PV Powered Direct Torque Controlled Induction Motor without AC Phase Current Sensors

Similar documents
Experimental Investigations on PV Powered SVM-DTC Induction Motor without AC Phase Current Sensors

International Journal of Engineering Science Invention Research & Development; Vol. II Issue VIII February e-issn:

Finite Step Model Predictive Control Based Asymmetrical Source Inverter with MPPT Technique

CHAPTER-3 Design Aspects of DC-DC Boost Converter in Solar PV System by MPPT Algorithm

Parallel or Standalone Operation of Photovoltaic Cell with MPPT to DC Load

PERFORMANCE EVALUATION OF THREE PHASE SCALAR CONTROLLED PWM RECTIFIER USING DIFFERENT CARRIER AND MODULATING SIGNAL

Solar fed Induction Motor Drive with TIBC Converter and Voltage Multiplier Circuit

A Comparative Study of Sinusoidal PWM and Space Vector PWM of a Vector Controlled BLDC Motor

Simulation of Speed Control of Induction Motor with DTC Scheme Patel Divyaben Lalitbhai 1 Prof. C. A. Patel 2 Mr. B. R. Nanecha 3

Simulation and Experimental Based Four Switch Three Phase Inverter Fed Induction Motor Drive

A Switched Boost Inverter Fed Three Phase Induction Motor Drive

A High Efficiency and High Voltage Gain DC-DC Converter for Renewable Energy Connected to Induction Motor

POWER ISIPO 29 ISIPO 27

CHAPTER 4 DESIGN OF CUK CONVERTER-BASED MPPT SYSTEM WITH VARIOUS CONTROL METHODS

CHAPTER 2 CURRENT SOURCE INVERTER FOR IM CONTROL

Control of Induction Motor Fed with Inverter Using Direct Torque Control - Space Vector Modulation Technique

Digital Control of Permanent Magnet Synchronous Motor

Proposed System Model and Simulation for Three Phase Induction Motor Operation with Single PV Panel

Application of Model Predictive Control in PV-STATCOM for Achieving Faster Response

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

CHAPTER 3 MAXIMUM POWER TRANSFER THEOREM BASED MPPT FOR STANDALONE PV SYSTEM

Comparative Study of P&O and InC MPPT Algorithms

VIENNA RECTIFIER FED BLDC MOTOR

A VARIABLE SPEED PFC CONVERTER FOR BRUSHLESS SRM DRIVE

CHAPTER 3 CUK CONVERTER BASED MPPT SYSTEM USING ADAPTIVE PAO ALGORITHM

CHAPTER 3 APPLICATION OF THE CIRCUIT MODEL FOR PHOTOVOLTAIC ENERGY CONVERSION SYSTEM

Sensorless Control of BLDC Motor Drive Fed by Isolated DC-DC Converter

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Seshankar.N.B, Nelson Babu.P, Ganesan.U. Department of Electrical & Electronics Engineering, Valliammai Engineering College, Kattankulathur, Chennai

Voltage-MPPT Controller Design of Photovolatic Array System Using Fuzzy Logic Controller

Harmonic Analysis of 1.5 kw Photovoltaic System in the Utility Grid

Modeling of PV Interconnected Distribution System using Simulink

In this lab you will build a photovoltaic controller that controls a single panel and optimizes its operating point driving a resistive load.

International Journal of Advance Engineering and Research Development

Maximum Power Point Tracking Using Ripple Correlation and Incremental Conductance

Comparative study of maximum power point tracking methods for photovoltaic system

CHAPTER 2 A SERIES PARALLEL RESONANT CONVERTER WITH OPEN LOOP CONTROL

EEE, St Peter s University, India 2 EEE, Vel s University, India

A Novel 2 - Stage Power Conditioning System for PV Power Generation Using FPGA

Vienna Rectifier Fed BLDC Motor

Modeling & Simulation of PMSM Drives with Fuzzy Logic Controller

Performance Enhancement of Sensorless Control of Z-Source Inverter Fed BLDC Motor

