BATCHFLUX and BATCHCONTROL

Similar documents
BATCHFLUX 5500 C Technical Datasheet

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

IFC 010 Signal Converter

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet

Electromagnetic flowmeters and switches DWM 1000/2000

TIDALFLUX 2300 F Technical Datasheet

OPTIFLUX 1000 Technical Datasheet

WATERFLUX 3070 Technical Datasheet

OPTISONIC Ultrasonic flowmeter for liquids in all industrial applications

WATERFLUX 3000 Quick Start

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

Magnetic-Inductive flow Meter fmi

Installation and operating instructions BATCHCONTROL 5014 C. Compact Electromagnetic Flowmeters with CANopen bus interface. Please note!

BATCHFLUX 5500 C Handbook

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

OPTIMASS 1000 Technical Datasheet

WATERFLUX 3000 Quick Start

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

FLOMID FX Electromagnetic Flowmeter

Technical Information Smartec CLD18

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

IFC 050 Technical Datasheet

Dosimass. Technical Information. Coriolis Mass Flow Measuring System For filling applications

OPTISONIC 7300 Technical Datasheet

IFC 050 Technical Datasheet

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

Flow Measurement SITRANS F M

IFC 100 Technical Datasheet

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

IFC 050 Technical Datasheet

Technical Information Smartec CLD18

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

Marketing Communications

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

The transducer component converts the measured signal and displays the actual value.

2-Wire. Level Gauge BM 702

Flow Measurement SITRANS F M

Technical Information Memosens CLS82D

OPTISONIC 6300 Technical Datasheet

Pressure transmitter For sanitary applications Model SA-11

Condumax W CLS15 and CLS15D

INSERTION paddle wheel flowmeter for continuous flow measurement

Electromagnetic Flowmeters

OPTISONIC 7300 Technical Datasheet

Signal converter for electromagnetic flowmeters

OPTITEMP TT 20 Technical Datasheet

Electro-Magnetic Flowmeters COPA-XE

OPTIFLUX 1000 Handbook

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

Measuring and Controlling Unit Multronic OC

Ambient Conditions. Operating Conditions. Pressure

Magnetic Flowmeter Systems

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

IFC 100 Technical Datasheet

Coriolis Massflowmeter

Digital conductivity transmitter

INLINE flowmeter for continuous flow measurement

Electromagnetic Flowmeter Comet F

Mass Flowmeter CoriolisMaster FCM2000

Condumax CLS15 and CLS15D

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

OPTITEMP. Compact sensors

SLW-Tri Series Sanitary Hygienic Liquid Turbine Flow Meter

Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

Condumax CLS15 and CLS15D

OPTIFLUX 2000 Technical Datasheet

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Electromagnetic Flow Transmitter

INLINE flowmeter for continuous flow measurement

TMU. Coriolis Mass Flow Meter. for liquids and gas

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

OPTISONIC 3400 Technical Datasheet

Technical Information Smartec CLD18

Design and applications

In-Line Resistance Thermometers Model TR25

INLINE flowmeter for continuous flow measurement

Manufactured by M-Sens 2 Online-Moisture Meter for Solids. Moisture % Product Information.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Measuring and Controlling Unit Multronic

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

Installation and operating instructions BATCHFLUX 5015 K. Compact electromagnetic flowmeters. Please note! KROHNE

Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys

Signal converter for electromagnetic flowmeters

OEM radar transmitter, for aggressive media level measurement

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Coriolis Massflowmeter

Transcription:

KROHNE 04/2001 D 31 BATC 02 E GR/PRINTO BATCHFLUX and volumetric batching and dosing with electromagnetic flowmeters A new era in volumetric batching!!! Optimum sanitary design Ceramic measuring tube Only 50 mm/2 overall width (DN < 25 / < 1 ) Extremely reliable and accurate Variable-area flowmeters Vortex flowmeters Flow controller Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level gauges Communications engineering Engineering systems & solutions

