AEI800L Avid extreme Liquid Cooled Inverter Module Data Sheet REV 00, March AEI800L Liquid Cooled Inverter Module Data Sheet

Similar documents
SKS B2 120 GDD 69/11 - A11 MA PB

SKS B2 120 GD 69/11 - MA PB

TENTATIVE PP800D120-V01

SKS C 120 GDD 69/11 A3A MA B1C

SKS C 240 GDD 69/11 A6A MA B1C

8V General information. 2 Order data 8V

SKS B2 140 GDD 69/12 U A11 MA PB

IAP200T120 SixPac 200A / 1200V 3-Phase Bridge IGBT Inverter

Features: Phase A Phase B Phase C -DC_A -DC_B -DC_C

TENTATIVE PP225D120. POW-R-PAK TM 225A / 1200V Half Bridge IGBT Assembly. Description:

8V General information. 2 Order data 8V

Absolute maximun ratings. 50 Hz SEMIKUBE - Size T2H. Three phase inverter VBUS Rated DC voltage 750 VDC Efficiency W η Inverter efficiency

PAM & SAM System User s Manual

SKS B2 140 GD 69/12 U - MA PB

CHAPTER 7 HARDWARE IMPLEMENTATION

Datasheet (Preliminary) Modular Inverter System VARIS Datasheet VARIS

BAP1551 Gate Drive Board

Absolute maximun ratings. 50 Hz SEMIKUBE - Size T0.5

Technical. Application. Assembly. Availability. Pricing. Phone

PP400B060-ND. H-Bridge POW-R-PAK IGBT Assembly 400 Amperes/600 Volts

IAP100T120 Integrated Advanced PowerStack 100A / 1200V Three-Phase-Bridge IGBT Inverter

IAP200B120 Integrated Advanced PowerStack 200A / 1200V Full-Bridge IGBT Inverter

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

Power Supply Unit (550W)

FEATURES DESCRIPTION THE OEM ADVANTAGE

Signet 9950 Dual Channel Transmitter

6MS30017E43W Technical Information. Preliminary data. General information ~ ~ ~ ModSTACK HD

ZT-30 ZeroTEM TRANSMITTER MANUAL

Ametek, Inc. Rotron Technical Products Division. 100 East Erie St., Suite 200 Kent, Ohio User's Guide. Number Revision F

SX (400 V) System configuration

TECHNICAL PRODUCT DATASHEET

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

AN003. Basic Terms Used for DC Power Supplies. Elaborated by: Marco Geri (R&D Manager - NEXTYS SA.)

SX (400V) System configuration

Tentative. Rectifier Module VARIS R-400-H. Tentative VARIS -R

Datasheet. Modular Inverter System VARIS Datasheet VARIS

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

PM50. Technical Data TECHNOSOFT. DSP Motion Solutions. Power Module for DC, Brushless DC and AC Motors. Version 3.0. PM50 v3.0.

GE FANUC Spares. GE Fanuc Automation. Stepping Motor Cube with Pulse and Direction Interface. Programmable Control Products.

IS-3000 SERIES INFRARED SCANNER

CNC4PC. C19 A/C FREQUENCY CONVERTER Rev. 4

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

PART MAX1658C/D MAX1659C/D TOP VIEW

T6+ Analog I/O Section. Installation booklet for part numbers: 5/4-80A-115 5/4-90A-115 5/4-80A /4-90A-1224

ACH550 HVAC Drive Submittal

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

External RF Driver. Electrical Driver for AOTF-crystal. Instruction Manual

Military (Airborne, ground-fix, shipboard), Ruggedized, Telecom, Industrial

1525-BRS INFORMATION MANUAL SERV O D YN A M ICS. D y n ad r iv e Ave Crocker Suite 10 Valencia, CA

General Specifications FECA-TE /2010. Phone: Fax: Web:

S1 Programming Chart Program Description S1 Switch Positions. Constant ON High/Low Track, WR

SX (690 V) System configuration

VXR S SERIES 1.0 DESCRIPTION 1.1 FEATURES 1.2 COMPLIANCE 1.3 PACKAGING 1.4 SIMILAR PRODUCTS AND ACCESSORIES

SKAI 90 A2 GD06-W12CI

In the event of a failure, the inverter switches off and a fault code appears on the display.

