BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

Similar documents
BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

capabilities today. Flexibility for tomorrow.

Průtokový cytometr CytoFLEX

BD OneFlow Setup Beads

PAVING THE ROAD TO UTOPIA VIA INSTRUMENT STANDARDIZATION

SP6800 Spectral Analyzer

BD FC Beads 7-Color Kit

Trademarks Cytek, the Cytek logo, and all other trademarks are property of Cytek Biosciences Cytek

CytoFLEX Flow Cytometer Platform. Join the Resolution REVOLUTION

quantiflash Calibration Light Source for Cytometry

BD FC Beads 7-Color Kit

Technical Bulletin. Guide for Using BD Cytometric Bead Array (CBA) Flex Sets with the BD Accuri C6 Flow Cytometer. Introduction

Setup Procedure for Beckman Coulter CytoFLEX Flow Cytometer

AbC Total Antibody Compensation Bead Kit

Synergy NEO HTS Multi-Mode Microplate Reader

Flow cytometer instrument set up

Multi-channel imaging cytometry with a single detector

Quick Guide. NucleoCounter NC-3000

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Light Microscopy. Upon completion of this lecture, the student should be able to:

SpectraMax i3x Multi-Mode Detection Platform. Explore a wealth of applications in one future-ready system

ab Firefly Cytometer Setup Particles

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Comparison of the Analysis Capabilities of Beckman Coulter MoFlo XDP and Becton Dickinson FACSAria I and II

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Mul -Analyte Flow Assay Kit

COMPENSATION: AN INTRODUCTION

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay.

LEGENDplex. Please read the entire manual before running the assay. BioLegend.com. Please read the entire manual before running the assay.

Compact Dual Field-of-View Telescope for Small Satellite Payloads

Improving the Collection Efficiency of Raman Scattering

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

Perform instrument startup and verification check following the manufacturer s recommendations.

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Spark Spectral Sensor Offers Advantages

LEGENDplex. Cat. No Human Proinflammatory Chemokine Panel (13-plex) Please read the entire manual before running the assay.

Perform instrument startup and verification check following the manufacturer s recommendations.

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit

Cytell Cell Imaging System

LEGENDplex Mul -Analyte Flow Flow Assay Kit Kit

The Zeiss AiryScan System, Confocal Four.

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

Image Capture TOTALLAB

LEGENDplex. Cat. No Human Cytokine Panel 2 (13-plex) Please read the entire manual before running the assay.

Enabling Legendary Discovery. LEGENDplex. LEGENDplex. Mul -Analyte Flow Assay Kit. Please read the entire manual before running the assay.

Beyond beads. Develop high performance assays, fast

Microscopy from Carl Zeiss

ImageXpress Micro XLS Widefield High Content Screening System. Imaging with a vision.

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

ScanArray Overview. Principle of Operation. Instrument Components

LSM 510 META in Chang Gung University

FluorChem M MultiFluor System

TouchBright Ver. 7.51

SHORT INSTRUCTIONS FOR OPERATING LSM1/2 (Zeiss LSM510) AT CIAN Version 1.4, September 2014

LEGENDplex. Cat. No Human CD8/NK Panel (13-plex ) Please read the entire manual before running the assay.

ChemiDoc-It Imaging System

Developing a novel method for the screening of fungal germinated spores using hydrogel microencapsulation and large particle flow cytometry.

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

880 Quantum Electronics Optional Lab Construct A Pulsed Dye Laser

Imagers- Molecular, Cell Standard Operating Procedures

Agilent Cary 610/620 FTIR microscopes and imaging systems RESOLUTION FOR EVERY APPLICATION

Experimental Analysis of Luminescence in Printed Materials

Practical work no. 3: Confocal Live Cell Microscopy

Automated Imaging Technology to Simplify Your Workflow!

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

Leica TCS SP8 Quick Start Guide

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

Working Simultaneously. The Next Level of TIRF Microscopy. cell^tirf Illuminator Motorized Total Internal Reflection Fluorescence

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Bi Imaging. Multicolor Imaging: The Important Question of Co-Localization. Anna Smallcombe Bio-Rad Laboratories, Hemel Hempstead, UK

Redefining Gel and Blot Imaging

SP-8001 UV/Visible Spectrophotometer

a) How big will that physical image of the cells be your camera sensor?

Nikon AZ100. Laser Scanning Macro Confocal Microscope. Jordan Briscoe Adam Fries Kyle Marchuk Kaitlin Corbin. May 2017.

