Modelling of Phasor Measurement Unit and Phasor Data Realisation with 2 Bus System

Similar documents
Study and Simulation of Phasor Measurement Unit for Wide Area Measurement System

SYNCHRONIZED PHASOR MEASUREMENT TECHNIQUES. A.G. Phadke

Engineering Thesis. The use of Synchronized Phasor Measurement to Determine Power System Stability, Transmission Line Parameters and Fault Location

Evaluation of Steady-State and Dynamic Performance of a Synchronized Phasor Measurement Unit

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

[Nayak, 3(2): February, 2014] ISSN: Impact Factor: 1.852

SHORT CIRCUIT ANALYSIS OF 220/132 KV SUBSTATION BY USING ETAP

Application of Distribution Static Synchronous Compensator in Electrical Distribution System

Teaching Distance Relay Using Matlab/Simulink Graphical User Interface

Designing and Control of Converters used in DPFC for Mitigation of Voltage Sag and Swell In Transmission Line

FAULT AND STABILITY ANALYSIS OF A POWER SYSTEM NETWORK BY MATLAB SIMULINK

Protection of Extra High Voltage Transmission Line Using Distance Protection

Testing of Circuit Breaker and over Current Relay Implementation by Using MATLAB / SIMULINK

PRECISE SYNCHRONIZATION OF PHASOR MEASUREMENTS IN ELECTRIC POWER SYSTEMS

Analysis of Effect on Transient Stability of Interconnected Power System by Introduction of HVDC Link.

Comparative Testing of Synchronized Phasor Measurement Units

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Design and Simulation of Three Phase Shunt Active Power Filter Using SRF Theory

AN ANN BASED FAULT DETECTION ON ALTERNATOR

SIMULATION OF D-STATCOM IN POWER SYSTEM

CHAPTER 3 COMBINED MULTIPULSE MULTILEVEL INVERTER BASED STATCOM

Ultra Hight Voltge Transmission line Faults Identified and Analysis by using MATLAB Simulink

POWER SYSTEM BACKUP PROTECTION USING SYNCHRONIZED PMU

[Ahmed, 3(1): January, 2014] ISSN: Impact Factor: 1.852

Implementation and Evaluation a SIMULINK Model of a Distance Relay in MATLAB/SIMULINK

Performance of DVR & Distribution STATCOM in Power Systems

Designing Of Distributed Power-Flow Controller

Symmetrical Components in Analysis of Switching Event and Fault Condition for Overcurrent Protection in Electrical Machines

Transient stability improvement by using shunt FACT device (STATCOM) with Reference Voltage Compensation (RVC) control scheme

NEW CRITERION FOR STATOR INTER TURN FAULT DETECTION OF SYNCHRONOUS GENERATOR

Volume I Issue VI 2012 September-2012 ISSN

Real-Time-Simulation of IEEE-5-Bus Network on OPAL-RT-OP4510 Simulator

Implementation of Smart DFT-based PMU Model in the Real-Time Digital Simulator

IJESR/Nov 2012/ Volume-2/Issue-11/Article No-21/ ISSN International Journal of Engineering & Science Research

Simultaneous AC-DC Transmission Scheme Under Unbalanced Load Condition

Analysis of Voltage Source Inverters using Space Vector PWM for Induction Motor Drive

Question Paper Profile

EFFECTS OF SERIES COMPENSATION ON DISTANCE PROTECTION OF HIGH VOLTAGE TRANSMISSION LINES UNDER FAULT CONDITIONS

Arvind Pahade and Nitin Saxena Department of Electrical Engineering, Jabalpur Engineering College, Jabalpur, (MP), India

Power System Stability Enhancement Using Static Synchronous Series Compensator (SSSC)

Dynamic Model Of 400 Kv Line With Distance Relay. Director Research, The MRPC Company, Hyderabad, India 2

The Effect of Delays on Wide-Area Damping Control of Electromechanical Oscillations

Enhanced DFT Algorithm for Estimation of Phasor by PMU under Power Quality Events

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

UNIT II: WIDE AREA MONITORING SYSTEM

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Development of DFT Based MATLAB and LABVIEW Models for Phasor Measurements

Power Quality Analysis in Power System with Non Linear Load

Voltage Sag and Swell Mitigation Using Dynamic Voltage Restore (DVR)

Comparison of Wavelet Transform and Fourier Transform based methods of Phasor Estimation for Numerical Relaying

A New Fault Detection Tool for Single Phasing of a Three Phase Induction Motor. S.H.Haggag, Ali M. El-Rifaie,and Hala M.

