Reactor and inductor are names used interchangeably for this circuit device.

Similar documents
This Manual Part recommends design criteria for resistors suitable for railway signaling circuits other than electronic.

2. Conductor insulation should be supported and gripped by the terminal.

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Howard Smart Transformer Specification Guide

Iron Powder Core Selection For RF Power Applications. Jim Cox Micrometals, Inc. Anaheim, CA

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

TRAFTOR WINDINGS CHANGING THE RULES TOROIDAL INDUCTORS & TRANSFORMERS SOLUTIONS PROVIDER AND MANUFACTURER

Bridgeport Magnetics Design Guide

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Transformer Factory Testing

FERRORESONANT PROGRAM MANUAL V12.0

Curve accuracy (enough data points to be statistically significant): See Attachment B.

INTERNATIONAL STANDARD

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Basic Principles and Operation of Transformer

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

(2) New Standard IEEE P (3) Core : (4) Windings :

Section 2 Outdoor Voltage Transformers

7. INSPECTION AND TEST PROCEDURES

Power Processor - Series 700F 10KVA to 150KVA

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Dry-Type Transformers

Review 6. unlike poles cause the magnets to attract. like poles cause the magnets to repel.

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

AT Current Instrument Transformer Instructions for installation, use and maintenance

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

What is an Inductor? Token Electronics Industry Co., Ltd. Version: January 16, Web:

2013 Applied Power Electronics Conference (APEC) Page 1 of 8

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Sales: Technical: Fax:

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

TECHNICAL SPECIFICATION OF ELECTRICAL MATERIALS CT & PT GROUP C

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

Iron Powder Cores for High Q Inductors By: Jim Cox - Micrometals, Inc.

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

Magnetics Design. Specification, Performance and Economics

Loop & Magnetic Field Coil

Power Transformers Basics

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

Line Frequency Transformer

SECTION TRANSFORMERS

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Electrical Design Process

PRODUCT SPECIFICATION

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

West Coast Magnetics. Advancing Power Electronics FOIL WINDINGS FOR SMPS INDUCTORS AND TRANSFORMERS. Weyman Lundquist, CEO and Engineering Manager

METER - INSTALLATION Pad Mount Transformer

35 kv Class M.O.V.E. DirectConnect elbow arrester

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

Glossary of Common Magnetic Terms

Liquid-Filled Transformers

SINGLE-PHASE VSV SWITCH

Level 3 Physics, 2018

REPORT OF PERFORMANCE TIC

Status Date Prepared Reviewed Endorsed Approved

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Basics of electrical transformer

HIGH FREQQUENCY TRANSFORMER DESIGN PROGRAM MANUAL V12.0

FIGURE 1. Design, dimensions, and circuit diagram.

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

A Fresh Look at Design of Buck and Boost inductors for SMPS Converters

Field Instrument Cable. Electrical Noise

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

Semiconductor contactors, Solid-state relays

HPS Universal BUCK-BOOST TRANSFORMERS

TMC Transformers TMC

MTE training MTE Corporation

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

TRANSFORMER TECHNOLOGY GPT

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

The Reflective Wave Phenomena

Effects of Harmonic Distortion I

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Transcription:

Recommended Design Criteria for Air-Cooled Reactor for Line and Track Circuits Revised 2015 (7 Pages) A. Purpose This Manual Part recommends design criteria for an air-cooled reactor for line and track circuits. Reactor and inductor are names used interchangeably for this circuit device. This Manual Part also applies to three phase reactors. Ernie Schoop 10/21/13 5:31 PM Ernie Schoop 11/1/13 3:58 PM 6 Ernie Schoop 10/21/13 5:31 PM See Manual Part 1.4.1 (Identical Items "Boilerplate" for all Manual Parts), Coil Insulation and Binding Posts. B. Basic Recommendations The following features should be considered: 1. Frequency. 2. Rated voltage ac and dc. 3. Rated current ac and dc. 4. Rated inductance. 5. Resistance ac and dc. 6. Method of impedance adjustment, by tap selection or by variation of air gap distance. 7. Details of electrified propulsion, and whether single-rail or double-rail track circuits. 8. Whether iron-core or air-core. 9. Linearity. 10. Saturation. C. Design Criteria 1. Service Conditions * Equipment referred to in these recommendations shall be suitable for operation at its rating provided that: Ernie Schoop 11/1/13 4:47 PM * a. The temperature of the cooling air (ambient temperature) does not exceed +104 F (+40 C) and the average temperature of the cooling air for any 24-hour period does not exceed +86 F (+30 C). b. The altitude does not exceed 3300 ft. * See Appendix A of Manual Part 14.2.10 Recommended Design Criteria for Transformer, Dry-Type, Air- Cooled for operation under special service conditions. - 1

Part 14.2.20 2015 * 2. Type Reactor should be designed for indoor or outdoor service, as specified. 3. Windings 4. Core a. Windings should consist of insulated copper or aluminum wire. The insulation shall be selected on the basis of the unit s temperature rating and its voltage gradients within the windings. b. Wire should be selected on the basis of the unit s current rating and its frequency of operation. Multiple strands of wire or Litz wire should be used when high frequency currents are expected. c. If winding has taps for inductance changes, these should be plainly marked and identified. Reactor should be designed either with a metal core or no core at all (aircore). The selection is a function of frequency, linearity and saturation values required, a. If a core is used, it should be manufactured of laminated sheet steel as specified in International ASTM Standards: A876-12 Standard Specification for Flat-Rolled, Grain Oriented, Silicon Iron, Electrical Steel, Fully Processed, A677-05 Standard Specification for Nonoriented Electrical Steel Fully Processed Types, A683-05(2010) Standard Specification for Nonoriented Electrical Steel, Semiprocessed Types and A901-12 Standard Specification for Amorphous Magnetic Core Alloys, Semi-Processed Types. b. Common designations for these electrical steels are M-1 through M-45 which have been superseded and expanded by more descriptive designations contained in the above mentioned International ASTM Standards. Additionally, cores can also be manufactured with very low core loss material made of amorphous steel described as Metglas 2605 SA1 Alloy or similar. Steel thickness may vary from 0.0007 in through 0.0250 in. c. The selection of the steel to be used is a function of the frequency of operation, core-loss, saturation and exciting characteristics and permeability. - 2 Ernie Schoop 10/31/13 6:47 AM Ernie Schoop 11/1/13 4:48 PM See Appendix A of Manual Part 14.2.10 (Recommended Design Criteria for Transformer, Dry-Type, Air-Cooled) for operation under special service conditions. Ernie Schoop 11/1/13 4:50 PM Formatted: Indent: Left: 0" Ernie Schoop 10/21/13 5:39 PM 03 Ernie Schoop 10/21/13 5:39 PM Ernie Schoop 10/21/13 5:39 PM Ernie Schoop 10/21/13 5:40 PM e1 Ernie Schoop 10/21/13 5:40 PM Ernie Schoop 10/21/13 5:40 PM -O Ernie Schoop 10/21/13 5:41 PM, Ernie Schoop 10/21/13 5:41 PM Ernie Schoop 11/2/13 5:46 PM e1 Ernie Schoop 10/21/13 5:42 PM Ernie Schoop 10/21/13 5:42 PM -O Ernie Schoop 10/21/13 5:42 PM -P Ernie Schoop 10/21/13 5:43 PM Ernie Schoop 10/21/13 5:43 PM 03 Ernie Schoop 10/21/13 5:43 PM Ernie Schoop 10/21/13 5:44 PM Ernie Schoop 10/31/13 6:51 AM 2 Ernie Schoop 10/21/13 5:44 PM 27 Ernie Schoop 12/25/13 1:51 PM.

