PV SLATE ROOF INSTALLATION GUIDE

Similar documents
INSTALL IN 2 DAYS. *Assumes 3-man fitting team. equinox. Tiled roof system. Installation guide ISSUE 1

Gambrel Barn with Overhang Manual

1. Tile Roof Installation:!

Blokes Shed INSTALLATION INSTRUCTIONS Custom Design & Build. Nationwide Delivery

Installation Instructions of HomeTech Fakro Skylights

Gambrel Barn Construction Manual 8x8 through 16x24 Units

Roll-Fix Kit The complete dry hip kit RFIG

How To Build Decorative. Timber Awnings

NEW equinox INSTALLATION GUIDE Issue

Deluxe Cabana INSTALLATION INSTRUCTIONS. INSTALLATION Deluxe INSTRUCTIONS Cabana

-1- Coach Instructions.

NEW equinox INSTALLATION GUIDE Issue

Siding Systems NOVIKSTONETM FS FIELDSTONE INSTALLATION GUIDE

MOUNTING INSTRUCTIONS CONCRETE PURLIN BRACKET

Classic Saltbox Manual

PROFESSIONAL PITCHED ROOFING ANCILLARIES

Star Barn Manual. Tools Needed:

NEVADA ASSEMBLY INSTRUCTIONS

AQUAGARD EPDM FLAT ROOFING SYSTEMS INSTALLATION GUIDE THE MECHANICALLY FIXED SYSTEM

HeavenScape Premium Skylightys Installation Instructions

ROOF FRAMING INFORMATION BATTEN INSTALLATION CORONA SHAKE INSTALLATION ACCESSORY INSTALLATION ESTIMATING DATA GENERAL INFORMATION

Base : (1 - batten spacing, 2 - bottom row batten spacing, 3 - ECOTILE, 4 - batten, 5 - rafter, 6 - fixing method)

Shingle Installation Guide

IDAHO ASSEMBLY INSTRUCTIONS. BASE SIZE: 1.800m x 1.200m

Installation. ng Kitt

GSE INTEGRATION INSTALLATION MANUAL For photo-voltaic systems partially covering the roof

B A T H R O O M G L A S S

150 MM FREE STANDING WOOD FIRE FLUE KIT INSTALLATION INSTRUCTIONS

On-Roof Mounting Sets for Flat-Plate Collectors

Playaway Swiss Cottage Assembly Instructions

S H E D A S S E M B L Y I N S T R U C T I O N S

4 Position the Suntile to the x tile s position and mark the felt around the square box flange. Then remove the Suntile

Installation guide for 20/20

lindab cover line installation instructions lindab roca Lindab CoverlineTM Lindab Roca Installation instructions

orientation Conergy SunTop Instructions for professional installation

Potting Store Assembly Instructions

The Leka System Installation Guide

Sandtoft installation guides

IRONWOOD SHAKE & FLASHING SPECIFICATIONS

Installation Guidelines

INSTALLATION INSTRUCTIONS for PYROCLASSIC FIRES LTD. 100mm SLOPING CEILING FLUE KIT

Siding Systems NOVIKSTONETM DS DRY STACK STONE INSTALLATION GUIDE

Quick Hook SS & LS Standard and Low Height Hooks for Side Mount Rails

KNOB LATCH. Specifications: Glass-To-Wall Installation CAT NO. LAT001 C.R. LAURENCE CO., INC. PROFESSIONAL QUALITY

I. Architectural drawings. Pod 4x3 LTH (34)

GRANDIO G R E E N H O U S E S GRANDIO ASCENT ADDITIONAL ROOF VENT KIT FOR NEW AND EXISTING GREENHOUSE CUSTOMERS

S H E D A S S E M B L Y I N S T R U C T I O N S

NewTech - CleverDeck Composite Decking Installation Guidelines

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

INSTALLATION GUIDE SLIMLINE ROOF LANTERN 4 PANE CONFIGURATION

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Installing Quick Mount PV Products on. Metal Shingle Roofs RESPECT THE ROOF

INSTALLATION, STORAGE AND WALL CONSTRUCTION DETAILS

10x12 Cape Cod Manual

Hard wearing and durable Quick and easy to install Fully adjustable for batten gauges of mm

Assembly Instructions

TRADITIONAL GABLE ATTACHED PATIO AND CARPORT. Your complete guide to building an ATTACHED Outback TRADITIONAL GABLE PATIO or CARPORT

SolarFlashTM. Instructions. Slate Refit Kit Slate New Build Kit Flat Tile Kit

GV Standard PitchVent

INSTALLATION GIUDE.

2.4 x 1.8 (8 x 6 ) Premier Shiplap Modular Shed Assembly Instructions

Quick Hook SB & LB Standard and Low Height Hooks for Bottom Mount Rails

CURVED ROOF ASSEMBLY INSTRUCTIONS ATTACHED VERANDAH. Your supplementary guide to building an ATTACHED CURVED ROOF VERANDAH or PATIO BEFORE YOU START

Contents. Stage 1. Preparation of the aperture 9. Interior finishing 25

Garage. Door. Unframed Tracked Fitting Instructions V2.2. fitting instructions. Warning!

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

This installation guide has been created to assist in constructing a Liniar conservatory roof from a kit format.