Oriel Cornerstone 130 1/8 m Monochromator

TCSPC at Wavelengths from 900 nm to 1700 nm

Ordering Information & Specifications. VisionWorksLS Capabilities. Image Analysis Capabilities

Leica_Dye_Finder :53 Uhr Seite 6 Dye Finder LAS AF

Perkin Elmer Envision 2100 Multilabel Reader

Period 3 Solutions: Electromagnetic Waves Radiant Energy II

SER: Biological Stains Visualization with Alternate Light Sources

Zeiss 780 Training Notes

Quick Guide. LSM 5 MP, LSM 510 and LSM 510 META. Laser Scanning Microscopes. We make it visible. M i c r o s c o p y f r o m C a r l Z e i s s

Leica TCS SP8 Quick Start Guide

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

contents TABLE OF The SECOM platform Applications - sections Applications - whole cells Features Integrated workflow Automated overlay

BioSpectrum Imaging System

a Beckman Coulter Life Sciences: White Paper

Cytometry tutorial: The impact of adjusting PMT voltages on spillover and compensation

SOP-P094. BioMek 2000 Compound Protocol Cyan/Hypercyt + Analysis

Crime-lite 82S SPARES & ACCESSORIES. foster + freeman

G BOX. Gel Documentation and Analysis Automated imaging

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

BD Trucount Controls IVD

2D Protein Gel Image Capture and Analysis

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Transcription:

BD LSRFortessa X-2 Special Order Product Designed for limited space and boundless potential

Next generation high performance cell analyzer The BD LSRFortessa X-2 cell analyzer delivers high performance, multicolor analysis with the most compact footprint in its class at just 3 x 29 in. (76.2 X 73.7 cm) and a height of just 3 in. (76.2 cm). The BD LSRFortessa X-2 can be configured with up to 5 lasers, which enables the detection of up to 2 parameters simultaneously. The most common laser choices are blue, red, violet, yellow-green, and UV. Additional laser choices are available and may be configured at the time of purchase or at a later date to meet evolving application requirements. The BD LSRFortessa X-2 is supported by a full range of BD Biosciences reagents, including the latest BD Horizon Brilliant Violet polymer conjugates, which offer superior brightness and are optimized for use on the BD LSRFortessa X-2. The BD LSRFortessa X-2 cell analyzer is the latest in the line of high-performance instrumentation from BD Biosciences. Based on the industry-leading BD LSRFortessa analyzer, the BD LSRFortessa X-2 integrates the newest laser and light technologies, in a greatly reduced footprint. The BD LSRFortessa X-2 retains the flexibility to support the expanding needs of multicolor flow cytometry assays.

Performance without peer, choice without compromise The most compact footprint in its class The BD LSRFortessa X-2 is designed to support your current assay requirements. In addition, as future needs arise, optical capability can be added or upgraded. Flexibility in a small space The BD LSRFortessa X-2 fits most flow cytometry analyzer needs, and can be ordered with up to 5 lasers most commonly, blue, red, violet, yellow-green, and UV which provides flexibility in laser wavelengths. This allows researchers to optimize assay design by selecting the latest fluorescent dyes and antibodies in experimental protocols. The instrument can accommodate the detection of up to 18 colors simultaneously with a defined set of optical filters that meet today s assay requirements. A compact footprint and height (3 x 29 x 3 in. or 76.2 x 73.7 x 76.2 cm) allow the BD LSRFortessa X-2 to fit easily on the benchtop for the cost-effective use of valuable laboratory space. In addition to the reduced size, design enhancements provide easier access to bandpass filters and mirrors, simplifying changes in the instrument configuration. To improve experimental workflow, the optional BD High Throughput Sampler (HTS) provides rapid, fully automated sample acquisition from microtiter plates. In high-throughput mode, the HTS option can speed through a 96-well plate in less than 15 minutes with less than.5% sample carryover from one well to the next. Low carryover is essential to ensure data quality in research applications. 4

bd lsrfortessa x-2 Emission spectra Excitation laser line (nm) Fluorescence channel Fluorochromes provided by BD Biosciences 488 Green FITC Alexa Fluor 488 Yellow PE PI Orange BD Horizon PE-CF594 PE-Texas Red Red 7-AAD PE-Cy 5 PerCP PerCP-Cy 5.5 Infrared PE-Cy 7 532 b or 561 b Yellow PE PI Orange BD Horizon PE-CF594 PE-Texas Red Red PE-Cy5 Infrared PE-Cy7 64 Red APC Alexa Fluor 647 Far Red Alexa Fluor 7 Infrared BD APC-H7 APC-Cy 7 45 Blue BD Horizon BV421 BD Horizon V45 BD Horizon VPD45 Pacific Blue Green BD Horizon V5 AmCyan Orange BD Horizon BV65 355 Blue Hoechst 33342 5