5. Rating Reactor shall be rated conforming to its voltage, current and inductance characteristics as follows: a. Voltage rating shall be the maximum voltage at required frequency which may be applied across the entire winding. b. Current rating shall be the maximum current which any part of the entire winding will carry continuously at any up to rated voltage and required frequency. Intermittent and special duty cycle ratings may be required. c. Inductance rating shall be the inductance of the entire winding expressed as a function of required current and frequency. d. Inductance may be specified to be able to be adjusted. Inductance adjustment may be accomplished either by varying the gap (if ironcore) or by winding tap selection (iron or air-core). 6. The temperature rise of any part of the reactor winding shall not exceed the specified temperature rise above ambient temperature and shall fall within the limits of its insulation temperature system class. 7. Binding Posts, Leads and Terminals a. Binding posts shall conform to Manual Part 14.1.11 Recommended Design Criteria for Binding Posts, Nuts and Washers, Details & Assemblies and Manual Part 14.1.12 Recommended Design Criteria for Standard Binding Posts b. Where the winding conductor is of smaller cross-section than No. 14 AWG (2.08 mm 2), a flexible conductor of not less than No. 16 AWG (1.31 mm 2 ) shall be used between winding and binding post or terminal. c. Reactors wound with No. 10 AWG (5.26 mm 2 ) or larger wire may be furnished, when specified, without binding posts, in which case the leads shall be provided of sufficient length and with suitable connectors for attaching to external conductors.. Ernie Schoop 11/15/13 2:12 PM.. d. Reactors for outdoor use shall have leads and bushings sealed into the case with a compound which is temperature and environment compatible with the location of the reactor. - 3

Part 14.2.20 2015 e. All start and finish leads shall be spaced far enough apart to ensure no dielectric breakdown occurs when inductive energy collapses. It may be necessary to connect a voltage suppressor across the leads to limit the potential. 8. Insulation Winding insulation shall conform to Manual Part 15.2.4 Recommended Selection and Application Criteria of Insulating Materials Used in Coils for Magnetic Assemblies and in Other Electrical Devices. D. Dielectric Requirements E. Tests 1. See Manual Part 15.2.5 Recommended Dielectric Requirements for the Design and Installation of Electrical Equipment and Other Electrical Devices. 2. See Manual Part 11.5.1 Recommended Environmental Requirements for Electrical and Electronic Railroad Signal System Equipment, Class C. 3. A surface tracking leakage distance of not less than 3/8 in (9.53 mm) shall be provided between any exposed metallic part of the apparatus carrying current or having electrical potential and any other metallic part thereof. 4. Because reactors are subjected to a variety of voltage stresses, the references noted in Sections D.1, D.2 and D.3 may be superseded by the user s specifications. 1. Inductance Because inductance measurements are dependent on the circuit application, they are generally specified by the user. The four different principal measurement methods are: a. With an inductance bridge; b. by calculating from voltage, current and frequency readings; c. by calculating from a tuning circuit and d. by applying a step function signal. If required, inductance saturation values shall be tested by: - 4 Ernie Schoop 10/31/13 6:47 AM Ernie Schoop 11/1/13 3:22 PM. Ernie Schoop 11/1/13 3:33 PM Formatted... [1] Ernie Schoop 11/1/13 3:22 PM 1.4.1, Coil Insulation Ernie Schoop 11/1/13 3:22 PM... [2] Ernie Schoop 11/1/13 3:32 PM Formatted... [3] Ernie Schoop 11/1/13 3:25 PM 1.4.1, Dielectric Requirements. Ernie Schoop 11/1/13 3:26 PM Ernie Schoop 11/1/13 3:32 PM Ernie Schoop 11/1/13 3:33 PM Ernie Schoop 11/1/13 3:36 PM. Ernie Schoop 11/1/13 4:51 PM is Ernie Schoop 11/1/13 4:54 PM method used it is three Formatted... [4] Ernie Schoop 11/1/13 4:56 PM Formatted... [5] Formatted... [6] or Formatted... [7] Formatted... [8]. Formatted... [9] Formatted... [10]