AF91 Adjustable Frequency Drives Series B

6MS30017E43W TechnicalInformation. Preliminarydata. Generalinformation. ModSTACK HD

New Servo Concept: Junma

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

AV-300i Specifications. Saftronics Inc. PC10 Product Specifications PC10. Mini Vector AC Drive

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

PACSystems* RX3i IC695MDL765

Drives 101 Lesson 3. Parts of a Variable Frequency Drive (VFD)

PA FAN PLATE ASSEMBLY 188D6127G1 SYMBOL PART NO. DESCRIPTION. 4 SBS /10 Spring nut. 5 19A702339P510 Screw, thread forming, flat head.

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

DC Link. Charge Controller/ DC-DC Converter. Gate Driver. Battery Cells. System Controller

MDC V, 2A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

Power Regenerative Converter, THYFREC CV240S

SKS SL 80 GD 50/10 - E4 P1

EFC 3600 Frequency converter for higher energy efficiency and improved process control

RFM HSD MHz 350W Class A/AB High Performance Amplifier with High Speed Disable

Integrated servo motor

MAX8863T/S/R, MAX8864T/S/R. Low-Dropout, 120mA Linear Regulators. General Description. Benefits and Features. Ordering Information.

IRT Mini Evo. Technical Manual. quality IN MOTION. quality IN MOTION

Power Pulse Modulator A High Performance Versatile Square Pulse Generator

P/N: AX Applications: Typical applications can include: test stands; and industrial automation.

ADJUSTABLE SPEED DRIVES FS1

BTM Series Pulsed RF Power Amplifier Modules. Application Note

150mA, Low-Dropout Linear Regulator with Power-OK Output

Analog Servo Drive 25A20DD

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

SKS SL 150 GD 50/10 - E4 P1

Datasheet (Preliminary) Modular Inverter System VARIS XT Datasheet VARIS XT

Analog Servo Drive 30A20AC

FM20VHIR FM20VVIR. RedLink Fiber Optic Receiver for Direct High Voltage Switching Preliminary Data Sheet DESCRIPTION FEATURES APPLICATIONS

UniStream Uni-I/O Modules

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

3-PHASE BRIDGE DRIVER

Low Profile. 3 Year Warranty

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

NetBiter I/O Extender 4RO 6RTD 8DIO - DAIO User Manual Revision 1.00

3 Circuit Theory. 3.2 Balanced Gain Stage (BGS) Input to the amplifier is balanced. The shield is isolated

Ocean Controls KT-5198 Dual Bidirectional DC Motor Speed Controller

IRT AT-Small. Technical Manual. quality IN MOTION. quality IN MOTION

MODEL: 20VS2-02. Hybrid IC Isolation Amplifiers 20 Series

FAN MHz TinyBoost Regulator with 33V Integrated FET Switch

maxon motor maxon motor control 4-Q-EC Servoamplifier DES 70/10 Order number

PACSystems* RX3i IC695ALG600

PEAKTRONICS AMI-103. AC Motor Interface AMI-103 AMI-103A AMI-103B FEATURES

1140LA Broadband Power Amplifier

Transcription:

AEI800L Avid extreme Liquid Cooled Inverter Module REV 00, March 2016 Avid Controls Inc. 41261 Park 290 Drive, Waller, TX 77484, USA info@avidcontrolsinc.com (+1) (281) 640-8600 Page 1 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

Contents 1. Introduction... 3 2. WARNINGS... 3 3. Specification... 4 3.1 Electrical Power Section... 4 3.2 Electrical Control & Interface Section... 5 3.3 Cooling... 6 3.4 Environmental... 6 3.5 Mechanical... 7 4. High Voltage / Power Connections... 8 5. Low Voltage / Control Connections... 8 5.1 Overview... 8 5.2 TB3 24V DC Power... 9 5.3 TB4 Analog Outputs... 9 5.4 TB5 Solid State Relays... 10 5.5 TB6 External Trip... 10 5.6 PL2 Controller Connection... 10 6. User Selectable Options... 11 6.1 Overview... 11 6.2 Over-volts Trip Mode... 11 6.3 Condensation Detection Trip Defeat... 12 6.4 Analog Output Mode... 12 7. LED s and Fault Indication... 13 7.1 Discrete LED s... 13 7.2 LED Feedback Indication... 14 7.3 Fault Codes... 15 8. Document Revision History... 16 Page 2 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

