USER'S MANUAL DMR-4350

Similar documents
USER'S MANUAL DMR-4300

USER'S MANUAL DMR-2400

USER S MANUAL DMR-1500

USER'S MANUAL DMR-6700

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Autoranging Multimeter Extech EX503

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

User s Guide. 400A AC/DC Clamp Meter. Model MA220

R/C SMD Tweezers Multimeter Model RC200

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

200Amp AC Clamp Meter + NCV Model MA250

Compact MultiMeters + Voltage Detector

EM420A/420B DIGITAL MULTIMETER OWNERS MANUAL Read this owners manual thoroughly before use

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

400Amp True RMS AC Clamp Meter + NCV

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

OPERATING INSTRUCTION

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

User Guide. Digital AC/DC Clamp Meter Model 38394

User s Guide. Digital AC/DC Clamp Meter Model 38394

DM-45 Digital Multimeter

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

400Amp True RMS AC/DC Clamp Meter Model EX613

AMM-1022 Digital Multimeter USER`S MANUAL

AC/DC CLAMP METER USER S MANUAL

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

600A Clamp Meters w/tightsight Display

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

AUTORANGING TRUE RMS MULTIMETER USER GUIDE. INST151 Doc 1.00

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

DDM350 Pen-Type Digital Multimeter User s Manual

Not for Reproduction

Dawson DDM190. Digital Multimeter User s Manual

DIGITAL MULTIMETER INSTRUCTION MANUAL

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

DMM8900 SERIES USERS MANUAL

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Pen-type DIGITAL MULTITESTER

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

OPERATOR S INSTRUCTION MANUAL

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

312, 316, 318. Clamp Meter. Users Manual

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Digital Multimeter, Pen Type

NOTE: Fully read and understand this manual before using this Digital Multimeter.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

MS2109A AC/DC Clamp Meter. User Manual. Contents

User Manual. All rights reserved. Specifications are subject to change without notice.

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Pen Multimeter. Model

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DIGITAL CLAMP METER Use s Manual

CONTENTS MS2033A. 1.Introduction Safety Information...01

PeakTech 3355 / 3360

DCM730. Digital Clamp Meter User s Manual

MS2030 CAT III 600 V A V AUTO RS232

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

User Manual Digital Multimeter. model no.: MSR-U1000

ProfiScale MULTI Multimeter

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

AX-C Introduction. 2. Safety Information

M-1000D DIGITAL MULTIMETER

Digital Clamp Meter (TRMS) Model : 2727

User Manual. All rights reserved. Specifications are subject to change without notice.

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

MS8223A. CAT.IIi 600 V

MW3105 DIGITAL CLAMP MULTIMETER

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

User Manual Digital Clamp Multimeter. model no.: MSR-C600

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

User Manual Digital Multimeter

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

DIGITAL MULTIMETER with Non-Contact Detection

User s Guide. Model MA A AC Mini Clamp-on Meter

Model DIGITAL MULTIMETER

Pen Multimeter. Model

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

DVM1190 DIGITAL MULTIMETER

Electrical Multimeter

Electrical Multimeter

Digital Clamp Meter. User Manual

Transcription:

USER'S MANUAL DIGITAL MULTIMETER DMR-4350 CIRCUIT-TEST ELECTRONICS www.circuittest.com

TABLE OF CONTENTS SAFETY Safety Information...................................... 2 Safety Symbols........................................ 3 INTRODUCTION LCD Symbol Definitions................................. 4 Front Panel Description.................................. 5 SPECIFICATIONS General.............................................. 6 Ranges and Accuracy................................... 7 OPERATING INSTRUCTIONS Understanding True RMS................................ 8 Auto Power Off Feature.................................. 8 Analog Bargraph Display................................. 8 1. DC Voltage Measurement............................. 9 2. AC Voltage Measurement.......................... 9-10 3. DC Current Measurement..........................10-11 a) less than 326 DC current b) 326 or more DC current 4. AC Current Measurement..........................11-13 a) less than 326 DC current b) 326 or more AC current 5. Resistance Measurement............................ 13 6. Continuity Test..................................... 14 7. Diode Test..................................... 14-15 8. Temperature Measurement........................... 15 9. Range Function.................................... 16 10. Hold Function..................................... 16 11. Battery Replacement................................ 17 12. Fuse Replacement.............................. 17-18 MAINTENANCE........................................... 19 ACCESSORIES........................................... 19 WARRANTY.............................................. 19 1

