Assembly. Front view. HiC2441. SL2 1b. Termination Board

Similar documents
Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Power Rail

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. Switch Power Rail

Assembly. Front view. Parametrization interface. Power Bus

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Assembly. Front view. Switch Power Rail

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolating Repeater Input Series 9163

Binary Output Series 9175

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Binary Output without Power Supply Series 9176

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Temperature Input Module for Zone 1 Series 9482/32

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Digital Input Output Module for Zone 2 Series 9470/33

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Technical Information Barrier RB223

Inductive sensor slot-type SI2-K08-AP7

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Technical Data. General specifications. Rated operating distance s n 3 mm

Digital Input Output Module for Zone 2 Series 9470/33

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital Input Output Module for Zone 1 Series 9470/32

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Positioner with HART Communication Type 3780

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Isolators A3/1.

Remote I/O. 74 Remote I/O. Remote I/O System

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Assembly. Front view. DIP switch. LED yellow: Relay output 1. LED yellow: Relay output Power Rail

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

MINI MCR-SL-UI-I-LP-NC

Temperature Transmitter itemp RTD DIN rail TMT 127

Head mounted Temperature Transmitter TF02/TF02-Ex

2002 IS Catalog. Page

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters

D5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Rail mounted Temperature Transmitter TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Signal conditioner - MACX MCR-UI-UI-NC

Single-Channel Safety Barriers Series 9001

C330 / C330X PC-Programmable Universal, 2-wire Transmitter

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Fieldbus Isolating Repeater Series 9185/11

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Design and applications

Submersible pressure sensor For oils and fuels Model LF-1

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Level Measurement. Applications. Special features. Description

A6500-UM Universal Measurement Card

Temperature Measurement

DeltaV SIS Logic Solver

Temperature Measurement

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Level Limit Switch nivotester FTL 370, FTL 372

SINEAX TI 807 Passive DC signal isolator

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

Coupling Relays and Converters

0 2 1 â Ó. itemp HART TMT182. Technical Information

Digital I/O Coupler (4-wire) Series 9413/21

Submersible pressure sensor For water and wastewater Model LW-1

PRetrans Table of contents

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

SINEAX TV809, 1 channel Programmable Isolating Amplifier

Resistance thermometer Model TR30, compact design

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Transcription:

SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting transparency Low power dissipation 3way isolation Up to SIL acc. to IEC 608 in preparation Front view PWR LED green: Power supply Function HiC This isolated barrier is used for intrinsic safety applications. The device can transfer the following signals: as an analog input: 0/ ma... 0 ma as an analog output: 0/ ma... 0 ma as a digital input: signals from NAMUR sensors or dry contacts as a digital output: max. ma The device requires no configuration and adapts itself automatically to the function of the active input/output of the connected process control system. The device permits the bidirectional passthrough of the communication. The device is designed primarily for use with universal I/O cards (e. g. Honeywell Universal Process IO). This device mounts on a HiC Termination Board. ch Universal Barrier Place for labeling Connection Release date 0609 08:8 Date of issue 0609 6306_eng.xml AI AO DI DO ma P I. kω 0 kω Zone 0,, + SL b a a b HiC SL 8a + 7a a, b V DC a, b + Termination Board V AI ma AO V DI V DO Zone Pepperl+Fuchs Group USA: + 330 86 000 Germany: +9 6 776 Singapore: +6 6779 909

