features Permanent use even in contaminated media An optimised discharge behaviour and a large pressure port prevent the instrument from clogging and ensure a minimum maintenance effort Explosion protection selectable in accordance with ATEX or IECEx Low-power output signals for battery-operated measuring systems available Optional temperature output for density compensation and temperature monitoring Submersible pressure sensor, model LW-1 Description Developed for water and wastewater The submersible pressure sensor model LW-1 has been developed especially for applications in the water management such as level measurement in fresh and salt water and in wastewater. The robust design and a large pressure port prevent it from clogging and minimise the application-specific maintenance, even in contaminated media. Thanks to newly developed special cables, components made of high-alloyed stainless steel and an optional overvoltage protection against lightning, the submersible pressure sensor is ideal for measurement applications in aqueous media. Temperature measurement and HART communication An analogue temperature output for monitoring of the medium temperature is optionally available. It facilitates the documentation of temperature characteristic curves and a compensation of temperature-induced density variations. The HART communication can be used for scaling the measuring range and for the parameterisation of unit, error signal, and others. Optimised electronics for battery operation The modern electronic system guarantees not only a high accuracy in the long term but also ensures a very long battery life thanks to low power supply, low current consumption, fast response time and low-power output signals. Safety also in hazardous areas The optional intrinsically safe electronic system is authorised according to the common international standards and allows a safe worldwide application in explosive gases and vapours. WIKA data sheet LM 40.03 12/2016 Page 1 of 10 Data sheets showing similar products: Submersible pressure sensor standard version; model LS-10; see data sheet PE 81.55 Submersible pressure sensor for oils and fuels; model LF-1; see data sheet LM 40.04

Measuring ranges Gauge pressure bar 0... 0.1 0... 0.16 0... 0.25 0... 0.4 0... 0.6 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 inwc 0... 50 0... 100 0... 150 0... 250 psi 0... 5 0... 10 0... 15 0... 25 0... 50 0... 100 mh 2 O 0... 1 0... 1.6 0... 2.5 0... 4 0... 6 0... 10 0...16 0... 25 0... 40 0... 60 The given measuring ranges are also available in mbar, kpa and MPa. Overload pressure limit 3 times Temperature measurement (option) -10... +50 C (14... 122 F) The temperature output signal corresponds to the selected medium temperature (see operating conditions). Output signals Without temperature measurement Standard Option 1 4... 20 ma (2-wire) 4... 20 ma + HART (2-wire) Option 2 DC 0.1... 2.5 V (3-wire, low power) 1) With temperature measurement Standard 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) Option 1 2 x DC 0.1... 2.5 V (3-wire, low power) 1) 1) Shortening the cable always results in a modification of the voltage signal (see accuracy specifications). Load Current output: (U + -(U +min - 0.5 V)) / 0.023 A Voltage output: 1mA Additional load of the cable: cable length in m x 0.084 Ω ( cable length in ft x 0,0256 Ω) For voltage outputs, the load must be specified so that the output current does not exceed 1 ma. Page 2 of 10 WIKA data sheet LM 40.03 12/2016

Voltage supply The power supply depends on the selected output signal and the intrinsically safe electronics (Ex approval). When being operated in hazardous areas, the submersible pressure sensor must be powered via an isolated barrier (see accessories). Power supply Output signal Standard With Ex approval 4... 20 ma (2-wire) DC 8... 36 V DC 9... 30 V 4... 20 ma + HART (2-wire) DC 12... 36 V DC 12... 30 V DC 0.1... 2.5 V (3-wire, low power) DC 3.6... 36 V - 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) DC 8... 36 V DC 9... 30 V 2 x DC 0.1... 2.5 V (3-wire, low power) DC 3.6... 36 V - Low power is optimised for the battery operation. Current consumption Current output: max. 25 ma per output Voltage output: max. 5 ma Reference conditions (per IEC 61298-1) Temperature 15... 25 C (59... 77 F) Atmospheric pressure 860 1,060 mbar (86 106 kpa /12.5 15.4 psig) Humidity 45... 75 % r. h. Power supply DC 24 V with current output DC 5 V with voltage output Mounting position Calibrated in vertical mounting position with process connection facing downwards. WIKA data sheet LM 40.03 12/2016 Page 3 of 10

