Advanced Test Equipment Rentals ATEC (2832)

Similar documents
SAS-551 Passive Monopole Antenna Operation Manual

SAS-562B Active Loop Antenna Operation Manual

SAS-563B Active Loop Antenna Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

Current Probe Fixture Instruction Manual

Broadband Current Probe Series Operation Manual

Broadband Current Probe Series Operation Manual

Bulk Current Injection Probe Test Procedure

AK-18G Antenna Kit Operation Manual

TDS-535 Tuned Dipole Set Operation Manual

SAS-543 Biconical Antenna Operation Manual

SAS Log Periodic Antenna Operation Manual

AK-285R Shielding Effectiveness Antenna Kit Operation Manual

Advanced Test Equipment Rentals ATEC (2832)

ELECTRIC FIELD PROBE ANTENNA MODEL PEF-10A. 20 Hz 1 MHz

Model 3106 Double-Ridged Waveguide Horn

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

Model 3110B Biconical Antenna

HydroLynx Systems, Inc.

GT-1050A 2 GHz to 50 GHz Microwave Power Amplifier

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

MODEL 3810/2 Line Impedance Stabilization Network

Glass Electrode Meter

Model 3101, 3102 and 3103 Conical Log-Spiral Antennas

Model 5100F. Advanced Test Equipment Rentals ATEC (2832) OWNER S MANUAL RF POWER AMPLIFIER

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Archived 3/18/10 USER MANUAL EMCO MODEL 3141 BICONILOG TM LOG-PERIODIC / T BOW-TIE ANTENNA Rev A 01/97

TETRIS User's Guide. High Impedance Active Probe DO177-1

COMBILOG ANTENNA MODEL AC MHz. rev: 0202

PAMS. User s Manual. Portable Attenuation Measurement System. The solution for making easy shielding effectiveness measurements.

Model 3148 & Log-Periodic Dipole Array Antenna

Broadband Power Amplifier

Model 1791 VHF Radio User's Manual

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

PI-10 Broadband Power Indicator

Broadband Step-Up Transformer. User Manual

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

SPM-50 RF Spectrum Power Meter PC Software User Manual

BROADBAND PREAMPLIFIER MODEL BPA khz 1 GHz

AMP-12 OPERATOR S MANUAL

Current Probes. User Manual

Instruction Manual Model M Switch, DPDT, Manual Select

SIR, RADAN and UtilityScan are registered trademarks of Geophysical Survey Systems, Inc..

Agilent X-Series Signal Analyzer This manual provides documentation for the following X-Series Analyzer: CXA Signal Analyzer N9000A

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

87415A microwave system amplifier A microwave. system amplifier A microwave system amplifier A microwave.

o-ring grease can be used to hold the o-ring in the groove during installation.

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

860 DSP & 860 DSPi Multifunction Interactive Cable Analyzer. Section VI: Appendix

Model Series. Current Probes MANUAL L L. ETS-Lindgren February 2005 Rev D PN

AMP-13 OPERATOR S MANUAL

Double-Ridged Waveguide Horn Antennas

PHV RO High Voltage Passive Probe. Instruction Manual

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

Introduction. Specifications. Features. Controls. Model 103

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

REMOTE LOOP ANTENNA MODEL ALR khz 30 MHz

Model 7000 Low Noise Differential Preamplifier

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

o-ring grease can be used to hold the o-ring in the groove during installation.

Model 3116 Double-Ridged Waveguide Horn

SDI SPECTRADYNAMICS, INC. LOW NOISE FREQUENCY REFERENCE OPERATING MANUAL

M302RM OPERATING MANUAL

200Amp AC Clamp Meter + NCV Model MA250

Model 9305 Fast Preamplifier Operating and Service Manual

User s Guide. 400A AC/DC Clamp Meter. Model MA220

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

COUPLING DECOUPLING NETWORK MODEL CDN-AF4

PKT 512A-RO High Impedance Passive Cable Divider

TA MHz oscilloscope probe TA MHz oscilloscope probe

SEARCH LITE OPERATION MANUAL

INSTALLATION AND OPERATING MANUAL

CALIBRATED IMPULSE GENERATOR MODEL CIG khz 1 GHz

PHV 1000-RO High Voltage Passive Probe. Instruction Manual

KeyPre KP6 - Electronic Instrument Preamplifier

Operator s Manual. PP016 Passive Probe

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

PI-150 Broadband Power Indicator

Instruction Manual Model Upconverter

Active Monopole Antenna

PIEZO FILM LAB AMPLIFIER

DIGITAL SOUND LEVEL DSM8930 METER USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