1. Introduction The AEI800L inverter module is a high reliability liquid cooled inverter module with a nominal rating of 800A and 690Vac. Its significant technical attributes are: o Sintered solder-free IGBT modules for extended life operation o Ruggedized IGBT die for improved environmental robustness o Reduced internal voltage overshoot o More robust, fully digital gate driver o Built-in condensation detection o Continuous, accurate monitoring of IGBT silicon temperature under all operating conditions It is intended as an upgraded replacement for the MVDL800 modules from GE Power Conversion, and is therefore broadly compatible with that module. Unless otherwise stated in this data sheet, all documentation related to the GE Power Conversion MV DELTA and the MV3000 drive range is applicable to the AEI800L module. This data sheet should be considered an addendum to that documentation set. For reference, a typical set of applicable GE documents is: o T1676EN, MV3000 Getting Started Manual for AC-fed Drives o T2002EN, MV3000 Getting Started Manual for Active Energy Management Drives o T1693EN, MV DELTA Liquid Cooled Drive System o T1679EN, MV3000 Drive Range Software Technical Manual 2. WARNINGS Always refer to the Cautions and Warnings in the associated MV DELTA and MV3000 manuals when installing / commissioning / fault-finding any system containing an AEI800L module. This equipment may be connected to more than one live circuit. Disconnect ALL supplies before working on the equipment. Wait at least 5 minutes after isolating supplies and check that the voltage between DC+ and DC- has reduced to a safe level before working on the equipment. Surfaces on the coolant pipes can reach high temperatures and remain hot for some time after power is removed. Ensure that all coolant has cooled to a safe temperature and the equipment is suitably drained and isolated before the external pipework is disconnected from the equipment. Page 3 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

3. Specification 3.1 Electrical Power Section Specification Continuous Current, 690V Renewable Energy Applications Continuous Current, 600V Pump Applications Value for AEI800L 800A 800A Notes & Applicable Conditions 60s Overload = 110% once per 10 minutes DC Link Voltage = 1100V Coolant Temp. = 60 C PWM Frequency = 1.8kHz (Generator) = 2.5kHz (Network) Generator Power Factor = -0.89 Network Power Factor = 1.00 Generator & Mains Freq. > 20Hz 60s Overload = 110% once per 10 minutes DC Link Voltage = 850V Coolant Temp. = 60 C PWM Frequency = 2.5kHz Motor Power Factor = 0.85 Motor Frequency > 20Hz Continuous Current, 600V Hoist Applications Continuous DC Link Operating Voltage Short Term (7.5s) DC Link Operating Voltage Non-Operating DC Link Withstand Voltage 587A 1188 V 1262 V 1350 V DC Link Capacitance 12800 µf 60s Overload = 150% once per 10 minutes DC Link Voltage = 820V Coolant Temp. = 60 C PWM Frequency = 2.5kHz Motor Power Factor = 0.85 Motor Frequency > 1Hz Maximum PWM Frequency 2.5 khz In some circumstance, higher frequencies may be used with de-rating contact Avid Controls if this is required. Page 4 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

3.2 Electrical Control & Interface Section Specification Value for AEI800L Notes Controller Interface 40-Way Ribbon Connector Fully compatible with GE Power Conversion DELTA Transistor Module Control Power Source External 24 V DC Supply Does not use DELTA SMPS Module Control Power Voltage 24 V DC +/- 5 % Power on and power off transients must occur in less than 500ms and be monotonic. Control Power Current Continuous (Peak) 5A (10A) Analog Outputs Fault Indication Operational Indication 4 Channels +/-10V Fault Codes indicated on CDC for all compatible faults Two digit LED display for additional diagnostic codes Two 24V Solid-State relay outputs for indication of fault status and condensation detection Two digit LED display for display of DC link voltage, currents and temperatures Optional indication for phase currents, temperatures etc. DIP switch function selection See section 7.3 for definition of fault codes. See section 7.2 for details. DC Link Voltage Feedback Accuracy +/- 4V @ 1000V DC Measured internally within inverter unit Page 5 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