BATCHFLUX and... a new era in volumetric batching and dosing BATCHFLUX and electromagnetic flowmeters from KROHNE are eminently suitable for the batching and dosing of electrically conductive liquids and pastes. Fleids of application Optimum sanitary design for various sectors of the processing industry, e.g. BATCHFLUX electromagnetic flowmeter for batching and dosing applications. same as BATCHFLUX, but additionally with integrated batch controller, user programmable, backflow compensation and sensing of dribble quantities. chemical pharmaceutical cosmetics, and food. Calibrated on EN 45 001 certified calibration rigs, calibration accuracy better than 99,97 % of the measured value. 2

State-of-the art modular designed electronic unit, ensures extremely high accuracy, excellent repeatability and absolute reliability Cable entry body of stainless steel, solidly welded, shatterproof, with anti-rotation element IMoCom interface: for settings, documentation and flow recording. Only 3 W power consumption Low maintenance reuqirement. Detach 4 screws, remove cover, take out electronic unit, (no screws, no connectors to remove), insert new one, replace cover, that s it. No readjustment, no recalibration. Wastewater Background Water The ceramic measuring tube in detail Fine-grain-stablized Aluminium Oxyde Al 2 O 3 Minimal thermal expansion Only 50 mm/2 overall width for meter sizes < DN 25/< 1 CIP- and SIP-proof measuring tube of Al 2 O 3 ceramics, surface roughness < 0,8 µm, fused-in-place platinum electrodes High long-term stability, absolutely vacuum resistant, no creep or flow under pressure and temperature Many standards calibration authorities use electromagnetic ceramic flowmeters as their custody transfer and reference standards Precise centering and crevice-free gasket system through exactly defined edges of the ceramic tube No loss of accuracy following device replacement. Housings of primary head and signal converter solidly welded Self-draining, same bore diameter thorughout Hygienic design of the process connection, metal stop, no gaps Meter size Pressure rating Dimensions in mm (inches) Specific features measuring tube DN mm inches PN psig Da Di X Y 2.5 1 /10 40 580 6 (0.24) 2 (0.08) 20 (0.79) 50 (1.79) 4 1 /8 40 580 7 (0.28) 3 (0.12) 20 (0.79) 50 (1.79) 6 1 /4 40 580 9 (0.35) 5 (0.20) 20 (0.79) 50 (1.79) 10 3 /8 40 580 12 (0.47) 7 (0.28) 20 (0.79) 50 (1.79) 15 1 /2 40 580 14 (0.55) 12 (0.47) 20 (0.79) 50 (1.79) 25 1 40 580 24 (0.94) 20 (0.79) 20 (0.79) 50 (1.79) 40 1 1 /2 40 580 37 (1.46) 30 (1.18) 20 (0.79) 50 (1.79) venturi measuring tube 15 1 /2 10 145 14 (0.55) 14 (0.55) 50 (1.79) straight tube (option) Abrasive, corrosive and hot products Non-contact measurement κ 0.05 µs/cm Food, High Pressure Beverage, and special Pharmaceutical connections Integral and Remote Remote Signal converter Calibration / Measuring Principle Stainless steel housing Al 2 O 3 - measuring tube Centering groove on BATCHFLUX Centering ring on special flange sharp edge of Al 2 O 3 measuring tube Sizing / installation guides Ordering guide CERMET electrode O-ring groove deforme O-ring O-ring forced into seal gap between flange and tube device-free, almost smooth transition Batchflux/Batchcontrol 3

BATCHFLUX start filling instruction external communication Storage tank pressurized if liquid contains CO 2 pulse count inputs digital inputs digital outputs serial interface e.g. 1 pulse per ml Flowmeter BATCHFLUX pulses/volume PLC SPS Valve valve control signal Container bottle, tin, keg, paper or plastic container (pressurized if liquid contains CO 2 ) on off open valve filling time t F close valve t with integrated batch controller external communication Storage tank pressurized if liquid contains CO 2 start filling instruction digital output PLC SPS Flowmeter serial interface RS 485 Valve Container bottle, tin, keg, paper or plastic container (pressurized if liquid contains CO 2 ) Valve control signal on off t open valve filling time t F close valve 4 Batchflux/Batchcontrol