2100L Broadband Power Amplifier

Wilcom MODEL T136BSBZW CIRCUIT TEST SET. Operating Instructions

Model 3140B BiConiLog Antenna User Manual

Model BiConiLog Antenna. User Manual

Wilcom MODEL T136BGMZW CIRCUIT TEST SET. Operating Instructions

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Complimentary Reference Material

DM-45 Digital Multimeter

Instruction Manual Model Upconverter

Using the USB Output Port to Charge a Device

Log Periodic Antenna

Model 3180B Mini-Bicon Antenna User Manual

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

HP 86290B RF PLUG-IN GHz HEWLETT PACKARD

411LA Broadband Power Amplifier

DUAL CHANNEL BROADBAND LINEAR AMPLIFIER Model A800D

Advanced Test Equipment Rentals ATEC (2832)

Transcription:

Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) A.H. Systems Model Active Monopole Antennas Active Monopole Antenna Series Operation Manual 1

TABLE OF CONTENTS INTRODUCTION 3 SPECIFICATIONS 5 OPERATING INSTRUCTIONS 7 ANTENNA FORMULAS 9 PREAMPLIFIER ALIGNMENT 10 CALIBRATION 11 MAINTENANCE 12 WARRANTY 13 2

INTRODUCTION Model Frequency Range Part Number Description SAS-550-1B 9 khz 60 MHz 2380 Active Monopole Antenna, Battery Powered SAS-550-2B 100 Hz 60 MHz 2381 Active Monopole Antenna, Battery Powered 3

INTENDED PURPOSES This equipment is intended for general laboratory use in a wide variety of industrial and scientific applications and designed to be used in the process of generating, controlling and measuring high levels of electromagnetic Radio Frequency (RF) energy. It is the responsibility of the user to assure that the device is operated in a location which will control the radiated energy such that it will not cause injury and will not violate regulatory levels of electromagnetic interference. RANGE OF ENVIRONMENTAL CONDITIONS This equipment is designed to be safe under the following environmental conditions: Indoor use Altitude: up to 2 km Temperature: 5 C to 40 C Maximum relative humidity: 80% for temperatures up to 31 C. Decreasing linearly to 50% at 40 C Pollution degree 2: Normally non-conductive with occasional condensation. While the equipment will not cause hazardous condition over this environmental range, performance may vary. 4

SPECIFICATIONS GENERAL DESCRIPTION The A.H. Systems active monopole antennas are active, general-purpose, receive-only antennas which cover the 100 Hz 60 MHz frequency range. They are ideal for instantaneous bandwidth scanning (without tuning) of electric fields in its frequency range and can drive any receiver with an input impedance of 50 Ω. Each unit comes with a telescoping rod, ground plane with a high impedance matched preamplifier and battery charger. Review this manual and become familiar with all safety markings and instructions. Verify that the antenna impedance is compatible with the receiver impedance. ANTENNA SPECIFICATIONS SAS-550-1B Active Monopole Antenna specifications: Frequency Range...9 khz 60 MHz Antenna Factor (db/m)...0.1 Flatness...+/- 0.5 db from 20 khz 30 MHz +/- 5 db whole range Sensitivity...5 dbµv/m @ 10 khz -20 dbµv/m @ 1 MHz Dynamic Range...96 db @ 10 khz 122 db @ 1 MHz Saturation... Output Connector Type...BNC(f) Input Power...12 Vdc Battery Weight...4.7 lbs. / 2.1 kg Size (W x H x D)...18" x 18" x 41" 46 cm x 46 cm x 104 cm SAS-550-2B Active Monopole Antenna specifications: Frequency Range...100 Hz 60 MHz Antenna Factor (db/m)...0.1 Flatness...+/- 0.5 db from 2 khz 30 MHz +/- 24 db whole range Sensitivity...5 dbµv/m @ 10 khz -20 dbµv/m @ 1 MHz Dynamic Range...96 db @ 10 khz 122 db @ 1 MHz Saturation... Output Connector Type...BNC(f) Input Power...12 Vdc Battery Weight...4.7 lbs / 2.1 kg Size (W x H x D)...18" x 18" x 41" 46 cm x 46 cm x 104 cm 5

