INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE

Similar documents
LE7. user manual for the LE7 product line (x2, x4, x6, IR) 06 February 2018

iq-led Software V2.1

Miniaturized Spectroradiometer

Spectroradiometer specbos 1201

Solid State Luminance Standards

Solutions to test imagequality

Product tags: VIS, Spectral Data, Color Temperature, CRI, Bilirubin, PAR, Scotopic, Luminous Color, Photometry, General lighting

We bring quality to light. MAS 40 Mini-Array Spectrometer

specification display & lighting hera spectrometer

A Spectral Database of Commonly Used Cine Lighting Andreas Karge, Jan Fröhlich, Bernd Eberhardt Stuttgart Media University

AvaLight-DHc Full-range Compact Light Source

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

lightstudio light box to illuminate a scene with different standardized light types

Product tags: VIS, Spectral Data, Color Temperature, CRI, Waterproof, WiFi, Luminous Color, LED, Photometry, General lighting

We bring quality to light. LumiCam 1300 Imaging Photometer/Colorimeter

Broadbandradiometer specbos 1211

PHOTO RESEARCH, INC. PR-730 / PR-735 and PR-740 / PR-745 SpectraScan

Multispectral. imaging device. ADVANCED LIGHT ANALYSIS by. Most accurate homogeneity MeasureMent of spectral radiance. UMasterMS1 & UMasterMS2

BTS256-EF. Product tags: VIS, Spectral Measurement, Waterproof, WiFi. Gigahertz-Optik GmbH 1/7

Imaging Photometer and Colorimeter

Unprecedented Resolution and Accuracy For Camera & Image Sensor Calibration

LED Tester BTS256-LED

ISS-30-VA. Product tags: Integrating Sphere Source. Gigahertz-Optik GmbH 1/5

MK350 Portable Spectrometer

BTS256-E WiFi - mobile light meter for photopic and scotopic illuminance, EVE factor, luminous color, color rendering index and luminous spectrum.

Integrating Spheres. Why an Integrating Sphere? High Reflectance. How Do Integrating Spheres Work? High Damage Threshold

Optoliner NV. Calibration Standard for Sighting & Imaging Devices West San Bernardino Road West Covina, California 91790

LM Test Report

Spider Pulse Characterization

JETI Specbos Instruments

Bridgelux Gen 7 V8 Array. Product Data Sheet DS104

Spectral Photometry BASE

BTS2048-VL-CP-ILED-B-IS-1.0-HL

Chameleon Spectroradiometer

71332 LED Dusk To Dawn (Area Light)

SPECTRAL SCANNER. Recycling

INTERFEROMETER VI-direct

specification light bulb cronus bhaskar spectrometer & colorimeter for light bulb measurements

LED Lighting Flux and Color Measurement System (LFC)

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

Vixar High Power Array Technology

Photometry and Light Measurement

Optical Sensor Systems from Carl Zeiss CORONA PLUS. Tuned by Carl Zeiss. The next generation in the compact class

GL spectis 1.0 Touch The world s first smart spectrometer.

Table 8 Overview light sources

A Handheld Image Analysis System for Portable and Objective Print Quality Analysis

Telecentric lenses.

NVLAP LAB CODE LM Test Report. For. MaxLite Inc. (Brand Name: MaxLite) 12 York Ave West Caldwell NJ 07006

Novel Approach for LED Luminous Intensity Measurement

Where Image Quality Begins

LED Tester BTS256-LED

PRODUCTION DATA SHEET

Diogen Lighting,Inc 14 Inverness Drive East,Ste.E-128 Englewood, CO T8L W BEST Test Service Shenzhen Co., Ltd.

Radiometric and Photometric Measurements with TAOS PhotoSensors

BTS256-PAR. Product tags: VIS, Spectral Data, PAR, Waterproof, General lighting.

771 Series LASER SPECTRUM ANALYZER. The Power of Precision in Spectral Analysis. It's Our Business to be Exact! bristol-inst.com

Standard Viewing Conditions

Bridgelux Vesta Series Tunable White 9mm Array. Product Data Sheet DS152

LM Test Report

CAMAG TLC VISUALIZER 2

Spectral Pure Technology

Solea. Supercontinuum Laser. Applications

Full Spectrum. Full Calibration. Full Testing. Collimated Optics, Software and Uniform Source Solutions

Optical In-line Control of Web Coating Processes

Company synopsis. MSU series

LED Floodlight. RoHS. Model: inner box: L 17" X W 12.5" X H 9.33" 1PCS AC 50/60HZ. Input Voltage 0.85A MAX. Input Current 78 W.

