1 4 6 7 8 9 10 11 1 1 14 1 16 17 18 19 0 1 Remote Monitoring Outstation s I** & Wire Numbering Schedule Description Controller input terminals. Ie I+ is connector input and I- is connector common. O** Controller Output terminals. R+ R- T- T+ External network connections for future outstations. C** External Milltronics Connections 1 4 6789 9-Way D Male 4 1 9 8 7 6 9-Way D Female 14678 RJ4 146 RJ11 Cable Types Cable 40V Power Description 1mm Red & Black 1 Molex Way.mm Pitch KK Socket 14678910 Molex 10 Way.mm Pitch KK Socket 4Vdc Power 1mm White(+) & Grey(-) Screened Cable 0.mm Core Screened Cable with Drain Wire Connector Pin References VFC Outputs 1mm Red Fuse Schedule Fuse Rating Drawing Grid Ref Description F1 L1 Amp 70 40V Socket Outlet F L Amp 74 40V / 4V Transformer F L Amp 91 GSM Communication Equipment CONTRACTOR S RESPONSIBLE ENGINEER APPROVED TRI CONTROLS APPROVAL APPROVED CHECKED Drawing Definitions 1 OF 7
4 6 7 8 9 0 1 4 6 7 8 9 40 41 4 4 44 40V AC 10A Remote Monitoring Panel 4Vdc Power Supply GSM Node Add64 Milltronics Controller Outstation Gill Type Outside Air Sensor TMN-E GSM XPS-1 Transducer Hard Wired Input/Output Rail Central Servers Schematic Layout OF 7
4 46 47 48 49 0 1 4 6 7 8 9 60 61 6 6 64 6 66 CONNECTOR REFERENCE 1 IQ1 OUTSTATION POINT LIST TYPE LINK NAME Voltage Outstation Battery Thermistor Outside Air Sensor Thermistor Panel Temperature 4 Current Water Level (4-0mA) Digital Sensor Loss of Echo 6 9 Voltage Output 10 Voltage Output 16 17 18 19 GSM Reset 0 Outstation Battery Test Outstation Point Lists OF 7
67 68 69 70 71 7 7 74 7 76 77 78 79 80 81 8 8 84 8 86 87 88 40 F1 A Fused Socket Outlet Rated at Amp Maximum F A Fused Charger Board C9 1 SW1 = Position 1 (Float Mode) 4 Voltage Stabilizing Unit 16 16 IQ 1 Outstation Address 0 16 16 L N E For Computer Only 161 1 0 1 C C NO NC 1 4 6 40v/6v Transformer Management Board C96 R4 10 1 100W Load Test Resistor 1 1 1 6 16 1 14 1 14 R4 NO NC 6 7 7 4Vdc Pole Grid Refs 16 17 6 7 8 L1 Solid Link L Solid Link R4 9 Battery Test +ve -ve +ve -ve Battery No.1 Battery No. Power Supply 10 Amp Pole Type C RCBO 0mA (BHD 99/6) Internal External 4 OF 7
89 90 91 9 9 94 9 96 97 98 99 100 101 10 10 104 10 106 107 108 109 110 6 A Fused F Solid L 170 171 IQ1 19 C NO NC 1 Way Block RS 97 96 GSM Power Cable Pin Wiring M0T 1 4 6 +4Vdc -4Vdc +4Vdc 6 O19NC Power Cable RJ11 6 pin to flying lead IQ 1 Outstation A Address 0 T- T+ R- R+ E E 10 Pin Molex Connector Port B (Modem) J16 GSM RS Cable Pin Wiring TMN-E GSM 1 9 8 6 4 4 & 6 7 7 10 8 1 9 9 Way Male RS Power 6 Pin RJ11 Flying Lead Antenna Seimens M0T GSM Module Male RF Cable FME plug to FME jack RG8 4 metres length TMN-E GSM Node Address 64 T- T+ R- R+ E GSM serial cable 9 Way Male to 10 Way.mm Pitch Molex KK Socket 0mm long SCN terminals not to be connected to panel earth Internal External Low Profile Black Cellular Antenna LS900 External LAN s GSM & Network OF 7
111 11 11 114 11 116 117 118 119 10 11 1 1 14 1 16 17 18 19 10 11 1 6 6 IQ1 IQ1 4 Bead Thermistor Connected Directly To Outstation COLIN Type??? RS part no. E ma Out Transducer RL Milltronics Hydroranger Plus Panel Mount RG-6 A/U Coaxail Cable Internal External RG-6 A/U Coaxail Extension Cable Gill Type Outside Air Sensor Local Junction Box XPS-1 Transducer supplied with 10m of cable I/O & Milltronics Equipment 6 OF 7
1 14 1 16 17 18 19 140 141 14 14 144 14 146 147 148 149 10 11 1 1 14 Gap for door mounted Hydro-Ranger 600 mm 0 mm 1 RCBO Note: DIN rail to be raised 10mm to allow internal screened cable earths to pass underneath for connection to earth bar. G S M 1 TM 800 mm 70 mm Danger 0 Volts TMN-E Charger Board 4V Management Board 4V Outstation - Trunking - DIN Rail TF Battery 1 Battery TRI FRONT OF DOOR BACK OF DOOR INTERNAL BACKPLATE LAYOUT 60mm Outgoing Trunking 1 = Milltronics Hydro-ranger Fixing screws for TMN-E to be mounted behind Danger 40V label TF = Transformer TM = Outgoing s NOTES: 1 - s - Side Entry - Gland Plates Located at Bottom - Door Hinged on Left 4 - Panel Depth 00mm - Not to scale Panel Layout 7 OF 7