Speed control of Induction Motor Using Push- Pull Converter and Three Phase SVPWM Inverter

Power Factor Improvement with Single Phase Diode Rectifier in Interior Permanent Magnet Motor

Photovoltaic Systems Engineering

Modelling and Simulation of New PV-Battery Based Hybrid Energy System for Z source Inverter using SVPWM fed Industrial Applications

A Current Sensor-less Maximum Power Point Tracking Method for PV

Soft Switching with Cascaded Transformers to Drive the PMDC Motor

An Interleaved High Step-Up Boost Converter With Voltage Multiplier Module for Renewable Energy System

Multilevel Inverter for Grid-Connected PV SystemEmploying MPPT and PI Controller

Performance Analysis of a Solar Powered BLDC Motor

Inductance Based Sensorless Control of Switched Reluctance Motor

Simulation of Solar Powered PMBLDC Motor Drive

Photovoltaic Systems I EE 446/646

Speed Control of Induction Motor using Predictive Current Control and SVPWM

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Sliding Mode Control based Maximum Power Point Tracking of PV System

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

Keywords - Induction motor, space vector PWM, DTC, sensorless control, reconstruction.

DESIGN OF A VOLTAGE-CONTROLLED PFC CUK CONVERTER-BASED PMBLDCM DRIVE for FAN

HIGH STEP UP CONVERTER FOR SOLAR POWER USING FLC

Enhanced MPPT Technique For DC-DC Luo Converter Using Model Predictive Control For Photovoltaic Systems

INCREMENTAL CONDUCTANCE METHOD BASED MPPT APPLIED TO NOVEL DC DC CONVERTER FOR HIGH POWER APPLICATIONS

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters

Design And Analysis Of Dc-Dc Converter For Photovoltaic (PV) Applications.

PWM Generation using PIC16F877A for Bidirectional V/F control of Single-Phase Induction Motors

IN MANY industrial applications, ac machines are preferable

Efficiency Optimized Brushless DC Motor Drive. based on Input Current Harmonic Elimination

A Three Phase Power Conversion Based on Single Phase and PV System Using Cockcraft-Walton Voltage

CHAPTER 3 VOLTAGE SOURCE INVERTER (VSI)

CHAPTER 3 SINGLE SOURCE MULTILEVEL INVERTER

Grid Connected Photovoltaic Micro Inverter System using Repetitive Current Control and MPPT for Full and Half Bridge Converters

Resonant Converter Forreduction of Voltage Imbalance in a PMDC Motor

OPTIMAL DIGITAL CONTROL APPROACH FOR MPPT IN PV SYSTEM

Simulation of Standalone PV System Using P&O MPPT Technique in Matlab/Simulink

Speed Control of BLDC Motor Using FPGA

Analysis of an Economical BLDC Drive System

B.Tech Academic Projects EEE (Simulation)

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

Chapter-4. Fixed and Variable Step-Size Perturb Voltage MPPT Control for Photovoltaic System

Comparison Of DC-DC Boost Converters Using SIMULINK

Renewable Energy Based Interleaved Boost Converter

Boost Half Bridge Converter with ANN Based MPPT

FUZZY LOGIC BASED DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR

An Interleaved High-Power Fly back Inverter for Photovoltaic Applications

CHAPTER-5 DESIGN OF DIRECT TORQUE CONTROLLED INDUCTION MOTOR DRIVE

Modeling and Simulation of Cascaded Multilevel Inverter fed PMSM Drive with PV Stand-Alone Water Pumping System

Closed Loop Control of Three-Phase Induction Motor using Xilinx

A Three Phase Seven Level Inverter for Grid Connected Photovoltaic System by Employing PID Controller

Perturb and Observe Method MATLAB Simulink and Design of PV System Using Buck Boost Converter

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

Low Cost Power Converter with Improved Performance for Switched Reluctance Motor Drives

A New Active Soft Switching Technique for Pulse Width Modulated Full Bridge DC-DC Converters

Design and Analysis of Push-pull Converter for Standalone Solar PV System with Modified Incrementalconductance MPPT Algorithm