LuxiGen Platform ENTERTAINMENT LIGHTING ARCHITECTURAL LIGHTING HIGH-END INTERIOR SPACES UV CURING INFRARED ILLUMINATION HORTICULTURE & SPECIALTY

Spectral Analysis of the LUND/DMI Earthshine Telescope and Filters

Properties of LED considering museum lighting

Achieving 100,000 : 1 contrast measurement

Eight Tips for Optimal Machine Vision Lighting

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

NVLAP LAB CODE LM Test Report. For. Hocan Group Co.,Ltd. Rm 1902, Easey Comm Bldg Hennessy Rd Wanchai, HONG KONG

The Art of Light Measurement. Avantes BV Apeldoorn, The Netherlands

LED Slim Panel 48 W PRODUCT DATA SHEET

NVLAP LAB CODE LM Test Report. For. Maxlite Inc. (Brand Name: ) 12 York Avenue, West Caldwell, NJ

operating manual iliad for Windows & Mac OS X software application rc81

KL Series. Fiber optic illumination for stereo microscopy

NIST Agency Report May 2012 OUTLINE. The case for traceability NMI capabilities A view to the future the HIP Current/recent NIST activities

LED14.5WPAR30S/FL/827-DIM

IESNA LM-79: Measurement and Test Report for Halco Lighting Technologies ATL 2940-A PACIFIC DRIVE. Dec 08, 2014

WE BRING QUALITY TO LIGHT DTS 500. Positioner Systems AUTOMATED DISPLAY AND LIGHT MEASUREMENT

Report No.: HZ b. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For. Maxlite INC. (Brand Name: Maxlite) 12 York Ave., West Caldwell, NJ 07006

LM Test Report

Report No.: HZ c/R1. Total Luminous Flux (Lumens) Stabilization Time (Light & Power) Table 1: Executive Data Summary CRI

NVLAP LAB CODE LM Test Report. For GREEN INOVA LIGHTING TECHNOLOGY (SHENZHEN) LTD. (Brand Name: GI LED LIGHTING)

Cat# LED Wall-PACK

Ultrafast instrumentation (No Alignment!)

LEDs for Flash Applications Application Note

POTENTIAL OF MULTISPECTRAL TECHNIQUES FOR MEASURING COLOR IN THE AUTOMOTIVE SECTOR

07-Lighting Concepts. EE570 Energy Utilization & Conservation Professor Henry Louie

High Precision CCD Spectroradiometer & Integrating Sphere Test System LPCE-2(LMS-9000B) Brochure. Global Office of Lisun Electronics Inc.

LEDView LIGHTING CABINET. User Manual

Thermography. White Paper: Understanding Infrared Camera Thermal Image Quality

NVLAP LAB CODE LM Test Report. For MAXLITE INC. (Brand Name: MAXLED) 12 York Avenue West Caldwell, NJ

BTS2048-BS. Product tags: VIS, Spectral Data, Industrial Applications, Laser.

APPLICATION NOTE. Computer Controlled Variable Attenuator for Tunable Lasers. Technology and Applications Center Newport Corporation

Ambient Light Sensors General Application Note

Led Tube Light KLV-T8-121-WA by KLV Ledverlichting

Transcription:

Image Engineering imagequalitytools INNOVATIVE CAMERA CHARACTERIZATION BASED ON LED LIGHT SOURCE Image Engineering