optics aximum signal, minimum crosstalk An innovative and proven platform for multicolor analysis The patented collection optics are arranged in polygonshaped optical pathways. Their novel design efficiently maximizes signal detection and increases sensitivity and resolution. This enables researchers to identify cells with especially dim expression, or quantitate rare cell populations, by optimizing multicolor assays and panel design for best results. Optics system The optics system uses a novel laser design that illuminates cells in the sample, and collection optics that direct light scatter and fluorescence signals through spectral filters to the detectors. Innovative designs for both the excitation optics and collection optics in BD LSRFortessa X-2 systems minimize light loss and optimize collection efficiency for increased sensitivity and resolution. Excitation optics The excitation optics include a laser array which consists of multiple (up to five) fixed wavelength lasers, beam-shaping optics, and individual pinholes which together produce spatially separated beam spots. A final lens focuses the laser light into the gel-coupled cuvette flow cell. Since the optical pathway and the sample core stream are in a fixed position, alignment is constant from day to day and from experiment to experiment. All Events Optimal resolution of cell populations The high sensitivity of the BD LSRFortessa X-2 allows for optimal resolution of lower expression antigens and rare cell subsets. In this example, regulatory T cells (Tregs), characterized by low levels of expression of CD127 and high levels of CD25, were easily identified. Note the resolution of different levels of expression of CD25 and CD127. SSC-A (x 1,) 5 1 15 2 25 lymphocytes 5 1 15 FSC-A 2 25 (x 1,) 6

Collection optics Emitted light from the gel-coupled cuvette is delivered by fiber optics to the detector arrays. The polygonal optical pathways maximize signal detection from each laser illuminated beam spot. Bandpass filters in front of each PT collect selected fluorophore spectral wavelengths. This arrangement allows filter and mirror changes within the optical array to be made easily and requires no additional alignment. This design efficiently exploits the principle that light reflection is more efficient than light transmission for fluorescence signal detection. Emitted light travels to each PT detector via reflection and is transmitted through only two pieces of glass to reach the detector. Therefore, more colors and higher panel multiplexing can be achieved with minimum light loss. lymphocytes + CD4+ SSC-A (x 1,) 1 15 2 25 CD25 PE-A 1 5 1 4 1 3 CD127 BV421-A 1 5 1 4 1 3 T regs 1 2 5 1 1 1 2-221 -1 2 1 2 1 3 1 4 CD3 PerCP-Cy5-5-A 1 5-76 -388-1 2 1 2 1 3 CD4 APC-A 1 4 1 5-76 1 2 1 3 CD25 PE-A 1 4 1 5 7

fluidics Superior performance Unique and revolutionary designs for multicolor analysis While improved laser and optical detection design features have been incorporated into the BD LSRFortessa X-2, the fluidics system retains the true fixed-alignment flow cell design. The flow cell is gel-coupled to the collection optics to maximize detector signal. Fluidics system The fluidics system is pressure driven. Hydrodynamic focusing forces sample cells through the cuvette flow cell, where they are interrogated. The flow cell is in fixed alignment with the laser and gel-coupled to the collection optics. This design ensures that the laser is precisely focused on the sample stream and the maximum amount of emitted light can be collected for added sensitivity in multicolor applications. Fixed alignment also minimizes startup time, improves experiment-to-experiment reproducibility, and enables automated daily quality control (QC). The sheath container (8 L) and waste container (1 L) are outside the cytometer, positioned on the floor for easy access. Fluidics sensors maintain constant pressure, while a fluidics monitoring system warns when sheath fluid is low or empty, or when the waste container is full. A Characterization of instrument sensitivity using 8-peak beads The sensitivity across detectors of a BD LSRFortessa X-2 equipped with blue (5-mW), red (1-mW), and violet (5-mW) lasers is illustrated by the optimal resolution of SPHERO Rainbow 8-peak beads. Note that all peaks are easily identified in various detectors from the blue (A,B), red (C,D), or violet (E,F) lasers. 5 1 15 B -126 1 2 1 3 1 4 1 5 FITC-A 5 1 15-1 2-226 1 2 1 3 1 4 1 5 PE-A 8

X-mount optical plate C 1 E 5 5 1 75 15 25 D -71 1 2 1 3 1 4 1 5 APC-A -113 F 1 2 1 3 1 4 1 5 BD Horizon BV421-A 8 1 2 3 4 5 6 7 125-155 1 2 1 3 1 4 1 5 APC-H7-A 25 5 75 1-9 1 2 1 3 1 4 1 5 BD Horizon BV65-A 9

