VBC-16VFP QUICK START GUIDE

Similar documents
Installation, Operation and Maintenance Instructions

VibroBlock Systems, Some Basic Concepts And the VBC 2000/2500

Type: FR16 S. Montagetechnik. Frequency Converter for Vibratory Feeders. Operating Instructions

REOVIB. Control units for vibratory feeder engineering ELEKTRONIK REOVIB MFS 168. Range of frequency controllers for vibratory feeders

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

Service Instructions. The Conductor Controls. Conductor DC15-A, Enclosed Unit CH15-A, Open Chasis Unit

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

MicroManager. Velocity Mode PID Dancer/Loadcell Control. Instruction Manual MM3000-PID

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

USER MANUAL. EPP Intelligent Positioner Control Unit 1/22.

Controllers for Vibratory Feeder Engineering REOVIB MTS 440/442. REO-USA, Inc. Thyristor controllers for vibratory feeders With digital settings

OVEN INDUSTRIES, INC. Model 5C7-362

Before you operate the inverter, the parameters that you must first program are the basic parameters.

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

USER MANUAL SAFESCAN 2210 / 2250 BANKNOTE COUNTER. 1

REOVIB. Control units for flexible automation

Variable Speed Brushed DC Motor Drive

AMERITRON SDC-102 Screwdriver Antenna Controller

MFJ ENTERPRISES, INC.

Instruction Notes for 108A L Sensor Input

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

ADJUST AND SET UP FOR UNIT B

Pic-Convert Board Instructions

P o w e r. C O N T R O L S A N D a t h e n a c o n t r o l s. c o m. ATHENA CONTROLS, INC Campus Drive Plymouth Meeting, PA U.S.A.

Compact and Multifunction Controller for Parts Feeder

HPVFP High Performance Full Function Vector Frequency Inverter

Installation, Operation and Maintenance Instructions

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Experiment P20: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

RODIX INCORPORATED TOLL FREE (800) , FAX (815) rodix.com

Generator Speed Controller Model GSC 1

NX Series Inverters. HVAC Pocket Programming Guide

Rev.8 03/08 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2008 NUWAVE TECHNOLOGIES, INC.

MicroManager. Torque Mode CTCW/Loadcell Control. Instruction Manual MM3000-CTCW

DLVP A OPERATOR S MANUAL

Operation and Installation Manual

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

Micropulse position measuring Micropulse

Coils & Electronic Controls

Certification Test CT.Sigma7.01.eLV.Tuning.CertificationTest

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 7.X August 2015 USER MANUAL. metaphase-tech.com. pg. 1

Introduction To Temperature Controllers

MTY (81)

April 1994 UCM-420A. Setpoint Controller. Operating and Installation Instructions

DUKANE. Frequency Tracking in iq Systems APPLICATION NOTE AN513. Intelligent Assembly Solutions

T5x Error Codes DGC5X Console Board W/ ACD3X LCB

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

OCCUPANCY SENSOR REMOTE USER GUIDE

FC Series Signal Conditioners

Metaphase ULC-2. Technologies ULC. Metaphase. Technologies Version 6.2 June 12, 2013 USER MANUAL. metaphase-tech.com. pg. 1

MFJ ENTERPRISES, INC.

TECHNICAL DATASHEET #TD1400AX PWM Controlled Solenoid Driver (DIN rail mount) P/N: PWMC-DR-2A, PWMC-DR-1.2A

Frequency Controller SIGA (V6) Translation of operating and installation instructions

Activity P40: Driven Harmonic Motion - Mass on a Spring (Force Sensor, Motion Sensor, Power Amplifier)

DigiSpeed DC-03. Isolated Control Voltage Generator User s Guide. PCB: DC-03 V3.0 Firmware: Ver: 3.0 Mach3: Ver: 1.84

REOVIB Control Equipment for the Vibratory Feeder Industry MFS 268. Frequency Converter for Vibratory Feeders

PROCESS & TEMPERATURE CONTROLLERS

HP 33120A Function Generator / Arbitrary Waveform Generator

Configuration Example of Temperature Control

Milliamp Calibrator. Model 434. General description. Calibrate with laboratory accuracy. All 4 to 20 ma loop functions

LASER. Analog Laser Displacement Transducer. LAM Series. Key-Features: Content:

Continental Hydraulics Installation Manual CEM-PA-A

TECHNICAL PRODUCT DATASHEET

YGE ProgCard II - Programming Card

Section 11 Electronic Position Controls & Encoders

The Perception. Is Reality. Test Bench

LLS - Introduction to Equipment

QL50 Luminescence Sensor

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

High Performance Process & Temperature Controllers

Autonomous Robot Control Circuit

F4-04DA-1 4-Channel Analog Current Output

IT6810/IT6811/IT6812 IMPACT TRANSMITTER Installation Manual

Automation Devices, Inc West Ridge Road, Fairview, PA AUTODEV.COM

US18-PL-5-N03 Ultrasonic Sensors

F4 08DA 2 8-Channel Analog Voltage Output

RODIX INCORPORATED TOLL FREE (800) , FAX (815) rodix.com

Vehicle Data Display and Logger Installation and Operation Manual Rev Focus Applied Technologies

FREQUENCY AGILE FM MODULATOR INSTRUCTION BOOK IB

Analog Servo Drive 25A20DD

with Light Level, Isolated Relay and Manual On features

STEPPING MOTOR EMULATION

ISOMETER IRDH575. Approvals

This Errata Sheet contains corrections or changes made after the publication of this manual.

GS1 Parameter Summary Detailed Parameter Listings...4 9

RODIX INCORPORATED TOLL FREE (800) , FAX (815) rodix.com

DigiSpeed-GX DC-03. Isolated Control Voltage Generator User s Guide. DigiSpeed-GX PCB Ver:2.0 Firmware Ver: 1.0 Mach3 Ver: 1.84

Operating Instructions. for. Controller SMS 150 / 151

Fuzzy Temperature Controllers E5AF

AMANO PIX-21. Electronic Time Recorder. Operation Manual

Installation and Operating Instructions. Power IT Power Factor Controller RVC

F2-04AD-1, F2-04AD-1L 4-Channel Analog Current Input

Virtual Lab 1: Introduction to Instrumentation

SRVODRV REV7 INSTALLATION NOTES

RODIX INCORPORATED rd Ave., ROCKFORD IL TOLL FREE (800) , FAX (815)

S11 Adjustable Speed Drive Engineering Specification

Transcription:

The Arthur G. Russell Co., Inc 750 Clark Ave. P.O. Box 237 Bristol CT, 06011-0237 Phone: 860-583-4109 Fax: 860-583-0686 www.arthurgrussell.com agr@arthurgrussell.com 1 rev3 6/21/10

TABLE OF CONTENTS QUICK START OVERVIEW... 3 NAVIGATION... 3 (STEP 1) RECALL FACTORY SETTINGS... 3 (STEP 2) CONFIGURE THE SERVICE MENU ITEMS... 4 (STEP 3) ENABLE TO RUN... 5 (STEP 4) AUTO TUNE... 5 (STEP 5A) NON-ANALOG APPLICATIONS:... 6 (STEP 5B) ANALOG CONTROL APPLICATIONS:... 6 NOTES... 7 (STEP 6) USING TWO SETPOINTS:... 7 USER GUIDELINES OVERVIEW... 9 TUNING NOT NECESSARY... 9 SPECIAL CONSIDERATIONS WITH VARIABLE FREQUENCY... 9 SPECIAL APPLICATIONS... 10 2 rev3 6/21/10

QUICK START OVERVIEW This Quick Start Guide is not intended to replace the full Operating Instructions manual. It is intended to be used in conjunction with the manual. The Quick Start Guide contains important initial setup parameters as well as the most common parameters used to get started setting up a VibroBlock feed system. There are many other features available in the VBC-16VFP that are not covered here. Please refer to the Operating Instruction manual for all available features. With this guide, you will find it quick and easy to get a VBC-16VFP up and running. Follow the steps (1)-(6) for setting up a new system. NAVIGATION Press the P button until you reach a display that starts with C followed by 3 digits such as C000. Press the c d buttons to select the desired parameter number. Press the P button to select the parameter selection you would like to change. Press the c d buttons to change your selections value. Always press P to save before moving to the next step. (You may step backwards at any time by using the F button). The 1 and 0 buttons will start and stop vibration if the control is enabled. Follow these navigation instructions for all the following steps. (STEP 1) RECALL FACTORY SETTINGS When powering up a VBC-16VFP controller for the first time, it is recommended that you RECALL FACTORY SETTINGS. A New control should already have these settings, but performing this step ensures that no parameters have been changed since the control was manufactured. Perform the following steps: Use the up/down buttons to get to C210 (RECALL FACTORY SETTINGS) 1. Press the P button. 2. At the FAC display, press the c button and the controller will flash SAFE on the screen. This step resets the controller back to factory defaults, so that any incorrect settings are cleared. 3. Press the P button until you see C210. 3 rev3 6/21/10