Relative Power ILLUMINATION DEVICES imagequalitytools The most flexible LED-based light source is the heart of all adaptive IE lighting products Create your own light by adjusting the 22 channels in the visible range to suit your needs. You can automatically simulate standard light sources, reconstruct the daylight distribution from dawn until dusk, create patches of a high-saturated color chart, or reconstruct the spectral distribution of a measured light source. By using the individual channels, you can even measure the spectral sensitivities of a camera. The provides you with the closest match to standard D light sources in a broad range from 400 up to 820 nm. Aside from many other predefined light sources, you will also be able to generate your own custom spectra in combination with the spectral radiometer EX2. The intensity variation is realized with a pulse width modulation (PWM) of 32 khz, in order to enable working with short exposure times. Linear tuning of the intensity for each channel using 1000 steps provides an accurate way to manipulate every part of the spectrum. The internal temperature stabilization enables a constant spectrum for a period of a fraction of a second, to well over a few hours. A software-based, quick and easy self-calibration avoids any kind of effects caused by burnin or long-term degradation of the LEDs on predefined spectra, ensuring a long lifetime. Due to its extremely short response time, light settings can be changed with frequencies of up to 40 Hz. The technical characteristics of the are particularly designed for the higher requirements in the area of camera testing and camera calibration. On request, we supply the system as a stand-alone version. We combine it with a NIST traceable calibrated spectrometer and the control software, which allows you to create your own light source adapted to your needs. The standard module consists of 22 different channels and 80 LEDs arranged on a 10 x 10 cm board. This board can be combined with other boards to form larger and more intense light sources. The extension module was developed to extend the spectral range to the infrared region. It also consists of 80 LEDs on a 10 x 10 cm board, but it has 11 channels mostly in the IR region. It is typically used in combination with two standard 1,00 0,75 0,50 0,20 0,00 400,0 450,0 500,0 550,0 600,0 650,0 700,0 750,0 800,0 Wavelength (nm) Comparison of D65 spectra: HQ Fluorescence and D65 standard illuminant D65 generated D65 HQ fluorescence light modules so as to level the intensities of all channels. In order to offer you an opportunity to integrate the in your individual test procedures, we optionally provide a C++ Application Programming Interface () for the entire product line. Basic free selectable spectral distribution fast calibration constant spectral distribution for every intensity level predefined standard illuminants (A, B, C, D50, D75) black body curve by selected CCT (correlated color temperature) auto generation of external measured or imported spectra creation of individual test sequences real time display of spectral measurement real time calculation of CCT, CRI, illumination level C++ available A grant for the flexible simulation of light types. SOFTWARE Desktop control software and EX2 for devices are included Software Basic suitable for any device user friendly interface handles of multiple devices saving and loading illuminants controlling every single spectral channel composing and running illumination sequences spectrometer aided control loop for high-precision illuminants device calibration ensuring constant quality at the highest level 2 Calculated quantities Photometry: Illuminance [lux] Luminance [cd/m²] Correlated Color Temperature (CCT) [K] Color rendering index (CRI) Colorimetry: color difference Delta E (CIE 2000) between actual and reference illuminant Accuracy: accordance between actual and reference spectrum (FIT) Spectral Camera Calibration Index (SCI)

imagequalitytools ILLUMINATION DEVICES Application Programming Interface The provides a comprehensive and intuitive programming interface for the light source and the EX2 spectrometer. The enables you to write your own software using all of the advantages of the device while staying as fl exable as possible by focusing only on your requirements. Of course, its integration into already existing software systems is also possible. LE7 Uniform, multispectral, powered chart illumination par excellence A software controlled integrating sphere with an internal mini spectrometer for spectral control and homogeneous illumination of transparent test charts in size D280. Depending on the device power, intensities can be set between 25 and 6000 lx. The consists of classes which represent physical devices as well as convenient data container classes. Its interface only depends on standard ISO C++ and its Standard Library STL. All required hardware drivers are supplied. Extensive documentation is accompanied by useful and practical code examples leading you through the most commonly used cases. Application Programming Interface available Basic Features high homogeneity >97% available with different max illumination values integrated mini spectrometer to verify your spectral distribution in real time LE7-IR Tuneable light spectrum extended to IR LE7-IR is the extended version of the LE7. The 480 LEDs of the light source create different spectra not only in the visible but also in the near infrared spectrum up to 1050 nm. Basic Features LE7 Features extended spectral range from 380 up to 1050 nm CAL Camera characterization and calibration light sources Today more than ever camera technology is subject to constant change. In order to keep pace with the market s quality requirements, the need for a reliable test system grows. For the characterization and calibration of cameras in the laboratory, or in the production line, the specialists of Image Engineering have developed the CAL product line. These compact calibration light sources are equipped with multispectral technology and offer the highest degree of fl exibility in your choice of lighting type. You only need one device for all light sources such as A, D50, D65, or any other standard light source or self-generated spectra. For spectral sensitivity measurements, the CAL product line allows for the individual activation of each of the 20 narrow band color channels. The special design, connected with a non-refl ecting special diffuser fi lter, ensures an even light distribution on the measuring plane. As a result of the s very short response time, a full calibration can be performed in a few seconds if the image processing and transfer in the camera is fast enough. The easy-to-use control software controls the CAL devices or, if upgraded with the C++, they can be integrated into your individual test procedures. The different CAL devices feature the main functions of the iq- LED. Possible applications are: calibration of the exposure control detection of defect pixels determining the luminance and color shading checking of the auto white balance under various light sources (i.e. A, C, D50 D55, D65, D75) measurement of the spectral sensitivity 3

