FLOWMETER. Siemens MAG 5000/6000. Overview

Similar documents
SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Electromagnetic flowmeters Transmitter types MAG 5000, MAG 6000

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

SITRANS F M System information SITRANS F M electromagnetic flowmeters

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Coriolis Massflowmeter

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Coriolis Massflowmeter

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

TMU. Coriolis Mass Flow Meter. for liquids and gas

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR300. 5/180 Siemens FI Overview

OPTIFLUX 5000 Technical Datasheet

Electromagnetic flowmeters Sensor types MAG 1100, MAG 3100, MAG 5100 W Signal converter types MAG 5000, MAG 6000

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

Electro-Magnetic Flowmeters COPA-XE

SITRANS T measuring instruments for temperature

Level Measurement Continuous level measurement Radar transmitters

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

Flow Measurement SITRANS F US Inline

Flow Measurement. SITRANS F US Inline. Flowmeter SITRANS FUS380 standard. 4/254 Siemens FI Overview

SALES SERVICE +358 (0)

Coriolis Mass Flow Meter Model TM

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Clamp-on ultrasonic flowmeters have six product families: max. 2% solids

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

SITRANS F flowmeters SITRANS F US. Flowmeter FUE380 with approval. 4/230 Siemens FI Overview

OPTIFLUX 5000 Technical Datasheet

VersaFlow Ultrasonic clamp-on Flowmeter Technical Datasheet. Specification. Applications. Highlights. Industries. 34-VF September 2009

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Target disk flowmeter for liquids and gases

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

OPTIFLUX 1000 Technical Datasheet

Coriolis Massflowmeter

Magnetic-Inductive flow Meter fmi

Electromagnetic flowmeters and switches DWM 1000/2000

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Condumax W CLS15 and CLS15D

Electromagnetic Flow Transmitter

E l e c t r o m a g n e t i c f l o w m e t e r s

Ambient Conditions. Operating Conditions. Pressure

Magnetic Inductive Flowmeter

TME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C

VersaFlow TWC 9000/TWC 010 Coriolis Mass Flow Converter Specifications

EN-2018 MAGNETIC FLOW METERS

INDUSTRIAL CONTROL INSTRUMENTS FOR PROCESS AUTOMATION. Configuration. Installation

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

LST400 Ultrasonic level / open channel flow transmitter

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Temperature Input Module for Zone 1 Series 9482/32

IFC 300 Technical Datasheet

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

Digital Input Output Module for Zone 2 Series 9470/33

Isolators A3/1.

The transducer component converts the measured signal and displays the actual value.

Ultrasonic level meters ULM 70

Temperature Measurement

Remote I/O. 74 Remote I/O. Remote I/O System

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolators A3/1. Vibration Transducer Supply Unit Series

SITRANS T measuring instruments for temperature

SITRANS L Level instruments

Temperature Measurement

4/111. Overview. Benefits Greater flexibility Wide product program Uniform sensor interface enabling "plug & play" for all transmitters

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

IFC 100 / IFC 300. Electromagnetic flow converters for the OPTIFLUX series

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Flow Measurement SITRANS F US Inline

Positioner with HART Communication Type 3780

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Digital Input Output Module for Zone 1 Series 9470/32

SITRANS F C. Flowmeter SITRANS FC430 3/151. Technical specifications. Overview

Single-Channel Safety Barriers Series 9001

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Preset counters, electronic

Transcription:

Overview Design The transmitter is designed as either IP67 NEMA 4X enclosure for compact or wall mounting or 19" version as a 19 insert as a base to be used in: 19" rack systems Panel mounting IP65/NEMA 4 Back of panel mounting IP20/NEMA 2 Wall mounting IP66/NEMA 4 Several options on 19 versions are available such as: Transmitters mounted in safe area for Ex ATEX approved flow sensors (incl. barriers) Transmitters with electrode cleaning unit Transmitter MAG 5000/6000 compact version (left) and 19 insert version (right) The MAG 5000 and 6000 are microprocessor-based transmitters engineered for high performance, easy installation, commissioning and maintenance. The transmitters evaluate the signals from the SITRANS F M sensors type MAG 1100, MAG 1100 F, MAG 3100 and MAG 5100 W. Transmitter types: MAG 5000: Max. measuring error 0.5% of rate (incl. sensor) MAG 6000: Max. measuring error 0.25% of rate (incl. sensor, see also sensor specifications) and with additional features such as: Plug & Play insert bus modules; integrated batch functions. Benefits Superior signal resolution for optimum turn down ratio Digital signal processing with many possibilities Automatic reading of SENSORPROM data for easy commissioning User configurable operation menu with password protection. 3 lines, 20 characters display in 11 languages. Flow rate in various units Totalizer for forward, reverse and net flow as well as additional information available Multiple functional outputs for process control, minimum configuration with analogue, pulse/frequency and relay output (status, flow direction, limits) Comprehensive self-diagnostic for error indication and error logging (see under SITRANS F M diagnostics) Batch control Custody transfer approval: PTB, OIML R75, R117, OIML R 49 and MI-001, MAG 6000 with add-on bus modules for HART, FOUNDATION Fieldbus H1, DeviceNet, MODBUS RTU/RS485, PROFIBUS PA and DP Function The MAG 5000/6000 are microprocessor-based transmitters with a build-in alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic sensors and also fulfil the task of a power supply unit which provides the magnet coils with a constant current. Further information on connection, mode of operation and installation can be found in the data sheets for the sensors. Displays and controls Operation of the transmitter can be carried out using: Control and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication PC/laptop and SIMATIC PDM software using PROFIBUS or MODBUS communication Operating and display panel HART communication Master Transmitter HART- Communicator PROFIBUS DP + Coupling module PC/ Laptop RS-232 PROFIBUS PA Min. 230 W T Bus terminator Application The SITRANS F M flowmeters are suitable for measuring the flow of almost all electrically conductive liquids, pastes and slurries. The main applications can be found in: Water and waste water Chemical and pharmaceutical industries Food & beverage industries Power generation and utility Coupler with power supply PROFIBUS PA communication... Transmitter with PROFIBUS PA interface 11.020_UK - 1

Technical specifications Mode of operation and design Measuring principle Empty pipe Excitation frequency Electrode input impedance Input Digital input Activation time Current Output Current output Signal range Load Time constant Digital output Frequency Pulse (active) Pulse (passive) Time constant Relay output Time constant Load Low flow cut off Galvanic isolation Max. measuring error (incl. sensor and zero point) MAG 5000 MAG 6000 Rated operation conditions Ambient temperature Operation Storage Mechanical load Compact version Electromagnetic with pulsed constant field Detection of empty pipe (special cable required in remote mounted installation) Depend on sensor size > 1 x 10 14 Ω 11... 30 V DC, R i = 4.4 KΩ 50 ms I DC 11 V = 2.5 ma, I DC 30 V = 7 ma 0... 20 ma or 4... 20 ma < 800 Ω 0.1 30 s, adjustable 0... 10 khz, 50% duty cycle (uni/bidirectional) DC 24 V, 30 ma, 1KΩ R i 10 KΩ, short-circuitprotected (power supplied from flowmeter) DC 3 30 V, max. 110 ma, 200 Ω R i 10 KΩ (powered from connected equipment) 0.1 30 s, adjustable Changeover relay, same as current output 42 V AC/2 A, 24 V DC/1 A 0... 9.9% of maximum flow All inputs and outputs are galvanically isolated 0.5% of rate 0.25% of rate Display version: -20... +50 C (-4... +122 F) Blind version: -20... +60 C (-4... +140 F) -40... +70 C (-40... +158 F) 18... 1000 Hz, 3,17 G rms, sinusoidal in all directions to IEC 68-2-36 19 insert 1... 800 Hz, 1 G, sinusoidal in all directions to IEC 68-2-36 Degree of protection Compact version IP67/NEMA 4X to IEC 529 and DIN 40050 (1 mh 2 O 30 min.) 19 insert IP20/NEMA 2 to IEC 529 and DIN 40050 EMC performance Display and keypad Totalizer Display Time constant Design Enclosure material Compact version 19 -insert EN 61326-1 (all environments) EN 61326-2-5 Two eight-digit counters for forward, net or reverse flow Background illumination with alphanumeric text, 3 x 20 characters to indicate flow rate, totalized values, settings and faults; Reverse flow indicated by negative sign Time constant as current output time constant Fiber glass reinforced polyamide; optional (IP67 only): AISI 316 stainless steel Standard 19 insert of aluminium/steel (DIN 41494), width: 21 TE, height: 3 HE IP20/NEMA 2; Aluminium IP65/NEMA 4; ABS plastic IP66/NEMA 4; ABS plastic Back of panel Panel mounting Wall mounting Dimensional drawings Compact version See dimensional drawings 19 insert See dimensional drawings Weight Compact version 0.75 kg (2 lb) 19 insert See dimensional drawings Power supply 115... 230 V AC +10% -15%, 50... 60 Hz, 17 VA 11... 30 V DC or Power consumption 230 V AC: 17 VA 24 V AC : 9 W, I N = 380 ma, I ST =8A (30ms) 12 V DC : 11 W, I N = 920 ma, I ST = 4 A (250 ms) Certificates and approvals CE, ULc general purpose, C-tick; CSA/FM Class 1, div 2 Custody transfer approval (MAG 5000/6000 CT) Communication Standard MAG 5000 MAG 6000 Optional (MAG 6000 only) MAG 5000/6000 CT PTB OIML R49 (cold water pattern approval); MI-001 PTB and DANAK OIML R75 (hot water pattern approval) (MAG 6000 CT) PTB and DANAK OIML R117 (cold water/milk, beer etc. pattern approval) (MAG 6000 CT) Without serial communication or HART as option Prepared for client mounted addon modules HART, MODBUS RTU/RS485, FOUNDATION Fieldbus H1, DeviceNet, PROFIBUS PA, PROFIBUS DP as add-on modules no communication moduls approved 11.020_UK - 2