3.3 Cooling Specification Value for AEI800L Coolant Type Minimum Coolant Flow Maximum Coolant Inlet Pressure Coolant Pressure Drop 50/50 Water/Ethylene Glycol 25 liters/min (6.6 US-GPM) 300kPa (45psi) To be determined, but not meaningfully different to DELTA module Maximum Coolant Inlet Temperature 60 C Minimum Coolant Inlet Temperature 0 C Coolant Connection Options Typical heat load to coolant (allow 33% more than quoted values when designing cooling system) 2x Quick-Disconnect at bottom of unit 2x hose-barb at bottom of unit 1x hose-barb top, and 1x hose-barb bottom 1100Vdc, 800A, PWM= 2.5kHz, PF= 1.0: 8.8kW 1100Vdc, 800A, PWM= 1.8kHz, PF= -0.89: 7.0kW 850Vdc, 800A, PWM=2.5kHz, PF= 0.92: 7.1kW 976Vdc, 800A, PWM=1.25kHz, PF=0.90: 5.5kW 3.4 Environmental Specification Ambient Temperature (Internal cabinet temperature) Humidity Value for AEI800L 0 to 50 C 5% to 95% RH Unit must not be operated in the presence of condensation. Page 6 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

3.5 Mechanical Specification Dimensions Mass Electrical Connections Mounting Value for AEI800L 248mm W x 1232mm H x 546mm D) (9.75 W x 48.5 H x 21.5 D) 105kg (231lb) Location and type compatible with MVDL800 Module Fully compatible with MVDL800 Module Page 7 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

4. High Voltage / Power Connections AEI800L Liquid Cooled Inverter Module All power connections are compatible with the GE 800A DELTA module: Connection AC Power Terminals DC Power Terminals Ground Connection Auxiliary Power Supply Connection Value for AEI800L 2 x M10 studs per phase Maximum cable size per stud is120mm 2 2 x M10 studs each for DC+ and DC- Maximum cable size per stud is120mm 2 1 x M10 bolt 2-way connector TB1 for optional auxiliary SMPS 5. Low Voltage / Control Connections 5.1 Overview All control connections are made to terminals and plugs on the Controller Interface Board (C.I.B.) as shown in the following image (left hand side is towards the top of the unit when installed): 1 2 3 4 1 2 3 4 5 1 2 3 4 1 2 24V The terminal blocks may not be physically numbered pin one is always towards the top of the unit when installed. Page 8 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

5.2 TB3 24V DC Power Terminals Function Specifications and Notes 1, 2 3, 4 24V SUPPLY [+] 24V SUPPLY [-] 24V DC Supply, +/-5%, 10A maximum load Recommended to use two terminals each for supply and ground to minimize volt drop [-] terminals are connected to system 0V [GROUND] on the C.I.B. 5.3 TB4 Analog Outputs Terminals Function Specifications and Notes 1, 2, 3, 4 ANALOG OUTPUT A, B, C, D 5 0V (GND) Analog outputs for user diagnostic monitoring See section 6.4 for details on selecting specific signals to be output via analog outputs. Range is +/-10V Maximum load current is 5mA Output source impedance is 100Ω Maximum error at all outputs is +/- 1% of full range with zero load Page 9 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

5.4 TB5 Solid State Relays Terminals Function Specifications and Notes 1, 2 SS RELAY A 3, 4 SS RELAY B Inverter module fault indication Relay energized indicates no fault condition Relay de-energized indicates a fault condition Condensation detection indication Relay energized indicates that condensation is NOT detected in the unit Relay de-energized indicates that condensation IS detected in the unit This is provided so that external system control logic may de-energize the whole drive system when condensation is detected. Maximum operating voltage is 60Vdc / 40Vac(rms) Maximum load current is 0.4A Typical ON resistance is 0.5 Ω NOT overload (short-circuit) or overvoltage protected For reference, on-board device is Panasonic AVQ202A solid-state relay. 5.5 TB6 External Trip Terminals Function Specifications and Notes 1 EXT TRIP SUPPLY 2 EXT TRIP IN Connected to +24V SUPPLY via 150Ω resistor Connect to EXT TRIP IN to allow unit to run > +12V is healthy input < +7V causes the unit to trip on EXTERNAL TRIP fault Typically connected to EXT TRIP SUPPLY (as unit shipped) 5.6 PL2 Controller Connection Standard 40-way ribbon cable header Connected to CDC Controller PL2 to PL7 (depending on system configuration) Identical to 40-way ribbon header for controller interface on the GE Delta module Connection to CDC must be segregated, shielded and bonded in the same manner as the GE DELTA Module Page 10 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