DESIGN AND IMPLEMENTATION OF SOLAR POWERED WATER PUMPING SYSTEM

CHAPTER 3 MODELLING OF PV SOLAR FARM AS STATCOM

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Transcription:

PV Powered Direct Torque Controlled Induction Motor without AC Phase Current Sensors Muthamizhan.T 1, Ramesh R 2 Teaching Fellow, Dept. of EEE, CEG, Anna University, Chennai 600025, Tamilnadu, India 1 Associate Professor, Dept. of EEE, CEG, Anna University, Chennai 600025, Tamilnadu, India 2 ABSTRACT: The paper presents a low-cost, phase-current reconstruction algorithm for direct torque control threephase induction motor using the information obtained from only one shunt resistor which is in series with low side switches in a conventional three-phase inverter. The aim is to develop a low-cost high- performance induction motor drive. It uses the dc current to reconstruct the stator currents needed to estimate the motor flux and the electromagnetic torque. Photovoltaic arrays convert solar energy to dc electric power; uses chopper and dc-ac inverter to fed three phase Induction Motor. The chopper used here is current fed full bridge boost dc-dc converter, which is preferred and extensively used in high voltage applications and advantageous over voltage fed converters. The inverter switches are controlled by PWM techniques obtained from SVM-DTC of IM. Simulation results are given to prove the ability of the proposed scheme of reproducing the performances of a SVM- DTC IM drive. KEYWORDS:Photovoltaic systems, Zero current switching, Induction motors, Space vector pulse width modulation, Direct torque control. I.INTRODUCTION The induction motor stands dominant in both industrial and domestic applications.the aim is to develop a low-cost high-performance Space Vector Modulated Direct Torque Controlled (SVM-DTC) Induction Motor drive as shown in Fig. 1. A low-cost and simple phase-current reconstruction algorithm for three-phase IM under DTC uses dc-link current, dc-link voltage and the voltages applied to the inverters switches of the conventional three-phase inverter. The shunt resistor in series with low side switches are used to draw the dc-link current of a three-phase inverter, the cost of which is less compared to a hall sensor to measure the stator current. The proposed algorithm is robust and very simple and uses the dc-link current to reconstruct the stator currents needed to estimate the motor flux and the electromagnetic torque. The photovoltaic (PV) energy is the most abundant, which is capable of providing the energy needs and having the advantage of photovoltaic pump-storage system. In this system, the use of large banks of batteries is avoided, which are expensive and have one-fifth of the lifetime of a PV panel. The PV characteristics and the issue of maximum power point tracking (MPPT) applied to the induction motor control have been addressed in different ways in the literature [1] - [5]. The fixed frequency phase-shift control enables the implementation of ZCS for all converter switches. Currentfed zero-voltage transition PWM converter use auxiliary network and hence all the power switches are zero-voltage switched or zero-current switched [6], [7]. The space vector pulse width modulation (SVPWM) method and direct torque control techniques for variable frequency drive applications have superior performance characteristics, it has been finding widespread application in recent years [8] - [12]. Sensor less space vector pulse width modulated direct torque controlled induction motor drive utilizing modified stator flux estimation logic has been proposed in literature [13] - [15]. A typical configuration of a batteryless photovoltaic pumping system comprises the following components: photovoltaic panels, MPPT system, current fed full-bridge boost dc-dc converter, dc-ac inverter, three phase induction motor with a closed loop controller. The aim of MPPT is to normalize the real output voltage of PV panel to the voltage at Maximum Power Point. Hence the MPPT adjusts the output power of solar panel. If the PV output voltage is higher than MPP voltage, then transferred power to the load or network is increased, otherwise, it is decreased.current fed converters are preferred and extensively used in high voltage applications since it is advantageous than the voltage fed Copyright to IJAREEIE www.ijareeie.com 255

