M E E T I N S T R U M E N T A T I E MAS ma Soil Moisture Sensor. User Manual. Version 4

Similar documents
Decagon Devices, Inc.

Decagon Devices, Inc.

5TM. Water Content and Temperature Sensors. Operator s Manual

Decagon Devices, Inc.

10HS. Soil Moisture Sensor. Operator s Manual. Version 1.0

Decagon Devices, Inc.

Dielectric Leaf Wetness Sensor. Operator s Manual

TABLE OF CONTENTS. 1. Introduction Operation System Service Reference Index... 18

Soil Moisture Smart Sensors (S-SMx-M005)

Operator s Manual. Decagon Devices, Inc. Version: March 12, :56:25

TABLE OF CONTENTS. 3.1 Specifications About EC

TABLE OF CONTENTS. 1. Introduction Operation System Service... 14

DS-2 Sonic Anemometer

TABLE OF CONTENTS. 3.1 Specifications About 5TM Theory Volumetric Water Content Temperature...

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

K-FACTOR SCALER B & B

LT3000 ULTRASONIC LEVEL TRANSMITTER

305 Stimulus Isolator. Description

USER S MANUAL PROCESS CONTROL MODULE PCM3

Global Water Instrumentation, Inc.

AT Advanced Wire Tracer. Users Manual

Worldwide Manufacturer of Gas Detection Solutions. Transmitter EC 23. Operation Manual

742A Series Resistance Standards

Programmable K-Factor Scaler B and Programming Software Kit B

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

SAS-543 Biconical Antenna Operation Manual

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

K-Factor Scaler F5140 and Programming Kit F5141 Installation & Operating Instructions

TDS-535 Tuned Dipole Set Operation Manual

Bulk Current Injection Probe Test Procedure

C5000 & C5000NF PULSE INITIATOR. Introduction

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

MINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)

301 & 601 Mic/Line Mixers Operation Manual

41P Portable Calibrator User Manual

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

2-wire level transmitter

Glass Electrode Meter

WaterScout SM100 Soil Moisture Sensor Catalog # 6460

TRANSDUCER IN-LINE AMPLIFIER

Broadband Current Probe Series Operation Manual

American Power Design, Inc.

Current Probe Fixture Instruction Manual

Tilting, Swiveling & Rotating Flat Panel Wall Mount

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

X80 Activator. User's Manual. Version 1.1.

Owner s Manual & Safety Instructions

Advanced Test Equipment Rentals ATEC (2832)

LPU-2127 User Manual

201AP Charge Amplifier User Manual

Global Water Instrumentation, Inc.

Copyright 2014 by Minarik Drives

RIOT DISTORTION USER GUIDE

Model 113 Scintillation Preamplifier Operating and Service Manual

Scotchlok UR2 Connector

Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version -

Owner s Manual & Safety Instructions

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Aquaflex Soil Moisture Sensor (SI.60) -User Manual-

Instruction Manual. HB Series Mini Level Sensor

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

2015 RIGOL TECHNOLOGIES, INC.

Voltage sensor (Product No. 3162) Range: ±1 V Resolution: 1 mv. Voltage sensor (Product No. 3161) Range: 0 to 10 V Resolution: 10 mv

TETRIS 1000 High Impedance Active Probe. Instruction Manual

9 PIECE TUNGSTEN CARBIDE HOLE SAW KIT. Model 90721

A Channel Amplifier

User s Guide TX93A. (J, K, T, E) 4-20 ma Ultra-Miniature Temperature Transmitters. Shop online at omega.com

15 Planer Stand. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

Circuit Breaker Finder

E7000, E7500, and E ma Analog Transmitters

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

HHMA2 DC / TRUE RMS AC NON-CONTACT MILLIAMMETER

VideoEase VGA 1x4 Distribution Hub (500150, ) Installation Guide

Angular Rate Sensor. Owner's Manual

Vi6208, Vi6216, Vi6232 Vi6308, Vi6316, Vi6332

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Radio Remote Controls Manual K Series

SAS Log Periodic Antenna Operation Manual

MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT

TT881 Explosion-Proof Temperature Assembly Installation and Operating Instructions