Accuracy specifications Accuracy at reference conditions (pressure sensor) Accuracy 1) Non-linearity (per IEC 61298-2) BFSL Standard ±1 % of span ± 0.5 % of span Option ±0.5 % of span ±0.25 % of span 1) Including non-linearity, hysteresis, zero offset and end value deviation (corresponds to measured error per IEC 61298-2). During the adjustment of the voltage signals, the cable length will be compensated. Every shortening of the cable at a later stage results in an offset error of approx. 0.14 % / 10 m (0.13 % / 30 ft). Accuracy after turndown 5:1 via HART Standard Option ±1.25 % of scaled span ±0.75 % of scaled span By setting a turndown of greater than 5:1, a higher measured error applies. Accuracy (temperature sensor) ±1.8 K Non-repeatability 0.1 % of span 0.2 % of span (with voltage output and cable length > 100 m (325 ft)) Long-term stability (per DIN 16086:2006-01) Measuring range > 0... 0.1 bar: ±0.1 % of span/year Measuring range 0... 0.1 bar: ±0.2 % of span/year Switch-on time Output signals without HART : 150 ms Output signals with HART : 250 ms Settling time Output signals without HART : 100 ms Output signals with HART : 250 ms Page 4 of 10 WIKA data sheet LM 40.03 12/2016

Total error band The total error band includes the non-linearity, hysteresis, zero point and span error, temperature error and temperature hysteresis. Measuring range 0.6 bar, 250 inwc, 10 psi, 6 mh₂o Total error (%) Accuracy pressure sensor Temperature range ( C) Measuring range 0.4 bar, 150 inwc, 4 mh₂o Total error (%) Accuracy pressure sensor Temperature range ( C) Measuring range 0.25 bar, 100 inwc, 5 psi, 2.5 mh₂o Total error (%) Accuracy pressure sensor Temperature range ( C) WIKA data sheet LM 40.03 12/2016 Page 5 of 10

Measuring range 0.16 bar, 1.6 mh₂o Total error (%) Accuracy pressure sensor Temperature range ( C) Measuring range 0.1 bar, 50 inwc, 1 mh₂o Total error (%) Accuracy pressure sensor Temperature range ( C) Page 6 of 10 WIKA data sheet LM 40.03 12/2016

Operating conditions Ingress protection IP68 Increased overvoltage protection for lightning strikes (option) Nominal discharge current: 10 ka Rise time: 8/20 μs Immersion depth max. 100 m (325 ft) Max. tensile force of the cable 1,000 N Weight Submersible pressure sensor: Cable: Additional weight: approx. 300 g (0.661 lbs) approx. 80 g/m (0.538 lbs/10 ft) approx. 300 g (0.661 lbs) Permissible temperature ranges Medium: -10... +50 C (14... 122 F) Ambient: -40... +80 C (-40... +176 F) Storage: -30... +80 C (-22... +176 F) Explosion protection (option) Approval ATEX IECEx Marking Zone 0 gas [II 1G Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [II 2G Ex ia IIC T4/T5/T6 Gb] Zone 0 gas [Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [Ex ia IIC T4/T5/T6 Gb] Permissible ambient temperature ranges in hazardous areas T4: -40... +80 C (-40... +176 F) T5: -40... +74 C (-40... +165 F) T6: -40... +59 C (-40... +138 F) Materials (wetted) Standard Option (high-resistance) Case 316L 318LN Sensor element 316L Hastelloy C276 Cable PUR FEP Sealing FKM FKM Protection cap PVDF PVDF WIKA data sheet LM 40.03 12/2016 Page 7 of 10

