Three-phase monitoring relay CM-PBE

Similar documents
Three-phase monitoring relay CM-PVE

Three-phase monitoring relay

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Three-phase monitoring relay

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Three-phase monitoring relays CM-PFE and CM-PFE.2

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Three-phase monitoring relay CM-PFS

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Three-phase monitoring relays

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Liquid level monitoring relay CM-ENS.2x

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-SDD.22

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-TGD.22

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MFS.21

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Power supply CP-D 12/2.1

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Three-phase monitoring relays Product group picture

Power supply CP-T 24/10.0 Primary switch mode power supply

Three-phase monitoring relays Product group picture

Power supply CP-T 48/20.0 Primary switch mode power supply

Three-phase monitoring relays Table of contents

Power supply CP-T 24/40.0 Primary switch mode power supply

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 24/20.0 Primary switch mode power supply

Electronic timer CT-SDE

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Control module CP-A CM

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Thermistor motor protection relays

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Power supply CP-E 24/0.75

Primary switch mode power supplies Product group picture

Power supply CP-D 24/1.3

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Power supply CP-D 24/4.2 Primary switch mode power supply

Thermistor motor protection relays

Pluggable interface relays CR-U Universal relays

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Control module CP-A CM

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

CP-E range Benefits and advantages

CP-T range Product group picture

Power supply CP-E 24/2.5

CP-T range Benefits and advantages

Grid feeding monitoring relay acc. VDE AR-N 4105 CM-UFD.M21

Subject to changes 11/2003 Page 1/7

ABB ABB 59 2CDC110004C0205. Measuring and monitoring relays. CM and C5xx range. Content

Analog signal converters CC range

Analog signal converters CC-E I/I

CM-IWM.11 Insulation monitoring relay

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Liquid level monitors and controls

Signal converters Index

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

Moeller Electric Corporation

Transcription:

Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of three-phase mains for phase failure With or without neutral monitoring Device with neutral monitoring can also be used to monitor single-phase mains Powered by the measuring circuit 1 n/o contact 25 mm (0.89 in) width 1 LED for the indication of operational states Approvals A UL 508, CAN/CSA C22.2 No.14 R EAC K CB scheme E CCC L RMRS Marks a CE b C-Tick Order data Three-phase monitoring relays Type Rated control supply voltage = measuring voltage Neutral monitoring Order code CM-PBE 3 x 380-440 AC, 220-240 AC yes 1SR550881R9400 CM-PBE 3 x 380-440 AC no 1SR550882R9500

Functions Operating controls 1 Indication of operational states R: yellow LED Relay status 1 2CDC 251 007 S0012 Application / operating mode The CM-PBE is designed for use in three-phase mains for monitoring the phase parameter phase failure (U meas < 60 % x U n ). The CM-PBE with neutral monitoring is also suitable for monitoring single phase mains. For this, all three external conductors (L1, L2, ) have to be jumpered and connected as one single conductor. The CM-PBE works according to the closed-circuit principle. Indication of operational states LEDs, status information and fault messages Operational state Output relay energized R: LED yellow 2 - Three-phase monitoring relay CM-PBE Data sheet

Function descriptions / diagrams Phase failure monitoring If all phases (and the neutral) are present, the output relay energizes after the fixed start-up delay is complete. If a phase failure occurs, the fixed tripping delay t v starts. When timing is complete, the output relay de-energizes. As soon as the voltage returns to the tolerance range, timing of starts. When timing is complete, the output relay reenergizes automatically. The LED R glows when the output relay is energized. CM-PBE with neutral monitoring L1, L2,, N Measuring value L1, L2,, N L1, L2, N L1, L2,, N L2,, N L1, L2,, N L1, L2 L1, L2,, N L1 N t v < <t v 13-14 R: yellow LED = Start-up delay fixed 500 ms t v = Tripping delay fixed 150 ms 2CDC 252 045 F0203 CM-PBE without neutral monitoring L1, L2, Measuring value L1, L2, L1, L2 L1, L2, L1, L2 L1, L2, L1, L2 L1, L2, t v < <t v 13-14 R: yellow LED = Start-up delay fixed 500 ms t v = Tripping delay fixed 150 ms 2CDC 252 046 F0203 Electrical connection L1, L2,, (N) Control supply voltage = measuring L1 L2 L1 L2 voltage 13-14 Output contact - closed-circuit principle L1 L2 13 L1 L2 13 N N 13 14 14 1SC 110 000 F0112 13 14 14 1SC 110 000 F0113 Connection diagram CM-PBE with neutral monitoring Connection diagram CM-PBE without neutral monitoring Data sheet Three-phase monitoring relay CM-PBE - 3