6. User Selectable Options AEI800L Liquid Cooled Inverter Module 6.1 Overview There are a number of options for the inverter unit that must be configured. These are configured using a set of 8 DIP switches on the Controller Interface Board. These switches are numbered from 1 to 8, the ON position is towards the PCB itself, and the OFF position is towards the edge of the board. The DIP switches are very small, so a fine point instrument (and decent eyesight) is needed to set them correctly. The unit is shipped with all DIP switches in the OFF position. 6.2 Over-volts Trip Mode On the GE Delta, the DC link over-volts trip mode is configured on the switch-mode power supply (SMPS) unit. For the Avid module, this configuration is done on the inverter module itself, using DIP switches 1-4. The following table defines the operation of these switches: SWITCH SETTINGS SW 1 SW 2 SW 3 SW 4 DC Link Voltage Trip Instant DC Link Voltage Trip Delayed Delay Time Notes OFF OFF OFF OFF 1188 Vdc None N/A OFF OFF OFF ON 0.5s OFF OFF ON OFF 1.0s OFF OFF ON ON 1.5s OFF ON OFF OFF 2.0s OFF ON OFF ON 2.5s OFF ON ON OFF 3.0s OFF ON ON ON 3.5s 1262 Vdc 1188 Vdc ON OFF OFF OFF 4.0s ON OFF OFF ON 4.5s ON OFF ON OFF 5.0s ON OFF ON ON 5.5s ON ON OFF OFF 6.0s ON ON OFF ON 6.5s ON ON ON OFF 7.5s ON ON ON ON 1290 Vdc None N/A Equivalent behavior of GE MVC3003-4020 and MVC3003-4003 SMPS modules Equivalent behavior of GE MVC3003-4030 SMPS Module Units configured in one of these modes are used in the Delta 1 position of the MV3000 system. Equivalent behavior to GE MVC3003-4025 SMPS module. This mode is used in the Delta 2 to 6 position of the MV3000 system Page 11 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

6.3 Condensation Detection Trip Defeat SW5 sets the action taken when the internal condensation detector is active: OFF: Condensation detection is signaled via SS Relay B. Additionally, the unit will trip the drive system when condensation is detected. ON: Condensation detection is signaled via SS Relay B, but unit does not trip. This mode is provided to minimize nuisance tripping but with an increased risk of operation in the presence of damaging condensation. 6.4 Analog Output Mode The unit provides four analog outputs for system monitoring / debugging. See section 5.3 for electrical specifications. Scaling of different signal types is as follows: Signal Type Current DC Link Voltage Temperature Condensation Scaling +/- 10 V output is equivalent to +/- 2500A Positive values are defined as positive current OUT of the AC terminals of the unit. When the output mode is rectified phase currents, only positive values will be output. The formula for rectified mode is: Output = MAXIMUM ( Ia, Ib, Ic ). 0 to +10V is equivalent to 0 to 1500 Vdc 0 to +10V is equivalent to 0 to 150 C Note that due to the nature of the internal temperature sensor, any temperature below 30 C will be indicated as 30 C. 0V indicates no moisture detected. +5V indicates the moisture detection is at the trip level. +10V indicates double the trip level. Page 12 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

The signals that are output are controlled by DIP switches 6 & 7: Switch Positions Mode Analog Channel Outputs SW7 SW6 A B C D OFF OFF MIXED Full wave rectified AC currents Maximum IGBT module temperature Minimum IGBT module temperature OFF ON CURRENTS A phase AC current B phase AC current C phase AC current ON OFF TEMPS. ON ON LOG A phase IGBT module temperature Full wave rectified AC currents B phase IGBT module temperature Maximum IGBT module temperature C phase IGBT module temperature Condensation detector signal DC Link Voltage 7. LED s and Fault Indication The unit has two discrete LED s (red and green) and a two digit LED display. The discrete LED s indicate the operational state of the unit and the numeric display may either indicate various feedback signals or all active faults. 7.1 Discrete LED s - OFF - ON - FLASHING RED LED GREEN LED Meaning 24V supply is not present Internal error present on Controller Interface Board or 24V supply is out of tolerance Unit healthy (not tripped) and disabled (IGBT s not switching) Unit healthy (not tripped) and enabled (IGBT s switching) Unit faulted. Fault codes will be displayed on 2-digit display, appropriate fault codes sent to CDC (as supported see section7.3) CDC is attempting a reset cycle Page 13 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