converters. A very high turns ratio transformer is used to achieve a high output voltage in high voltage applications. The SVM-DTC scheme of an induction motor under varying dynamic conditions, is used to adjust the bandwidth of the torque hysteresis controller to reduce the torque and flux ripples and hence, to improve motor dynamic response. II.PHOTOVOLTAICS The conversion of solar energy into electricity using solar cells system is the valuable way of producing the alternative energy. One of the most promising applications of photovoltaic energy is pumping. However, the absence of batteries does not compromise the efficiency of the power conversion chain. Fig. 2 shows the equivalent circuit of the solar cell.the V-I characteristic of a single-junction P-N under illumination can be written as follows: q( V IRS ) I I I0 exp 1 (1) L nkt Where the net current is the difference of photocurrent and diode current, V is the voltage, T is the absolute temperature and R S is the series resistance inside each cell in connection between the cells. The shunt resistance R sh is neglected. A single shunt diode was used with the diode quality factor set to achieve the best curve match. Fig. 1 Block diagram of induction motor with phase current re-construction algorithm Solar cells are usually connected in series, in the modules, creating an additive voltage and in parallel to yield higher amperage. Modules are then interconnected, in series and parallel to create the desired peak dc voltage and current. Fig. 2 Equivalent circuit of the solar cell The Hill Climbing MPPT algorithm perturbs the voltage in one direction and evaluates the corresponding difference (sign) of the power. If the power is increasing, the algorithm will move the voltage in the same direction; otherwise, it will reverse the direction. The Hill Climbing algorithm can be confused, and track the MPP in the wrong direction, in case of rapidly changing atmospheric conditions, when the change in PV power caused by change in irradiance is larger than the change in PV power as a function of the perturbation. The Hill Climbing will not be confused, if and only if ΔP u > ΔP g (2) Copyright to IJAREEIE www.ijareeie.com 256

where ΔP u is the change in power as function of change in voltage, and ΔP g is the change in power as function of change in irradiance. The hill climbing MPPT is optimized in respect with the sampling interval (Ta) and minimum step size (ΔV d ) in order to follow a certain irradiance ramp (dg/dt). The approach is based on a second-order Taylor approximation of the PV model including resistive parts. Fig. 3 shows the V-I characteristics of the 1 kw solar array and Fig. 4 shows the P-V characteristics of the 1 kw solar array. If operating point of load is on the left of MPP, in other words if the module works as a current source, the error signal can be written as P V module module 0 M M M In the opposite case, PV module acts as a voltage source, and error signal (M) is calculated as Pmodule 0 M M M Vmodule At Maximum power point, error will be zero and expression is written as follows: P V module module 0 M M or M 0 (5) It is proved that the Hill Climbing algorithm is the one of the best method to extract the maximum power and hence this paper uses hill climbing algorithm to extract the maximum power. (3) (4) Fig. 3 V-I Characteristics of 1KW solar array Fig. 4 P - V Characteristics of 1KW solar array III.CURRENT FED FULL-BRIDGE BOOST DC-DC CONVERTER Current fed converters shown in Fig.5, are preferred and extensively used in high voltage applications since it is advantageous than the voltage fed converters. A very high turns ratio transformer is used to achieve a high output voltage in high voltage applications. The disadvantage of using large turns ratio transformer is the parasitic components (parasitic capacitance and leakage inductance) generate high voltage and current spikes, results in switching losses in the power devices, which has been overcome by Zero Current Switching (ZCS) operation. Constant on-time control methodology is utilized to achieve ZCS and a variable frequency control scheme is used to regulate the output voltage.in order to decrease the volume and weight of the dc-dc converter, higher switching frequency is chosen. Increasing switching frequency leads to increased switching losses which in turns reduces converters efficiency. Soft switching techniques are used in PWM dc-dc converters to reduce switching losses and Electro Magnetic Interference (EMI). Soft-switching of the dc-dc converter have either turn-on or turn-off switching losses in a power switches are eliminated. Soft switching in current fed full-bridge boost dc-dc converter has been achieved by Zero current Switching (ZCS)technique in high frequency applications using IGBT switches in the dc-dc converter. Copyright to IJAREEIE www.ijareeie.com 257