Greater consistency Automated controls for setup, acquisition, and analysis BD FACSDiva software controls the efficient setup, acquisition, and analysis of flow cytometry data from the BD LSRFortessa X-2 workstation. The software is common across BD FACS instrument platforms, including the BD FACSCanto cell analyzer and BD FACSAria cell sorter systems. This affords researchers greater application flexibility, allowing them to easily move assays from one platform to another. Cytometer setup and tracking The BD Cytometer Setup and Tracking (CS&T) feature of BD FACSDiva software establishes baseline settings and adjusts for instrument variability. The software reduces operator error, and ensures consistency of results by setting the signal time delay across the multiple laser beams and optimizing PT voltages. Application-specific settings can also be specified, allowing for rapid setup and performance of routine experiments in a more consistent manner. QC tracking capabilities in the software measure instrument settings and report on performance. Levey-Jennings plots help users understand instrument performance and identify maintenance issues. Acquisition and analysis BD FACSDiva software enables researchers to preview and record data from multiple samples with an automated acquisition process. Acquisition templates, user-defined experiment layouts, and simple compensation procedures are also managed by the software to further facilitate acquisition. BD LSRFortessa X-2 front panel Plots A B All Events (x 1,) 2 25 Plots C F Analysis of human T-cell subsets Data shows a 1-color panel run on a 3-laser BD LSRFortessa X-2 with a blue/red/ violet configuration. The panel was used for defining various subsets of regulatory T cells (A, B), memory/effector CD4 + T cells (C, D, E, F), and memory/effector CD8 + T cells (G, H, I, J). SSC-A 5 1 15 SSC-A (x 1,) 15 2 25 5 1 15 2 25 FSC-A (x 1,) All Events CD8 PerCP-Cy5-5-A 1 3 1 4 1 5-864 -87 CD8+ CD4+ CD4 APC-H7-A 1 3 1 4 1 5 1 5 Plots G J -58 1 2 1 3 1 4 1 5 CD3 V5-A 1

bd facsdiva For analysis, the software includes powerful features such as hierarchical snap-to gating, a variety of plot formats, and batch analysis. Recorded data can be analyzed by creating plots, gates, population hierarchies, and statistics views on a BD FACSDiva global worksheet. Once the global worksheet is saved, it can be used to analyze multiple sample tubes from an experiment, thereby saving time. Numerous other productivity benefits include user-defined batch analysis and automated features such as gate resizing, pausing between data files, exporting statistics, and printing before proceeding to the next data file. A CD4+ B CD4+ CD127 low CD25 high CD4+ CD127 low CD25 high -34 CD4+ CD45RO PE-Cy7-A CD8+ CD8+ CD8+ CD8+ CD45RA FITC-A 1 2 1 3 1 4 CD45RO PE-Cy7-A 1 3 1 4 1 5 1 5 CD45RO PE-Cy7-A CD127 BV421-A 1 3 1 4 1 5 1 2 1 3 1 4 1 5 CD127 BV421-A 1 15 2 25 3 35 4 45 1 3 1 4 1 5-14 5 CD45RA FITC-A -14 1 1 1 2 1 3 1 4 1 5 1 2 1 3 1 4 1 5-34 CD25 PE-A 1 3 1 4 1 5 1 3 1 4 1 5-34 CD45RO PE-Cy7-A C D E F 1 1 CD4+ CD45RO PE-Cy7-A 1 3 1 4 1 5 CD27 Alexa Fluor 7-34 CD4+ 1 3 1 3 1 4 1 5 CD28 PE-CF594-A 1 2 1 3 1 4 1 5 1 2 1 3 1 4 1 5-58 CCR7 APC-A -14 CD127 BV421-A G H I J -221-185 1 2 1 3 1 4 1 5 CD4+ 1 2 1 3 1 4 1 5-221 CD27 Alexa Fluor 7-A -974 CD45RO PE-Cy7-A 1 3 1 4 1 5-87 -472 1 3 1 4 1 5 CCR7 APC-A -87 1 2-185 CD28 PE-CF594-A 1 3 1 4 1 5-14 1 2-185 CD28 PE-CF594-A 1 3 1 4 1 5 11