Technical data Data at T a = 25 C and rated values, unless otherwise indicated Input circuits Type CM-PBE 1) CM-PBE Supply circuit = measuring circuit L1, L2,, N L1, L2, Rated control supply voltage U s = measuring voltage 3 x 380-440 AC, 220-240 AC 3 x 380-440 AC Rated control supply voltage U s tolerance -15...+15 % Rated frequency 50/60 Hz 1) Device with neutral monitoring: The external conductor voltage towards the neutral conductor is measured. Measuring circuit L1, L2,, N L1, L2, Monitoring functions Phase failure J J Interrupted neutral J - Measuring ranges 3 x 380-440 AC, 220-240 AC 3 x 380-440 AC Thresholds U min U max 0.6 x U n Hysteresis related to the threshold value fixed 5 % (release value = 0.65 x U n ) Rated frequency of the measuring signal 50/60 Hz (-10...+10 %) Response time 40 ms Timing circuit Start-up delay T s fixed 500 ms (w20 %) Tripping delay T v fixed 150 ms (w20 %) User interface Indication of operational states Relay status R yellow LED Details see table LEDs, status information and fault messages on page 2 and Function descriptions / diagrams on page 3. Output circuits Kind of output 13-14 relay, 1 n/o contact Operating principle closed-circuit principle 2) Contact material AgCdO Rated operational voltage U e (IEC/EN 60947-1) 250 Minimum switching voltage / Minimum switching current 250 DC, 250 AC Rated operational current I e AC12 (resistive) at 230 4 A (IEC/EN 60947-5-1) AC15 (inductive) at 230 3 A DC12 (resistive) at 24 4 A DC13 (inductive) at 24 2 A AC rating (UL 508) Utilization category (Control Circuit Rating Code) B 300 max. rated operational voltage 300 AC max. continuous thermal current at B 300 5 A max. making/breaking apparent power at B 300 3600/360 A Mechanical lifetime 30 x 10 6 switching cycles Electrical lifetime AC12, 230, 4 A 0.1 x 10 6 switching cycles Maximum fuse rating to achieve n/c contact 10 A fast-acting short-circuit protection n/o contact 10 A fast-acting 2) Closed-circuit principle: Output relay is de-energized if the measured value exceeds/drops below the adjusted threshold. 4 - Three-phase monitoring relay CM-PBE Data sheet

General data MTBF on request Duty time 100 % Dimensions (W x H x D) product dimensions 22.5 x 78 x 78.5 mm (0.89 x 3.07 x 3.09 in) packaging dimensions 24 x 83 x 25 mm (0.94 x 3.27 x 0.98 in) Weight net weight 0.066 kg (0.146 lb) gross weight 0.078 kg (0.172 lb) Mounting DIN rail (IEC/EN 60715) Mounting position any Degree of protection housing IP50 terminals IP20 Electrical connection Wire size fine strand with wire end ferrule 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) Stripping length Tightening torque fine strand without wire end ferrule rigid 2 x 1-1.5 mm 2 (2 x 18-16 AWG) 2 x 0.75-1.5 mm 2 (2 x 18-16 AWG) 10 mm (0.39 in) 0.6-0.8 Nm (5.31-7.08 lb.in) Environmental data Ambient temperature ranges operation -20...+60 C storage -40...+85 C Damp heat, cyclic (IEC 60068-2-30) Operational reliability (IEC 68-2-6) Mechanical resistance (IEC 68-2-6) 24 h cycle time, 55 C, 93 % rel., 96 h 6 g 10 g Isolation data Rated insulation voltage U i supply circuit / measuring circuit (DE 0110, IEC/EN 60947-1) / output circuit 400 Rated impulse withstand voltage U imp all isolated circuits (DE 0110, IEC/EN 60664) 4 k, 1.2/50 µs Test voltage between all isolated circuits (routine test) 2.5 k, 50 Hz, 1 min. Pollution degree (DE 0110, IEC/EN 60664, IEC/EN 60255-5) 3 Overvoltage category (DE 0110, IEC/EN 60664, IEC/EN 60255-5) III Standards Productandard IEC/EN 60255-6 Low oltage Directive EMC directive 2006/95/EC 2004/108/EC Electromagnetic compatibility Interference immunity to IEC/EN 61000-6-2 electrostatic discharge IEC/EN 61000-4-2 Level 3 (6 k / 8 k) radiated, radio-frequency, IEC/EN 61000-4-3 Level 3 (10 /m) electromagnetic field electrical fast transient / burst IEC/EN 61000-4-4 Level 3 (2 k / 5 khz) surge IEC/EN 61000-4-5 Level 4 (2 k L-L) conducted disturbances, induced by IEC/EN 61000-4-6 Level 3 (10 ) radio-frequency fields Interference emission IEC/EN 61000-6-4 Data sheet Three-phase monitoring relay CM-PBE - 5

Technical diagrams Load limit curves 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 194 F0205 300 200 100 80 60 50 40 30 20 10 0.1 0.2 0.5 resistive load 1 2 4 6 10 I A 2CDC 252 193 F0205 AC load (resistive) DC load (resistive) F 1.0 0.9 0.8 0.7 0.6 Switching cycles 250 resistive load 0.5 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 cos ϕ Derating factor F for inductive AC load 2CDC 252 192 F0205 Switching current [A] 2CDC 252 148 F0206 Contact lifetime 6 - Three-phase monitoring relay CM-PBE Data sheet

Dimensions in mm and inches 88.5 3.48 81 3.19 22.5 0.886 78 3.07 78.5 3.09 2CDC 252 189 F0005 Further documentation Document title Document type Document number Electronic products and relays Technical catalogue 2CDC 110 004 C020x You can find the documentation on the internet at www.abb.com/lowvoltage -> Control Products -> Electronic Relays and Controls -> Three Phase Monitors. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com/partcommunity/portal/ abb-control-products -> Low oltage Products & Systems -> Control Products -> Electronic Relays and Controls -> Three Phase Monitors -> CM-PBx - Three Phase Monitors. Data sheet Three-phase monitoring relay CM-PBE - 7

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 10 16 80 69006 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low oltage Products and Systems Document number 2CDC 112 194 D0201 Rev B (08.2014) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 2014 ABB All rights reserved