Fig. 5 Current fed full-bridge boost dc-dc converter. The dc-dc converter utilizes the leakage inductance and the parasitic capacitance of the high-voltage transformer in order to achieve the ZCS operation. The switch can be implemented by an IGBT in series with a reverse blocking diode, an IGBT with reverse voltage blocking capability. The current and voltage during the turning on and off of the switch is shown in Fig. 6 and the power loss of the switching component is 0.3W to 1W by ZCS.The current fed full bridge boost dc-dc converter yields an output voltage of 600 V while the solar panel input voltage is (120-180)V, the current is continuous and the converter driven near resonance.the switching pattern applied to the switches of the full bridge, utilizing the leakage inductance and the parasitic capacitance of the high-frequency transformer to achieve the ZCS operation across the switches. Fig. 7 shows the voltages at the input and output side of the high frequency transformer of turns ratio 1:4.The transformer output is connected to the diode bridge rectifier and the ripple is filtered with a bulk capacitor of value 2200 μf. The output voltage, current and power of the dc-dc converter is plotted in the Fig. 8. Fig. 6 Current, voltage and power loss across the switch during ZCS of the dc-dc converter Fig. 7 Transformer input and output voltage of the dc-dc converter Fig. 8 Output voltage, current and power waveform of the dc-dc converter Copyright to IJAREEIE www.ijareeie.com 258

IV.SVM - DTC OF INDUCTION MOTOR The phase currents are estimated by the dc-link current measurement processes. The phase voltages and currents required in the classical direct torque controller is reconstructed using the dc-link voltage and dc-link current, instead of the stator phase voltages sensed from induction motor using hall sensors.the stator flux vector and the electromagnetic torque are directly calculated from the voltage and the current derived from a single dc-link voltage sensor from a voltage divider network and a single dc-link current sensor by using a shunt resistor.this algorithm does not require additional computation burden or other motor parameter knowledge. The simulation of the low cost direct torque controlled induction motor is done using MATLAB/SIMULINK simulation software. The solar panel output is fed to current fed full bridge boost dc-dc converter. The dc output voltage is filtered with a bulk capacitor and the dc voltage is given as input to the three phase inverter connected to the three phase induction motor. Here PI controller is used to tune the speed error which is used to generate the torque reference signal. Classical controllers with limitations have been used to control induction machines in achieving desired dynamic response. One modification of the basic DTC is used for estimating the three-phase currents from a single dc-link current sensor. On the modification, the need of an additional current sensor requirement is minimized. The six voltage vector is applied at each cycle period, for prefixed time intervals for the Space Vector Modulation (SVM) technique. TABLE I DTC SWITCHING TABLE Sector 1 2 3 4 5 6 c ɽ = -1 V 2 V 3 V 4 V 5 V 6 V 1 C Ø = -1 c ɽ = 0 V 7 V 0 V 7 V 0 V 7 V 0 c ɽ = +1 V 6 V 1 V 2 V 3 V 4 V 5 c ɽ = -1 V 3 V 4 V 5 V 6 V 1 V 2 C Ø = +1 c ɽ = 0 V 0 V 7 V 0 V 7 V 0 V 7 c ɽ = +1 V 5 V 6 V 1 V 2 V 3 V 4 By using this modulation strategy, the voltage vectors are synthesized with respect to those used in the basic DTC technique from 30 to 30. The DTC switching table is tabulated in Table I. The PWMgenerated by the space vector pulse width modulation techniques for the classical DTC is as shown in the Fig. 9. The output voltage for various switching patterns can be obtained by considering an example of Space voltage V 6 (state 101); the output voltages V an, V bn and V cn are obtained by the equivalent circuit as shown in Fig. 10.The phase voltages and currents are reconstructed using the dc-link voltage, dc-link current and the voltages applied to the switches. The phase voltages and phase currents of the stator of three phase inductor motor are reconstructed and the simulated waveforms are given in the Fig.11. Fig. 9 Pulse generated in the SVPWM-Classical DTC IM Fig. 10 Equivalent circuit to find V an, V bn and V cn Copyright to IJAREEIE www.ijareeie.com 259

