TES-1306 DIGITAL THERMOMETER INSTRUCTION MANUAL 1. SAFETY INFORMATION

Similar documents
TYPE - K.J.E.T. PRINTING THERMOMETER. Model INSTRUCTION MANUAL

Printing Humidity/Temperature Meter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

EM5. Multifunctional Environmental Meter. Sealed Unit Parts Co., Inc. User Manual

RF/High Frequency Meter HF-A3G

Pen-type DIGITAL MULTITESTER

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

ATK Clamp Meter

USER'S MANUAL DMR-6700

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Microwave Meter. Instruction Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

400Amp True RMS AC/DC Clamp Meter Model EX613

312, 316, 318. Clamp Meter. Users Manual

# Digital Multimeter

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

CONTENTS MS2033A. 1.Introduction Safety Information...01

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

Instruction Manual IDM 98-III & IDM 99-III Digital Multimeters

AC/DC True RMS Power Clamp Meter ELECTRONIC TEST INSTRUMENTS MODEL 325

Digital Clamp Meter (TRMS) Model : 2727

IDM 98-III & IDM 99-III Digital Multimeters

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

User Manual 4 wire Earth Resistance Tester Model GRT300

600A Clamp Meters w/tightsight Display

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DM-45 Digital Multimeter

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

Model: Pro95 TRUE RMS MILLIAMP CLAMP METER

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

Autoranging Multimeter Extech EX503

30XR-A Professional Digital Multimeter Users Manual

1507/1503. Insulation Testers. Users Manual

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) 1327 INSTRUCTION MANUAL

User s Guide. 400A AC/DC Clamp Meter. Model MA220

MS2109A AC/DC Clamp Meter. User Manual. Contents

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

USER GUIDE. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

Multifunction AC/DC Voltage Tester

BENNING. CM7 Electrical Tester. Service Information

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

USER MANUAL. Extech EX850 True RMS 1000 Amp Clamp Meter. Bluetooth TM and Android TM ready. Patented

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

400Amp True RMS AC Clamp Meter + NCV

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

VC835 DIGTAL MULTIMETER Operation Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Model: &

INSTRUCTION MANUAL LM195 LED LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Visit us at

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

Handheld Digital Multimeter

ET-3888 True RMS Clamp Meter. User Manual

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

True RMS Digital Multimeter Model:

CLAMP-ON METER 670. User Manual

Model UT10A: OPERATING MANUAL Table of Contents (1)

Model UT511 OPERATING MANUAL

INSTRUCTION MANUAL LM192 LIGHT METER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING CONTENTS. Precautions 1. SAFETY INFORMATION

Item ref: UK MTTR01 TRUE RMS DIGITAL MULTITESTER WITH USB INTERFACE. User Manual

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

IR-829 Infrared Thermometer User Manual

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DVM1190 DIGITAL MULTIMETER

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

Model : OPERATING MANUAL Table of Contents (1)

AMM-1022 Digital Multimeter USER`S MANUAL

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Model UT201/202: OPERATING MANUAL. Table of Contents

USER'S MANUAL DMR-4350

R/C SMD Tweezers Multimeter Model RC200

OPERATOR S INSTRUCTION MANUAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

KMD-S04 Multímetro de bolsillo

DIGITAL LIGHT METER TES-1337 INSTRUCTION MANUAL CONTENTS

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User s Guide. Model Dual Input Type J/K Digital Thermometer INTRODUCTION

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Table of Contents Title Page

Non-Contact Infrared Thermometers. 8818H/8819H/8828H series. Operation Manual

OPERATIONS MANUAL DP-110 IN-DUCT DIGITAL PSYCHROMETER TABLE OF CONTENTS

Transcription:

DIGITAL THERMOMETER TES-1306 INSTRUCTION MANUAL TES ELECTRICAL ELECTRONIC CORP. 1. SAFETY INFORMATION This instrument is a digital thermometer for use with any K/J-type thermocouple as temperature sensor. Temperature indication follows National Bureau of Standards and IEC584 temperature / voltage tables for K/J-type thermocouples. Read the following safety information carefully before attempting to operate or service the meter. Use the meter only as specified in this manual; otherwise, the protection provided by the meter may be impaired. Environment conditions Altitude up to 2000 meters Relatively humidity 90% max. Operation Ambient 0 ~40 Maintenance & Clearing Repairs or servicing not covered in this manual should only be performed by qualified personnel. Periodically wipe the case with a dry cloth. abrasives or solvents on this instruments. Do not use Safety symbols Meter is protected throughout by double insulation or reinforced insulation. When servicing, use only specified replacement parts. Comply with EMC