(STEP 2) CONFIGURE THE SERVICE MENU ITEMS 1. In order to use all the parameters of the Service Menu, Service Mode must be enabled. Go to C127, and select En.S. Change it to EN.S1. You can now access all the Service Menu parameters. We can now proceed to the Service Menu: C. 040. Change only parameters: I.xxx.x, F.L.xx, F.H.xx and P.L.xxx. 2. The first parameter we will change is current limit. It is displayed as I. 100.0. 100.0 equals 100% output of the controller which is 16 amps. It is important that this parameter be set for the number of VibroBlocks that are connected to the controller times the current rating of the VibroBlock. An example might be: A 30 inch driver with 6 VB-32 VibroBlocks. 6X2 amps per block equals 12 amps. The parameter is set to: I. 075.0. The formula is: (Total VibroBlock amps) /16 X 100. For the above example: (12 amps) / 16 X 100 = 75%. Proper setting of this parameter will prevent burning out of the VibroBlock coils. 3. The next 2 parameters we will change are the low frequency limit and high frequency limit. These parameters limit the frequency range of the controller output as well as the range of the automatic frequency search. Since VibroBlock feeder frequencies change very little over time, it is advisable to set these limits close. Plus and minus 20% is usually a good range. For a feeder tuned at 60Hz, the range would be: F.L. 48 and F.H. 72. 4. The last parameter is Output Voltage Limit. Leave it at the factory default value of: P.L.100 when operating the control from supply voltages of: 100-125 volts. When operating the control from supply voltages above 125 volts, set P.L. using this formula: 120 / (supply voltage) X 100. Example for 208 volts: 120 / 208 X 100 = 57.69. Round up to 58.This is very important because it limits the output voltage to the VibroBlocks to 120 volts and could prevent possible damage from high voltage. 5. When you are done with the steps above, go to C127 and change En.S 1 back to En.S 0. This will prevent someone from accidentally changing any of these important parameters. 4 rev3 6/21/10

(STEP 3) ENABLE TO RUN In order to perform the next step: Auto Tune, the control must be enabled to run. If the enable input is wired to a PLC, it may be possible to turn on the enable input. If not, the following steps will need to be performed in order for the system to run. You will be inverting the enable input, which will allow the system to run when the enable input is off. This is the En.x parameter, found in C003. Use the up/down arrow keys until you see C 003. Press the P key until you come to the En.x parameter. Use the c d keys to set En.1. (The enable input is now inverted). (STEP 4) AUTO TUNE Use the c dbuttons to get to C008. Press the P button to get into the C008 parameter lists. 1. Set the A (amplitude) parameter to 20% as starting point, using the c d keys. 2. Press the P button to go to the next parameter. 3. Set the P (power) parameter to 20% to start, using the c d keys. 4. Press the P button to go to the next parameter. 5. Do not change the F (frequency) parameter. This will be set during auto-tune. Press the P button to skip the F parameter. 6. Change the ACC parameter from 0 to 1 using the c d keys. This enables the transducer. 7. Press the P button to go to the next parameter. 8. The PA parameter is the gain setting. Lowering the number will reduce oscillations in output. Leave the setting at default for autotune. 9. Press the P button to go to the next parameter. 10. The IA parameter is the acceleration setting. Start with 20% for tuning. A HIGHER number will lessen the rapping on vibration start. 11. Press the P button to go to the next parameter. 12. When at the AFC parameter, use the c d buttons to change the 0 to a 1. This will turn on automatic frequency control. 13. Press the P button to go to the next parameter. 14. When at the AFS parameter, press c or d button to start auto-tuning. Auto-Tuning Completed Auto-Tuning is complete when the display stops flashing. Set I.A to approximately 50-80% to lessen any rapping on vibration start. Proceed to step 5A or 5B. 5 rev3 6/21/10

PERFORM (STEP 5A) or (STEP 5B) Note: The A parameter is the parameter that the operator would normally change in order to adjust amplitude. The P parameter is used as a high limit to protect the equipment from damage from overly high amplitude. It should be set slightly higher than the highest amplitude that is needed with A at 100. P and other setup parameters can be hidden if desired after setup is complete. (See Operator Manual 10.2.10) (STEP 5A) NON-ANALOG APPLICATIONS: Set the A amplitude parameter to 100%. Adjust the P power setting upwards until the vibration level is optimum, and then increase the P setting slightly more than needed. This should be set to no more than the maximum safe vibration amplitude. Adjust A for the desired running amplitude. (STEP 5B) ANALOG CONTROL APPLICATIONS: Amplitude/Power Parameters Set-Up - Set the analog input to 100%, with the P power setting at some lower value (maybe 50% to start). Adjust the P power setting upwards until the vibration level is optimum, and then increase the P setting slightly more than needed. This should be set to no more than the maximum safe vibration amplitude Lower the analog input A (amplitude) until vibration is back at optimal. You can now use the full range of the analog input from zero to 100% without any danger of damaging the equipment. 6 rev3 6/21/10

