Simultaneous Infrared-Visible Imager/Spectrograph a Multi-Purpose Instrument for the Magdalena Ridge Observatory 2.4-m Telescope

Similar documents
Copyright 2006 Society of Photo-Optical Instrumentation Engineers. This paper was published in the Proceedings of SPIE Volume 6267 and is made

Gemini 8m Telescopes Instrument Science Requirements. R. McGonegal Controls Group. January 27, 1996

Observational Astronomy

Presented by Jerry Hubbell Lake of the Woods Observatory (MPC I24) President, Rappahannock Astronomy Club

The Field Camera Unit for WSO/UV

A new Infra-Red Camera for COAST. Richard Neill - PhD student Supervisor: Dr John Young

Big League Cryogenics and Vacuum The LHC at CERN

UltraGraph Optics Design

a simple optical imager

Pocket Pumped Image Analysis Ivan Kotov Brookhaven National Laboratory

GMT Instruments and AO. GMT Science Meeting - March

MS260i 1/4 M IMAGING SPECTROGRAPHS

Exoplanet transit, eclipse, and phase curve observations with JWST NIRCam. Tom Greene & John Stansberry JWST NIRCam transit meeting March 12, 2014

Optical Design. Instrument concept Foreoptics and slit viewer Spectrograph Alignment plan 3/29/13

Oriel MS260i TM 1/4 m Imaging Spectrograph

INTRODUCTION TO CCD IMAGING

DESIGN NOTE: DIFFRACTION EFFECTS

Wide Field Camera 3: Design, Status, and Calibration Plans

Spectral and Polarization Configuration Guide for MS Series 3-CCD Cameras

Southern African Large Telescope. Prime Focus Imaging Spectrograph. Instrument Acceptance Testing Plan

SONG Stellar Observations Network Group. The prototype

An integral eld spectrograph for the 4-m European Solar Telescope

"Internet Telescope" Performance Requirements

Paper Synopsis. Xiaoyin Zhu Nov 5, 2012 OPTI 521

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Puntino. Shack-Hartmann wavefront sensor for optimizing telescopes. The software people for optics

FLAMINGOS at the KPNO 2.1-m

GPI INSTRUMENT PAGES

Binocular and Scope Performance 57. Diffraction Effects

Compact Dual Field-of-View Telescope for Small Satellite Payloads

UV/Optical/IR Astronomy Part 2: Spectroscopy

Optical design of ARIES: the new near infrared science instrument for the adaptive f/is Multiple Mirror Telescope

SpectraPro 2150 Monochromators and Spectrographs

Robo-AO: Robotic Laser Guide Star Adaptive Optics on the Palomar 60 in Christoph Baranec (PI) & Nick Law (PS)

The optical design of X-Shooter for the VLT

DESIGNING AND IMPLEMENTING AN ADAPTIVE OPTICS SYSTEM FOR THE UH HOKU KE`A OBSERVATORY ABSTRACT

Science Detectors for E-ELT Instruments. Mark Casali

The DECam System: Technical Characteristics

Supplementary Materials

arxiv: v1 [astro-ph.im] 26 Mar 2012

Optical Design & Analysis Paul Martini

[90.03] Status of the HST Wide Field Camera 3

Conceptual design for the High Resolution Optical Spectrograph on the Thirty-Meter Telescope: a new concept for a ground-based highresolution

1/8 m GRATING MONOCHROMATOR

Be aware that there is no universal notation for the various quantities.

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Tunable wideband infrared detector array for global space awareness

ARRAY CONTROLLER REQUIREMENTS

CHARA AO Calibration Process

KOSMOS. Optical Design

Astro 500 A500/L-8! 1!

