SL-RAT Acoustic Inspection Sewer Line Assessment Report

Similar documents
ALERT2 TDMA Manager. User s Reference. VERSION 4.0 November =AT Maintenance Report Understanding ALERT2 TDMA Terminology

Contrail TDMA Manager User s Reference

Yield Monitoring Systems: Understanding how we Estimate Yield

ZONESCAN net Version 1.4.0

Determine if the function is even, odd, or neither. 1) f(x) = 8x4 + 7x + 5 A) Even B) Odd C) Neither

Test Protocol for the Rolling Density Meter

ZONESCAN net Version 1.4.1

Nebraska 4-H Robotics and GPS/GIS and SPIRIT Robotics Projects

CC.2.1.HSF2a: Convert between fractions and decimals in a real-world problem

Revision Date: 6/6/2013. Quick Start Guide

INSTALLATION, OPERATION MANUAL

Riser Lifecycle Monitoring System for Integrity Management

What is a Lane? serial link lane parallel link

Products. Locating DAMAGE PREVENTION

UNIQUE KIOSK SITE INSPECTION FORM

How to do Geo-fencing with the FM200

How to provide as constructed information and interpretation of sewer plans

BSc (Hons) Computer Science with Network Security, BEng (Hons) Electronic Engineering. Cohorts: BCNS/17A/FT & BEE/16B/FT

Identify if each number is rational or irrational. Click "A" for rational. "B" for irrational

ArcGIS Tutorial: Geocoding Addresses

Xuegang (Jeff) Ban, Xia Yang, Jeff Wojtowicz, Jose Holguin-Veras Rensselaer Polytechnic Institute

Smart GPS Sync. Manual. Smart GPS Sync. Manual

We will study all three methods, but first let's review a few basic points about units of measurement.

Document # Rev. C October, GEMINI EXPRESS MULTIPLEXER User s Guide

LD2342 USWM V1.6. LD2342 V1.4 Page 1 of 18

Geodesy, Geographic Datums & Coordinate Systems

Model OT-1000-HH 1GHz SuperMod Optical Transmitter, DWDM ADVANCED OPERATING MANUAL

1090i. uavionix Ping1090i Transceiver QUICK START GUIDE

PhysioTel Digital Signal Simulator Manual

Appendix B: Descriptions of Virtual Instruments (vis) Implemented

Luxurious Transporting System

High Point Communications Authorized dealer for USA Fleet Services

Robus 600/1000. Programmable functions using the Oview programmer. STF ROBUS Rev00 Firmware: RF02

2-TONE CODING FORMAT INSTRUCTION MANUAL

Designing Information Devices and Systems I Fall 2016 Babak Ayazifar, Vladimir Stojanovic Homework 11

Modbus communication module for TCX2: AEX-MOD

Generic Bathymetry Data - Interface Control Document

Decoding the 406 MHz beacons Display on 4 lines of the message information

TAP 6 Demo Quick Tour

Know your energy. Modbus Register Map EM etactica Power Meter

RTK Base Station Configuration and Utilities. Table of Contents

RECOMMENDATION ITU-R M *

SYMEO LOCAL POSITIONING RADAR

Technical Specifications for Broadband Terminal Equipment of Mobile Broadband Business

Aboveground Monitoring - Casings Long Range Electromagnetic Wave (EMW) Inspection

Geocoding: Making your point with maps

Industriefunkuhren. Technical Manual. System 7001RC. Multi-Source Function ENGLISH. Version:

THE CHURCH OF J ESUS CHRIST OF LATTER-DAY SAINTS BISHOPS' STOREHOUSE THE CHURCH OF OF LATTER-DAY SAINTS HOME STORAGE CENTER BISHOPS' STOREHOUSE

PRE-LAB for: Introduction to Aerial Photographs and Topographic maps (Ch. 3)

GPS Errors. Figure 1. Four satellites are required to determine a GPS position.

SRT Marine Technology. LD2342 V1.4 Page 1 of 22

ThunderBolt Display. by Adam Maurer, VK4GHZ

Lecture 8: GIS Data Error & GPS Technology

Anne Arundel County Dept. of Inspections and Permits Water Sewer Plan Checklist

This presentation on satellite communications is designed to provide a broad introduction into this method of radio communications.