NOTES To use analog control, make sure that the A parameter amplitude setting is set to 0. At start of tuning, make sure that the enable C003, (-EN.x) is set to 1. Return the enable to (-En.0) for normal operation from an external enable. If the VBC-16VFP is used with analog control, set these C003 parameters accordingly: 1. ESP.1 = External set point 2. ESP.0 = Internal set point 3. 420 0 = 0-10Vdc analog input 4. 420 1 = 4-20ma analog input 5. POT.0 = Use analog input 6. POT.1 = Use keypad/potentiometer (STEP 6) USING TWO SETPOINTS: It is possible to program two different internal set points and switch between them using digital wiring signals. This is useful if a controlled item might need to slow down in the event of a high level. To use two set points, wire the primary enable signal to terminal #5 (terminal #4 is DC common). Wire a second enable input to terminal #2. Logic operation for these signals is as follows: Enable #1 ON = Set point #1 (normal) activates. Enable #1 AND #2 ON = Set point #2 activates. To activate the programming for two set points Use the c dbuttons to get to C003. Press the P button to get into the C003 parameter lists. Set these C003 parameters accordingly: 1. SP.2.0 = Level sensor control 2. SP.2.1 = 2 nd Set Point Active 3. S2.d.0 = Level sensor control 4. S2.d.1 = Time delayed changeover to 2 nd set point. Set these C002 parameters accordingly: 1. A. = 1 st Set point amplitude 2. = 2 nd Set point amplitude 7 rev3 6/21/10

PARAMETER REFERENCE (From Operator Manual) Parameter: Code Factory setting: Entry Code: Vibratory feeder Amplitude (throughput) 0...100 % A. 0 % 000, 002 The following variable parameters are available for setting up the feed system Parameter: Display Factory setting: Entry Code: Vibratory feeder Amplitude (throughput)) 0...100 % A. 0 % 000, 002, 020, 096 Maximum control limit (U max ) 5...100 % P. 90 % 008, 020, 096 Vibrating frequency 30...140 Hz (5...300 Hz) F. 100 Hz 008, 020 040, 096, Soft start ramp up 0...60 Sec. /. 0.1 Sec. 020, 096 Soft stop ramp down 0...60 Sec. \. 0.1 Sec. 020, 096 Switch to external set point 0 / I E.S.P. 0 003 Set point 0(4)...20 ma 0 / I 4.20 0 003 Potentiometer set point 0 / I POT. 0 003 Coarse / Fine control 0 / I S.P.2. 0 003 Invert enable 0 / I -En. 0 003 Pulse feed 0 / I HOP. 0 064 On time delay (only if HOP. = I) 0 60 Sec. H. 1.0 Sec. 064 Off time delay (only if HOP. = I) 0 60 Sec. h 1.0 Sec. 064 Invert hopper sensor (not active) 0 / I -Ho. 0 064 Regulation (with sensor) Switch to regulation 0 / I ACC. 0 008 P characteristic 0...100 P.A. 40 008 I characteristic 0...100 I.A. 100 008 Automatic frequency control 0 / I A.F.C 0 008 Start automatic frequency search A.F.S. 008 Track control Switch on time delay 0...60 Sec. I. 1.0 Sec. 007, 167 Switch off time delay 0...60 Sec. O. 1.0 Sec. 007, 167 Invert sensor PNP / PNP -SE. PNP 007, 167 invert Sensor Time-out 0 / I E.En. 0 015, 167 Sense time delay (Sensor Time-out) 1...240 Sec. E. 180 015, 167 Not Used A.i. 4 015 Service Display actual output current i. 040 Display actual frequency F. 040 Save user settings PUSH. 143 Recall factory settings FAC. 210 Recall user settings US.PA. 210 Hide programming menus 0 / I Hd.C. 0 117 Hide set point adjustment 0 / I di.s. 0 137 Display software version 001 8 rev3 6/21/10