SAFETY INFORMATION This meter is CUL and UL approved and conforms to IEC 61010-1 for Category III - 600V and Category II - 1000V. This meter is designed to be safe under the following conditions: indoor use, altitude up to 2000m, temperature 5 C to 40 C, maximum relative humidity 80% for temperatures up to 31 C decreasing linearly to 50% relative humidity at 40 C and rated pollution degree 2. Caution and proper guidelines must be followed for personal and product safety. Read this instruction manual carefully and completely before using the meter. Lack of caution or poor safety practices can result in serious injury or death. This meter is not recommended for high voltage industrial use; for example, do not use for measurement on 440VAC or 600VAC industrial power mains. The unit is intended for use with low energy circuits up to 600VDC / 600VAC or high energy circuits up to 250VAC / 250VDC only. Use caution when working above 60VDC or 30VAC RMS as these voltages pose a shock hazard. Always consider circuits to be energized. Never assume any equipment to be de-energized. Always start with power off. Set the function switch to the correct setting before making any measurements and do not change position of the function switch during measurements. Never connect unit to AC or DC powered circuits when the function switch is set to resistance, diode check or continuity ranges. Always disconnect the power when performing resistance, diode or capacitance tests. Discharge capacitor before testing. Disconnect the live/positive test lead (red) prior to disconnecting the common/negative test lead (black). When appears on the display, change both batteries to achieve more accurate readings. Disconnect the test leads before removing the batteries or the fuse. Do not operate the unit unless the case is completely closed. When using the test probes always keep fingers behind the finger guards. Never touch the exposed probe tip. Always inspect the instrument, test leads and other accessories for damage prior to use. Use only UL recognized test leads (included with this meter). 2

SAFETY SYMBOLS Safety symbols and special annunciators on the meter and in this manual indicate cautions and warnings of important operational procedures that must be followed to ensure personal and product safety. This symbol indicates a General Warning. When adjacent to a terminal or operating device indicates that the operator must refer to an explanation in the Operating Instructions. 500V This symbol indicates that the terminal(s) so marked must not be connected to a circuit point at which the voltage with respect to ground MAX exceeds 500V AC/DC. This symbol adjacent to one or more terminals indicates them as being associated with ranges that may in normal use, be subjected to particularly hazardous voltages. For maximum safety, the meter and its test leads should not be handled when these terminals are energized. This meter is protected by double insulation. Service this meter by a professional only. 3

INTRODUCTION DMR-4350 is a True RMS Auto Ranging meter featuring an analog bargraph for easy viewing of measurement changes. This meter can measure/test the following: Voltage Current Resistance Continuity Diode Temperature LCD DISPLAY SYMBOL DEFINITIONS DISPLAY/SYMBOL DEFINITION DISPLAY/SYMBOL DEFINITION Diode A Amps Data Hold Range Hold AC Alternating Current Low Battery Continuity V Volts F Degree Fahrenheit M Mega C Degree Celsius K Kilo µ Micro Ohms m milli OL Over Range Analog Bargraph 4

AUTO OFF FUSED MAX for 15 sec MAX every 30 min FUSED 320 MAX 500V MAX / 1000 VDC 750 VAC CAT III 600V CAT II 1000V 1 7 2 8 3 4 CIRCUIT-TEST DMR-4350 9 10 5 6! TRUE RMS! V// /! 11 12 / FRONT PANEL DESCRIPTION NO. ITEM DESCRIPTION 1 LCD Display 3-3/4 digit 3200 count LCD Display 2 Button Indicated by on the LCD display. Overrides the Auto Ranging feature. Starts with displaying the lowest range in manual mode. This function works for AC/DC Volts, AC/DC Current and Ohms mode. 3 Power Button Power ON/OFF push button switch 4 Temperature Jack Plug in 'K' type thermocouple observing the polarity 5 Jack Positive input jack to plug in red test lead for measurement only. 6 / Jack Positive input jack to plug in red test lead for current measurement up to 326 7 / Button When the function switch is turned to /, use this pushbutton to select between continuity and diode tests 8 Button The displayed data will freeze and will appear on the LCD. Changes in the input signal will not change the display. 9 FUNCTION Switch Function Switch to select measurement mode 10 Test Lead Input Indicating LEDs Lighted LED indicates the correct jack to plug in the test lead for the selected function. LED will turn off after the test lead is fully inserted. If the test lead is incorrectly plugged in, the LED will start blinking and buzzer will sound. 11 V/ / / Jack Positive input jack to plug in red test lead for voltage, resistor, diode and continuity check. 12 Jack Plug in black test lead in all measurement modes, common ground 5