Ground / Jumper Assembly Tester Catalog No. 6714

Field Experience with GPS: Verifying GPS Coordinates Using USAPhotoMaps Software

The Real Number System and Pythagorean Theorem Unit 9 Part B

GLOBAL POSITIONING SYSTEMS

MAT106: Wall Framing. AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products

Regulatory Authority of Bermuda report on

SECTION SUBMITTAL PROCEDURES

MN5020HS Smart GPS Antenna Module

I-01 NAVIGATIONAL WARNING RECEIVERS

Head Tracker Range Checking

HOW CAN A GPS HELP? WHY A GPS? HOW DOES A GPS WORK?

How to use the VEMCO Range Test Software. 14 Jan 2015 DOC

Shallow Water Array Performance (SWAP): Array Element Localization and Performance Characterization

Diversity Image Inspector

LIST OF EXPERIMENTS. KCTCET/ /Odd/3rd/ETE/CSE/LM

CONTENTS OF THE BOX. *PIR sensor only **Dual Technology and PIR sensors only. Description PIR Ultrasonic Dual Technology

IDEA Connection 8. User guide. IDEA Connection user guide

1 UAT Test Procedure and Report

TI25 - Pre-Instructional Survey

southpaw enterprises, inc.

Government Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications

VERSATILE USAGE OF ELECTROMAGNETIC ACOUSTIC TECHNOLOGIES FOR IN-LINE INSPECTION OF AGEING PIPELINES

Brian Hanna Meteor IP 2007 Microcontroller

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 29, 2012

Excavating, Backfilling, and Compaction for Utilities Piping (Plumbing).

Geophysical Survey Rock Hill Bleachery TBA Site Rock Hill, South Carolina EP-W EPA, START 3, Region 4 TABLE OF CONTENTS Section Page Signature

KNOW YOUR LIMITATIONS. A Guide to Analyzing Televised Inspection NATIONAL CLAY PIPE INSTITUTE NCPI NATIONAL CLAY PIPE INSTITUTE QUALITY.

Configuring the Global Navigation Satellite System

Chemistry Instrumental Analysis Lecture 10. Chem 4631

Dynatel. 2273M Cable/Pipe and Fault Locators 2273M-iD Cable/Pipe/Fault and Marker Locators with id Read/Write

FOUNDATION Fieldbus: the Diagnostics Difference Fieldbus Foundation

1.0 Introduction. Related Products and Documentation

The BOW GNSS Receiver Project

ANTARES Project: Visibility Analysis

Global Positioning Systems (GPS) Trails: the achilles heel of mapping from the air / satellites

LPU-2127 User Manual

Error Detection and Correction

Paradigm. Connect100 Installation Guide

HTTF Transit Time Ultrasonic Flow Meter

Essentials of Navigation

RECENT DEVELOPMENTS IN EMERGENCY VEHICLE TRAFFIC SIGNAL PREEMPTION AND COLLISION AVOIDANCE TECHNOLOGIES. Purdue Road School 2017 Dave Gross

Recent Progress in the Development of On-Board Electronics for Micro Air Vehicles

Piping & Equipment Identification

New Directions in Buried UXO Location and Classification

UNPLATTED SUBDIVISION APPLICATION PACKAGE SUBMITTAL REQUIREMENTS

Transcription:

SL-RAT Acoustic Inspection Sewer Line Assessment Report 12/17/2011 Sewer line assessment results conducted on December 16, 2011 for the Glenwater Dr. Basin. Results in this report are illustrative of the SL-DOG Sewer Line Assessment Report based on an acoustic measurement campaign conducted using the SL-RAT. Questions concerning the report should be directed to Tech Support techsupport@infosenseinc.com.

Table I: Sewer Line Assessment Results Glenwater Dr. Basin SL-RAT Measurements Conducted from December 16, 2011 to December 16, 2011 HW HW Date & Time Duration (sec) Pipe Length (ft) Eval. Pipe Length (ft) Status Assessment (0-Blocked; 10-Clean) Latitude Longitude Latitude Longitude 31 3 6 15 7 12/16/11 3:12 PM 30 3 6 15 7 12/16/11 3:01 PM 29 3 6 15 7 12/16/11 2:51 PM 28 3 6 15 7 12/16/11 2:41 PM 27 3 6 15 7 12/16/11 2:33 PM 26 3 6 15 7 12/16/11 2:25 PM 25 3 6 15 7 12/16/11 2:14 PM 24 3 6 15 7 12/16/11 2:04 PM 23 3 6 15 7 12/16/11 1:58 PM 22 3 6 15 7 12/16/11 1:49 PM 79 150 184 Valid 5 35.31480-80.74676 35.31506-80.74623 79 350 333 Valid 7 35.31557-80.74715 35.31506-80.74623 96 150 60 Valid 4 35.31533-80.74724 35.31549-80.74729 80 250 242 Valid 9 35.31533-80.74724 35.31480-80.74676 192 250 209 Valid 0 35.31488-80.74745 35.31480-80.74676 80 150 115 Valid 9 35.31488-80.74745 35.31517-80.74758 79 250 232 Valid 8 35.31559-80.74816 35.31517-80.74758 160 150 107 Valid 2 35.31559-80.74816 35.31582-80.74794 79 50 83 Valid 6 35.31559-80.74816 35.31581-80.74823 79 250 223 Valid 9 35.31633-80.74863 35.31581-80.74823 Page 2 of 5