OPERATING INSTRUCTIONS ASSEMBLY INSTRUCTIONS To prepare the antenna for operation, attach the telescoping rod antenna element to the top of the high impedance preamplifier. Connect the rod antenna by pushing straight down on the female connector on top of the amplifier. Do not apply excessive sideways force, as this can cause the antenna center-pin to break. Do not operate the Monopole antenna with the Battery Charger connected. SETUP INSTRUCTIONS The amplifier and ground plane can be mounted to any tripod with a 1/4-20 attaching stud. Attach the rod antenna to the connector on the top of the amplifier. Extend the rod antenna to 41" (104 cm) above the ground plane. Connect the output BNC connector on the side of the amplifier to the input of a 50 Ω receiver or spectrum analyzer. Establish a ground connection to the ground plane if required by the test specification. NOTE: The on/off toggle switch is a locking type to prevent accidental turn-on or turn-off. Pull out on the toggle handle and push up to turn the amplifier power on. Pull out and push down to turn it off. The POWER indicator LED will illuminate and stay lit as long as the battery has sufficient voltage to power the preamplifier. If the LED does not illuminate, do not use the preamplifier until the battery has been recharged. GENERAL USE INSTRUCTIONS The calibration tables shown provide a listing of the frequency of operation and its antenna factor in db/m. The field strength is the receiver voltage in dbµv plus the antenna factor (refer to the antenna factor calibration) plus any cable loss. When making a measurement, mount the antenna on an appropriate mast or tripod. Ensure that the active monopole antenna is turned on and use the appropriate correction factors. The active monopole antenna is easy to set up and provides good reception with a minimal need for space. Its flat 0 db antenna factor makes it a convenient choice when calculating the field intensity. The signal field strength is the receiver voltage in dbµv plus the antenna factor (refer to the antenna factor calibration tables) plus any cable loss. 6

CHARGING THE BATTERY Depending on the model (if applicable), position the input voltage selector located next to the wall plug on the back of charger to the proper voltage (either 110 120 Vac, 60 Hz or 220 240 Vac, 50 Hz). Be sure to check the available voltage and adjust the voltage selector as needed before use. The amplifier ON-OFF switch must be in the OFF/CHARGE position to charge the battery. One hour of amplifier operation will be obtained for each hour of charge up to a maximum of 8 hours operation. Charging for up to 24 hours will not damage the battery. Using the battery charger to operate the amplifier directly is not recommended. REPLACING THE BATTERIES Remove the four 6-32 flat head screws from the bottom of the ground plane. Disconnect the battery lead from the PC card. Re-connect the lead from the new battery pack to the PC card. Snug the four 6-32 flat head screws. Insure that the orientation of the amplifier box is that the input rod connector is facing toward the center of the ground plane. ECF-10 (Equivalent Capacitance Fixture) The ECF-10 is an equivalent capacitance fixture constructed per IEEE 291 and ARP 958. This is an indispensable tool used for gain adjustment and calibration of the active monopole antennas. The ECF-10 is used as a signal substitution source when calibrating the active monopole antennas. Refer to the alignment and calibration procedures below. 7

ANTENNA FORMULAS AND CALCULATIONS A specific antenna factor is associated with each frequency. This number is to be added to the receiver reading (in dbµv) to convert to field intensity in dbµv/m. EXAMPLE: Assume the transmitter to be measured is operating at 1 MHz and the receiver reading indicates 44.0 dbµv AF (db/m) = 0.1 Receiver reading (dbµv) = 44 dbµv Cable loss (db) = 0.7 Field Intensity = AF + receiver reading + cable loss Field Intensity = 0.1 + 44.0 + 0.7 Field Intensity = 44.8 dbµv/m 8

CALIBRATION Preamplifier Alignment Preliminary alignment is required on all manufactured active monopole antennas prior to placing the units in stock for sale. All preliminary test sheets and ITP will be maintained and a copy stored with the unit to be placed in stock. Turn on the equipment and allow 15 minutes for warm-up. Set up the equipment to 50 MHz center frequency, 10 MHz Span/DIV, 2 db/div amplitude, 300 khz resolution and 80 dbµv reference amplitude on the spectrum analyzer. Set the output level on the tracking generator to 72 dbµv. Connect the tracking generator to the spectrum analyzer as shown in Figure 3 and the 50 Ω load connected to the antenna signal output port (B). Save the trace as trace A. Connect the tracking generator cable to the fixture terminated with 50 Ω (A) and connect the spectrum analyzer cable to the signal output port (B) per Figure 3. Adjust the resistor pots (R 6, R 7 and R 8 Figure 1) to match the following curve (Figure 2). R6 adjusts high-frequency gain R7 adjusts low-frequency gain R8 adjusts overall gain Figure 1 Figure 2 Verify that the low frequency cut off is below specification. Records providing evidence that the required final inspection and tests are carried out shall be maintained and shall be available for review by the customer and third party inspectors. Such records include signed off ITPs, job cards, nonconformance reports, test reports and inspection reports, if any. 9