SPECIFICATIONS GENERAL Display: 3 3 / 4 digit 3200 count LCD Maximum Display: 3200 Ranging: Auto/Manual Auto Shut-off: Meter will shut-off after 10 minutes from last use Polarity: Automatic, minus (-) sign indicates negative polarity, no sign for positive polarity Measuring rate: 3 times/sec Input impedance: 10M ( / ) Diode Test: Test current of 1.0 maximum Continuity: Audible signal sounds if resistance is less than 20 Over range indication: ʻOLʼ is displayed Operating Temp: 5 to 40 C (41 to 104 F) Storage Temp: -10 to 50 C (14 to 122 F) Relative Humidity: <75% Operating/Storage Power Source: 2 x AAA 1.5V Battery Fuse: 0.5A/250V (5x20mm Fast Acting), 16A/500V (6.3x32mm Fast Acting Ceramic) Temperature Probe: 'K' Type Thermocouple rated at 0 to 260 C (-32 to 500 F) [model no. TL-190] Dimensions: 185(H) x 90(W) x 45(D) mm (7 5 / 16 x 3 1 / 2 x 1 13 / 16") Weight: 347g (12.25 oz) Accessories included: One pair of test leads, ʻKʼ type thermocouple, Screw-on Alligator Clips, 2 x AAA batteries, Userʼs manual 6

S AND ACCURACY FUNCTION RESOLUTION ACCURACY DC VOLTAGE (DC V) AC VOLTAGE (AC V) DC CURRENT (DC A) AC CURRENT (AC A) (40-400HZ) 326mV 3.26V 32.6V 326V 1000V 3.26V 32.6V 326V 750V 326 3.26 32.6 326 326 3.26 32.6 326 RESISTANCE 326 3.26k 32.6k 326k 3.26M 32.6M 0.1mV 1mV 10mV 100mV 1V 1mV 10mV 100mV 1V 100nA 1 10 100 10 100nA 1 10 100 10 0.1 1 10 100 1k 10k ±(0.5% reading + 5 digits) ±(0.8% reading + 8 digits) ±(1.2% reading + 5 digits) ±(2% reading +8 digits) ±(1.5% reading + 5 digits) ±(3% reading + 5 digits) ±(0.8% reading + 5 digits) ±(3% reading + 10 digits) C -23 to 1000 C 1 C ±(1% reading + 6 digits) F -10 to 1830 F 1 F ±(1% reading + 8 digits) NOTE: Accuracy consists of: (% reading i.e. accuracy of the measurement circuit + digits i.e. accuracy of the analog to digital converter) Reference conditions: 23 C ± 2 C, 40-60% Relative Humidity 7

OPERATING INSTRUCTIONS This meter comes with an exclusive patented technology featuring bright LEDs indicating the correct input jack to plug-in the positive (red) test lead for the selected function. The LED turns off after the test lead is completely plugged in the correct jack. If the test lead is plugged in the wrong jack, the LED will start flashing and the buzzer will start beeping. AUTO OFF FEATURE This meter turns off automatically if more than 10 minutes elapses between uses. The meter will give an audible sound before turning off. To turn the meter back ON once it powers off, press the button twice, or press the button or button once. ANALOG BARGRAPH DISPLAY Besides the digital readout, this meter also indicates all the measurements on the bargraph at the bottom of the display. The bargraphʼs length increases and decreases with the measured value making it easy to view the changes in the measurement immediately. UNDERSTANDING AC ZERO INPUT BEHAVIOR OF TRUE RMS When measuring the AC voltage and current, the meter is calculating the input and converting them to the data that the LCD can display. The converter needs a certain level of the input voltage to make the measurement. This level is 5% of the ranges for this meter. So the non-zero digits that are displayed on the meter when the test leads are open or shorted are normal. They do not affect the specified AC accuracy above 5% of the ranges. 8