Development of Dynamic Test Cases in OPAL-RT Real-time Power System Simulator

Power Quality enhancement of a distribution line with DSTATCOM

Discrimination between Inrush and Fault Current in Power Transformer by using Fuzzy Logic

Performance Assessment of Distance Relay using MATLAB DibyaDarshiniMohanty, Ashwin Sharma, Ashutosh Varma M.S.I.T. M.S.I.T. M.S.I.

Simulation and Comparison of DVR and DSTATCOM Used For Voltage Sag Mitigation at Distribution Side

MODELING AND SIMULATION OF UNIFIED POWER QUALITY CONDITIONER FOR POWER QUALITY IMPROVEMENT

APPLICATION OF PMUS FOR MONITORING A 50 KV DISTRIBUTION GRID

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

Improvement of Power Quality in Distribution System using D-STATCOM With PI and PID Controller

Digital Fault Recorder Deployment at HVDC Converter Stations

Power flow improvement using Static Synchronous Series Compensator (SSSC)

Implementation of D-STACTOM for Improvement of Power Quality in Radial Distribution System

ISSN: Page 298

Increasing Dynamic Stability of the Network Using Unified Power Flow Controller (UPFC)

Modeling and Testing of a Digital Distance Relay Using MATLAB/SIMULINK

CHAPTER 5 DESIGN OF DSTATCOM CONTROLLER FOR COMPENSATING UNBALANCES

[Mahagaonkar*, 4.(8): August, 2015] ISSN: (I2OR), Publication Impact Factor: 3.785

Downloaded from / 1

OPEN-PHASE DETECTION TECHNIQUES FOR CRITICAL STANDBY SUPPLIES

ISSN Vol.05,Issue.06, June-2017, Pages:

Optimal PMU Placement in Power System Considering the Measurement Redundancy

5DESIGN PARAMETERS OF SHUNT ACTIVE FILTER FOR HARMONICS CURRENT MITIGATION

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

Mitigation of voltage disturbances (Sag/Swell) utilizing dynamic voltage restorer (DVR)

Application of Wavelet Transform in Power System Analysis and Protection

DETECTION OF HIGH IMPEDANCE FAULTS BY DISTANCE RELAYS USING PRONY METHOD

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Power Quality Improvement in Distribution System Using D-STATCOM

Voltage Control and Power System Stability Enhancement using UPFC

ReliabilityFirst Regional Criteria 1. Disturbance Monitoring and Reporting Criteria

A Voltage Controlled D-STATCOM for Power Quality Improvement with DVR

Improved first zone reach setting of artificial neural network-based directional relay for protection of double circuit transmission lines

Voltage Improvement Using SHUNT FACTs Devices: STATCOM

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Improving the Transient and Dynamic stability of the Network by Unified Power Flow Controller (UPFC)

SIMULATION AND EVALUATION OF A PHASE SYNCHRONOUS INVERTER FOR MICRO-GRID SYSTEM

Performance Evaluation of Traveling Wave Fault Locator for a 220kV Hoa Khanh-Thanh My Transmission Line

Damping Power system Oscillation using Static Synchronous Series Compensator (SSSC)

Overcurrent relays coordination using MATLAB model

NOWADAYS, there is much interest in connecting various

INVESTIGATION OF HARMONIC DETECTION TECHNIQUES FOR SHUNT ACTIVE POWER FILTER

Long lasting transients in power filter circuits

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

Bus protection with a differential relay. When there is no fault, the algebraic sum of circuit currents is zero

Modelling of Dynamic Voltage Restorer for Mitigation of Voltage Sag and Swell Using Phase Locked Loop

STATCOM WITH POD CONTROLLER FOR REACTIVE POWER COMPENSATION Vijai Jairaj 1, Vishnu.J 2 and Sreenath.N.R 3

Wind Energy Stabilization Using SVPWM Based Modulated Power Filter Compensator

Transcription:

Intl J Engg Sci Adv Research 05 Sep;(3):79-83 ling of Phasor Measurement Unit and Phasor Data Realisation with Bus System Chakrapani Mishra Department of Electrical Engineering FET, Rama University, Kanpur, India chakrapanimishra700@gmail.com Dushmanta Kumar Mohanta Department of Electrical & Electronics Engineering Birla Institute of Technology, Mesra, Ranchi, India dkmohanta@bitmesra.ac.in Abstract This paper presents the modeling of Phasor Measurement Unit in MATLAB as well as Phasor data realization with bus system. With the help of simulink model of bus system comprising of PMU block in MATLAB, the real time data are obtained to understand the dynamic responses or changes, occurred in the system either in healthy condition or in faulty condition. With the help of data gathered in these situations it becomes easier to identify the unbalancing in established electrical power system & accordingly preventive action can be taken to isolate or handle the worst situation, if any within the prescribed time limit. Keywords Phasor measurement unit, positive sequence, negative sequence, zero sequence, discrete fourier transform. I. INTRODUCTION Now-a-days, Phasor measurement unit becomes the integral part of any existing power system for the study & analysis purpose of their variable dynamic parameters. In any power system some parameters like voltage, current, phase angle, balance in active & reactive power continuously changes. Sometimes, slight changes in these parameters greatly affect the whole system, but remains undetected. However, post mortem analysis is used to analyze the data & its impact on the existing system but the faulty conditions remain undetected. So, it is a tedious work to detect the same. However, with the evolution of Phasor measurement unit this task becomes easy because it keeps all the data related with the variation in voltage, current and phase angle in the existing system where it is installed & implements it for analysis purpose wherever it is required. Hence, Phasor measurement unit is realized in MATLAB to study its nature & working capability. II. PHASOR MEASUREMENT UNIT Phasor Measurement Unit has been defined by IEEE as a device that produces synchronized Phasor, frequency, and rate of change of frequency (ROCOF) estimates from voltage and/or current signals and a time synchronizing signal. []. Basically, the Phasor measurement unit (PMU) is a micro processor based device that uses the ability of digital signal processor in order to measure 50/60 Hz AC waveforms (voltages & currents) at a typical rate of 48 samples per cycle (400/880 samples per second) []. Figure shows the function block diagram of a typical PMU. Analogue inputs are derived from the voltage and current transformer [3]. A PMU may collect data from different locations in the system simultaneously and normally requires data from all three phases to extract the positive-sequence component, which is normally of interest and contains information that can be used to assess the state of the power system. The signals derived from the secondary winding of the voltage and current transformer are first converted (via A/D converters) to voltage signals with a typical range of ±0 [4]. The sampling rate must be at least twice of the cut-off frequency of the filter to satisfy the Nyquist criterion. Oversampling is used in many systems due to the better stability and accuracy that it offers [5]. The GPS (Global Positioning System) receiver normally generates a one pulseper-second signal to the phase-locked oscillator to lock the phase of the sampling clock. Higher sampling rate is always looking forward so that the accuracy of the estimation can be improved [4]. The coordinates of GPS receivers of PMUs at measuring points all over the world is determined by the satellites through GPS system. The GPS receiver also creates time stamps for the output of the microprocessor. The error of synchronization with modern units is of the order of a few hundred nanoseconds [4]. The microprocessor uses the digital signal from the A/D converter to calculate the quantities required, including the magnitude and phase angle (calculated by the application of discrete Fourier Transform) of the voltage and current, the measured frequency and in some cases the rate of change of frequency. The quantities of different measuring point can be communicated and compared using the time stamps, regardless of any time delay associated with the communication system. Finally, the principal output of the PMU is the time-stamped measurement to be transferred over the communication links through suitable modems to a higher level in the measurement system hierarchy. Fig.. Functional Block Diagram of a typical Phasor Measurement Unit 79