Before installation, check your local and state requirements for this type of install.

YWY M08 The new VELUX solution

INSTALLATION INSTRUCTIONS. Deluxe Continuous Hinge Inline Door & Panel Shower Enclosure QCI5230

General Installation Guidelines

6 Foot/ 1800mm Aisle Width Net-Contain Aisle Containment for N-Type and S-Type Cabinets

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

Vi - BOX GUTTER COMPONENT REFERENCE

Installation Guide 2016

Siding Components. Installation Guide

BLACK WIDOW COMPOSITE

LE7000 Provincial Built-in (Zero Clearance) Kit Instructions.

The WANZ Guide to Window Installation

ENGINEERING STRENGTH INSTAL L AT I O N M A NUAL OUR STRENGTH IS OUR STRENGTH

Precut Workshop & Gable Manual

INSTALLATION MANUAL 32273/1205 C C-403 GB - F - D - NL - ES - I - S - SLO

Corner Potting Store Assembly Instructions

Installation Guide GRP Dormer

Assembly Instructions

CLEARSPAN GABLE STRATCO OUTBACK ASSEMBLY INSTRUCTIONS. WITH GAZEBO END ATTACHED PATIO

GV Standard Sliding Over Roof Installation Instruction Manual

Installation Instructions

MISCELLANEOUS CABINET REPAIRS

Stratco Sanctuary INSTALLATION BEFORE YOU START TOOLS REQUIRED GUIDE

CONTENTS. Transitions Board and Batten Vertical Installation... 10,11

SLATE & SHINGLE INSTALLATION

INSTRUCTIONS FOR ASSEMBLY 2355mm x 3125mm Workshop

SunTrackerTwo Preparation

Fibre Cement G C. Batten Fixing Setout ST-01. Jan 2014 A4 PROFILE DATE SCALE DETAIL DETAIL NO. Plank joint. 600mm stud crs.

Installation guide. Step-by-step instructions

manthorpe Roll-Out Dry Fix Ridge System building products Fixing Instructions MBP 8265e

15 YEAR GUARANTEE. Tough and long lasting Guaranteed waterproof for 15 years Economical and easy to fix AVAILABLE IN A RANGE OF COLOURS

Aluminum Clad Wood Window 1/2 Reinforced Field Mulling and Stacking Supplement

woodworkersjournal.com MATERIAL LIST

Transcription:

The PV Slate roof tile is designed to integrate into a roof clad with either natural or imitation slates. Initial Roof Batten Layout. The roof should be battened using 50x25mm batten at a spacing of 270mm. Where natural slates are to be fitted the battens should be doubled up with the extra batten being fitted on the lower side. In areas where the tiles are not to be fitted the batten spacing should be 243mm. The lower course natural slates are nailed into place. Inline with standard roofing practice inclusive of lower waterproof slate row underneath

The next natural slate course, (the row below the PV Slate) are cut to 450mm and fixed in place using nails and 130mm slate hooks. Trimming the slate to this length allows clearance for the terminal box in the first row of tiles. Between each slate a 130mm slate hook should be inserted. The hook should be nailed in place 10mm below the top of the batten. This hook will support the lower edge of the first row of tiles.

PV Slate assembly. Each PV Slate is supplied with two hooks. These hooks should be inserted into the grommets leaving the hook side uppermost. PV Slate hooks (Supplied) Hook location hole with grommet (Supplied). Hook inserted into hole

Hooks in position.

Installing the PV Slate PV SLATE ROOF The first tile is laid in position and then located into the slate hooks. Do not screw in position just yet. The left hand flashings are supplied as separate items. Both sides have silicon sealing tape applied. The tape is protected by the coloured plastic strip.

The left side flashing is designed to fit under the side of the PV Slate on the left hand side. At the end of each PV Slate row or the start of each PV Slate row (dependant on working left to right or right to left) to interface with the side course of natural slate. The picture illustrates the location. The coloured protective film is removed and discarded. Slide the flashing under the tile and apply gentle pressure to the tile to adhere the silicon seal to the back-side of the PV Slate.

The picture to the left illustrates the flashing in position. The PV Slate can now be screwed in position with the top of the metal support plate flush with the top of the batten. The remainder of the PV Slates may now be fitted. The right-hand flashing is a component part of the tile module. This flashing is also fitted with silicon sealing tape. Remove the coloured protective plastic cover and then install the next PV Slate, gently applying pressure to grab the seal before screwing into place. Leave a gap of approximately 3mm between the tiles to maintain the Standard practice slate spacing for expansion Continue this process until all the tiles in the course are installed.

The edging slates can now be installed to complete the row. Remove the coloured protective film from the silicon seal prior to fitting the slate. Leave a gap of approximately 3mm between the edge of the tile and the natural slate. The fixing nail of the slate may penetrate the flashing.

The top of the natural slate will rest on the double batten above. the same procedure outlined above. The next course can now be fitted following Continue up the roof until the remaining courses have been installed.

When the top course is in place the remainder of the roof can be slated. The top flashing continues the waterproof integrity layer for the next course of natural slates. The flashing rests on the top tile support plate and is screwed into the batten. Once the flashing has been fitted the remainder of the slates can be added to the roof and ridge

2011 GB Sol Ltd. All rights reserved.