Safety barrier (e/ia) Electrode cleaning unit Cleaning unit Application For use with MAG 5000/6000 19 and MAG 1100 Ex ATEX/MAG 3100 Ex ATEX Ex approval MAG 1100 Ex [EEx e ia] IIB ATEX MAG 3100 Ex [EEx e ia] IIC ATEX Cable parameter Group Capacity in μf Inductance in mh Electrode IIC 4.1 80 IIB 45 87 IIA 45 87 Ambient temperature During operation -20... +50 C (-4... +122 F) During storage -20... +70 C (-4... +158 F) Enclosure Material Standard 19 insert in aluminium/steel (DIN 41494) Width 21 TE (4.75 ) Height 3 HE (5.25 ) Rating IP20 / NEMA 2 to EN 60529 and DIN 40050 Mechanical load 1 g, 1 800 Hz sinusoidal in all directions to EN 60068-2-36 EMC performance Emission EN 50081-1 (Light industry) Immunity EN 50082-2 (Industry) Application For use with transmitters MAG 5000 and 6000 19 to clean the electrodes on sensors MAG 1100 or MAG 3100 NB: Must not be used with intrinsically safe ATEX sensors NB: Not to be used with sensors with Hastelloy and Tantalum electrodes Cleaning voltage AC cleaning 60 V AC DC cleaning 30 V DC Cleaning period 60 s + 60 s pause period Relay Load 42 V/2 A Operation Switch relay activated when cleaning is in progress Automatic Yes Manual No Indicator lamps LEDs: ON and CLEANING Supply voltage and power 115 230 V AC, +10% -15%, 50 60 Hz, 7 VA cleaning, 5 VA stand by consumption 11 30 V DC / 11 24 V AC, 50 60 Hz, 7 VA cleaning, 5 VA stand by Ambient temperature During operation -20... +50 C (-4... +122 F) During storage -20... +70 C (-4... +158 F) Enclosure Material Standard 19 insert in aluminium/steel (DIN 41494) Width 21 TE (4.75 ) Height 3 HE (5.25 ) Rating IP20 / NEMA 2 to EN 60529 and DIN 40050 Mechanical load 1 g, 1 800 Hz sinusoidal in all directions to EN 60068-2-36 The Siemens cleaning unit can be used with MAG 5000 or 6000 in 19 insert version. The cleaning unit can be used in applications where the liner and subsequently the electrodes may be coated with deposits. If the coating is electrically insulating, the electrode signal will be reduced. If the coating is electrically inductive, the electrode signal will be partly short-circuited and in both cases the accuracy of the meter will decrease (dependent on coating type and thickness). Note: The cleaning unit cannot be used for inflammable or explosive media! 11.020_UK - 3