/ 1. DC VOLTAGE MEASUREMENT WARNING: MAXIMUM INPUT IS 1000V DC. USE EXTREME CAUTION WHEN WORKING WITH HIGH VOLTAGES. NEVER APPLY THE TEST LEAD TO THE MEASURING CIRCUIT WHEN CHANGING THE POSITION OF THE FUNCTION SWITCH. NOTE: The meter will be Auto ranging for this function. If you wish to measure with Manual range, follow instructions described in Section 9. For manual ranging, start at the highest range and work down. Set the function switch to DC V. ʻmVʼ appears on the display and the LED next to V/ / / jack turns on. Plug the red test lead in V/ / / jack and CIRCUIT-TEST DMR-4350 black test lead in jack. + DC Apply the test leads to the circuit to be measured. Ensure that the black lead is connected to the negative side of the circuit and red lead to the positive. V// / Read the displayed voltage. / If the minus (-) sign appears it means the voltage is negative at the point being measured. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. The input voltage should not exceed the measurement capability of this meter. 2. AC VOLTAGE MEASUREMENT WARNING: MAXIMUM INPUT IS 750V AC. USE EXTREME CAUTION WHEN WORKING WITH HIGH VOLTAGES. NEVER APPLY TEST LEADS TO THE MEASURING CIRCUIT WHEN CHANGING THE POSITION OF THE FUNCTION SWITCH. NOTE: The meter will be Auto ranging for this function. If you wish to measure with Manual range, follow instructions described in Section 9. For manual ranging, start at the highest range and work down. Set the function switch to AC V. 9

/ / ʻACʼ and ʻVʼ appear on the display and the LED next to V/ / / jack turns on. Plug the red test lead in V/ / / jack and black test lead in jack. Apply the test leads to the circuit to be measured. Read the displayed TRMS voltage. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. The input voltage should not exceed the measurement capability of this meter. CIRCUIT-TEST DMR-4350 V// / / 3. DC CURRENT MEASUREMENT WARNING: WHEN MEASURING CURRENT REMOVE ALL FROM THE CIRCUIT BEING TESTED. NEVER APPLY THE TEST LEAD TO THE MEASURING CIRCUIT WHEN CHANG- ING THE POSITION OF THE FUNCTION SWITCH. NOTE: The meter will be Auto ranging for this function. If you wish to measure with Manual range, follow instructions described in Section 9. For manual ranging, start at the highest range and work down. a) Less than 326 DC Current Measurement Set the function switch to. ʻʼ appears on the display and the LED next to / jack turns on. Plug the red test lead in / + DC jack and black test lead in the jack. Remove power from the circuit that is to be measured. Open up the circuit and connect the black lead to the negative side and the red lead to the positive side of the circuit so that the test leads are in series with the load to be measured. CIRCUIT-TEST DMR-4350 V// / / 10

/ Apply power to the circuit. Read the displayed current. If the numeral value in the display is too small, change the function switch from to for a more sensitive measurement range. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. b) 326 or more DC Current Measurement CAUTION! Do not exceed 15 seconds when measuring the range and wait for 30 minutes between each measurement. Set the function switch to. ʻAʼ appears on the display and the LED above jack turns on. Plug the red test lead in jack and black test lead in the jack. Remove power from the circuit that is to be measured. Open up the circuit and connect the black lead to the negative side and the red lead to the positive side of the circuit so that the test leads are in series with the load to be measured. Apply power to the circuit. Read the displayed current. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. + DC CIRCUIT-TEST / DMR-4350 V// / 4. AC CURRENT MEASUREMENT WARNING: WHEN MEASURING CURRENT REMOVE ALL FROM THE CIRCUIT BEING TESTED. NEVER APPLY THE TEST LEAD TO THE MEASURING CIRCUIT WHEN CHANG- ING THE POSITION OF THE FUNCTION SWITCH. NOTE: The meter will be Auto ranging for this function. If you wish to measure with Manual range, follow instructions described in Section 9. For manual ranging, start at the highest range and work down. 11

/ / a) Less than 326 AC Current Measurement Set the function switch to. ʻACʼ and ʻʼ appear on the display and the LED next to / jack turns on. Plug the red test lead in / jack and black test lead in the jack. Remove power from the circuit that is to be measured. Open up the circuit and connect the black lead to the negative side and the red lead to the positive side of the circuit so that the test leads are in series with the load to be measured. Apply power to the circuit. Read the displayed current. CIRCUIT-TEST If the numeral value in the display is too small, change the function switch from to for a more sensitive measurement range. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. / DMR-4350 V// / b) 326 or more AC Current Measurement CAUTION! Do not exceed 15 seconds when measuring the range and wait for 30 minutes between each measurement. Set the function switch to. ʻACʼ and ʻAʼ appear on the display and the LED above jack turns on. Plug the red test lead in jack and black test lead in the jack. Remove power from the circuit that is to be measured. Open up the circuit and connect the black lead to CIRCUIT-TEST DMR-4350 V// / / 12