Optimization of system parameters The IMoCom interface allows visualization of system and valve properties, permitting longterm studies for optimization of the overall system. flow [ml/s] flow [ml/s] Background Valve opening: time [ms] Valve closing: time [ms] Wastewater Water Abrasive, corrosive and hot products Non-contact measurement κ 0.05 µs/cm Food, High Pressure Beverage, and special Pharmaceutical connections Signal converter Integral and Remote Remote Calibration / Measuring Principle Sizing / installation guides Ordering guide Batchflux/Batchcontrol 5

Responsibility as to suitability and intended use of our instruments rests solely with the purchaser. Technical data Meter sizes with venturi measuring tube DN 2.5, 4, 6, 10, 15, 25, 40 ( 1 /10", 1 /8", 1 /4", 3 /8", 1 /2", 1",1 1 /2") with straight measuring tube (option) DN 15 ( 1 /2" ) Connection Electrical conductivity sandwich (flangeless) design with precisely defined sealing faces 5 µs/cm ( 20 µs/cm for demineralized cold water) Ambient temperature Product temperature -25... +40 C / -13... +104 F -60... +140 C / -76... +356 F -25... +60 C / -13... +140 F -60... + 60 C / -76... +140 F (information on higher temperatures available on request) steam cleaning up to +150 C / +302 F Temperature shock resistance Temperature rising Temperature falling in 10 minutes T = 150 C = 302 F T = 120 C = 248 F sudden change T = 120 C = 248 F T = 80 C = 176 F Operating pressure Electrode design Protection category (EN 60 529/IEC 529) 40 bar / 580 psig, dependent on gaskets used (10 bar / 150 psig for DN 15 and 1 /2" with straight measuring tube) fused-in-place electrodes IP 67 equivalent to NEMA 6 (complete device, incl. signal converter) Materials of construction Housing Measuring tube Electrodes Cover seal DN 15 / 1 /2": stainless steel 1.4462 / Duplex DN 25 / 1": stainless steel 1.4301 or SS 304 AISI fine-grain-stabilized, high-density HiTec ceramics, purity 99.7 % Al 2 O 3 (+ZrO 2 ), CIP- and SIP-proof platinum silicone Low-flow cutoff cutoff on value 1-19 % cutoff off value 2-20 % Power supply Voltage 24 V DC, ± 25% (18-30 V DC) Power consumption BATCHFLUX: 3 W : 5 W adjustable Electrical connection Operator control M12 1 - connector All operating data factory-set to your specifications. Available as option for change of operating data: - HHT 010, hand-held terminal or - KROHNE software for operator control and data output via PC, connected to the IMoCom interface To help you select the right device... Meter size Optimum flow rate for filling... Filling times > 1.5 s, fill quantity... DN mm inches ml / s US Gal / min ml US Gal 2.5 1/10 3-10 0.048 0.159 10 0.003 4 1/8 10-30 0.159 0.476 20 0.005 6 1/4 20-60 0.317 0.951 40 0.011 10 3/8 60-200 0.951 3.170 100 0.026 15 1/2 150-500 2.378 7.925 200 0.053 25 1 400-1200 6.340 19.020 600 0.159 40 1 1 /2 1000-3000 15.850 47.551 1500 0.396 6 Batchflux/Batchcontrol