Aquaflex Universal Soil Moisture Sensor (Model SI.162-mA) -User Manual- ma Version -

WALTx-2 Instruction Manual Weatherproof Volume Control

14 Piece Slide Hammer and Puller Set

Tilting Flat Panel Wall Mount Installation Guide

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

Model 9305 Fast Preamplifier Operating and Service Manual

Tilting & Swiveling Flat Panel Wall Mount Installation Guide Model: AXS2040

User s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com

INSTRUCTION MANUAL INF Fax: (503)

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

30 Bending Brake. Model Assembly and Operating Instructions. Distributed exclusively by Harbor Freight Tools.

MICROTOOLS MICRONETBLINK KIT

Non-Submersible Industrial Pressure Transducer

METEOROLOGICAL INSTRUMENTS

One Shelf, Wall Mounted A/V Component Stand Installation Guide Model: EX101SS

LOW NOISE AMPLIFIER LN4000 OPERATING MANUAL THIS AMPLIFIER IS FOR RECEIVER ONLY. DO NOT USE WITH TRANSMITTER!

Broadband Current Probe Series Operation Manual

EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure

Transcription:

M E E T I N S T R U M E N T A T I E Turfschipper 114 2292 JB Wateringen Tel. +31 (0)174 272330 www.catec.nl info@catec.nl MAS-1 4-20 ma Soil Moisture Sensor User Manual Version 4

Decagon Devices, Inc. 2365 NE Hopkins Court Pullman WA 99163 (509)332-5600 www.decagon.com support@decagon.com 2011-2012 Decagon Devices, Inc. All rights reserved.

Contents 1. Introduction.................... 1 Customer Support...................... 1 Warranty............................. 3 Seller s Liability....................... 3 2. About the MAS-1............... 4 3. Integrating the MAS-1............ 5 Wiring............................... 6 Conventional (PLC)................... 6 Non-Conventional.................... 6 Testing the Sensor..................... 9 4. Installing the MAS-1............ 10 Procedure........................... 10 Orientation.......................... 11 Removing the Sensor.................. 11 5. Calibration..................... 12 Mineral Soils......................... 12 Potting Soil/Peat...................... 13 Rock Wool.......................... 13 6. Troubleshooting................ 14 Declaration of Conformity........... 15 Index............................ 16 i

1. Introduction 1. Introduction Thank you for choosing the MAS-1 4-20 ma Soil Moisture Sensor. These innovative sensors will enable you to monitor soil moisture accurately and affordably with a standard 2- wire, 4-20 ma analog interface for use with many data acquisition and control systems. The MAS-1 cannot be used with the standard Decagon data loggers. Customer Support If you ever need assistance with your MAS-1, or if you just have questions or feedback, there are several ways to contact us. Customer service representatives are available to speak with you Monday thru Friday, between 7am and 5pm Pacific time. NOTE: If you purchased your MAS-1 through a distributor, please contact them for assistance. E-mail: support@decagon.com or sales@decagon.com Phone: 1-509-332-5600 Fax: 1-509-332-5158 If contacting us by email or fax, please include as part of your message your instrument s serial number, your name, address, phone, fax number and a description of your problem. 1

1. Introduction Specifications Electrical Interface: Standard 4-20 ma, 2-wire analog transmitter Supply voltage: 12-32 VDC continuous Output current: 4-20 ma Overvoltage protection: Yes Reverse polarity protection: Yes Settling time: 4 seconds Wiring: Red wire: (+) supply Black wire: (-) output Shield: Not connected Measurement Type: Volumetric water content (VWC) Range: 0-100% VWC typical Resolution: Depends on current measurement (data acquisition) device Accuracy: ± 6 % VWC with generic calibration for supported growing media up to 65% VWC, above which accuracy lessens. Increased accuracy can be achieved with a medium specific calibration. For more information on how to perform your own media specific calibration, or to have Decagon s calibration service perform one for you, visit us online at http://www.decagon.com. Output: 4-20 ma current proportional to VWC Sensor measurement interval: 1 second Operating Environment Temperature: -40 to 60 C* Physical Properties Dimensions: 8.9 cm x 1.8 cm x 0.7 cm Cable: 2 m or 5 m (standard), 3 wire (22 AWG tinned Red and Black wires, 24 AWG tinned bare wire); (Custom cable length available upon request) *Note: Sensors can be used at higher temperatures under certain circumstances, please contact Decagon for assistance. 2