/ the negative side and the red lead to the positive side of the circuit so that the test leads are in series with the load to be measured. Apply power to the circuit. Read the displayed current. If ʻOLʼ appears on the display, it indicates over-range. Immediately remove test leads from the measuring circuit to avoid any damage to the meter. 5. RESISTANCE MEASUREMENT WARNING: NEVER CONNECT THE TEST LEAD TO ANY VOLTAGE WHEN THE FUNC- TION SWITCH IS SET TO. REMOVE ALL FROM THE CIRCUIT BEING TESTED WHEN CHECKING RESISTANCE. DISCHARGE ANY CHARGED CAPACITORS. NEVER APPLY THE TEST LEAD TO THE MEASURING CIRCUIT WHEN CHANGING THE POSITION OF THE FUNCTION SWITCH. NOTE: The meter will be Auto ranging for this function. If you wish to measure with Manual range, follow instructions described in Section 9. For manual ranging, start at the highest range and work down. Set the function switch to. ʻM ʼ appears on the display and the LED next to V/ / / jack turns on. Plug the red test lead in V/ / / jack and black test lead in jack. Apply the test leads to the resistor being measured. If the resistor is part of a circuit, it is necessary to disconnect one end of the resistor to avoid any unwanted interference from the rest of the circuit. Read the displayed resistance indicated with proper decimal point and one of the symbols, K or M. RESISTOR CIRCUIT-TEST / DMR-4350 V// / 13

/ / 6. CONTINUITY TEST WARNING: NEVER CONNECT THE TEST LEADS TO ANY VOLTAGE WHEN THE FUNC- TION SWITCH IS SET TO /. REMOVE ALL FROM THE CIRCUIT BEING TESTED WHEN CHECKING RESISTANCE. DISCHARGE ANY CHARGED CAPACITORS. Set the function switch to /. and appear on the display and the LED next to V/ / / jack turns on. Plug the red test lead into the V/ / / jack and the black test lead into the jack. Apply the test leads to the circuit. The buzzer will sound if the resistance is less than 20 and the measured resistance value will be displayed in ohms with proper decimal point. WIRE CIRCUIT-TEST / DMR-4350 V// / 7. DIODE TEST WARNING: NEVER CONNECT THE TEST LEAD TO ANY VOLTAGE WHEN THE FUNCTION SWITCH IS SET TO /. REMOVE ALL FROM THE CIRCUIT BEING TESTED WHEN PERFORMING THE DIODE TEST. DISCHARGE ANY CHARGED CAPACITORS. Note: If the diode is part of a circuit, it is necessary to disconnect one end of the diode to avoid any unwanted interference from the rest of the circuit. The value indicated in the display during the diode check is the forward bias voltage. Set the function switch to /. and appear on the display and the LED next to V/ / / jack turns on. Press / pushbutton once and and ʻVʼ will appear on the display. Plug the red test lead into the V/ / / jack and the black test lead into the jack. CIRCUIT-TEST DMR-4350 V// / / 14

/ / Apply the test leads across the diode terminals and note the meter reading. Reverse the diode and note this reading. Based on the readings the result can be evaluated as follows: If one reading is around 0.5 and the other reading is ʻOLʼ, the diode is good If both readings are ʻOLʼ, the diode is open (defective) If both readings are very small or 0 (zero), the diode is shorted (defective) CIRCUIT-TEST DMR-4350 V// / / 8. ERATURE MEASUREMENT WARNING: REMOVE ALL VOLTAGE SOURCES FROM THE CIRCUIT TO BE TESTED BEFORE TAKING A ERATURE MEASUREMENT. DO NOT MEASURE ERATURES OF METAL PARTS WITH A VOLTAGE ON THEM. Set the function switch to C or F depending on whether the temperature is to be measured in degrees Celsius or degrees Fahrenheit. Plug the ʻKʼ type thermocouple in the CIRCUIT-TEST DMR-4350 jack. NOTE: The K type thermocouple supplied with this meter is rated at 0 to 260 C (-32 to 500 F), although the meter is capable of measuring up to 1000 C (1830 F). Touch the probe tip to the component you are testing and keep it there for about 30 seconds or until the reading stabilizes. The digital reading will display the value in proper decimal point & value. / V// / 15

