Advantages. Applications

Similar documents
Electronic relays. Monitoring. Monitoring

Switching power supplies CP range, Linear power supplies CP-L range. Content

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800)

Type CP-S, CP-C & CP-A Switch mode

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

XR1 Rotor Earth Fault Relay. (May 2007) Manual XR1 (Revision New)

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

ZITARES ICD SELV constant current control gear, 2-channel, dimm- and programmable

XR1 Rotor Earth Fault Relay. Manual XR1 (Revision C)

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

XUA1 AC Voltage and phase balance relay. (August 1996) Manual XUA1 (Revision New)

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

EMD-FL-3V-400. Electronic monitoring relay for voltage monitoring in three-phase networks. INTERFACE Data sheet _en_03. 1 Description.

XUA1 - AC Voltage and phase balance relay

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

20 General technical data XI/ON

For Immediate Delivery call KMParts.com at (866)

Transformers, Power Supply Units and Socket Outlets

ZITARES NCS 2 nd Generation Non-SELV, Constant current control gear, 1-channel, non-dimmable

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

CP-E range Benefits and advantages

Current monitor Type C 551

E-STOP relays, safety gate monitors

Operating Manual NS20K

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

Protection and safety SQZ3 phase and sequence relay

CP-T range Product group picture

Coupling Relays and Converters

ZITARES CC Constant current control gear, 2-channel, dimmable

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

CP-T range Benefits and advantages

ZITARES LCS Non-SELV, Constant current control gear, 1-channel, non-dimmable

MINI-PS AC/2X15DC/1

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Type: DILM40(RDC24) Article No.:

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

SAMSUNG ELECTRO-MECHANICS CO., LTD

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Three-phase monitoring relays

Power supply CP-E 24/2.5

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 24/20.0

Universal signal transducer UKU

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply

Industrial Controls. Catalog IC SIRIUS. Answers for industry.

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC71, PPC71

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply

PSR-SCP- 24DC/ESD/5X1/1X2/300

IsoTrans 41. The load capability of the 20 ma source is limited and therefore requires efficient use of the load voltage.

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Safety Technique. Emergency Stop Module With Time Delay BH 5928, BI 5928

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

XU2-AC AC voltage relay. (Februar 1997) Manual XU2-AC (Revision New)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

General. Efficiency Isolation. Dimensions Net Weight. Safety & EMC

Monitoring Relays True RMS 3-Phase, 3-Phase+N, Multifunction Types DPC01, PPC01

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

ZITARES CCD FX-20 25W SELV (isolated), adjustable functions and current, 1-channel, dimmable

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Output of three-phase motors at 50 Hz and 400 V

EN 50178, IEC

Control module CP-A CM

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

Pluggable interface relays CR-P Pcb relays

Safety Technique. SAFEMASTER Emergency Stop Module With Time Delay BH 5928, BI 5928

ZITARES NCD 2 nd Generation Non-SELV, constant current control gear, 1-channel, dimmable

DSR120 Series. xxx Series. 120 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details

ProLine P Precise Temperature Measurement at High Voltage Potentials up to 6.6 kv

* Short-circuit detection at On pushbutton. Applications. Indication. S M6801_a S11 A3 S12 S21 S23 S22 S (+)

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

Electronic Step Controller

QUINT-PS/ 3AC/24DC/10

Power Electronics. POWERSWITCH Solid-State Contactor BF 9250, BH 9250

The EVI 30/8 coils can be equipped with the suitable plunger guide tube (see S8 - S9 Catalogue).

LED Driver Compact fixed output

Power Electronics. POWERSWITCH Semiconductor Contactor BF 9250, BH 9250

PTC-resistor relay type MS 220 K and MSR 220 K PTC-resistor trip device

Primary switch mode power supplies Product group picture

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Theta Hz. Technical Data Sheet. Special Features

J IPC IGBT power converter

Totalizing Counters mini-i

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Transcription:

3 s KH 250 General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 250 VA Ambient temperature +40 C Degree of protection IP 40 Advantages Compensation for mains voltage fluctuations Attenuation of asymmetric interference voltage peaks Bridging voltage dips Galvanic isolation from the mains Short-circuit proof No-load proof RF interference-free Service-free Applications Magnetic voltage stabiliser securing the supply voltage in the event of mains overvoltage, mains undervoltage, voltage dips and voltage surges and in the case of brief voltage interruptions. StandardsZ Approvals J Z Magnetic voltage stabiliser acting as mains transformer in accordance with VDE 0570 part 2-12, EN 61558-2-12; IEC 61558-2-12 565