Measurement System Checks MIL-STD-461E changed from the previous versions with the addition of making a pre-test calibration (measurement system checks) as part of the test procedure. When testing to the previous standards, one could go through an entire test suite with a faulty cable and never know it. This cable could adversely affect the results for one or many tests, depending on how often it was used. The 10 pf capacitor (ECF-10) used with the rod antenna in the measurement system check simulates the capacitance of the rod element to the outside world. With the rod antenna, the electric field present induces a voltage in the rod that is applied to the preamplifier circuitry. One of the functions of the preamplifier is to convert the high impedance input of the antenna element to the 50 Ω impedance of the measurement receiver. The 10 pf capacitor ensures that the correct source impedance is present during the check. For measurement system checks, establishing the correct voltage at the input to the 10 pf capacitor can be confusing. Since, the electrical length of the 104 cm rod is 0.5 meters, the conversion factor for the induced voltage at the input to the 10 pf capacitor is 6 db/m. If the limit at the measurement system check frequency is 34 dbµv/m, the required field level to use for measurement system check is 6 db less than this value or 28 dbµv/m. The voltage level that must be injected is: 28 dbµv/m 6 db/m = 22 dbµv Since the input impedance at the 10 pf capacitor is very high, a signal source must be loaded with 50 Ω (termination load or measurement receiver) to ensure that the correct voltage is applied. A T- connector can be used with the signal source connected to the first leg, the 50 Ω load connected to the second leg, and the center conductor of the third leg connected to the 10 pf capacitor. 10

Active Monopole Calibration The antenna factor for the rod antenna shall be determined by measuring the signal transfer characteristics of the matching device and assuming that the antenna is a short monopole with an infinite ground plane. Set up the monopole to be calibrated and the test equipment per Figure 3. Allow all equipment to warm up for 15 minutes. NOTES Figure 3 * Also referred to as a Dummy Antenna. If the VSWR of the receiver or signal generator is low, pads may not be needed or reduced to 6 db or 3 db. With the equipment connected as shown and a 50 Ω termination on the T-connector (A), measure the received signal voltage V L in dbµv at the signal output port (B). Leaving the RF output of the signal generator unchanged, transfer the 50 Ω termination to the signal output port (B) and transfer the receiver input cable to the T-connector (A). Measure the drive signal voltage V D in dbµv. Subtract V L from V D and add 6 db to obtain the antenna factor (in db) of the antenna. Records providing evidence that the required final inspection and tests are carried out shall be maintained and shall be available for review by the customer and third party inspectors. Such records include signed off ITPs, job cards, nonconformance reports, test reports and inspection reports, if any. NOTE The signal generator does not need to be calibrated, but it shall be stable. The 50 Ω termination shall have low VSWR. The spectrum analyzer shall be calibrated and have low VSWR. 11

MAINTENANCE To ensure reliable and repeatable long-term performance, annual re-calibration of your active monopole preamplifier by A.H. Systems experienced technicians is recommended. Our staff can recalibrate almost any type or brand of antenna. For more information about our calibration services or to place an order for antenna calibration, visit our website at www.ahsystems.com or call (818) 998-0223. 12

WARRANTY INFORMATION A.H. Systems Inc., warrants that our Antennas, Sensors and Probes will be free from defects in materials and workmanship for a period of three (3) years. All other products delivered under contract will be warranted for a period of two (2) years. A.H. Systems' obligation under this warranty shall be limited to repairing or replacing, F.O.B. Chatsworth, California, each part of the product which is defective, provided that the buyer gives A.H. Systems notice of such defect within the warranty period commencing with the delivery of the product by A.H. Systems. The remedy set forth herein shall be the only remedy available to the buyer, and in no event shall A.H. Systems be liable for direct, indirect, incidental or consequential damages. This warranty shall not apply to any part of the product which, without fault of A.H. Systems has been subject to alteration, failure caused by a part not supplied by A.H. Systems, accident, fire or other casualty, negligence, misuse or normal wear of materials. Except for the warranty set forth above, there are no other warranties, expressed or implied, with respect to the condition of the product or it's suitability for the use intended for them by the buyer. For prompt service, please contact our service department for a Return Material Authorization Number before shipping equipment back to us. 13