ILLUMINATION DEVICES imagequalitytools CAL1 The one light source solution in the fi eld of camera characterization and calibration Its compact design consists of one element in a 0.3 m integrating sphere that illuminates a 70 mm opening. Basic Features high homogeneity >98% integrated mini spectrometer CAL3 Camera calibration light source based on for wide-angle lenses Its design consists of one spectral programmable element in a 0.3 m integrating sphere that illuminates a 38 mm concave curved luminous surface. Basic Features high homogeneity >95% concave curved luminous surface for wide-angle lenses integrated mini spectrometer iq-align Precise adjustment for extreme wide-angle cameras in front of calibration light sources CALI and CAL3 For a comfortable and precise adjustment of cameras in the security and automotive area, we recommend iq-align. It can be used with the calibration light sources CAL1 and CAL3. The camera align system is based on a linear guidance in combination with an iq-mobilemount. CAL2 The small light source for the flexible integration into a production line The CAL2 can substitute for multiple devices on a production line. It solves 90% of all calibration issues and it saves time and money. The 60 x 60 mm large opening allows you to calibrate multiple cellphone camera modules at the same time, while also making calibration faster and more accurate than with any other device. The device can also be used for camera calibration and testing purposes when space is limited. In this case, the spectrometer, utilized for calibrating the device, is separated from the light source. This means one single spectrometer can be operated for several calibration stations equipped with the CAL2. Should there be any special requirements regarding implementation into your test setup and workfl ow, the whole system can be customized to fi t your needs. The special internal design, for which we have a patent pending, allows you to achieve a similar uniformity (>96%) and intensity (up to 3000 lx) that we have in the CAL1 with its integrating sphere. Basic Features high homogeneity >96% mini spectrometer for calibration ideal for production line integration 4

imagequalitytools ILLUMINATION DEVICES iq-flatlight The spectrally tunable source to illuminate large areas The iq-flatlight is designed to illuminate larger areas, such as our size A1066 test charts, or even small rooms with the comfort of a spectrally tunable light source. The iq-flatlights are normally sold as a pair, where each of the two units has an approximate luminous area of 0.7 x 0.7 m 2 and consist of 10 or 20 modules. The construction allows the lights to be fi xed on ceilings or walls in different ways. In combination with a camera test stand, they come on rollable stands that can be adjusted in front of the test charts in a fl exible way to achieve uniform illumination. The illumination of large charts and areas has never been more fl exible. Basic Features illuminates large areas mini spectrometer included iq-chart BOX Compact LED illumination unit for refl ective charts The iq-chart Box makes it possible to illuminate refl ective test charts quickly and homogeneously. It is the compact solution for providing optimal conditions for the image quality testing of cameras and cell phones. The light source consists of 8 iq- LED modules. Chart changing is carried out quickly and easily by means of a movable carriage. Basic Features compact high uniformity low light conditions with ND fi lters down to 1,5 lx LIGHT HEAD A technological breakthrough in test scene illumination The lighthead provides the possibility to illuminate the real scene of the ligthstudio for visual analysis with every standard illumination or any other kind of light. Several iq- LED modules are combined into a single light head to reach an adequate illumination level. Just as our other -based products, the lighthead works with an internal spectrometer, to enable realtime measurements of the spectrum in your scene. The lightstudio is availabel with different features, please have a look on our website (www.image-engineering.com). EX2 Measure daylight or light sources with one of the smallest calibrated spectral radiometers The EX2 is based on the same mini spectrometer that is used in our adaptive lighting products. With its compact design and connection through just one USB cable to your laptop, you can measure the spectral distribution of any kind of light source when and wherever needed. The EX2 comes fully NIST traceable calibrated and with an easy-to-use software. After measuring a light source, you can import the spectral distribution to all of your products control software and reproduce it in just a few seconds. EX2 Principle Spectral range VIS version Spectral range VIS-IR version Resolution VIS version Resolution VIS-IR version Integration time Control system mini spectrometer for directive measurement via optical fiber opening (~25º FOV) or cosine corrector add on (~180º FOV) 350 870 nm 380 1100 nm Sensor: 2024 pixel/ FWHM: 2.4 nm Sensor: 2024 pixel / FWHM: 2.35 nm 1.05 ms 10 minutes software based control Main usable everywhere easy and quick handling measure spectral distribution System requirements Calibration Windows 7 operating system (or higher) NIST traceable calibrated It is recommended to recalibrate the EX2 once a year, regardless of the operating hours 5