/ 9. FUNCTION You can manually select the desired range in five functions: Set the function switch to,, or. Plug the test leads into their appropriate jacks. Press the Range button once to deactivate AUTO mode. Each additional push causes the range to go higher. When the highest range is reached, the next push returns the range to its lowest point. To cancel manual ranging and return to auto ranging, press and hold the Range button until disappears from the display. CIRCUIT-TEST DMR-4350 V// / / 10. FUNCTION Use this function to hold a reading. When this pushbutton is pressed, the data being displayed at the time will be ʻfrozenʼ in the display and will appear in the display. Changes in the input signals will not affect the display. This function can be used in all measurement modes. Press the pushbutton again to release the function and will disappear. 16

11. BATTERY REPLACEMENT WARNING: DISCONNECT BOTH TEST LEADS FROM ANY SOURCE OF VOLTAGE BE- FORE REMOVING THE BACK COVER. DO NOT OPERATE THE METER UNTIL THE BACK COVER IS IN PLACE AND FASTENED SECURELY. will appear in the display when the battery drops below the operating voltage and requires replacing. Turn off the meter and disconnect both test leads. Remove the single screw securing the battery/fuse cover and lift to open. Replace both AAA batteries observing the correct polarity. Replace the cover and tighten the screw. 12. FUSE REPLACEMENT WARNING: DISCONNECT BOTH TEST LEADS FROM ANY SOURCE OF VOLTAGE BEFORE REMOVING THE BACK COVER. DO NOT OPERATE THE METER UNTIL THE BACK COVER IS IN PLACE AND FASTENED SECURELY. a) 0.5 Amp Fast acting 5x20mm Fuse Turn off the meter and disconnect both test leads. Remove the single screw securing the battery/fuse cover and lift to open. Remove the batteries. Gently pull the fuse from its holder by pulling gently on the ribbon. Replace the blown fuse with a CSA/UL listed fast acting fuse rated at 0.5A/250V only (with the same ribbon ring around the fuse). Do not use a fuse which has a higher rated value than specified or try to bypass the fuse. Replace the batteries and cover and tighten the screw. 17

b) 16 Amp Fast acting 6.3x32mm Ceramic Fuse (by a professional person only) Turn off the meter and disconnect both test leads. Remove the three screws at the back of the case (one at the top and two at the bottom). Remove the single screw securing the battery/fuse cover and lift to open. Remove the batteries. Carefully lift the top of the case away from the bottom. CAUTION: Lift the top case carefully - do not break the wires attached to the battery compartment. Gently lift the battery compartment and move it through the hole on the inner side of the meter. The 16 amp fuse is the larger fuse on the bottom of the PC board, which should now be in full view. Carefully remove the old fuse and replace it with a new CSA/UL listed fast acting ceramic 16A/500V fuse only. 18

MAINTENANCE a) Always keep the meter dry. b) Keep the meter clean. Wipe the case occasionally with a damp cloth. Do not use chemicals, cleaning solvents or detergents. c) Use and store the meter in recommended normal environmental conditions. Extreme temperatures can shorten the life of the electronic components. d) Use only fresh batteries. e) Remove the batteries when the meter is not being used for a long period of time. ACCESSORIES Test Leads (TL-108) ʻKʼ Type Thermocouple (TL-190) Screw-on Alligator Clips (TL-210) Fuses: 5x20mm Fast 0.5A/250V, 6.3x32mm Fast Ceramic 16A/500V Batteries: 2 x AAA LIMITED WARRANTY Circuit-Test Electronics warrants to the original purchaser that this product be free of defect in material or workmanship for a period of 2 years from the date of purchase. Visit our website (www.circuittest.com) for information on warranty service. Any product which has been subjected to misuse or accidental damage is excluded from the warranty. Except as stated above, Circuit-Test Electronics makes no promises or warranties either expressed or implied including warranties of merchantability or the fitness for any particular purpose. Register your product online at www.circuittest.com CIRCUIT-TEST E L E C T R O N I C S A division of R.P. Electronic Components Ltd. www.circuittest.com 19