Astronomical Cameras

OPAL Optical Profiling of the Atmospheric Limb

QE65000 Spectrometer. Scientific-Grade Spectroscopy in a Small Footprint. now with. Spectrometers

Optical Design of the SuMIRe PFS Spectrograph

The Imaging Chain in Optical Astronomy

The Imaging Chain in Optical Astronomy

1.6 Beam Wander vs. Image Jitter

Eric B. Burgh University of Wisconsin. 1. Scope

GLAO instrument specifications and sensitivities. Yosuke Minowa

Photometry using CCDs

NIRCam Instrument Overview

LSST All-Sky IR Camera Cloud Monitoring Test Results

Two Fundamental Properties of a Telescope

Improving the Collection Efficiency of Raman Scattering

Optical design of MOIRCS

Spotlight 150 and 200 FT-IR Microscopy Systems

3.0 Alignment Equipment and Diagnostic Tools:

Instructions for the Experiment

CONFIGURING. Your Spectroscopy System For PEAK PERFORMANCE. A guide to selecting the best Spectrometers, Sources, and Detectors for your application

VERY LARGE TELESCOPE

Subject headings: turbulence -- atmospheric effects --techniques: interferometric -- techniques: image processing

Spatially Resolved Backscatter Ceilometer

Light gathering Power: Magnification with eyepiece:

TIRCAM2 (TIFR Near Infrared Imaging Camera - 3.6m Devasthal Optical Telescope (DOT)

Phase-2 Preparation Tool

Astr 535 Class Notes Fall

Southern African Large Telescope. Prime Focus Imaging Spectrograph. Polarimetric Optics Design Study

Image Slicer for the Subaru Telescope High Dispersion Spectrograph

Photometry. La Palma trip 2014 Lecture 2 Prof. S.C. Trager

Potential benefits of freeform optics for the ELT instruments. J. Kosmalski

Better Imaging with a Schmidt-Czerny-Turner Spectrograph

NGAO NGS WFS design review

NIRCAM PUPIL IMAGING LENS MECHANISM AND OPTICAL DESIGN

Solar Optical Telescope (SOT)

Scaling relations for telescopes, spectrographs, and reimaging instruments

Oriel Cornerstone 130 1/8 m Monochromator

THE CALIBRATION OF THE OPTICAL IMAGER FOR THE HOKU KEA TELESCOPE. Jamie L. H. Scharf Physics & Astronomy, University of Hawai i at Hilo Hilo, HI 96720

105 Space Sciences Building, Ithaca, NY, USA Building N232, Moffett Field, CA, USA ABSTRACT 1. INTRODUCTION

Radiometric Solar Telescope (RaST) The case for a Radiometric Solar Imager,

UNIVERSITY OF HAWAII Institute for Astronomy. f/31 High Angular Resolution Imaging Spectrograph HARIS USER MANUAL update June 10, 1997

Classical Optical Solutions

Cynthia S. Froning, Jon Holtzmann, Matthew Beasley & Chris Burrows

NIRCam optical calibration sources

Optical Design of an Off-axis Five-mirror-anastigmatic Telescope for Near Infrared Remote Sensing

Current Status of PS1 Sky Survey and Lulin 2-m Telescope

Properties of a Detector

Cornerstone 260 1/4 m Monochromators

FPPO 1000 Fiber Laser Pumped Optical Parametric Oscillator: FPPO 1000 Product Manual

Cardinal Points of an Optical System--and Other Basic Facts

Transcription:

Simultaneous Infrared-Visible Imager/Spectrograph a Multi-Purpose Instrument for the Magdalena Ridge Observatory 2.4-m Telescope M.B. Vincent *, E.V. Ryan Magdalena Ridge Observatory, New Mexico Institute of Mining and Technology, 401 Leroy Place, Socorro, NM, USA, 87801-4681 * mvincent@mro.nmt.edu, phone (505) 835-6758