Siemens AG 2008 Mode of operation The cleaning unit cleans the electrodes electro-chemically by applying a voltage to the electrodes for approx. 60 seconds. While cleaning, the transmitter stores and holds the latest measured flow reading on the display and also the signal outputs. After an additional pausing period of 60 seconds the flowmeter resumes normal measurement and the cleaning is now completed. The relay in the transmitter activates the cleaning cycle. In the relay output menu (under cleaning) the cleaning interval can be set between 1 hour and 24 hours. Cleaning should only take place with liquid in the pipe.this can be detected via the empty pipe function. It is therefore recommended to select empty pipe detection ON when using the cleaning. The cleaning sequence can also be controlled manually through the electrical input of the transmitter. Before this is done, ensure that the measuring pipe is full. AC cleaning i 80 ma AC-cleaning is used to remove fatty deposits on the electrodes. These fatty deposits are seen in waste water applications, in abattoirs and water applications with oil residuals. During the cleaning process, the surface of the electrodes get warmer, which tends to soften grease particles and the gas bubbles generated mechanically lift deposits away from the surface of the electrodes. Note: Do not use AC-cleaning on sensors with Tantalum or Hastelloy electrodes. DC cleaning i 20 ma DC-cleaning is used to eliminate electrically conductive deposits in the measuring pipe influencing the measuring accuracy. Particularly in district heating applications an electrically conductive deposit (magnetite) may occur and short-circuit the electrode signal. In this case the accuracy of the meter decreases and the signal/noise conditions of the meter become inferior. The problem only arises if the conductivity of the water is less than approx. 250 μs/cm. During DC-cleaning electrolysis takes place where the flow of electrons removes the particle deposits from the electrode area. Note: Do not use DC-cleaning on sensors with Tantalum or Hastelloy electrodes. 11.020_UK - 4

Selection and Ordering Data Transmitter MAG 5000 Transmitter MAG 5000 Blind for compact and wall mounting; IP67/NEMA 4X, fibreglass reinforced polyamide Transmitter MAG 5000 Display for compact and wall mounting; IP67/NEMA 4X, fibre-glass reinforced polyamide, with HART Transmitter MAG 5000 CT for compact and wall mounting, approved for custody transfer; IP67/NEMA 4X, fibre-glass reinforced polyamide Transmitter MAG 6000 Transmitter MAG 6000 Blind for compact and wall mounting; IP67/NEMA 4X, fibre-glass reinforced polyamide IP67/NEMA 4X, AISI 316 stainless steel (only for sensor with SS terminal box ) 1AA30-0AA0 1AA10-0AA0 } 1AA30-1AA0 } 1AA10-1AA0 1AA10-1BA0 1AA30-1AB0 1AA10-1AB0 Transmitter MAG 5000 for 19 rack and wall mounting 2CA30-1AA0 2CA10-1AA0 1AA30-0AA0 1AA10-0AA0 Transmitter MAG 6000 for compact and wall mounting; 1AA30-1AA0 1AA10-1AA0 1QA30-1AA0 1QA10-1AA0 Transmitter MAG 6000 CT for compact and wall mounting, approved for custody transfer (no communication moduls possible); IP67/NEMA 4X, fibre-glass reinforced polyamide Transmitter MAG 6000 SV for compact and wall mounting; special excitation 44 Hz settings for Batch application DN 25/1 IP67/NEMA 4X, fibre-glass reinforced polyamide 11... 30 V DC / 1AA30-1AB0 1AA10-1AB0 1AB30-1AA0 115/230 V AC, 50/60 Hz 1AB10-1AA0 Transmitter MAG 6000 for 19 rack and wall mounting Transmitter MAG 6000 SV for 19 rack and wall mounting; special excitation 44 Hz settings for Batch application DN 25/1 MAG 6000 with IP66/NEMA 4X enclosure; 115/230 V AC, 50/60 Hz MAG 6000 with electrode cleaning unit, complete mounted with IP66/NEMA 4X mounting enclosure MAG 6000 with safety barrier for ATEX 2G D approved sensors, complete mounted with IP66/NEMA 4X wall mounting enclosure, ATEX, 115/230 V AC, 50/60 Hz For ATEX 2G D sensors MAG 6000 SV, 19 insert, in IP66/NEMA 4X, ABS plastic enclosure, excitation frequency 44 Hz for Batch application DN 25/1, 11 30 V DC, 11 24 V AC, 50/60 Hz 2CA30-1AA0 2CA10-1AA0 2CB30-1AA0 2CB10-1AA0 2EA10-1AA0 2PA30-1AA0 2PA10-1AA0 2MA11-1AA0 2EB30-1AA0 } Available ex stock 11.020_UK - 5