Electrical connection Cable outlet Standard Option Cable outlet without conduit Cable outlet with conduit Cable lengths Standard Metre (m) 3 5 10 15 20 25 30 40 50 Feet (ft) 10 20 30 40 50 75 100 125 150 Option Metre (m) For current output, freely definable up to 1,000 m For voltage output, freely definable up to 200 m Feet (ft) For current output, freely definable up to 3,250 ft For voltage output, freely definable up to 650 ft Other lengths on request Short-circuit resistance S+ vs. U- Reverse polarity protection U+ vs. U- Resistance to overvoltage DC 40 V Insulation voltage Standard: DC 850 V Increased overvoltage protection for lightning strikes: DC 50 V Connection diagrams 4... 20 ma, 4... 20 ma + HART (2-wire) U+ brown (BN) U- blue (BU) DC 0.1... 2.5 V (3-wire, low power) U+ brown (BN) U- blue (BU) Shield grey (GY) S+ black (BK) Shield grey (GY) 2 x 4... 20 ma (2 x 2-wire, galvanically isolated) U+ (pressure sensor) brown (BN) U- (pressure sensor) blue (BU) U+ (temperature sensor) green (GN) U- (temperature sensor) white (WH) 2 x DC 0.1... 2.5 V (3-wire, low power) U+ brown (BN) U- blue (BU) S+ (pressure sensor) black (BK) S+ (temperature sensor) green (GN) Shield grey (GY) Shield grey (GY) Legend U+ positive power supply terminal U- negative power supply terminal S+ analogue output Page 8 of 10 WIKA data sheet LM 40.03 12/2016

Approvals (option) Logo Description Country EU declaration of conformity EMC directive EN 61326 emission (group 1, class B) and interference immunity (industrial application) RoHS directive ATEX directive 1) European union Ex i Zone 0 gas [II 1G Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [II 2G Ex ia IIC T4/T5/T6 Gb] IECEx 1) Hazardous areas Ex i Zone 0 gas [Ex ia IIC T4/T5/T6 Ga] Zone 1 gas [Ex ia IIC T4/T5/T6 Gb] International 1) Only available with output signals 4 20 ma and 4 20 ma + HART. Manufacturer s information and certificates China RoHS conformity SJ/T 11364-2014 Approvals and certificates, see website Dimensions in mm [in] Cable outlet without conduit Cable outlet with conduit WIKA data sheet LM 40.03 12/2016 Page 9 of 10

Accessories Description Additional weight The additional weight increases the dead weight of the submersible pressure sensor. It simplifies the lowering in monitoring wells, narrow shafts and deep wells. It effectively reduces negative environmental influences of the measuring medium (e.g. turbulent flows) on the measuring result. Order number 14131008 Stainless steel 316L, approx. 300 g (0.661 lbs), length 115 mm (4.53 in) Cable strain relief clamp The cable strain relief clamp ensures easy and secure mechanical fastening of the submersible pressure sensor's cable. It serves to guide the cable to prevent mechanical damage and to reduce the action of tensile stresses. 14052336 Cable box The terminal box, with IP67 ingress protection and waterproof ventilation element, provides a moisture-free electrical termination for the submersible pressure sensor. It should be mounted in a dry environment, outside any shafts or vessels, or directly in the switch cabinet. Not suitable for hazardous areas! Intrinsically safe repeater power supply, model IS Barrier Input 0/4... 20 ma, supplying and non-supplying Bidirectional HART signal transmission 14052339 14117118 For details see data sheet AC 80.14 Indication and programming module HART DIH50 and DIH52 5-digit display, 20-segment bar graph, without separate power supply, with additional HART functionality. Automatic adjustment of measuring range and span. Secondary-master functionality: Setting the measuring range and unit of the connected transmitter using HART standard commands possible. Optionally explosion protection per ATEX. HART modem with USB, RS-232 or Bluetooth interface For scaling the measuring range using a PC via the HART protocol, a HART modem with USB, RS-232 or Bluetooth interface is available. The modem communicates with all registered HART field instruments and can be used with the most popular HART -compatible software programs. on request 7957522 (RS-232 interface) 11025166 (USB interface) 11364254 (Bluetooth interface) Ordering information Model / Measuring range / Output signal / Accuracy / Case material / Cable outlet / Cable material / Cable length / Overvoltage protection / Approval / Accessories 12/2016 WIKA Alexander Wiegand SE & Co. KG, all rights reserved. The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. Page 10 of 10 WIKA data sheet LM 40.03 12/2016 12/2016 EN WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Straße 30 63911 Klingenberg/Germany Tel. +49 9372 132-0 Fax +49 9372 132-406 info@wika.de www.wika.de