1. Introduction Warranty The MAS-1 has a one year warranty on parts and labor. It is activated upon the arrival of the instrument at your location. Seller s Liability Seller warrants new equipment of its own manufacture against defective workmanship and materials for a period of one year from date of receipt of equipment (the results of ordinary wear and tear, neglect, misuse, accident and excessive deterioration due to corrosion from any cause are not to be considered a defect); but Seller s liability for defective parts shall in no event exceed the furnishing of replacement parts F.O.B. the factory where originally manufactured. Material and equipment covered hereby which is not manufactured by Seller shall be covered only by the warranty of its manufacturer. Seller shall not be liable to Buyer for loss, damage or injuries to persons (including death), or to property or things of whatsoever kind (including, but not without limitation, loss of anticipated profits), occasioned by or arising out of the installation, operation, use, misuse, nonuse, repair, or replacement of said material and equipment, or out of the use of any method or process for which the same may be employed. The use of this equipment constitutes Buyer s acceptance of the terms set forth in this warranty. There are no understandings, representations, or warranties of any kind, express, implied, statutory or otherwise (including, but without limitation, the implied warranties of merchantability and fitness for a particular purpose), not expressly set forth herein. 3

2. About the MAS-1 2. About the MAS-1 The MAS-1 measures the dielectric constant of the soil in order to find its volumetric water content. Since the dielectric constant of water is much higher than that of air or soil minerals, the dielectric constant of the soil is a sensitive measure of water content. The MAS-1 supplies a 70 MHz oscillating wave to the sensor prongs that induces an electromagnetic field in the medium (soil) surrounding the sensor. The charging and discharging of the sensor is controlled by the dielectric of the surrounding soil. A microprocessor on the MAS-1 measures the charging of the sensor, and therefore the dielectric constant of the soil which is related to the water content of the soil. The microprocessor makes a dielectric measurement and updates the transmitted current once per second. The transmitted 4-20 ma current can be converted to the water content of the soil using a simple calibration function. The MAS-1 was designed to be used with standard 4-20 ma controllers and monitoring systems. It cannot be used with Decagon logging systems. For more information about using Decagon logging systems please contact Decagon s customer support representatives. 4

3. Integrating the MAS-1 3. Integrating the MAS-1 A 4-20mA system generally consists of a sensor, a transmitter, a power supply, and a device to read the current being transmitted through the current loop. The MAS-1 is an integrated sensor and 4-20mA transmitter. When the MAS-1 is powered by the Power Supply, it transmits a current though the loop that is proportional to the soil dielectric permittivity and therefore the soil volumetric water content. In Figure 1, the current loop is shown by the dotted line labeled I=4-20mA. The arrows indicate the direction of the current. Figure 1-4-20mA current loop diagram The MAS-1 uses a microcontroller to regulate the interval at which it takes measurements. It takes one second from the time it is powered up to take its first measurement and transmit current though the loop. The trasnmitted current will reach a stable value within four seconds of power up. After the initial four second startup, measurements are taken every one second, while the current in the loop is continuously maintained. Since the measurement intervals are controlled 5

3. Integrating the MAS-1 by the MAS-1 itself, there is no need to pulse the excitation voltage. A constant supply voltage should be applied in order for the MAS-1 to function as it is designed. Wiring Conventional (PLC) A Programmable Logic Controller (PLC) is typically used to read the current transmitted through the MAS-1. The red wire (see Figure 2) of the MAS-1 is connected to a voltage output terminal that is able to supply 12-32 VDC. The black wire is connected to an input terminal that is capable of accepting a current input ranging from 4 ma to 20 ma. For the MAS-1 to function properly, the voltage drop from the red to the black lead must be 12 V or greater. Figure 2 - Typical wiring connection Non-Conventional When using a device, such as a data logger, that does not have an input capable of measuring current, a pickoff resistor can be used as shown in Figure 3. Assuming that the Single Ended Input has an input impedance, or resistance, much 6