2. SPECIFICATIONS 2-1 Electrical Specifications Measurement Range : Type J : -200 to 760-328 to 1400 1 Type K : Resolution : 0.1, 1, 0.2, 2-200 to 1370-328 to 2498 Maximum Voltage at Thermocouple Input : 60V dc,or 24Vrms ac RF Field Derating : Strong RF fields and low-frequency adversely affect accurate measurement. Operating Temperature and Humidity: 0 to 40 (32 to 104 ), 0-80%RH Storage Temperature and Humidity: -10 to 60 (14 to 140 ), 0-70%RH 2 Basic Accuracy: ( @23± 5 Calibration ) Accuracy are± (...% of reading + degree ) at 18 to 28 with relative humidity up to 80% For single thermocouple measurements Range Function Resolution Accuracy Type K Type J -200 ~-50-200 ~-50 (0.5%rdg+1.0 ) 0.1-50 ~0-50 ~0 (0.2%rdg+1.0 ) 0 ~200 0 ~150 (0.1%rdg+ 0.8 ) 1 200 ~1370 150 ~760 (0.2%rdg+ 2 ) -328 ~-58-328 ~-58 (0.5%rdg+ 2.0 ) 0.2-58 ~32-58 ~32 (0.2%rdg+ 2.0 ) 32 ~392 32 ~302 (0.1%rdg+1.6 ) 2 392 ~2498 302 ~1400 (0.2%rdg+3 ) For T1-T2 Measurements accuracy is Basic accuracy add 0.2%rdg. NOTE The basic accuracy specification does not include the error of the probe. Please refer to the probe accuracy specification for additional details. Temperature Coefficient: For ambient temperatures from 0 to 18 and 28 to 40

( 32 to 64 and 82 to 104 ) For each ( ) ambient below 18 ( 64 ) or above 28 ( 82 ), add to the accuracy specifications: 0.01% of reading + 0.03 ( 0.01% of reading + 0.06 ) 2-2 General Specifications Unit and Sign Display : Decimal point. 3 the operating voltage. Power Requirement: 9-Volt battery, NEDA 1604 or JIS 006P or IEC6F22 Battery Life (typical): 100hours ( Alkaline Battery ) Dimensions: 135 (L)x 72(W)x 31(H)mm, 5.3 (L)x 2.8(W)x 1.2(H)inches Weight: Approx. 235g with battery Accessories: Battery, Instruction Manual. Holster ( option ). 3. NAME OF PARTS AND POSITIONS 4 Fahrenheit temperature scale Celsius temperature scale H MAX MIN Low Battery Negative polarity Data hold MAX hold MIN hold REL Relative mode Over Range Indication: " OL " appears on the display. Break or no input indication: appears on the display. Low Battery Indication: The " " is displayed when the battery voltage drops below 1). LCD Display: 4 digits with a maximum reading of 2500, and indications or minus sign " ", data hold " H ", maximum hold "MAX". minimum hold

MIN "T1", "T2", "T1-T2", " ", " ",low battery " " etc. 2). ON/OFF: The on/off key will turn the thermometer on and off. 3). MAX/MIN: The max/min key will turn the display into Maximum and Minimum mode. Press it once and the meter will show the Maximum reading. Press it again and the meter will show the Minimum reading. If we hold this key for 2 seconds, the meter will be back to the normal mode. If MAX/MIN mode is selected, except HOLD and /, all function key will be disabled. 5 4). HOLD: Press this key will hold the data. If we press and hold this key under power off then press the on/off button, the thermocouple type will be set as J-type when it is on. The default power on thermocouple type is set as K-type. 5). T1 Thermocouple Input Connector. 6). T1/T2/T1-T2 : When we first power the meter on, T1 will be shown. If we press this key once, the meter will show T2. If we press it again, T1-T2 will be shown. If we press it again, the meter will show T1, T2, T1-T2 in circulation. If this key been pressed again, it will turn the meter to default reading ( that will be T1). 7). REL: Press this key will turn the meter into relative mode. The reading will first show zero and then the reading change relate to the setting time will be shown. Press it again will show relative value. If hold this key 2 seconds the meter will be back to the normal mode. 8). / : Press this key will change the temperature scale between and. 9). T2 Thermocouple Input Connector. 10). ZERO: The ZERO controls allow you adjust offset value to optimize measurement accuracy for a particular thermocouple at a particular temperature. 4. RECALIBRATION PROCEDURE 6 The thermometer should be calibrated once a year to ensure its accuracy is within specifications. The required equipment is listed below: Type J: Type K: 0.0 adjust VR4. 0.0 adjust VR1. Type K:199.0 adjust VR3. Type K: 1000 adjust VR2. WARNING o avoid electrical shock, do not use this instrument when voltages exceeding 24VAC or 60VDC are present. The probe tip is electrically connected to the output terminals.

7 5. OPTIONAL ACCESSORY K ( CA ) type thermocouple. Model Range Tolerances Description 8 TP-K02: Available for temperature measurement of liquid, gels or air. TP-K01-50 to 200 Bead probe -58 to 392 ±2.2 or±0.75% (±3.6 or ±0.75%) with Teflon tape insulation. Maximum insulating temperature : 260 TP-K02 immersion probe -50 to 1000-58 to 1832 ±2.2 or±0.75% (±3.6 or ±0.75%) 3.2φ 150 mm metal sheath 100 cm Compensating wire TP-K03 Surface probe -50 to 750-58 to 1382 ±2.2 or±0.75% (±3.6 or ±0.75%) 100 cm Compensating wire 12.5φ x 94 mm handle TP-K03: Available for flat or curved surface measurement. TP-K01: Available for general condition, especially for complex and any place hard to reach.

9

TES ELECTRICAL ELECTRONIC CORP. 7F, No. 31, Lane 513, Rui Guang Road, Neihu Dist. Taipei. Taiwan, R. O. C. Tel : (02) 2799-3660 Fax : 886-2-2799-5099 E-Mail : tes@ms9.hinet.net http://www.tes.com.tw June-2000-4