a. Increasing voltage across the unit as specified for an ac inductor, or b. Increasing the dc bias current through the unit as specified for a dc inductor. 2. Losses Only load losses can be measured in an inductor. This should be accomplished by using a low power factor ac wattmeter (for ac units), and by calculation of voltage times current (for dc units). 3. Temperature rise. Ernie Schoop 11/1/13 5:14 PM a. Inductors of each new design should be tested for temperature rise. b. When testing for temperature rise, inductors may be overloaded to hasten the rise of temperature of the ultimate value under normal load, and final temperature in any part maintained for one hour under constant full load and normal voltage and frequency shall not exceed the temperatures shown in Table 14210-1. The rise of temperature of ac inductors should be determined by the increase of resistance of the windings by the methods given in ANSI/IEEE C57.12.91-2011 Standard Test Code for Dry-Type Distribution and Power Transformers and for dc inductors by the increase of resistance as computed from voltage divided by current readings. Other readings may be taken by thermometer or thermocouple. Table 14210-1: Limits of Temperature and Temperature Rise for Continuously Rated Dry-Type Inductor Windings* Insulation-System Temperature ( C) Average Winding-Temperature Rise by Resistance ( C) Formatted: Body Text Indent 3, Indent: Left: 1.5", Tabs: 1.5", Left Ernie Schoop 11/1/13 5:10 PM 2001 Ernie Schoop 11/1/13 5:11 PM Ernie Schoop 11/1/13 5:11 PM Ernie Schoop 11/1/13 5:15 PM Formatted: Centered 130 150 185 200 220 60 80 115 130 150 *This table does not recognize the different hottest spot allowance that may exist in certain applications. Based on a maximum ambient temperature of 40 C. Higher average winding temperature rises by resistance may apply if the manufacturer provides thermal design test data substantiating that temperature limits of the insulation class are not exceeded. - 5

Part 14.2.20 2015 4. Dielectric Tests F. Identification a. The applied-potential test shall be made by applying between each winding separately, and all other windings and ground, a 60 Hz voltage from an external source. The winding under test shall be shorted during the test. All other circuits and metal parts shall be grounded during the test. If the inductor is of air-core construction, ground planes shall be simulated to perform this test. b. The duration of the applied-potential test shall be for 1 min at the value specified in procedure below. c. The rms test voltage shall be 3,000 volts or as specified. The rms test voltage shall be applied at a rate not to exceed 1,000 volts/second. d. Turn to turn insulation shall be tested by applying an impulse wave e.g. by capacitor discharge at a level specified or by agreement between user and manufacturer. The duration of this impulse shall not exceed 75 microseconds. 1. A nameplate should be securely fastened or adhered to each reactor and should give the following information: a. Name of manufacturer. b. Inductance to include all taps. Ernie Schoop 10/31/13 6:47 AM Ernie Schoop 11/1/13 5:01 PM. Ernie Schoop 11/1/13 5:03 PM Formatted: Justified Ernie Schoop 11/1/13 5:03 PM Formatted: Justified Ernie Schoop 11/1/13 5:01 PM Volts Ernie Schoop 11/1/13 5:01 PM Volts Ernie Schoop 11/1/13 5:02 PM ec Formatted: Normal, Justified, Indent: Left: 1", Hanging: 0.5", Numbered + Level: 1 + Numbering Style: a, b, c,... + Start at: 1 + Alignment: Left + Aligned at: 1.19" + Indent at: 1.44", Tabs: 1.5", Left c. Rated voltage and current. d. Dc resistance e. Frequency. f. Serial number. g. Manufacturer s reference number. 2. As an alternate to the nameplate, the required information listed above should be engraved or stamped on the unit. - 6

3. A plate or tag should be securely fastened or adhered to each reactor and should show connection diagram, impedance value between various leads where adjustment is by tap selection and impedance value corresponding to maximum and minimum air gap distance where adjustment is by air gap. - 7