spy pig Tracking systems

Similar documents
spy pig Tracking systems

OPERATING INSTRUCTIONS

StarTrak Pigging Technologies

I N N O V A T I N G U N D E R G R O U N D L O C A T I N G

Schonstedt Magnetic Locators

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

F I S H E R R E S E A R C H L A B O R A T O R Y

CD42-STS Operating Manual Diver/ROV Pipeline Pig Location & Tracking System

TW-82 TW-82 ACCESSORIES. Operating Manual DIGITAL LINE TRACER F I S H E R R E S E A R C H L A B O R A T O R Y

STARTRAK PIGGING TECHNOLOGIES, INC. PIPELINE PIG MONITORING

PT-1. Pipe Tracker OPERATION MANUAL 1010 JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

UAT-600 Series. amprobe.com

Applications Features

pipeline integrity PCM + Pipeline Current Mapper

TRACKING. ABOVE GROUND MARKER Pg RECEIVERS Pg TRANSMITTERS Pg. 8-3 to 8-5. GEOPHONE Pg DELRIN CANS Pg RENTALS Pg.

Pipeline Current Mapper

TX-1AA TRANSMITTER. Note:

Electro-Magnetic Flowmeters COPA-XE

ELECTROMAGNETIC RECEIVER TOPSIDE OPERATING MANUAL

4. BASIC OPERATION AND DESCRIPTION

Instruction Manual. Model GA-52Cx Magnetic Locator

PNEUMATIC, ELECTRO-PNEUMATIC & SMART DIGITAL.

FX-3. Operating Manual. Q U A L I T Y Fisher detectors are renowned for their quality. Each detector is hand crafted in the USA with pride

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Installation & Operation Manual

Wireless Gas Detection System

Instruction Manual. Model GA 92 XTd Magnetic Locator

CD42-STS Subsea Diver/ROV Pig Location and Tracking System

Sound Meter Type

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

AT-7000 Advanced Wire Tracer

TW-82 TW-82 ACCESSORIES. Operating Manual Revision Level 1 DIGITAL LINE TRACER

TW-82. Operating Manual DIGITAL LINE TRACER. Revision Level 1

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

Instruction Manual. Model GA-52Cx Magnetic Locator

AT-4000 Advanced Tracer User s Manual

Instruction Manual. Model GA-52Cx

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Flow Technologies Overview. For internal use only / Siemens AG All Rights Reserved.

TW-82 DIGITAL LINE TRACER. Operating Manual

Introducing GPI s Latest

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

SEL Phase Comparison Faulted Circuit Indicator (PC FCI) Communicates to line crews using the. Features and Benefits

WIR TX90. SoundPlus Infrared Transmitter INFRARED SPECIFICATION DATA

KM3000 PORTABLE KEY MILL

Driveway Alarm INSTALLATION MANUAL

Ultrasonic Diagnostic Tool. Users Manual. Read this manual thoroughly before use

WATERFLUX 3000 Quick Start

Signet 9900 Transmitter

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

LT-700 Portable FM Display Transmitter

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

Proven Measurement for A World of Applications

Leica DIGISYSTEM TM Safe and fast location of underground services

Remote Controlled FOUNDATION Fieldbus Two-Wire ph/orp Transmitter

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

Instruction Manual. MAGGIE Magnetic Locator

Meriam Model M ma Loop Calibrator Operating Instructions

SFP-1 and MFP-1 PINGER

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

ELECTROMAGNETIC RECEIVER TOPSIDE ATEX OPERATING MANUAL

GC-1032 Metal Detector OWNER S MANUAL

Dynatel 2250E/2273E Advanced Cable and Fault Locator

WaveNet. Wireless Monitoring.

Ring Pair Corrosion Monitor : RPCM

3DLevelScanner. Technical Data Sheet. Level Sensor. Non-Contact, Multiple-Point Measurement

ProHUNTER OWNERS MANUAL

Beat the Competition. A Remote Will Make Your Crew work smarter not harder and earn more money!!!

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Acoustic Electric Guitar

Process Calibrator. TechChek 820

STAFF User Manual. Manual Part #

WIR TX90. SoundPlus Infrared Transmitter INFRARED SPECIFICATION DATA

WRZ-RMT10K-0 Wireless Remote Temperature Transmitter

Kotron Model 82 CE RF Level Transmitter

TraceMaster. Pipe and Cable Locator Multi-Frequency Receiver and Radio Linked to Transmitter. Instruction Manual

Echotel Model 910 Ultrasonic Level Switch

Treasure Cove Metal Detector

Fisher 4200 Series Electronic Position Transmitters

The Rosemount 848T Wireless Temperature Transmitter

Signet 9900 Transmitter

AT-4000 Series. Advanced Wire Tracer. Users Manual

i. AM. Radio Transmitter Installation and Operation Easy to follow instructions on how to program and use your Model 5.0 i. AM.