custom Choice now and in the future Special order products for unique needs The innovative special order program is tailored to meet the special needs of research at the leading edge of biomedical discovery, and offers a wide range of choices to help researchers create the ultimate customized instrument for their requirements. ultiple power options Innovative laser options include the choice of solid-state lasers across the full spectrum. Currently, a menu of 18 laser wavelength options is offered, ranging from the complete spectrum of ultraviolet to infrared wavelengths. Through the special order program, researchers can configure a BD LSRFortessa X-2 with up to 5 lasers and 2 positional choices for the detectors. In addition to laser wavelength, the special order program offers multiple laser power options and filter selections to better optimize assay needs. A B C CD3- CD3- CD3-1 5 1 5 1 5 Analysis of human lymphocyte subsets Data shows a 1-color panel run on a 3-laser BD LSRFortessa X-2 with a blue/red/violet configuration. The panel was used for defining various lymphocyte T-cell subsets (A E, this page) and non T-cell subsets (F J, opposite page) using lysed whole blood (BD FACS lysing solution) from a normal donor. CD19 PE-CF594-A 1 3 1 4-87 -1 2 1 3 1 4 1 5-472 CD2 APC-H7-A D CD8 Alexa Fluor 7-A -1 2 1 2 1 3 1 4 1 5 CD3- CD3- CD19 PE-CF594-A 1 3 1 4-87 -1 2 1 3 1 4 1 5-472 CD16 PE-Cy7-A E CD7 PE-A 1 2 1 3 1 4 1 5 CD56 APC-A 1 3 1 4-139 -1 2 1 3 1 4 1 5-472 CD16 PE-Cy7-A Plots A E -34-139 1 2 1 3 1 4 1 5 CD56 APC-A -155-1 2 1 2 1 3 1 4 1 5-34 CD8 Alexa Fluor 7-A 12

configuration Cuvette flow cell Evolving capabilities The BD special order program allows customers to add lasers after their initial system purchase, to meet new or evolving requirements. This wide range of choice and flexibility makes the special order BD LSRFortessa X-2 a solid, long term investment. An innovation process The vigorous sourcing of the latest and best laser technologies ensures an unparalleled range of configuration choices offered by the BD special order program for BD LSR analyzers. New technologies are regularly incorporated into the product line as soon as they become available. The ever-expanding list of available lasers demonstrates BD s ongoing commitment to perpetual innovation. This is one of the many ways BD ensures that the BD LSR analyzer platform continues to support the evolving needs of leading researchers around the world. SSC-A (x 1,) 5 1 15 2 25 All Events CD45+ F CD8 Alexa Fluor 7-A -1 2 1 2 1 3 1 4 1 5 G CD8 Alexa Fluor 7-A -1 2 1 2 1 3 1 4 1 5 H CD7 PE-A 1 2 1 3 1 4 1 5-19 1 2 1 3 1 4 1 5 CD45 V5-A -34-78 1 2 1 3 1 4 1 5 CD4 V45-A -34-1 2 1 3 1 4 1 5-472 CD56 APC-A -155-124 1 2 1 3 1 4 1 5 CD57 FITC-A SSC-A (x 1,) 5 1 15 2 25 CD3- CD45+ Plots F J I CD8 Alexa Fluor 7-A -1 2 1 2 1 3 1 4 1 5 J CD7 PE-A 1 2 1 3 1 4 1 5-723 1 2 1 3 1 4 1 5 CD3 PerCP-Cy5-5-A -34-124 1 2 1 3 1 4 1 5 CD57 FITC-A -155-1 2 1 2 1 3 1 4 1 5-34 CD8 Alexa Fluor 7-A 13

SERVICES Services BD Biosciences is fully committed to the success and satisfaction of its customers. Supporting flow cytometry applications for over 35 years, BD has training, technical application support, and field service teams dedicated to helping customers achieve optimal instrument performance, ease of use, and streamlined workflow. With unmatched flow cytometry experience, this world-class service organization is available to help with your BD LSRFortessa X-2 product installation, future upgrades, and application support. Training Hands-on training is included with each special order BD LSRFortessa X-2 analyzer. Courses are held at BD training centers worldwide. BD flow cytometry training courses combine theory and practice to provide participants with the skills and experience they need to take full advantage of the capabilities of their BD LSRFortessa X-2 analyzer. Technical application support BD technical application support specialists are available to provide field- or phone-based assistance and advice. Expert in all aspects of flow cytometry, BD technical application specialists are well equipped to address customer needs in both instrument and application support. Field service When instrument installation or service is required, a BD Technical Field Service Engineer can be dispatched to the customer site. BD field service engineers are located across the world. On-site service and maintenance agreements are available to provide long-term support for BD LSRFortessa X-2 analyzers. Special order program Instruments can be customized to meet customer requirements via the special order program. 14