Communication modules for MAG 6000 HART (not for MAG 6000 I) MODBUS RTU/RS485 PROFIBUS PA Profile 3 PROFIBUS DP Profile 3 DeviceNet FOUNDATION Fieldbus H1 } FDK-085U0226 } FDK-085U0234 } FDK-085U0236 } FDK-085U0237 } FDK-085U0229 } A5E02054250 Cable glands, for above cable, 2 pcs. M20 ½ NPT Sealing screws for sensor/ transmitter, 2 pcs A5E00822490 A5E00822501 FDK-085U0221 ½ NPT M20 Accessories for MAG 5000 and MAG 6000 Wall mounting unit for IP67/NEMA 4X version, wall bracket, terminal box in polyamide 4 x M20 cable glands } FDK-085U1018 4 x ½ NPT cable glands } FDK-085U1053 Cable for standard electrode or coil, 3 x 1.5 mm² / 18 gage with shield PVC 10 m (33 ft) } FDK-083F0121 20 m (65 ft) } FDK-083F0210 40 m (130 ft) } FDK-083F0211 60 m (200 ft) } FDK-083F0212 100 m (330 ft) FDK-083F0213 150 m (500 ft) FDK-083F3052 200 m (650 ft) FDK-083F3053 500 m (1650 ft) FDK-083F3054 Electrode cable for empty pipe or low conductivity, double shielded, 3 x 0.25 mm² 10 m (33 ft) FDK-083F3020 D) 20 m (65 ft) } FDK-083F3095 D) 40 m (131 ft) FDK-083F3094 D) 60 m (200 ft) FDK-083F3093 D) 100 m (330 ft) FDK-083F3092 D) 150 m (500 ft) FDK-083F3056 D) 200 m (650 ft) FDK-083F3057 D) 500 m (1650 ft) FDK-083F3058 D) Cable kit with standard coil cable, 3 x 1.5 mm²/18 gage with shield PVC and electrode cable double shielded, 3 x 0.25 mm² 10 m (33 ft) A5E01181647 F) 20 m (65 ft) A5E01181656 F) 40 m (130 ft) A5E01181686 F) 60 m (200 ft) A5E01181689 F) 100 m (330 ft) A5E01181691 F) 150 m (500 ft) A5E01181699 F) 200 m (650 ft) A5E01181703 F) 500 m (1640 ft) A5E01181705 F) Terminal box, in polyamide, inclusive lid M20 ½" NPT Terminal box lid, in polyamid Terminal box for MAG 6000, in stainless steel, inclusive lid M20 ½" NPT Terminal box (3A) for MAG 1100 Food in polyamide, inclusive lid M20 ½" NPT Potting kit for terminal box of MAG sensors for IP68/NEMA 6P (not ATEX) 19 cleaning unit for electrode cleaning (21TE) incl. back plate 115... 230 V AC, 50/60 Hz 19 safety barrier (21 TE) [EEx e ia] IIC for MAG 1100 ATEX and MAG 3100 ATEX, incl. back plate Panel mounting enclosure for 19 insert (21 TE); IP65/NEMA 4 enclosure in ABS plastic for front panel mounting Panel mounting enclosure for 19 insert (42 TE); IP65/NEMA 4 enclosure in ABS plastic for front panel mounting Back of panel mounting enclosure for 19 insert (21 TE); IP20/NEMA 2 enclosure in aluminium } FDK-085U1050 FDK-085U1052 FDK-085U1003 A5E00836867 A5E00836868 A5E00822478 A5E00822479 } FDK-085U0220 FDK-083F5039 FDK-083F5036 FDK-083F5034 FDK-083F5030 FDK-083F5031 FDK-083F5032 } Available ex stock D) Subject to export regulations AL: N, ECCN: EAR99H. F) Subject to export regulations AL: 9I999, ECCN: N. 11.020_UK - 6