ABSTRACT The Simultaneous Infrared-Visible Imager/Spectrograph (SIRVIS) is a planned multi-purpose instrument for the Magdalena Ridge Observatory 2.4-m telescope located west of Socorro, NM. The primary science drivers are asteroid studies, the rapid response to astrophysical transient phenomena and observations of artificial targets such as satellites. For asteroid science, the wavelength range 0.39-2.5 μm gives the most mineralogically diagnostic information on surface compositions using standard filters and low-resolution, R ~ 200, spectroscopy. For transients, the telescope's rapid 10 /second slew rate will facilitate acquisition of data on any target within one minute of receipt of notice. For artificial targets, simultaneous two-color imaging will assist in unique determinations and overall condition monitoring. SIRVIS has two channels, a cryogenic NIR channel covering 0.85-2.5 μm at 0.27 arcsec/pixel, and an ambient temperature-pressure visible channel covering 0.39-1.0 μm at 0.15 arcsec/pixel. The beam is split by a cryogenic, redpass dichroic mirror located between the telescope focal plane and the respective collimators. Both channels use refractive optics. The instrument is being designed to initially phase in the visible channel, then the NIR channel, and readily accommodate upgrades. For sky subtraction, the telescope is nodded between 30-60 second NIR integrations. Long visible integrations are made possible by shifting the CCD charge in sync with the nod.

SIRVIS Serves Three Scientific Functions 1) Photometry to measure the brightness of a target in selected filters. * Simultaneous visible and NIR photometry to derive colors. * Atmospheric extinction corrections are simplified as both channels observe through the same airmass. * 3 σ detections of V (0.55 μm) 22.5 and J (1.25 μm) 19.0 targets in 10 second long images. * 3 σ detections of V 25.0 and J 21.5 targets in 10 minute long images. * 1% photometry on V 21.5 and J 18.0 targets in 10 minute long images. 2) Spectroscopy for surface material characterization and temperature measurements. * The visible and NIR spectra offer continuous coverage from 0.39-2.5 μm. * Overlap in the ~ 0.85-1.00 μm range simplifies cross-calibration of the visible and NIR spectra. * Low resolution spectra maximizes sensitivity to faint targets, or shortens exposures of brighter targets. * R~200 (R is λ/δλ) spectroscopy is sufficient to identify the mineral content of small bodies or surface materials of artificial satellites. * Can measure the black body temperature of warm and hot targets. 3) Astrometry to measure the position and motion of targets. * The low, <0.1%, geometric distortion simplifies the measurement of a target's position with respect to reference objects in the same field. * Relative astrometry accurate to <0.1 arcseconds across the full field of either channel.

OPTICS Our design principle is to combine a conventional ambient-temperature visible channel and a cryogenic NIR channel in an simple way. Each channel is optimized for stand-alone operations. Simultaneous use of the two channels is facilitated by an insertable cold (T < 120 K), red-pass dichroic mirror (fig. 1). Dichroic cut-off is near 1.14 μm, and optional second near 0.88 μm. The dichroic substrate is wedged to minimize astigmatism in the NIR channel. Both channels use refractive optics to deliver to deliver 80% encircled energy in 2 pixel diameter spots at all wavelengths across most of the field without the need to refocus, and geometric distortion less than 0.1% in both channels. Spectroscopy is facilitated by a slit at the telescope focal plane and grisms near the pupil plane. SIRVIS Channel Characteristics Visible NIR Detector 2K 2K CCD 1K 1K HgCdTe Wavelength Coverage (µm) 0.39-1.00 0.85-2.50 Field of View (arcminutes) 5.0 5.0 4.7 4.7 Pixel Scale (arcseconds pixel -1 ) 0.15 0.27 Pixel Size (µm) 15 18 Effective f/# f/8.8 f/5.7 Pupil Diameter (mm) 21 21 Filter Diameter Range (mm) 25-32 25-32