Proceedings of National Conference on Signal Processing & Computing (TSPC 5) ISSN NO: 395-0730 9 th -0 th September 05, FET, Rama University, Uttar Pradesh, Kanpur, India III. REALIZATION OF PHASOR MEASUREMENT UNIT IN MATLAB The basic block diagram of phasor measurement unit is already discussed in previous section which becomes the basis of realization of phasor measurement unit in MATLAB. Hence, figure shows the phasor measurement unit block implemented for MATLAB simulation. It is a subsystem consisting of three ports. Each port is connected with each phase in 3-φ system. Conn Conn Fig. 5. Realization of Low Pass Filter in PMU Conn3 Fig.. PMU Block implemented for MATLAB Simulation Figure 3 shows the main components of phasor measurement unit in MATLAB. It consists of potential transformer, low pass filter, analogue to digital converter with discrete Fourier transform & sequence analyzer. Figure 4 & Figure 5 shows the realization of potential transformer part as well as LPF part in MATLAB. Fig. 3. PMU components in MATLAB Fig.6. Analog to Digital Convertor with DFT part of PMU in MATLAB Fig. 4: Potential Transformer part in PMU in MATLAB Figure 6 shows the realization of analog to digital convertor with DFT in MATLAB. Hence, the outputs passes through the Low Pass Filter is used as an input for this part. Obtained complex values of each phase can be realized by putting a scope as shown in figure 6. Then, these complex

Intl J Engg Sci Adv Research 05 Sep;(3):79-83 values are converted into its magnitude & angle part for further processing and the obtained values are kept in corresponding simout / workspace parts. Now, these complex values are used as the inputs for embedded MATLAB function which is actually a sequence analyzer part of phasor measurement unit. From this part, positive sequence voltage is obtained consisting of both magnitude & phase angle by using the equations as given below and it is also shown in figure 7, how positive sequence voltage can be obtained. The negative and zero sequence quantities are not taken into consideration. the proposed system which in turn make easy to predict the possible variation / changes. The obtained results are discussed in next section., fcn, Function, Fig. 7. Sequence Analyzer part of PMU in MATLAB, 3 a b c ; Positive sequence voltage 3 3 3 a b c a b c ; Negative sequence voltage a b c ; Zero sequence voltage Where α = -0.5+j0.866 Generally, positive sequence voltage is the value of voltage in normal condition. In case of any fault or unbalancing, these values will be changed. So, it becomes essential to take care of these values at each moment. In this context, phasor measurement unit does the same where it contains all the required data which changes continuously. Practically phasor measurement unit has a bulk data storage capacity & it checks and compares the changes in data obtained & accordingly makes the precise decision. I. CASE STUDY WITH BUS SYSTEM Hence, bus systems are taken as a simulation model in MATLAB / SIMULINK for study & analysis purpose and realize the phasor measurement unit in the system. In this system there exists a generator with a load connecting with a distributed line. A phasor measurement unit is also connected with the line to keep the data, used in analysis. Hence, with the help of phasor measurement unit, it becomes easy to analyze Fig. 8. Simulink of a Bus system with PMU This system consists of: a. Generator - 0 no. b. 3-φ transformer - 0 no. c. 3-φ series RLC Load - 0 no. d. 3-φ circuit breaker - 0 no. e. Distributed Transmission Line - 0 no. f. Phasor Measurement Unit - 0 no. g. Scope (for measurement) - 04 no. In this system, only positive sequence voltage & its angle are taken into consideration for study & analysis purpose.. DATA USED IN SIMULINK MODEL Data used in the Simulink model in MATLAB as shown in figure 8 are as below. i. Three Phase Source i.e. Generator ii. iii. Base Burden: 00 MA, Base oltage: 3.8k, Phase oltage (in RMS): 3.8k, Nominal Frequency: 50Hz Three Phase Transformer Two Winding, star delta (D), Nominal Power: 60MA, Nominal Frequency: 50Hz, Star Winding Parameters, Phase oltage: 3.8k, Resistance (in pu): 0.00, Inductance (in pu): 0.08, Delta (D) Winding Parameters, Phase oltage: 0k, Resistance (in pu): 0.00, Inductance (in pu): 0.08, Magnetization Resistance (in pu): 500, Magnetization Inductance (in pu): 500. Bus & Bus 8