7.2 LED Feedback Indication When the unit is not faulted, the 2-digit LED display cycles through indications of a number of operational feedbacks. Each feedback is displayed for 1s, before the display cycles to the next feedback. A "--" pattern is used to indicate the start of the cycle. The cycle is: "--" CURRENT - A PHASE CURRENT - B PHASE CURRENT - C PHASE TEMPERATURE A PHASE TEMPERATURE B PHASE TEMPERATURE C PHASE DC LINK VOLTAGE In a similar manner to the analog outputs, each value is displayed as the percentage of a defined value: Signal Type Explanation & Scaling Current DC Link Voltage Temperature 100% output is equivalent to 2500A The formula for the indication is: o % CURRENT = 100% x AVERAGE 1s ( Phase Current ) / 2500A Or, in words, the formula is the absolute current averaged over 1s, expressed as a percentage of 2500A Average over 1s expressed as percentage of 1500 Vdc Expressed as percentage of 150 C (0 C = 0%, 150 C = 100%) Note that due to the nature of the internal temperature sensor, any temperature below 30 C will be indicated as 20%. Page 14 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

7.3 Fault Codes When the unit has a fault, the 2-digit LED display cycles through a list of all active faults. Each fault that the unit recognizes is encoded into a compatible fault code for indication by the CDC. The Avid unit can identify many more and different faults than the CDC is able to recognize, so some rationalization has been necessary. The following table describes each fault code on the unit, together with the fault code that is transmitted to the CDC for each of the faults recognized by the Controller Interface Board: Fault Code on LED Display Meaning Trip Code Transmitted to CDC *1 See MV3000 Software Technical Manual for Details 1 A Phase IGBT Self-Protect Fault 31 2 B Phase IGBT Self-Protect Fault 33 3 C Phase IGBT Self-Protect Fault 35 4 A Phase Heatsink Over Temperature Fault 32 5 B Phase Heatsink Over Temperature Fault 34 6 C Phase Heatsink Over Temperature Fault 36 7 A Phase Silicon Over Temperature Fault 32 8 B Phase Silicon Over Temperature Fault 34 9 C Phase Silicon Over Temperature Fault 36 10 Over Voltage (DC Link) 38 11 External Trip Fault 37 12 Internal Fan 1 Failure (on units where this fan is fitted) 243 13 Internal Fan 2 Failure (on units where this fan is fitted) 243 14 Internal Fan 3 Failure (on units where this fan is fitted) 243 15 Internal Fan 4 Failure (on units where this fan is fitted) 243 16 Internal Fault *2 240 17 Internal Fault *2 241 18 Internal Fault *2 242 19 Internal Fault *2 240 20 Internal Fault *2 240 21 Internal Fault *2 247 Page 15 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00

Fault Code on LED Display Meaning Trip Code Transmitted to CDC *1 See MV3000 Software Technical Manual for Details 22 Internal Fault *2 248 23 Internal Fault *2 249 24 Internal Fault *2 244 25 Internal Fault *2 245 26 Internal Fault *2 246 27 A Phase Positive Instantaneous Overcurrent 31 28 A Phase Negative Instantaneous Overcurrent 31 29 B Phase Positive Instantaneous Overcurrent 33 30 B Phase Negative Instantaneous Overcurrent 33 31 C Phase Positive Instantaneous Overcurrent 35 32 C Phase Negative Instantaneous Overcurrent 35 33 Condensation Detected 212 34 Internal Fault *2 212 *1: The fault code for a unit connected in the Delta 1 position of the MV3000 system is given. For units in other positions the equivalent fault code will be displayed by the CDC. See the MV3000 documentation for details. *2: These faults indicate a fault within the MV3000 system. They do not occur in normal operation and user fault-finding is generally not possible. In the unlikely event that these faults are experienced, contact Avid Controls for support. 8. Document Revision History Rev. Date Author Changes 00 3/14/2016 Gary Pace Document created Page 16 of 16 Copyright 2016 Avid Controls Inc. DTS-MID0012-REV_00