Cable I.D. Live. Primary or Secondary In or Out of the Trench TX-Former to TX-Former TX-Former to Meter Energized or Grounded.

The transducer component converts the measured signal and displays the actual value.

H201 中文 GB Version 1

DUNHAM & MORROW By Schonstedt Instrument Company Tel: Fax:

Preliminary Users Manual, Telex SAFE-1000 System.

PR-D5 中文 GB. Version 1

Signet 9900 Transmitter

WATERFLUX 3000 Quick Start

Rosemount 3101, 3102, and 3105

Electro-Mech Scoreboard Co. Product Guide

MSR/MSB Mechanical Setting Tool

Leica Digisystem Safe and fast location of underground services

Transcription:

spy pig Tracking systems

Spy pig Transmitters For the most reliable signal available, the SPY Pig Transmitter uses low frequency signals to effectively and consistently penetrate a steel pipe wall. We offer numerous transmitter sizes to cover a full spectrum of pipe diameters. Each transmitter is self-contained and travels inside various pigs, attached to versatile brackets, or towed. A hand-held receiver and wand are used to locate the transmitter. SPY TRANSMITTERS have been proven effective in the field for many years. Each SPY transmitter is designed and built for long reliable service. Rugged casing is liquid-tight. Battery operated. Coded signal minimizes false readings. Strongest signal available. Applications Mainline Transmission Gathering Lines Subsea Lines Municipal Gas Water and Wastewater Refining and the Process Industries Accessories PT107 MOUNTING CAP ITEM #13340 PT275 TOWING EYE ITEM #10818 PT275 MOUNTING CAP ITEM #12341 PT750 MOUNTING FLANGE ITEM #11374 3/4 WRENCH FOR PT275/750 CAP ITEM #11902 SHIPPING / CARRYING CASE FOR MODELS 2, 4, 12 & 23 HZ RECEIVE SYSTEMS ITEM #12726

Spy Non-intrusive pig tracking systems reliably and consistently track the passage of a pig or pinpoint its location. To locate a pig equipped with a SPY Transmitter, the SPY 23 HZ Receive (Pig Tracker Receiver and Wand) registers the changing magnetic field produced by any SPY Transmitter. When the Transmitter is located, the 23 HZ Receive produces both an audio and visual output. With two standard 9-volt alkaline batteries, the 23 HZ Receive can be powered continuously for approximately 50 hours. Special waterproof wands are available for sub-sea applications, with depths of up to 10,000 feet [3000 meters]. Visual LCD Signal Strength Display Shoulder Strap Clips Wand Plug Port Quick Change Battery Compartment Audible Signal Horn On /Off Bat Switch Battery Indicator Light ON (NEEDS BATTERIES) OFF (BATTERIES GOOD) Gain Knob SENSITIVITY ADJUSTER Benchtop Rubber Feet

Spy Non-intrusive pig tracking systems SPY offers two stationary Non-Intrusive Pig Tracking Systems (PTS & PTS-M) when the need for noting the passage of a pig becomes a little less temporary, (i.e.; manpower or distance prevents leap frogging). The model PTS for use with electromagnetic transmitters and the model PTS-M for use with magnet equipped pigs. NON-INTRUSIVE The PTS & PTS-M Systems are both non-intrusive systems that require NO HOLE to be drilled in the pipe. These non-intrusive systems allow for lower installation costs and significantly reduce the overall cost of the monitoring point. This non-intrusive feature makes the PTS & PTS-M a more desirable option than intrusive systems from an installation, maintenance and corrosion prevention standpoint. EASY MOUNTING The systems can be permanent or temporary and can be accomplished by using pipe straps or clamps. Units can be installed along the above ground line as often as is needed. SAFETY It also offers safer monitoring. The systems are provided in explosion-proof Class I, Division 1, Groups B, C, & D certified enclosures. The enclosures come complete with an O ring seal, which makes the housing NEMA 4X/7. When supplied by the factory as a complete system, proper explosion proof fittings are used and manufacturer specified procedures are followed to connect the units in order to maintain their rating. MODULAR DESIGN The system was designed as a modular system and each section of the system can be sold separately allowing the user the flexibility of only buying and incorporating what is needed. Three quarter inch hubs are provided on each enclosure for conduit connection into your SCADA or recording system. Indicator Module* Sensor Module* Power Module* Passage Indicator Window Reset Button * Explosion-proof Class I, Division 1, Groups B, C, & D certified enclosures.