TABLE II SUMMARY OF INVERTER SWITCHING STATES Name C B A V an V bn V cn V 0 0 0 0 0 0 0 V 1 0 0 1 2V dc / 3 -V dc / 3 -V dc / 3 V 2 0 1 0 V dc / 3 V dc / 3-2V dc / 3 V 3 0 1 1 -V dc / 3 2V dc / 3 -V dc / 3 V 4 1 0 0-2V dc / 3 V dc / 3 V dc / 3 V 5 1 0 1 -V dc / 3 -V dc / 3 2V dc / 3 V 6 1 1 0 V dc / 3-2V dc / 3 V dc / 3 V 7 1 1 1 0 0 0 The output voltages V an, V bn and V cn can be calculated using the Equation 3.18 and are given as follows: Z eq V V an bn 3Z 2 (6) V cn - V dc V dc z 2 z 3 2 V 3 dc z - 2Vdc. z 3 (8) 2 3 where V dc is the dc link voltage. Similarly we can calculate the values of V an, V bn and V cn for the other five nonzero states. V 0 and V 1 are the zero states of the space voltage. The inverter switching states is tabulated in Table II and the parameters of the induction motor are tabulated in Table III. (7) Fig. 11Calculated phase current and phase voltage waveforms Fig. 12 Stator currents vs time characteristics of classical DTC IM Copyright to IJAREEIE www.ijareeie.com 260

Fig. 13 Rotor currents vs time characteristics of classical DTC IM Fig. 14 Ø d, Ø q vs time characteristics of classical DTC IM Fig. 15 Flux, flux angle vs time characteristics of classical DTC IM Fig. 16 Speed and torque response curve of classical DTC IM Fig. 17 Stator flux locus using classical DTC Fig.12 and Fig.13 shows the stator and rotor current measured in the classical direct torque controlled induction motor respectively using MATLAB/SIMULINK software.fig. 14 measures the direct and quadrature axis component of the flux, Ø d and Ø q, and Fig. 17 shows the Stator flux locus of the space vector modulated classical DTC IM.Fig. 15 shows the measured total flux Ø, flux angle θ and Fig. 16 shows the speed characteristics of the classical DTC IM using SVM TABLE III PARAMETERS OF THE INDUCTION MOTOR Parameters Ratings Rated power 1 HP Rated voltage 415V Rated speed 1440 RPM Pole pairs 2 Stator resistance 8.35 Ω Rotor resistance 8.43 Ω Stator leakage inductance 32 mh Rotor leakage inductance 32 mh Air gap inductance 0.601 H Rotor time constant (J) 0.0051Kg.m 2 Friction factor(f) 0.06 Nm.s Copyright to IJAREEIE www.ijareeie.com 261