OPERATING MODES SIRVIS has a number of possible operating modes and expansion options: two-color imaging (fig. 1), spectroscopy (fig. 2), an expansion to include an occultation and tracking detector (fig. 3), and an expansion to add a blue channel (fig. 4). The visible channel can be implemented as an in-line design (i.e. no fold mirrors) before the NIR channel is finished. This versatility is achieved through a simple, modular design. SKY SUBTRACTION One of the complicating factors in simultaneous NIR and visible imaging is the discrepancy in the sky constant times. For adequate NIR sky subtraction, the duration of the integrations is limited to a maximum of about one minute by variations in the JHK s sky levels. After this time, the telescope or secondary mirror must be nodded five to tens of arcseconds off target to start another integration, or series of integrations. High signal to noise visible integrations, though, may require several tens of minutes. We propose a solution that would minimize CCD read noise without using moving optics within SIRVIS. The bi-directional vertical charge shifting capability of certain CCDs can be utilized to shift the charge to remain beneath the optical image through multiple nods. During a nod, the shutter is closed and the CCD is clocked to shift the charge along a column depending upon the direction and size of the nod. The CCD is oriented such that the columns are parallel to the slit. Further aiding this technique are the optics' low geometric distortion that will eliminate blurring between nodes as the plate scale remains constant across the array.

INSTRUMENT and OBSERVATORY STATUS SIRVIS is in the design stage. The optics are being designed using Zemax-EE. The optical bench and Dewar will be designed around the optics. The Magdalena Ridge Observatory 2.4 m, f/8.8 telescope is on schedule for first light in September 2006. The 40' Observa-Dome (Jackson, MS) passed its factory acceptance test on May 9. The telescope FAT is on track for July 17-21 at EOS Technologies, Inc. (Tucson, AZ), see poster "Magdalena Ridge Observatory 2.4-m Telescope", G. Pentland, et al., #6267-104. The telescope site acceptance test is scheduled for completion on September 26, 2006. The initial instrumentation will consist of a 4K 4K CCD mounted at the Nasmyth instrument port derotator. A f/7.5 focal reducer will be added shortly thereafter to provide a square 11.7 arcminute field of view. A filter wheel box holding ten 100 mm square filters is currently being fabricated at New Mexico Tech for our CCD and visiting instruments. The telescope offers a generous 325 mm spacing between the Nasmyth port flange and the telescope focal plane to accommodate a wide range of instruments. For more details of the Magdalena Ridge Observatory, please see our website at: http://www.mro.nmt.edu/ Webcam at: http://www.mro.nmt.edu/2.4m/webcam/ Panoramas at: http://infohost.nmt.edu/~mvincent/mro_panoramas/

Figure 1. Two-Channel Imaging Mode. The dichroic mirror reflects visible light out of the Dewar, and transmits NIR. A NIR blocking filter inside of the exit window minimizes the stray radiation entering the NIR channel and reduces heat load to the Dewar. The cryogenic slit plates and dichroic mirrors are located on wheels, and are rotated in/out of the optical path. The ambient temperature channel allows the use of standard visible filters no need for custom, cryogenic filters.

Figure 2. Two-Channel Spectroscopy Mode. A mirrored slit plate is rotated into the telescope focal plane. The slit length is perpendicular to the page. Light not entering the slit is reflected to the slit viewing channel. As shown, the slit viewer light path is an ambient temperature channel, though it may be configured as a cryogenic channel. Grisms are located in the rear filter wheels. Simultaneous slitless visible spectroscopy and NIR imaging is also possible on visible bright, NIR dim targets.

Figure 3. Expansion to Occultation and Tracking Mode. This mode requires frame rates in excess of 100 second -1. To achieve this, a dedicated visible channel detector is required since the 2K 2K CCD cannot reach the necessary rates. A flip mirror is quickly inserted between the visible camera optics and the CCD to redirect light. The NIR array is inherently high frame rate, especially when windowed. Both channels are designed to have ample space between the last element of the camera optics and the detector.

Figure 4. Expansion to Three Channels. The visible channel fold mirror is replaced with a blue-pass dichroic mirror. The blue-channel is optimized for 0.33-0.55 μm. The visible channel collimator is designed to operate over 0.33-1.00 μm. Two different dichroics with cutoffs at 0.43 and 0.55 μm are required to use both the Johnson-Morgan UB and SDSS u'g' filters. To provide clearance between the blue detector and the NIP flange, a fold mirror may be placed behind the dichroic.