Definition for Table 1 columns: SL-RAT transmitting unit. SL-RAT receiving unit. - (Measurement ) Unique identification number for each SL-RAT receiving unit (). (Receiver Operator ) Operator assigned to the operator by the SL-DOG system administrator and entered by the operator when login into the SL-RAT receiving unit (). HW (Receiver Hardware ) Unique serial number assigned by InfoSense to the SL-RAT receiving unit (); serial numbers are even. - (Transmitter Operator ) Operator assigned to the operator by the SL-DOG system administrator and entered by the operator when login into the SL-RAT transmitting unit (). HW - (Transmitter Hardware ) Unique serial number assigned by InfoSense to the SL-RAT transmit unit (); serial numbers are odd. Date & Time Date and time of the SL-RAT measurement. Time is based on SL-RAT local time setting. Duration (Measurement Duration) Duration of the measurement as recorded by the SL-RAT receiver (). Measurement duration is in seconds. Pipe Length (Operator Pipe Length) Pipe length as entered by the SL-RAT receiver operator. This value is used in the pipe segment assessment. Pipe length is in feet. Eval. Pipe Length (Evaluated Pipe Length) Pipe length estimated by the SL-RAT unit. Status (Measurement Status) the SL-RAT receiving unit () evaluates the conditions under which the pipe assessment is conducted and provides a warning concerning possible limitations in the measurement as follows: Measurement Status Valid Early Late No Close Noise Condition No anomalies in the measurement conditions were detected The SL-RAT transmitter unit () was stopped prior to the SL-RAT receiving unit () completed its processing. The Pipe assessment maybe corrupted. The SL-RAT transmitter unit () was started after the SL-RAT receiving unit (). The Pipe assessment maybe corrupted. The SL-RAT transmitter unit () was not turned on during SL-RAT receiving unit () measurement. The Pipe assessment is corrupted. The SL-RAT transmitter unit () and the SL-RAT receiving unit () were too close during the measurement. The Pipe assessment maybe corrupted. The SL-RAT receiver () detected noise conditions which may impact the measurement. The Pipe assessment maybe corrupted. Page 3 of 5

Assessment Pipe assessment scaled from 0 to 10 with the following general interpretation: Assessment Typical Condition / Interpretation 10 No significant obstructions within the pipe 7-9 Minor impediments within the pipe such as joint offsets, partial sags, protruding laterals, debris, minor grease, and/or minor root fibers. 4-6 Impediments within the pipe such as joint offsets, partial sags, protruding laterals, debris, grease, and/or root fibers. Single or multiple occurrences. 1-3 Significant impediments within the pipe such as multiple joint offsets, near full pipe sag, multiple protruding laterals, significant debris, significant grease, significant root fibers and/or root balls. Single or multiple occurrences. 0 Full pipe sag; single or multiple obstructions within the pipe reaching or nearly reaching the flow. Latitude Global position system (GPS) latitude at the SL-RAT receiver () unit at the time of the measurement; GPS measurement is in decimal degrees. Longitude - Global position system (GPS) longitude at the SL-RAT receiver () unit at the time of the measurement; GPS measurement is in decimal degrees. Latitude - Global position system (GPS) latitude at the SL-RAT transmitter () unit at the time of the measurement; GPS measurement is in decimal degrees. Longitude - Global position system (GPS) longitude at the SL-RAT transmitter () unit at the time of the measurement; GPS measurement is in decimal degrees. Page 4 of 5

Legend: SL-RAT In Field Pipe Assessment 0: 1-3: 4-6: 7-10: Figure 2: Glenwater Dr. Basin sewer line assessment classification results overlaid on GIS map. SL-RAT acoustic inspection measurements conducted from December 16, 2011 to December 16, 2011. Sewer line segment classification (i.e., color code) is based on the SL-RAT measurements and is based on the default classification scheme as defined in the legend. Page 5 of 5