3. Integrating the MAS-1 larger that of R Volt, then all of the current in the 4-20 ma loop passes through R Volt. If the data logger can measure the voltage drop over the R Volt, then the current can be calculated as I = V measured / R Volt (1) where I (ma) is the 4-20 ma current, R Volt (ohms) is the resistance of the pickoff resistor, and V measured (mv) is the voltage drop over R Volt. Figure 3 - Wiring connection for devices without current inputs The optional 100uF capacitor shown in parallel with the R Volt reduces measurement noise. It should have a voltage rating higher than the largest supply voltage. Be sure to observe correct polarity. The MAS-1 requires a voltage of at least 12 V. This limits the value of R Volt since part of the total voltage drop will be across the resistor. Equation (2) can be used to determine the maximum value for R Volt. Table 1 shows some resistance values. 7

3. Integrating the MAS-1 V Supply - 12 = 0.02 R Volt Max (2) Supply Voltage Load 13 V 50 ohms 24 V 600 ohms 32 V 1000 ohms Table 1 Maximum resistance values for R Volt at specified voltages The MAS-1 sensor has several advantages over voltage-output sensors, even for voltage-input data loggers. The MAS-1 supply voltage doesn t need to be regulated for the sensor to work properly; it can be any value between 12 and 32 volts, without affecting sensor output. When using a current-based sensor like the MAS-1, the signal is not affected by electrical resistance in the cable, so the sensor output is not affected by cable length or wire gauge. The MAS-1 requires only two conductors, so long lines are both lower in noise and less expensive. With the MAS-1sensor the source impedance is small, and a current loop is highly immune to noise on the line. Measured voltage can be tailored to a particular data acquisition system simply by adjusting the value of R Volt. A typical application might be to use a MAS-1 with a 12 volt supply and a R Volt value of 1 ohm. The output voltage range is the product of the current and the resistance (Equation (1)), so for 4-20 ma it would be 4 to 20 mv. 8

3. Integrating the MAS-1 Testing the Sensor After integrating the MAS-1 into your PLC or other data acquisition system, it is always a good idea to test the sensor output to verify that it is functioning correctly with your system. Two convenient test conditions are having the sensor surrounded by air and water. To test in air, suspend the sensor from the cable, making sure that it is at least 6 inches from any object. To test in water, place the sensor in a bucket of tap water (do not use de-ionized or distilled water). The entire sensor (prongs + black plastic electronics portion) should be immersed in water, and should be at least 2 inches from any container surface. Under these conditions, the sensor should transmit in the following ranges (approximate): Air: 3.4 to 4.7 ma Tap water: 18.1 to 22.4 ma Note that the sensor output can go above 20 ma and below 4 ma. 9

4. Installing the MAS-1 4. Installing the MAS-1 When selecting a site for installation, it is important to understand that the soil adjacent to the sensor surface has the strongest influence on the sensor reading and that the sensor measures the volumetric water content. Therefore any air gaps or excessive soil compaction around the sensor can profoundly influence the readings. Also, do not install the sensors adjacent to large metal objects such as metal poles or stakes. This can attenuate the sensor's electromagnetic field and adversely affect sensor readings. Because the MAS-1 has gaps between its prongs, it is also important to consider the size of the media you are inserting the sensor into. It is possible to get sticks, bark, roots or other material stuck between the sensor prongs, which will adversely affect readings. Finally, be careful when inserting the sensors into dense soil, as the prongs will break if excessive sideways force is used when pushing them in. Procedure 1. The MAS-1 sensor was designed for easy installation into the soil. After digging a hole to the desired depth, push the prongs on the sensor into undisturbed soil at the bottom of the hole or into the sidewall of the hole. Make sure that the prongs are buried completely up to the black overmolding. The sensor may be difficult to insert into extremely compact or dry soil. If you have difficulty inserting the sensor, try loosening the soil somewhat or wetting the soil. Never pound it in! 10