3 s KH 250 Typ KH 250 Rated input voltage 2 Vac Permissible tolerance (Input voltage) +10 % to -20 % Rated output voltage 2 Vac Rated current A Rated frequency 50 Hz Permissible tolerance (Frequency) ±1 Hz Response time typ. 3 line periods (60 ms) Rated Power 250 VA Ambient temperature max. 40 C Type Resin encapsulated transformer Insulation class A Protection index IP 40 Safety class (prepared) II Short circuit strength short-circuit proof Test voltage 3750 Vac, 50 Hz Order Number KH 250 Terminals Input Terminals Weight Dimension (W x H x D) Mains lead, 2 m long with moulded plug Socket 11.70 kg Dimension picture (in mm) 1 145 x 200 x 245 mm A 245 B 145 C 200 566

3 s General Data Rated input voltage 2 Vac Rated output voltage 2 Vac Rated power 60-00 VA Degree of protection IP 00 Ambient temperature +40 C Advantages Compensation for mains voltage fluctuations Attenuation of asymmetric parasitic voltage peaks Bridging momentary voltage dips May be switched between high control precision and elevated parasitic voltage attenuation Galvanic isolation from the mains Short-circuit proof No-load proof RF interference free Applications securing the supply voltage in the event of mains overvoltage, mains undervoltage, voltage dips and voltage surges and in the case of brief voltage interruptions. StandardsZ Magnetic voltage stabiliser acting as mains transformer in accordance with VDE 0570 part 2;2-12, EN 61558-1; 2-12, IEC 61558-1;2-12 567

3 s Typ 60 120 250 500 800 1000 Rated input voltage 2 Vac 2 Vac 2 Vac 2 Vac 2 Vac 2 Vac Permissible tolerance (Input voltage) +10 % to - % +10 % to - % +10 % to - % +10 % to - % +10 % to - % +10 % to - % Rated output voltage 2 Vac 2 Vac 2 Vac 2 Vac 2 Vac 2 Vac Rated current 0.26 A 0.52 A 1.01 A 7 A 3.48 A 4.34 A Rated frequency 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz 50 Hz Harmonic content <4 % at ohmic load <4 % at ohmic load <5 % at ohmic load <5 % at ohmic load <5 % at ohmic load <5 % at ohmic load Stored energy time at rated load 10 ms 10 ms 10 ms 10 ms 10 ms 10 ms Correction time 20-60 ms 20-60 ms 20-60 ms 20-60 ms 20-60 ms 20-60 ms Rated Power 60 VA 120 VA 250 VA 500 VA 800 VA 1000 VA Ambient temperature max. 40 C 40 C 40 C 40 C 40 C 40 C Type Enclosed Enclosed Enclosed Enclosed Enclosed Enclosed Insulation class E E E E E E Protection index IP 00 IP 00 IP 00 IP 00 IP 00 IP 00 Safety class (prepared) I I I I I I Short circuit strength short-circuit proof short-circuit proof short-circuit proof short-circuit proof short-circuit proof short-circuit proof Test voltage 3550 Vac, 50 Hz 3550 Vac, 50 Hz 3550 Vac, 50 Hz 3550 Vac, 50 Hz 3550 Vac, 50 Hz 3550 Vac, 50 Hz Order Number 60 120 250 500 800 1000 Fixing method Fixing rail Fixing rail Fixing rail Fixing rail Fixing rail Fixing rail Terminals Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals Screw-type terminals Weight 3.60 kg 6.40 kg 11.00 kg 15.50 kg 22.00 kg 31.00 kg Dimension picture (in mm) 1 1 1 1 1 1 A 212 232 266 288 318 287 B 75 100 147 147 147 210 C 138 181 216 216 216 2 D 92 120 165 165 165 235 E 58 59 66 88 118 82 F 190 210 242 264 294 261 G 66 66 140 140 140 162 H - - - - - 340 568

3 s Typ 1500 2000 00 Rated input voltage 2 Vac 2 Vac 2 Vac Permissible tolerance (Input voltage) +10 % to - % +10 % to - % +10 % to - % Rated output voltage 2 Vac 2 Vac 2 Vac Rated current 6.52 A 8.7 A 13 A Rated frequency 50 Hz 50 Hz 50 Hz Harmonic content <5 % at ohmic load <5 % at ohmic load <5 % at ohmic load Stored energy time at rated load 10 ms 10 ms 10 ms Correction time 20-60 ms 20-60 ms 20-60 ms Rated Power 1500 VA 2000 VA 00 VA Ambient temperature max. 40 C 40 C 40 C Type Enclosed Enclosed Enclosed Insulation class E E E Protection index IP 00 IP 00 IP 00 Safety class (prepared) I I I Short circuit strength short-circuit proof short-circuit proof short-circuit proof Test voltage 3550 Vac, 50 Hz 3550 Vac, 50 Hz 3550 Vac, 50 Hz Order Number 1500 2000 00 Fixing method Fixing rail Fixing rail Fixing rail Terminals Screw-type terminals Screw-type terminals Screw-type terminals Weight 43.00 kg 56.00 kg 82.00 kg Dimension picture (in mm) 1 1 1 A 325 418 485 B 210 210 210 C 2 2 2 D 235 235 235 E 120 153 220 F 299 392 459 G 162 162 162 H 340 340 340 569