ILLUMINATION DEVICES imagequality Principle Light source LE7 WITH 2 LE7 WITH 4 LE7 WITH 6 LE7-IR 2 x 160 LEDs, 22 channels (20 color, 2 white) 4 x 320 LEDs, 22 channels (20 color, 2 white) integrating sphere 6 x 480 LEDs, 22 channels (20 color, 2 white) 4 x 2 x IR extension 480 LEDs, 33 channels (31 color, 2 white) Spectral range 400 820 nm 380 1050 nm Predefined standard illuminants D50, D55, D65, D75, A, B, C Planckian spectral curve by selected temperature (1900-18,000 K) Uniformity of illumination active chart area (>97%) resp. full chart area (>96%) Illumination stability +/- 2%** Maximum / Minimum illumination values +/- 2% (380 820 nm) +/- 4% (820 1050 nm) Standard D illuminants: 1400 lx Standard D illuminants: 2800 lx Standard D illuminants: 4200 lx Standard D illuminants: 2800 lx max: up to 2000 lx max: up to 4000 lx max: up to 6000 lx max. and min. depending on illuminant and required curve fit/cri for low intensity use the system can be combined with a neutral density filter max: up to 4000 lx Intensity use Spectral measurement depending on illuminant, for low intensity use the system can be combined with a neutral density filter integrated NIST traceable calibrated mini spectrometer Spectral range /spectrometer 350 870 nm / resolution: 2048 pixel 350 1050 nm resolution: 2048 pixel easily adjustable spectral distribution of the emiting light via 22 (LE7-IR 33) software controlled LED channels, standard illuminants or Features reproduction of external measured spectra, self defined arrangements including single channels for color calibration, creation of test sequences, application programming interface () available on request ** measured for selected standard illuminants after changing an illuminant at optimal temperature See complete datasheet for detailed information. CAL1 CAL2 CAL3 Principle integrating sphere our patented edge box with adaptable design integrating sphere Light source 1 x : 80 LEDs, 22 channels (20 color, 2 white) / Spectral range Uniformity of luminance in active area Predefined standard illuminants 400 820 nm 70 mm circle* output >98% 60 x 60 mm output window >96% >95%* for FOV <160 at min. 10 mm depth inside diffuser for 160-180 FOV and at min. 20 mm depth inside diffuser D50, D55, D65, D75, A, B, C, Planckian spectral curve by selected temperature (1900 up to 18,000 K) depending on illuminant Illumination stability +/- 2%** Standard D illuminants 2000 lx 1700 lx Maximum / Minimum illumination values max. up to 3000 lx min. down to 25 lx max. up to 3000 lx min. down to 25 lx max. up to 2500 lx min. down to 25 lx depending on illuminant and required curve fit / CRI * measurement performed in the center of diffusor, standard illuminant D65 ** measured for selected standard illuminants after changing an illuminant at optimal ambient temperature iq-flatlight iq-chart BOX LIGHTHEAD Principle Light sources diffuse light panel 10 or 20 Image Engineering units: 80 LEDs/unit / 22 channels (20 color, 2 white) / 32 khz PWM / 1 or 2 F11 fluorescent tubes OSRAM L 18W/940 chart holder with illumination device (includes mini spectrometer), software controlled 8 x Image Engineering units: overall 640 LEDs 2 white and 20 color channels, 32 khz PWM, spectral range: 400 820 nm, 4 x 18 W fluorescent tubes D50 diffuse light head Spectral range 400 820 nm 400 820 nm 400 820 nm (10 PCS.): 800 LEDs, 22 channels (20color, 2 white) / / 400-820 nm / approx. lifetime 10.000 h Predefined standard illuminants D50, D55, D65, D75, A, B, C, Planckian spectral curve by selected, temperature (1900 up to 18,000 K), CRI up to 99) depending on illuminant and intensity Illumination stability +/- 2%** +/- 2%** +/- 2%** Maximum / Minimum illumination values 10 units two flatlights, illumination on chart: predefined illuminants: up to 400 lx without defined spectra: up to 1000 lx 20 units two flatlights, illumination on chart: predefined illuminants: up to 800 lx without defined spectra: up to 2000 lx max. up to 500 lx standard D illuminants: 400 lx* min. down to 25 lx with ND filters down to 1,5 lux* (depending on illuminant and required curve fit / CRI)* max. up to 600 lx / min. down to 25 lx, depending on illuminant condition: two flatlights placed beside a IE A1066 size test chart in ~80 cm distance and ~45 viewing angle * measured at center of A460 sized test chart ** measured for selected standard illuminants after changing an illuminant at optimal temperature 6 Image Engineering GmbH & Co. KG Im Gleisdreieck 5 / 50169 Kerpen-Horrem / Germany T+49 2273 99 99 1-0 / F+49 2273 99 99 1-10 / www.image-engineering.com / info@image-engineering.de