HiC Release date 0609 08:8 Date of issue 0609 6306_eng.xml General specifications type Universal Supply Connection SL: a(), b(); a(+), b(+) Rated voltage U n 9... 30 V DC via Termination Board Ripple 0 % Rated current I n 30 ma Power consumption 700 mw Analog input Transmitter supply voltage drop Ripple Analog output Load Ripple Line fault detection Digital input Open loop voltage Digital output Drive capability Open loop voltage Current limit SL: a(+), b() (wire SMART transmitter) SL: a(+), b() (wire SMART transmitter with current source) wire SMART transmitters, current sources 6 V at 0 ma (wire SMART transmitter) 0/... 0 ma, limited to approx. 0 ma (depends on control system), reverse polarity protected approx. V (current source) SL: 8a(+), 7a()... 30 V 0/... 0 ma, sink mode, working voltage... 30 V 0 mv rms SL: a(+), b() I/P converters (positioner), onsitedisplays 0/... 0 ma 0... 60 Ω 3 V at 0 ma 0 mv rms SL: 8a(+), 7a()... 30 V 0/... 0 ma > 00 kω at max. 30 V, with field wiring open SL: a(+), a() (NAMUR sensor) SL: a(+), b() (dry contact) NAMUR sensors according to IEC/EN 60976, dry contacts approx. 0 V DC, kω series resistance 0.... 9 ma SL: 8a(+), 7a() 3... 30 V 0.... 9 ma, sink mode SL: a(+), b() solenoid valves, acoustic or visual alarms V / 0 ma at 300 Ω load approx. V ma SL: 8a(+), 7a() signal: 9... 30 V DC 0signal: 0... V DC Current signal: 0... ma, depending on the output load 0signal: < 0. ma, independent of the output load Internal resistance R i 0 Ω Power dissipation. W at V, 300 Ω load (digital output) Transfer characteristics Deviation Influence of ambient temperature Switching frequency Frequency range Settling time Reaction time Electrical isolation at 0 C (68 F) ±0 µa incl. linearity, hysteresis and supply fluctuations at... 0 ma (analog input, analog output) ±60 µa incl. linearity, hysteresis and supply fluctuations at 0... ma (digital output) < µa/k (0... 60 C (3... 0 F)) < 3 µa/k (0... 0 C (0... 3 F)) 00 Hz with 0 % duty cycle (digital input, NAMUR sensor) Hz (digital input, dry contact) 0 Hz (digital output) : bandwidth by 0. V pp signal and/or ma pp signal 90... 00 Hz (analog input, analog output) 0 ms (analog input, analog output) ms (digital input, NAMUR sensor) ms, turnon/turnoff time (digital output) Pepperl+Fuchs Group USA: + 330 86 000 Germany: +9 6 776 Singapore: +6 6779 909

HiC Release date 0609 08:8 Date of issue 0609 6306_eng.xml Control/power supply basic insulation according to IEC/EN 600, rated insulation voltage 60 V eff Directive conformity Electromagnetic compatibility Directive 0/30/EU EN 636:03 (industrial locations) Conformity Electromagnetic compatibility NE :0 Degree of protection IEC 609:00 Protection against electrical shock IEC 600:00 Input EN 60976:000 Ambient conditions Ambient temperature 0... 60 C (0... 0 F) Storage temperature 0... 8 C (0... 8 F) Relative humidity 9 % noncondensing Mechanical specifications Degree of protection IP0 Mass approx. 00 g Dimensions. x 8 x 06 mm (0. x. x. in) Mounting on Termination Board Coding pin and trimmed For further information see system description. Data for application in connection with Exareas ECType Examination Certificate TÜV ATEX 3 X Group, category, type of protection II ()G [Ex ia Ga] IIC, II ()D [Ex ia Da] IIIC, I (M) [Ex ia Ma] I Supply Maximum safe voltage U m 0 V (Attention! The rated voltage can be lower.) SL: a(+), b() U o. V Current I o 0 ma Power P o 693 mw SL: a(+), b() U i < 8 V Current I i < ma U o 7. V Current I o 0 ma Power P o 0 mw SL: a(+), a() U o.6 V Current I o 3 ma Power P o mw Statement of conformity TÜV ATEX 33 X Group, category, type of protection, II 3G Ex na II T Gc [device in zone ] temperature class Electrical isolation Input/Other circuits safe electrical isolation acc. to IEC/EN 60079, voltage peak value 37 V Directive conformity Directive 0/3/EU EN 600790:0+A:03, EN 60079:0, EN 60079:00 International approvals IECEx approval IECEx TUN.000X Approved for [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex na II T Gc General information Supplementary information ECType Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperlfuchs.com. Pepperl+Fuchs Group USA: + 330 86 000 Germany: +9 6 776 Singapore: +6 6779 909 3

HiC Application examples Analog input The control system must be parameterized to an active current input. Analog output The control system must be parameterized to a current output. P I Digital input The digital input of the control system must evaluate the level of a current signal. Digital output The digital output of the control system must be parameterized in a way that the digital output powers actively a valve. The current which is provided by the control system is transferred directly to the valve. Release date 0609 08:8 Date of issue 0609 6306_eng.xml This section does not show all connection options. For further connection options see "Connection" section. Pepperl+Fuchs Group USA: + 330 86 000 Germany: +9 6 776 Singapore: +6 6779 909

HiC Characteristic Fallback characteristic for digital output U out (V) 0 300 Ω, load 0 0 30 0 I out (ma) Notes Application The device is designed as intrinsically safe interface for Universal Process IO (or Universal Safety IO) by Honeywell. Release date 0609 08:8 Date of issue 0609 6306_eng.xml Pepperl+Fuchs Group USA: + 330 86 000 Germany: +9 6 776 Singapore: +6 6779 909