Responsibility as to suitability and intended use of our instruments rests solely with the purchaser. Outputs BATCHFLUX Pulse output (standard) Function passive circuit All operating data factory-set to your specifications, connection of electronic totalizers, digital pulse division, interpulse period non-uniform, therefore if frequency meters c ounters connected, allow for minimum counting interval: gate time, counter P 1000 100% [Hz] Pulse rate for Q = 100% max. 10 khz, fixed or optionally in pulses per m 3, litres, US gallons or in user-defined unit Pulse width 10 Hz: 50, 100, 200 or 500 ms > 10 Hz: automatic, pulse width = 1 2 x f 100% symmetrical, 1 : 1 Passive mode Forward/reverse flow measurement Pulse and status outputs (option 1 + 2) Pulse output Function, pulse rate and pulse width connection of electronic or electromechanical totalizers external voltage: U ext 30 V DC / 24 V AC load rating: I max 20 ma direction identified via status output (option) active circuit see pulse output (standard) above Active mode internal voltage: U ext 30 V AC load rating: I max 20 ma Status output Function all operating data factory-set to your specifications, can be set to signal direction, errors or trip points Active mode voltage internal: U int. 30 V DC load rating:: I max 150 ma Outputs Valve output 1 Valve output 2 and 3 Control input Error limits under reference conditions F = errorr in % M.V. M.V. = measured value passive, max. 300 ma, max. 30 V, switches to ground passive, max. 150 ma, max. 30 V, switches to ground passive, 20 ma, max. 30 V Pulse output DN 2.5-6 / 1 / 10 1 / 4 DN 10-40 / 3 / 8 1 1 / 2 Flow velocity v 1 m/s 3.3 ft/s F < ± 0.5 % v.m. F < ± 0.3 % v.m. v 1 m/s < 3.3 ft/s F < ± 0.4 % v.m. + 1 mm/s F < ± 0.2 % v.m. + 1 mm/s F < ± 0.4 % v.m. + 0.04 inches/s F < ± 0.2 % v.m. + 0.04 inches/s Reproducibility Fill time T F Standard deviation 1.5 s < T F 3 s 0.4 % 3.0 s < T F 5 s 0.2 % 5.0 s < T F 0.1 % Reference conditions: similar to EN 29 104 Product water at 20 C / 68 F Inlet / outlet runs 10 x DN / 5 x DN (DN = meter size) Primary head properly grounded and centered Valve closing time variation < 1 ms Flow velocity 1 m/s / 3.3 ft/s Wastewater Remote Background Water Abrasive, corrosive and hot products Non-contact measurement κ 0.05 µs/cm Food, High Pressure Beverage, and special Pharmaceutical connections Integral and Remote Signal converter Calibration / Measuring Principle Sizing / installation guides Ordering guide Wet calibrated on EN 45 001 certified calibration rigs by direct comparison of volumes. Batchflux/Batchcontrol 7

Dimensions and weights DN 2.5 15 / 1 /10 1 /2 Dimensons in mm (inches) 50 (1.97 ) 126 (4.96 ) 13,5 (0.53 ) miniature cercular connector series 713, 4 pin option: 2x M4 threaded wholes on both sides (section B-B) B 60 (2.36 ) B M4 (2x) 5,5 +0,5 0 +00.2 (0.22 0 ) M4 8 +0,5 0 +00.2 (0.31 0 ) 206 (8.11 ) option: for ventilation 29 (1.14 ) 44 (1.73 ) 50 (1.97 ) 54-0,2 (2.13-0.01) flow direction G 1/ 8 19 1 (0.04 ) M6 (4x) STC 56 option: 4x M6 threaded wholes on both sides (section M-M) 20 M M 5,5 +0,5 0 +00.2 (0.22 0 ) M6 8 +0,5 +00.2 0 (0.31 0 ) 10 ø30,6 ±0,05 (1.20 ±0.002 ) ød1 ø30,6 ±0,05 (1.20 ±0.002 ) 2±0,2 (0.08 ±0.01 ) 2±0,2 (0.08 ±0.01 ) X1 X2 option: for Batchcontrol Meter size Dimension ø d 1 Weight DN inches mm (inches) kg (lb) 2.5 1 /10 6 (0.24) 1.6 (3.6) 4 1 /8 7 (0.28) 1.6 (3.6) 6 1 /4 9 (0.35) 1.6 (3.6) 10 3 /8 12 (0.47) 1.6 (3.6) 15 1 /2 14.3 (0.56) 1.6 (3.6) 8 Batchflux/Batchcontrol