spy Acoustic pig tracker Spyphone The allows you to listen to any internal pipeline travelers in motion. It is not a geopphone. The pick-up sensors cover a wide range of frequencies from 1Hz 20KHz. The also allows the user to set and restrict multiple frequency ranges. The versatile pick-up sensor, which comes with a 3 contact spike, can also be magnetically attached directly to exposed valves or pipes. You may also securely attach the sensor to a steel probe. The 12-volt auto adapter allows you to listen from the comfort of your vehicle. Plug in the full-spectrum FM transmitter and you can listen for pipeline travelers through your sound system. AUTO-KIT STANDARD ACCESSORIES 20 Sensor Extension Cord FM Transmitter Auto Power Cord Head Phones Sensor (pick up sensor) Sensor Magnetic Base (2) 9-Volt Batteries (2) 9-Volt Battery Holder 12-Volt Auto Adapter Port Sensor Jack FOR SPYPHONE SENSOR Power Indicator Light Tone Knob ADJUST TONE OF SIGNAL Volume Control Knob Range Knob ADJUST FREQUENCY RANGE Headphone Jack

three ways to use the spyphone using the spyphone sensor with the auto kit Using the Spyphone sensor on above ground pipe or valves Ground 20 Extension Cord Sensor Pig Sensor using the spyphone sensor in the ground Sensor Magnetic Base Pig Ground Ground Sensor Pig Specifications FREQUENCY 1 Hz 20 KHz (Acoustic) BATTERY 9V Battery or 12V Auto Adapter SIGNAL INDICATOR Audible WEIGHT 1.5 lbs DIMENSIONS L x W x H 8.5 x 5.5 x 2 FACTORY WARRANTY 3 Month DOMESTIC / INTERNATIONAL STANDARDS CE Compliant

Specifications TRANSMITTERS PT101 PT107 Minimum Size 2 4 [50.8mm 101.6mm] 2 8 [50.8mm 203.2 mm] Transmitter Length 4.1875 [106.4mm] 6.3125 [160.33mm] Transmitter Diameter 1 [25.4mm] 1.25 [31.75 mm] Maximum Hours of Signal 60 Hours 60 Hours Batteries Required 1 Lithium 3V 1 Lithium 3V Maximum Pickup Range (free air) 15 20 [4.72M 6.096M] 20 25 [6.1M 7.62M] Ground Cover Depth Pickup Range 4 [1.23M 1.83M] 6 8 [1.83M 2.44 M] Maximum Operation Pressure 1000 PSI [69 Bar] 1000 PSI [69 Bar] Temperature Range -20 o F 180 o F [-29 o C 82 o C] -20 o F 180 o F [-29 o C 82 o C] *Minimum Bend 2 5D* 3 4 3D* 2 5D* 3 8 3D* (Medium High Density Polly Pig) TRANSMITTERS PT275 PT750 Minimum Size 6 [152.4mm] and Up 12 [304.8mm] and Up Transmitter Length 7.5 [190.5mm] 13.875 [352.4mm] Transmitter Diameter 3 [76.2mm] 3.5625 [90.5mm] Maximum Hours of Signal 200 Hours 500 Hours Batteries Required 4 AA Batteries 8 C Alkaline Maximum Pickup Range (free air) 60 75 [18.29M 22.86M] 100 [30.5M] Ground Cover Depth Pickup Range 15 [4.6M] 25 30 [7.6M 9.1M] Maximum Operation Pressure 2000 PSI [138 Bar] 3000 PSI [207 Bar] Temperature Range -20 o F 180 o F [-29 o C 82 o C] -20 o F 180 o F [-29 o C 82 o C] *Minimum Bend 3D* 3D* (Medium High Density Polly Pig) * When calculating pipe bends please reference the pig manufacturer. Additionally, when using steel mandrel pigs, the minimum pipe bend is determined by what the actual steel mandrel pig can negotiate. ptr FREQUENCY BATTERY BATTERY LIFE DISPLAY SIGNAL INDICATOR WEIGHT (LB) DIMENSIONS L x W x H FACTORY WARRANTY DOM. / INTL. STANDARDS 23 Hz Receive 2 x 9 Volt 50 Hrs LCD Audible / Visual 1.5 7.5 x 5.25 x 2.5 12 Month CE Compliant pts /pts-m ENCLOSURE POWER INPUT POWER OUTPUT TRANSMIT SPEED DISPLAY WEIGHT (LB) DIMENSIONS L x W x H FACTORY WARRANTY DOM. / INTL. STANDARDS Enclosure Class 1, Division 1, Groups B, C & D Blind modules Either 129 Volts AC or ±3VDC (Sensor Module) and 18 Volts DC for Indicator ** Normal Open non-latching Dry Contacts rated at 1A at 250 Volts AC PTS Passage Indicator NOT a Presence Indicator PTS-M 1 fps. Minimum of One Gauss Outside of the Visual 9.4 26 x 26 x 4.75 3 Month CE Compliant ** Other types of power supply inputs can be used, but must be specified on order entry to allow for modifications to be made to the modules.