4. Installing the MAS-1 2. Carefully backfill the hole to match the bulk density of the surrounding soil. Be careful to not over stress the cable or overmold by bending when installing the sensor. Orientation The sensor can be oriented in any direction. However, orienting the flat side perpendicular to the surface of the soil will minimize effects on downward water movement. Removing the Sensor When removing the sensor from the soil, do not pull it out of the soil by the cable! Doing so may break internal connections and make the sensor unusable. 11

5. Calibration 5. Calibration The current transmitted by the MAS-1 is proportional to the dielectric permittivity of the medium surrounding the sensor, and therefore its volumetric water content (VWC) of the medium. The VWC is calculated by applying a calibration equation to the current transmitted by the MAS-1. The following are generic calibration equations for common growth media. Applying these equations will generally result in accuracy of ± 6% VWC as long as the electrical conductivity of the medium is less than 8 ds/m. If you wish to use the MAS-1 in a medium that isn't listed below, if you need better than ± 6% accuracy, or if you are working in a high salinity material, then you should develop a custom calibration for your particular medium. See www.decagon.com for step-by-step instructions on developing a custom calibration. Decagon can also develop a custom calibration for your medium; contact Decagon for more details on the calibration service. Mineral Soils A single calibration equation will generally result in good accuracy for all mineral soil types with electrical conductivity < 8 ds/m. VWC is given by: VWC = 0.00328 * ma 2-0.0244 * ma - 0.00565 If your data acquisition system isn t capable of higher order mathematical operations, the mineral soil calibration can be 12

5. Calibration approximated by the following linear model. This will result in slightly worse accuracy at low VWC, with errors becoming large above 35% VWC. VWC= 0.0479 * ma - 0.391 Potting Soil/Peat The following equation can be used to convert MAS-1 transmitted current into VWC in potting soil and peat potting mixes. Please note that different potting soil types are quite variable, so this calibration equation may not result in good accuracy in your particular mix (although precision should still be good). We recommend a custom calibration for best accuracy when using the MAS-1 in potting soils. VWC = 0.00531 *e (0.29*mA) Rock Wool The MAS-1 was calibrated in Groden Expert rockwool at several electrical conductivities. VWC can be calculated as: VWC = 0.00446 * ma 2-0.0359 * ma + 0.0741 13

6. Troubleshooting 6. Troubleshooting If you encounter problems with the MAS-1, they will usually be caused by one of two situations If the MAS-1 readings in air and/or water are outside the ranges given in the Testing the Sensor section, then there is likely a problem with the connection to the PLC or other data acquisition system. Check the wiring and check to make sure that the supply voltage is in the specified range. If the MAS-1 is reading a negative value for VWC while it is inserted into the soil, make sure that you have good sensor-to-soil contact. When inserted, the MAS-1 should be completely covered up past the black overmolding. Removing and re-installing the full length of the sensor with good sensor-to-soil contact should remedy this problem. If problems persist, contact Decagon for assistance. 14

Declaration of Conformity Declaration of Conformity Application of Council Directive: Standards to which conformity is declared: 2004/108/EC 2011/65/EU EN61326-1:2013 and EN 62321:2009 Manufacturer s Name: Decagon Devices, Inc. 2365 NE Hopkins Court Pullman, WA 99163 USA Type of Equipment: Model Number: Soil moisture sensor MAS-1 Year of First Manufacture: 2011 This is to certify that the MAS-1 soil moisture sensor, manufactured by Decagon Devices, Inc., a corporation based in Pullman, Washington, USA meets or exceeds the standards for CE compliance as per the Council Directives noted above. All instruments are built at the factory at Decagon and pertinent testing documentation is freely available for verification. 15

Index Index C Calibration 12 Customer support 1 D Declaration of conformity 15 Dielectric constant 4 E Email 1 F Fax 1 Functional testing 9 I Installation 10 Integration 5 O Orientation 11 P Phone 1 S Seller s liability 3 Specifications 2 16

Index T Troubleshooting 14 W Warranty 3 Wiring 6 17