Dimensions and weights DN 25 40 / 1 1 1 /2 Dimension in mm (inches) 50 (1.97 ) 126 (4.96 ) 13,5 (0.53 ) Background miniature cercular connector, series 713, 4 pin Wastewater Water Abrasive, corrosive and hot products b ød1 ød2 f Non-contact measurement κ 0.05 µs/cm g e c +0,5 (+0.03 ) a -0,4 (-0.02 ) a Food, High Pressure Beverage, and special Pharmaceutical connections Signal converter Integral and Remote Remote Calibration / Measuring Principle Meter size Dimension in mm (inches) Weight DN inches a b c e f g kg lb 25 1 58 (2.28) 200 (7.87) 55 (2.17) 102 (4.02) 68 (2.68) 34 (1.34) 1.6 (3.6) 40 1 1 /2 83 (3.27) 215 (8.46) 80 (3.15) 117 (4.61) 83 (3.27) 42 (1.65) 2.3 (5.1) Sizing / installation guides Ordering guide Batchflux/Batchcontrol 9

Electrical connection To ensure correct functioning of your flowmeter, please take note of the following. Overvoltage class: in conformity with VDE 0120 and IEC 664, the integral flowmeters are designed for overvoltage category III in the supply circuits and overvoltage category II In the output circuits. Safety isolation: the integral flowmeters need to be fitted with an Isolating facility. Electrical connection and repairs may only be carried out by specialists. Folgende Hinweise einhalten, um einwandfreie Funktion zu gewährleisten. Power supply (voltage) 24 V DC ± 25 %. For measurement reasons, connect the FE functional ground of the power supply to the remote U-clamp terminal on the signal converter housing. Forfunctional extra-low voltage of 24 V DC, protective separation (PELV) must be ensured (VDE 0100 / VDE 0106 and IEC 364 / IEC 536 or equivalent national regulations). Protect flowmeters against direct radiant heat (e.g. hot product tanks), insulate if necessary. Do not expose flowmeters to intense vibration; if necessary, support the pipeline on both sides of the flowmeter. Level of vibration according to IEC 068-2-34; below 2.2 g in the 20-150 Hz frequency range. BATCHFLUX Standard version Option 1 Option 2 4-pin connector M12 1 for power supply 24 V DC and passive pulse output 4-pin connector M12 1 for power supply 24 V DC and active pulse and status outputs, switch to ground of the supply power same as Option 1, both outputs switch to +24 V DC of the power supply Pin Standard Option 1 Option 2 1 + 24 V + 24 V + 24 V 2 pulse output status output (to ground) status output (to +24 V) 3 pulse output pulses output (to ground) pulse output (to +24 V) 4 ground ground ground Pin Connector X1 Connector X2 1 1st switching output Profibus - B - 2 2nd switching output Profibus - A - 3 +24 V control input 4 ground 3rd switching output Pin assignment (customer-specific arrangement possible) 10 Batchflux/Batchcontrol

Connection diagrams BATCHFLUX Standard 4 3 ground Wastewater Background Water 2 1 Option 1 4 3 status output pulse output pulse output power supply 24 Volt DC ground power supply Abrasive, corrosive and hot products Non-contact measurement κ 0.05 µs/cm Food, High Pressure Beverage, and special Pharmaceutical connections 2 1 Option 2 24 Volt DC Integral and Remote Remote Signal converter 4 3 2 1 status output pulse output ground power supply 24 Volt DC Calibration / Measuring Principle Sizing / installation guides Ordering guide Batchflux/Batchcontrol 11