USER GUIDELINES USER GUIDELINES OVERVIEW The VBC-16 VFP is a variable frequency controller designed to operate Arthur G. Russell Co. VibroBlock feeder systems. It is our next generation of controllers, and is intended to be used in place of the VBC-2000, or earlier controllers such as the VBC-73S. It is capable of providing the same features as the VBC-2000 with one important addition: The ability of operating VibroBlock feeder systems at different frequencies than what are available from the power line, such as 60hz or 50hz. This document will explain some ways of taking maximum advantage of this feature. TUNING NOT NECESSARY When setting up a new VibroBlock system such as a feeder, track or bin, we no longer have to tune it to a particular frequency. For most applications you will need to calculate the SRU s for 60hz as shown in the VibroBlock Feeder Instruction Manual. No further tuning is required. No weights will be generally necessary on tracks and bins. The only weights that will be required will be on feeder bowls, and only enough to achieve proper balance. Balance a bowl, using the Arthur G. Russell bowl balancing device as described in the VibroBlock Feeder Instruction Manual. The only reason to start off with a frequency of 60hz is that we have the most experience with 60hz and are familiar with the way parts feed at this frequency. The VBC-16 VFP can autosearch and find the resonant frequency of a VibroBlock system. That frequency is saved and used as a starting point when the feeder, track or bin is run. The controller will make automatic adjustments as tuning changes over time. This eliminates periodic maintenance for the purpose of re-tuning. SPECIAL CONSIDERATIONS WITH VARIABLE FREQUENCY When operating a feeder and a track together, it is important to pay close attention to the gap between the two. They will never stay in sync as they vibrate as they do with conventional controllers. A larger gap will be necessary to prevent the two from hitting each other. In some cases an overlapping transfer may be required when feeding small parts. Proper isolation of mass bars is more important when using variable frequency controllers. Two vibratory devices operating on the same machine will create a third frequency that is equal to the difference between the two. As an example, a feeder operating at 60hz and a track operating at 61hz will produce a once per second vibration that can be felt and heard traveling through the machine. More than 2 controllers will create multiple frequencies as they interact with one another. These frequencies are often referred to as harmonics. In some cases harmonics can actually be seen in a vibratory device that appears to be pulsating or not running smoothly. Often building 9 rev3 6/21/10

lighting provided by fluorescent or HID lighting causes this. This type of lighting will act like a strobe light at building line frequency such as 60hz or 50hz. This will appear as a pulsation that moves at the difference between building frequency and vibratory frequency. It is most visible on the amplitude sticker. If you suspect that you have a problem, shine a flashlight at the sticker while shielding it from building lighting. If the pulsation goes away, it was just an optical illusion caused by the strobe effect. If it remains, gain adjustment or service may be required. Harmonics can also be produced in a feed system in other ways, such as: Loose mounting screws on a bowl or track. Tooling that is not rigid or securely fastened. Loose tuning weights or any other loose components. Harmonics can be particularly troublesome when performing an Automatic Frequency Search with the VBC-16 VFP. Automatic Frequency Search should never be performed with any product in the feed system. It also should not be done on a bowl until after the bowl has been balanced. It should be repeated after any addition or removal of tooling. The Automatic Frequency Search outputs it s full range of frequencies in order to find the resonant frequency. This can take several minutes and sometimes needs to be repeated. Follow the directions in the VBC-16 VFP manual or our Quick Start Guide. SPECIAL APPLICATIONS Another major advantage of variable frequency is the ability to operate at frequencies other than the ones available from the power line. This can be very helpful in solving difficult feeding problems. The first special application we will discuss is: Tuning to a higher frequency. If you have a feed system that is having trouble making rate, you may need to try a higher than line frequency. Higher frequencies can be helpful when feeding small or light parts. All that is required to raise the frequency is to add springs to the VibroBlocks, followed by an Automatic Frequency Search. Springs can be added up to the limit allowed, although only enough should be added to do the job. Higher frequencies will cause more audible noise and may shorten the life of VibroBlock components such as springs and spring mounting screws. Higher frequencies may cause the need to lower VibroBlock angles. The second special application we will discuss is: Tuning to a lower frequency. There is rarely a need to tune to a lower frequency. The main reason to do so is in the case of a very large or heavy bowl that requires a maximum spring stack. In this case, lowering the frequency may increase the life of VibroBlock components. Another reason would be a feed system that can vastly over feed. Reducing the frequency will decrease audible noise. Please note that VibroBlock angles may need to be increased at lower frequencies. Lower frequencies will generally cause VibroBlocks to run cooler as higher frequencies will generally cause VibroBlocks to run hotter. Experimenting with different frequencies can often help solve problem applications but is not usually necessary. 10 rev3 6/21/10