Back of panel mounting enclosure for 19 insert (42 TE); IP20/NEMA 2 enclosure in aluminium FDK-083F5033 IP66/NEMA 4, wall mounting enclosure for 19 inserts (without backplates) 21 TE FDK-083F5037 Spare parts Connection plate 12... 24 V 115... 230 V 19 enclosure, 12... 24 V, 115... 230 V Connection plate for standard 19 transmitter FDK-083F4149 FDK-083F4148 FDK-083F4117 42 TE } FDK-083F5038 Front cover (7TE) } Available ex stock FDK-083F4525 Back plates (if wall enclosure IP66 is used as part) Wall unit enclosure IP66, 12... 24 V, 115... 230 V Transmitter FDK-083F4121 Transmitter ia/e and safety barrier Transmitter ia/ib and safety barrier (only for sensors produced before October 2007) Transmitter and cleaning unit FDK-083F4122 FDK-083F4120 FDK-083F4124 Connection plate for transmitter ia and safety barrier Connection plate for transmitter ia/ib and safety barrier (only for sensors produced before October 2007) Connection plate for transmitter and cleaning unit SENSORPROM memory unit (Sensor code and serial numbers must be specified on order) 2 kb (for MAG 5000/6000/ MAG 6000 I) 250 B (for MAG 2500/3000) Display unit for MAG 5000/6000 black neutral front FDK-083F4118 FDK-083F4119 FDK-083F4123 FDK-085U1005 FDK-085U1008 FDK-085U1038 Siemens front FDK-085U1039 Sun Shields for MAG 5000/6000 transmitters Sun shield for remote A5E01209496 MAG 5000/6000 transmitters Sun Shield for compact MAG 5000/6000 transmitters on MAG 3100 (DN 15... 2000 (½"... 78") or MAG 5100 (DN 150... 1200 (6"... 48") A5E01209500 11.020_UK - 7

Siemens AG 2008 Dimensional drawings Transmitter IP67/NEMA 4X compact polyamide 155 (6.10) 6 (0.24) 131 (5.16) 178 (7.01) Transmitter compact mounted Transmitter, 19 IP20/ NEMA 2 standard unit Transmitter wall mounted 11.020_UK - 8

Siemens AG 2008 Transmitter, wall mounting IP66/NEMA 4, 21 TE 210 (8.27) 235 (9.25) 90 (3.54) 90 (3.54) 22 (0.86) 13(0.51) 120 (4.72) 146 (5.75) 13 (0.51) 192 (7.56) Weight excl. transmitter: 2.3 kg (5.0 lbs) Transmitter, wall mounting IP66/NEMA 4, 42 TE 13 (0.51) 90 (3.54) 120 (4.72) 13 (0.51) 357 (14.05) 339 (13.35) Weight excl. transmitter: 2.9 kg (7.0 lbs) 22 (0.87) 90 (3.54) 146 (5.75) 235 (9.25) 11.020_UK - 9

Siemens AG 2008 Transmitter, panel front IP65/NEMA 4, 21 TE 197 (7.75) 144 (5.67) 184 (7.24) 198 (7.80) 50 (1.97) 140 (5.51) Weight excl. transmitter: 1.2 kg (2.7 lbs) 185 (7.28) Transmitter, panel front IP65/NEMA 4, 42 TE 294 (1.57) 144 (5.67) 281 (1.06) 198 (7.80) 50 (1.97) 140 (5.51) Weight excl. transmitter: 1.6 kg (3.5 lbs) 282 (1.10) 11.020_UK - 10

Transmitter, back of panel IP20/NEMA 2, 21 TE 163 (6.42) 144 (5.67) 218 (8.58) 132 (5.20) 57 (2.24) Weight: 0.7 kg (1.6 lbs) Transmitter, back of panel IP20/NEMA 2, 42 TE 269 (10.59) 253 (9.96) 218 (8.58) 132 (5.20) 57 (2.24) Weight: 0.9 kg (2.0 lbs) 11.020_UK - 11

Siemens AG 2008 Schematics Electrical connection Grounding PE must be connected due to safety class 1 power supply. Mechanical counters When mounting a mechanical counter to terminals 57 and 58 (active output), a 1000 μf capacitor must be connected to the terminals 56 and 58. Capacitor + is connected to terminal 56 and capacitor - to terminal 58. Output cables If the output cable length is long in noisy environment, we recommend to use screened cable. 1) Shield 1) Note Special cable with individual wire shields (shown as dotted lines) are only required when using empty pipe function or long cables Telephone +46 10 455 97 00 sales@axel-larsson.se www.axel-larsson.se STOCKHOLM GÖTEBORG MOTALA KARLSTAD FALUN SKELLEFTEÅ 11.020_UK - 12 Head Office: Truckvägen 12, P.O. Box 805, SE-194 28 Upplands Väsby (Stockholm), Sweden. Design and specifications subject to change without prior notice.