Proceedings of National Conference on Signal Processing & Computing (TSPC 5) ISSN NO: 395-0730 9 th -0 th September 05, FET, Rama University, Uttar Pradesh, Kanpur, India iv. Phase oltage (in RMS): 0k Three Phase Series RLC Load Phase oltage (in RMS): 0k, Nominal Frequency: 50Hz, Active Power: 000W, Inductive Reactive Power: 00AR, Capacitive Reactive Power: 00AR. v. Distributed Line Parameter vi. Nominal Frequency: 50Hz, R = 0.3864 (ohms/km), R0 = 0.073 (ohms/km), L = 4.64mH (H/km), L0 = 0.9337mH (H/km), C = 7.75 nf (F/km), C0 =.74 nf (F/km), Transmission Line Length: 00 km Circuit Breaker Initial Status: closed, Breaker Resistance: 0.00 ohms, Snubber Resistance: e6 ohms, Snubber Capacitance: infinity (Farad). Figure 9 shows the Simulink model of bus system with intended 3- φ fault. In this system, with the help of 3- φ fault analyzer, the given system is studied and observed for all possible types of faults i.e. for LLLG fault, LLG fault, LG fault, LLL fault & for overloading conditions also. Hence, PMU also observes the system & keep the data of all variation / changes in the parameters, basically positive sequence voltage and current for all these possible fault conditions. Fig. 0. Positive Sequence oltage & Phasor Output in PMU Fig.. Positive Sequence oltage of Bus System observed by PMU Fig.. Negative Sequence oltage of Bus System observed by PMU Fig. 9. Simulink of a Bus system with PMU with intended 3-φ Fault I. RESULT In normal condition i.e. in the system having no intended fault, the positive sequence voltage as observed by phasor measurement unit is.38e+05 & -05.5 as shown in figure 0. Positive, Negative & Zero sequence voltage is also shown in figure, & 3 respectively to see the nature. Fig. 3. Zero Sequence oltage of Bus System observed by PMU

Intl J Engg Sci Adv Research 05 Sep;(3):79-83 In the same way, positive sequence voltage & phasor may also be obtained with different conditions i.e. for LLLG fault, LLG fault, LG fault & LLL fault, etc. For LLLG fault condition, the positive sequence voltage as observed by phasor measurement unit is.34e+05 & -05.6 as shown in figure 4. Positive, Negative & Zero sequence voltage is also shown in figure 5, 6 & 7 respectively to see the nature in faulted condition. Fig.7. Zero Sequence oltage of Bus System observed by PMU for LLLG Fault Similarly, for LLG Fault, LG Fault, LLL Fault & overloading, positive, Negative & Zero sequence voltage and phasor may be obtained by PMU model. Fig. 4. Positive Sequence oltage & Phasor Output in PMU for LLLG Fault Fig. 5: Positive Sequence oltage of Bus System observed by PMU for LLLG Fault Fig. 6. Negative Sequence oltage of Bus System observed by PMU for LLLG Fault II. CONCLUSION The traditional power system monitoring, protection and control measures are based on local measurements. However, it is quite difficult to maintain the stability and security of the system on the whole, if only local measurements are employed in the monitoring, protection and control schemes. One promising way is to provide a system wide protection and control, complementary to the conventional local protection strategy. The main disadvantage of the present conventional method of system monitoring is the inappropriate system dynamic view, or the uncoordinated local actions, like those in decentralized protection devices. Solution to the above can be achieved through dynamic measurement system using synchronized phasor measurement units. This paper enlightens the importance & application of phasor measurement unit in power system. For the study and analysis purpose, phasor measurement unit is realized in MATLAB & it is shown that how phasor measurement unit works to gather the phasor data i.e. voltage, current & phase angle, etc for both faulted condition or for healthy condition. PMU also reflects the status of system for positive, negative & zero sequence condition. Thus, PMU make the complete study & observation of the whole system for each condition at each moment. REFERENCES [] D. R. Gurusinghe, A. D. Rajapakse, and K. Narendra, "Evaluation of steady-state and dynamic performance of a synchronized phasor measurement unit," in Electrical Power and Energy Conference (EPEC), 0 IEEE, 0, pp. 57-6. [] M. Shahraeini and M. H. Javidi, "Wide Area Measurement Systems," Advanced Topics in Measurements, pp. 303-3. [3] F. Ding and C. Booth, "Applications of PMUs in Power Distribution Networks with Distributed Generation," in Universities' Power Engineering Conference (UPEC), Proceedings of 0 46th International, 0, pp. -5. [4] A. G. Phadke and J. S. Thorp, Synchronized phasor measurements and their applications: Springer, 008. [5] A. Phadke, "Computer relaying: its impact on improved control and operation of power systems," Computer Applications in Power, IEEE, vol., pp. 5-0, 988. 83