The speed of the induction motor is set at 600 RPM, 1100RPM and 1400 RPM respectively at 0s, 0.22s and 0.4s. At 600 RPM, the motor speed reaches in 0.065s but settles down 600 RPM at 0.075s. At 0.22s when the reference speed is set to 1100 RPM the motor speed starts to follows the speed from 1100 RPM in 0.026s with a little overshoot. At 0.4s the speed is set to 1400RPM and the motor speed follows reach the set speed at 0.465s.Fig. 16 also shows the electromagnetic torque Vs time curve, where the torque settles down at 5 Nm finally with a ripple of 2 Nm but the transient response of the electromagnetic torque curve has more ripple. Direct torque control technique are used by many researchers because of it finds extensive applications with various ac machine types such as induction motor, PMSM, PM Brushless, and Reluctance motor. V. CONCLUSION A low-cost, phase-current reconstruction algorithm for a PV powered space vector modulated- direct torque controlled three-phase induction motor was proposed in this paper. The number of sensor in the induction motor drive is reduced by using phase-current reconstruction algorithm. The maximum dc power can be obtained from the PV array by utilizing the HILL CLIMBING algorithm. The advantage of using current fed full bridge boost dc-dc converter here is that all of the parasitic capacitances and inductances are included in the resonant or filter circuits and the system does not generate parasitic oscillations and the output is without any uncontrolled high voltage and current spikes.the conclusion is that the whole performance of the system is improved compared to a vector control of induction motor. The settling time of the speed and ripples present in the torque are reduced hence DTC method are preferred than vector control REFERENCES [1] S.B. Kjaer, Evaluation of the Hill Climbing and the Incremental Conductance, Maximum Power Point Trackers for Photovoltaic Power System, IEEE Transactions on Energy Conversion, vol. 27, no. 4, pp. 922-929 2012. [2] T. Esram and P. L. Chapman, Comparison of Photovoltaic Array Maximum Power Point Tracking Technique, IEEE Transactions on Energy Conversion, vol. 22, no. 2, pp. 439-449, 2007. [3] M.A. Vitorino, M.B. de Rossiter Correa, C.B. Jacobina and A.M.N. Lima, An Effective Induction Motor Control for Photovoltaic Pumping, IEEE Transactions on Industrial Electronics, vol. 58, no. 4, pp. 1162-1170, 2011. [4] T. Muthamizhan & R. Ramesh, Design and Simulation of PV driven three phase Induction motor, International Review on Modelling and Simulations, vol. 6, no. 2, pp. 412-418, April. 2013. [5] Y. Yao, P. Bustamante R.S. Ramshaw, Improvement Of Induction Motor Drive Systems Supplied By Photovoltaic Arrays With Frequency Control, IEEE Transactions on Energy Conversion, vol. 9, no. 2, pp. 256-262,1994. [6] R.Y. Chen, T.J. Liang, J.F.Chen, R.L. Lin and K.C. Tseng, Study and implementation of a current-fed full-bridge boost DC DC converter with zero-current switching for high-voltage applications, IEEE Transactions on Industry Applications, vol. 44, no. 4, pp. 1218-1226, 2008. [7] L. Zhou and X. Ruan, A zero-current and zero-voltage-switching PWM boost full-bridge converter, Proceedings of thirty-fourth annual conference in Power Electronics Specialist Conference, 2003, vol. 2, pp. 957-962. [8] B. Singh, S. Jain and S. Dwivedi, Direct Torque Control Induction Motor Drive with Improved Flux Response Advances in Power Electronics, vol. 2012, pp. 1-11, 2012. [9] E.E. El-kholy, R. Kennel, A. El-refaei, S.A. El-Latif and F. Elkady, Robust Space Vector Current Control for Induction Motor Drives, Journal of Electrical Engineering, vol. 57, no. 2, pp. 61 68, 2006. [10] K. Zhou and D. Wang, Relationship Between Space-Vector Modulation and Three-Phase Carrier-Based PWM: A Comprehensive Analysis, IEEE Transactions on Industrial Electronics, vol. 49, no. 1, pp. 186-196, 2002. [11] G.S. Buja and M.P. Kazmierkowski, Direct torque control of PWM inverter-fed AC motors - A survey, IEEE Transactions on Industrial Electronics, vol. 51, no. 4, pp. 744-757, 2004. [12] S. R. Maturu and A. Vujji, SVPWM Based Speed Control of Induction Motor Drive with Using V/F Control Based 3-Level Inverter, VSRD International Journal of Electrical, Electronics & Communication Engineering, vol. 2, no. 7, pp. 421-437, 2012. [13] A. Sivakumar, T. Muthamizhan, N. O. Gunasekhar & R. Ramesh, A Novel Sensorless Speed Control Strategy of Induction Motor Based on Vector Control, International Review of Electrical Engineering, vol. 8, no. 4, pp. 1211-1217, Aug. 2013. [14] A. Choudhury and K. Chatterjee, Speed sensor less direct torque controlled induction motor drive with constant switching frequency operation, Proceedings of the international conference on Energytech,2011, pp. 1-6. [15] K.K. Yoon and S.H. Kim, Sensorless Speed Control of Induction Motor by Direct Torque Control with Numerical Model, Journal of thekorean Society of Marine Engineering, vol. 36, no. 6, pp. 830-836, 2012. Copyright to IJAREEIE www.ijareeie.com 262